INTRODUCTION
ThankyouforselectingtheExtechModelGX900TrueRMSMultimeterwith high
measurementaccuracy,quickA/Dconversionrates,andbuiltindataloggingand
trending features. This device is shipped fully tested and calibrated and, with
proper use, will provide years of reliable service. ExtechInstruments is anISO
9001certified
company.
KEYFEATURES
MeasuresAC/DCVoltageandCurrent(includingremoteClampcurrent),
Resistance,Capacitance,Frequency(electricalandelectronic),RPM,Duty
Cycle,dBm/dBV,Diode,Continuity,andTemperature
Builtindataloggerandtrendfeaturesstoremeasurementdatawith
convenientrecallfunctionality
Maximumreading(MAX)andMinimumReading
(MIN)memoryfeatures
ReadingHOLDfeatureforfreezingdisplayedinformation(withAutoHold)
IntuitiveTFTcolorLCDdisplayandconvenientkeypadpushbuttoncontrol
OnscreenHELPutilityforuserhintsandapplicationinformation
QuickA/DconversionsamplerateswithlowpassACfiltering
Internalreal
timecalenda rclockfortimestamping
Industrialstrengthmeterhousing
PleasevisittheExtechInstrumentswebsite(www.extech.com) for
thelatestversionsofManuals,Software,Productupdates,and
othercurrentinformation.
ExtechInstruments
3 GX900-EU-EN V1.6 4/14
TABLEOFCONTENTS
INTRODUCTION.......................................................................................2
KEYFEATURES.........................................................................................2
TABLEOFCONTENTS...............................................................................3
SAFETY....................................................................................................6
INTERNATIONALSAFETYSYMBOLS..........................................................6
IEC1010OVERVOLTAGEINSTALLATIONCATEGORIES...............................6
CAUTIONS...............................................................................................7
SAFETYINSTRUCTIONSINPUTPROTECTIONLIMITS..............................8
FCCCOMPLIANCE....................................................................................9
DESCRIPTIONS.......................................................................................10
METERDESCRIPTION.............................................................................10
INPUTTERMINALDESCRIPTION.............................................................10
KEYPADDESCRIPTION...........................................................................11
LCDDISPLAYDESCRIPTION....................................................................12
QUICKSTARTGUIDE..............................................................................13
MEASUREMENTS...................................................................................14
DCVOLTAGEMEASUREMENTS..............................................................14
ACVOLTAGEMEASUREMENTS..............................................................15
dBm/dBVACMEASUREMENTS..............................................................15
LOWPASSFILTERFORACVMEASUREMENTS........................................16
DC/ACMILLIVOLTMEASUREMENTS......................................................16
ExtechInstruments
4 GX900-EU-EN V1.6 4/14
CURRENTCLAMPMEASUREMENTS.......................................................17
DCCURRENTMEASUREMENTS..............................................................18
ACCURRENTMEASUREMENTS..............................................................19
RESISTANCEMEASUREMENTS...............................................................20
CONTINUITYCHECK...............................................................................21
DIODETEST...........................................................................................21
TEMPERATUREMEASUREMENTS..........................................................22
CAPACITANCEMEASUREMENTS............................................................23
FREQUENCY,DUTYCYCLE,PULSEWIDTH,PERIODMEASUREMENTS....23
RPMMEASUREMENTS...........................................................................24
COUNTERMEASUREMENTS...................................................................24
FUNCTIONSANDFEATURES...................................................................25
FUNCTIONMENUBASICS......................................................................25
THE‘HELP’UTILITY................................................................................25
AUTOMATICANDMANUALRANGING...................................................26
ACANDDCSIGNALS..............................................................................26
MINIMUM(MIN)ANDMAXIMUM(MAX)READINGS............................27
CAPTURINGPEAKVALUES.....................................................................28
RELATIVEMODE....................................................................................28
DATAHOLDANDAUTOHOLDMODE....................................................29
STORINGINDIVIDUALSCREENSHOTS...................................................29
VIEWINGMEMORYDATA......................................................................29
VIEWTRENDDATA................................................................................30
RECORDINGMEASUREMENTS(DATALOGGING)....................................31
ExtechInstruments
5 GX900-EU-EN V1.6 4/14
ZOOMINGONTRENDDATA...................................................................32
METERSETUPOPTIONS.........................................................................32
RESETTHEMETERSETUPOPTIONS........................................................32
METERINFORMATIONSCREEN..............................................................33
SETTINGTHEEVENTTHRESHOLDVALUE...............................................33
CHANGECALIBRATIONPASSWORD.......................................................33
CALIBRATIONACCESS............................................................................34
BLUETOOTH
TM
CAPABILITY....................................................................34
GX900SOFTWARE.................................................................................34
SETTINGTHEDATEANDTIME...............................................................35
AUTOMATICPOWEROFF......................................................................35
TIMEANDDATEFORMATS....................................................................36
NUMERICFORMAT................................................................................36
LANGAUGEFORMAT.............................................................................36
BATTERYANDFUSEREPLACEMENT.......................................................37
BATTERYREPLACEMENT........................................................................37
FUSEREPLACEMENT..............................................................................38
SPECIFICATIONS.....................................................................................39
GENERALSPECIFICATIONS.....................................................................39
ELECTRICALSPECIFICATIONS.................................................................40
ExtechInstruments
6 GX900-EU-EN V1.6 4/14
SAFETY
INTERNATIONALSAFETYSYMBOLS
Thissymbol,adjacenttoanothersymbolorterminal,indicatestheusermust
refertothemanualforfurtherinformation.
This symbol, adjacent to a terminal, indicates that, under normal use,
hazardousvoltagesmaybepresent
Doubleinsulation
This symbol advises the user that the terminals so marked must not
be
connectedtoacircuitpointatwhichthevoltagewithrespecttoearthground
exceeds(forthisspecificinstrument)1000VACorVDC
WARNING This symbol indicates a potentially hazardous situation, which if not
avoided,couldresultindeathorseriousinjury.
CAUTION This symbol indicates a potentially hazardous situation,
which if not
avoided,couldresultindamagetotheinstrument.
IEC1010OVERVOLTAGEINSTALLATIONCATEGORIES
OVERVOLTAGECATEGORYI
Equipment of OVERVOLTAGE CATEGORY I is equipment for connection to circuits in which
measures are taken tolimit the transient overvoltages to an appropriate low level. Examples
includeprotectedelectroniccircuits.
OVERVOLTAGECATEGORYII
EquipmentofOVERVOLTAGECATEGORYIIisenergyconsumingequipmenttobesuppliedfrom
thefixedinstallation.Examplesincludehousehold,office,andlaboratoryappliances.
OVERVOLTAGECATEGORYIII
EquipmentofOVERVOLTAGECATEGORYIIIisequipmentinfixedinstallations.
NoteExamplesincludeswitchesinthefixedinstallationandsomeequipmentforindustrialuse
withpermanentconnectiontothefixedinstallation.
OVERVOLTAGECATEGORYIV
EquipmentofOVERVOLTAGECATEGORYIVis foruse attheoriginoftheinstallation. Examples
includeelectricitymetersandprimaryovercurrentprotectionequipment.
ExtechInstruments
7 GX900-EU-EN V1.6 4/14
CAUTIONS
Improperuseofthismetercancausedamage,shock,injuryordeath.Readand
understandthisusermanualbeforeoperatingthemeter.
Alwaysremovethetestleadsbeforereplacingthebatteryorfuses.
Inspecttheconditionofthetestleadsandthemeteritselfforanydamagebefore
operatingthemeter.
Usegreatcarewhenmakingmeasurementsifthevoltagesaregreaterthan25VAC
rmsor35VDC.Thesevoltagesareconsideredashockhazard.
Warning!ThisisaclassAequipment.Thisequipmentcancauseinterferencein
residentialareas;inthesecasestheoperatormaybe
requiredtotakestepsto
avoidorminimizetheinterference.
Alwaysdischargecapacitorsandremovepowerfromthedeviceundertestbefore
performingDiode,Resistance,orContinuitytests.
Voltagechecksonelectricaloutletscanbedifficultandmisleadingbecauseofthe
uncertaintyofconnectiontotherecessedelectricalcontacts.
Othermeansshould
beusedtoensurethattheterminalsarenot"live".
Iftheequipmentisusedinamannernotspecifiedbythemanufacturer,the
protectionprovidedbytheequipmentmaybeimpaired.
Thisdeviceisnotatoyandmustnotreachchildren’shands.It
containshazardous
objectsaswellassmallpartsthatthechildrencouldswallow.
Donotleavebatteriesandpackingmaterialunattended;theycanbedangerousin
thehandsofchildren.
Intheeventthatthedeviceisgoingtobeunusedforanextendedperiodoftime,
removethe
batteries.
Expiredordamagedbatteriescancausecauterizationoncontactwiththeskin.
Always,therefore,usesuitableglovesinsuchcases.
Ensurethatthebatteriesarenotshortcircuited.Neverincineratebatteries.
ExtechInstruments
8 GX900-EU-EN V1.6 4/14
SAFETYINSTRUCTIONSINPUTPROTECTIONLIMITS
This meter has been designed for safe use, but must be operated with caution. The
ruleslistedinthissafetysectionmustbecarefullyfollowedforsafeoperation.
1. NEVERapplyvoltageorcurrenttothemeterthatexceedsthespecifiedmaximum:
InputProtectionLimits
Function MaximumInput
VDCorVAC 1000VDC/ACrms
mAAC/DC 800mA1000Vfastactingfuse
AAC/DC 10A1000Vfastactingfuse
Frequency,Resistance,
Capacitance,DutyCycle,Diode
Test,Continuity
1000VDC/ACrms
Temperature 1000VDC/ACrms
2. USEEXTREMECAUTIONwhenworkingwithhighvoltages.
3. DONOTmeasurevoltageifthevoltageonthe"COM"inputjackexceeds1000V
aboveearthground.
4. NEVERconnectthemeterleadsacrossavoltagesourcewhilethefunctionswitchis
inthecurrent,resistance,ordiodemode.Doingso
candamagethemeter.
5. ALWAYSdischargefiltercapacitorsinpowersuppliesanddisconnectthepower
whenmakingresistanceordiodetests.
6. ALWAYSturnoffthepoweranddisconnectthetestleadsbeforeopeningthecovers
toreplacethefuseorbatteries.
7. NEVERoperatethemeterunlessthe
backcoverandthebatteryandfusecoversare
inplaceandfastenedsecurely.
8. Iftheequipmentisusedinamannernotspecifiedbythemanufacturer,the
protectionprovidedbytheequipmentmaybeimpaired.
ExtechInstruments
9 GX900-EU-EN V1.6 4/14
FCCCOMPLIANCE
Thisdevicecomplieswithpart15oftheFCCRules.Operationissubjecttothefollowing
twoconditions:
1.Thisdevicemaynotcauseharmfulinterference.
2.Thisdevicemustacceptanyinterferencereceived,includinginterferencethatmay
causeundesiredoperation.
Thisequipmenthasbeentestedandfoundtocomply
withthelimitsforaClassBdigital
device,pursuanttopart15oftheFCCRules.Theselimitsaredesignedtoprovide
reasonableprotectionagainstharmfulinterferenceinaresidentialinstallation.This
equipmentgenerates,uses,andcanradiateradiofrequencyenergyand,ifnotinstalled
andusedinaccordance
withtheinstructions,maycauseharmfulinterferencetoradio
communications.However,thereisnoguaranteethatinterferencewillnotoccurina
particularinstallation.
Ifthisequipmentdoescauseharmfulinterferencetoradioortelevisionreception,which
canbedeterminedbyturningtheequipmentoffandon,theuseris
encouragedtotryto
correcttheinterferencebyoneormoreofthefollowingmeasures:
Reorientorrelocatethereceivingantenna.
Increasetheseparationbetweentheequipmentandreceiver.
Connecttheequipmentintoanoutletonacircuitdifferentfromthattowhichthe
receiverisconnected.
Consultthedealeroranexperiencedradio/TVtechnicianforhelp.
ExtechInstruments
10 GX900-EU-EN V1.6 4/14
DESCRIPTIONS
METERDESCRIPTION
1. LCDdisplay
2. Sub functionkeysF1,F2,F3,andF4
3. DataHOLDbutton
4. MAXMINmemorybutton
5. RotaryPrimaryFunctionSelectSwitch
6. InputjackforAmperes(A)
7. InputjackmA,uA(milli‐&microAmperes)
8. Inputjack(COM)negative
9. Inputjack(positive)
forallfunctions
10. DisplayBacklightcontrol
11. Informationbutton
12. NavigationarrowkeysandOKconfirmationbutton
Note:Batterycompartmentandtiltstandarelocatedontherearoftheinstrument
INPUTTERMINALDESCRIPTION
All functions, excepting current, use the V and COM input terminals. Separate
terminalsareprovidedforcurrentabove500mAandforcurrentbelow500mA.
Input for 0 A to 10.00 A current
Input for 0 A to 500 mA current measurements
Return terminal for all measurements
Input for voltage, continuity, resistance, diode
test, conductance, capacitance
1
2
3
4
11
10
12
9
5
6
78
ExtechInstruments
11 GX900-EU-EN V1.6 4/14
KEYPADDESCRIPTION
Themeter’s12pushbuttonkeypadactivatesfeatures,augmentsfunctionsselectedby
therotaryswitch,andallowsthenavigationofthedisplayedmenustructure
F1F2F3F4keys
Selectssubfunctionsrelatedtothecurrentlyselectedprimary
modesetbytherotaryswitch
Cursorbuttons
Usethecursorbuttonstoselecteditemsinamenutree,adjust
displaycontrast,scrollinformation,andperformdataentry
HOLDbutton
Freezesthedisplayedreadingand,ifdesired,savesthescreenshot.TheHOLDbutton
alsoaccessestheAUTOHOLDfeaturewhichisdetailedinthisInstructionManual
MAX/MINbutton
StartsandstopstheMaximum(MAX)andMinimum(MIN)readingmemory
OKbutton
Confirmsdataentry
RotarySwitch
Selectstheprimarymeasurementfunction;foreach,themeterpresentsastandard
displayforthatfunction(range,measurementunits,andmodifiers).Seetablebelow:
V~ ACvoltagemeasurements
V– DCandAC+DCvoltagemeasurements
mV DC(AC)millivolts,ac+dcmillivolt,Temperature,ClampCurrentmeasu rements
Resistance,Diodetest,capacitance,continuitymeasurements
Hz% Frequencyanddutycyclemeasurements
RPMCounter RPM,Countermeasurements
A AC,dcandac+dcampsmeasurements
mA AC,dcandac+dcmilliampsmeasurements
uA AC,dcandac+dcmicroamperemeasurementsupto5,000μA
INFObutton
Openstheinformationwindow
Backlightbutton
Selectsbacklightintensityfromlowtohigh.Alsousedtoreturnfromanautopower
offcondition
ExtechInstruments
12 GX900-EU-EN V1.6 4/14
LCDDISPLAYDESCRIPTION
1. Softkeylabelsindicatethefunctionofthebuttonjustbelowthedisplayedlabel.
2. BargraphAnalogdisplayfortheinputsignal(Seethe"BarGraph"sectionformore
information).
3. Primarymeasurementdisplayarea*(minussignindicatesanegativereading).
4. Rangeindicatesthemeter’spresentrange
andtherangingmode(autoormanual).
5. Batterylevelindicatesthebatterychargelevel.
6. Timeindicatesthetimesetfortheinternalclock.
7. ModeannunciatorsindicatetheMeter'smode.
8. Minimeasurementdisplayshowstheinputvaluewhentheprimaryandsecondary
displaysarebusywithamenu
screenorpopupmessage.Alsoshowsthelightning
bolticon(whennecessary)inthisarea.
9. Maindisplayprovidesmeasurementinformationregardingtheinputsignal.
10. Dateindicatesthedatesetfortheinternalclock.
11. BeeperindicatestheMeter’saudiblefeedbackisenabled(thisisnotassociatedwith
thecontinuitybeeper).
12. Unitindicatestheunitsofmeasure.AuxiliaryUnitsindicatesmeasurementsthatuse
factorsinsteadofunits(suchasCrestFactor).
13. Bluetoothindicatescommunicationlinkactivity.
14. Relativeindicatesthatthedisplayedvalueisrelativetoastoredreferencevalue.
15. Secondarydisplayshowssecondarymeasurement
informationconcerningtheinput
signal.
*ThePrimarydisplayareaindicatesthemostimportantvalueoftheselectedfunction.
Thesecondarydisplaycontainsthebargraphandothervaluesthatmaybemeasuredin
additiontotheprimaryfunction(forexample,frequencymeasurementsalongwiththe
primaryACvoltagemeasurement).
ExtechInstruments
13 GX900-EU-EN V1.6 4/14
QUICKSTARTGUIDE
StepOne:Ensurethatbatteriesareinstalledandarefresh
StepTwo:CarefullyreadtheSafetysectionofthisInstructionManual
StepThree:ChecktheTableofContentstofindthesectionofthisInstruction
Manualrelatedtothedesiredtest
StepFour:Connectthetestleadstothe
meterandtothedeviceundertestas
describedinthisInstructionManual’ssectionrelatedtothetestinquestion
StepFive:SafelyperformthetestasdescribedinthisInstructionManual
StepSix:ReadthemeasurementvalueontheLCDdisplay
StepSeven:Carefullydisconnectedthemeter’stestleads
fromthecircuitor
deviceundertest
StepEight:ReadthesectionofthisInstructionManualentitledFeaturesand
Functionstolearnmoreaboutthemultitudeofmeterusesandfeatures
StepNine:Disconnectthetestleadsfromthecircuitundertestandfromthe
meterandswitch
OFFthemeterbeforestoring.
ExtechInstruments
14 GX900-EU-EN V1.6 4/14
MEASUREMENTS
WARNING:Riskof electrocution.Highvoltagecircuits,both ACandDC,areverydangerousandshouldbe
measuredwithgreatcare.
1. ALWAYSturnthefunctionswitchtotheOFFpositionwhenthemeterisnotinuse.
2. IfOLappearsinthedisplayduringameasurement,thevalueexceedstheselected
range.ChangetoahigherrangeorusetheAutorangemode.
DCVOLTAGEMEASUREMENTS
CAUTION: Do not measure DC voltages if a motor on the circuit is being switched ON or OFF. Large
voltagesurgesmayoccurthatcandamagethemeter.
1. SetthefunctionswitchtotheV position.
2. Insert the black test lead banana plug into the negative
COM jack. Insert the red test lead banana plug into the
positiveVjack.
3. Touch theblack test probe tip tothe negative side of the
circuit.
4. Touch
the red test probe tip to the positive side of the
circuit.
5. Readthevoltageinthedisplay.
ExtechInstruments
15 GX900-EU-EN V1.6 4/14
ACVOLTAGEMEASUREMENTS
WARNING:RiskofElectrocution.Theprobetips maynotbelongenoughtocontactthelivepartsinside
some240Voutlets forappliances becausethe contactsarerecesseddeepin theoutlets. Asa result,the
readingmayshow0voltswhentheoutletactuallyhasvoltageonit.Makesuretheprobetipsaretouching
themetalcontactsinsidetheoutletbeforeassuming that novoltageispresent.
CAUTION:DonotmeasureACvoltagesifamotoronthecircuitisbeingswitchedONorOFF.Largevoltage
surgesmayoccurthatcandamagethemeter.
1. SetthefunctionswitchtotheV~position.
2. Inserttheblacktestleadbananaplugintothenegative
COMjack.Insertredtestleadbananaplugintothe
positiveVjack.
3. Touchtheblacktestprobetiptotheneutralsideofthe
circuit.Touchtheredtest
probetiptothe“hot”sideof
thecircuit.
4. Readthevoltageinthedisplay.
dBm/dBVACMEASUREMENTS
ThemeteriscapableofdisplayingACvoltageasadBvalue;
relativeto1milliwatt(dBm),relativeto1V(dBV),ortoa
customreferencevalue.
1. SetthefunctionswitchtotheV~position
2. PresstheF1key(MENU)ontheLCDandthen
navigatetothe
dBm/dBVfieldusingthearrowkeys
andthenpressOK.
3. NavigatetothemenuitemlabeleddBmandthen
pressOK.
4. Inserttheblacktestleadbananaplugintothe
negativeCOMjack.InsertredtestleadbananaplugintothepositiveVjack.
5. Touchtheblack
testprobetiptotheneutralsideofthecircuit.Touchtheredtest
probetiptothe“hot”sideofthecircuit.
6. ReadthedBmintheprimarydisplayareaandreadtheVoltageinthesecondary
displayarea.
ExtechInstruments
16 GX900-EU-EN V1.6 4/14
LOWPASSFILTERFORACVMEASUREMENTS
ThemeterisequippedwithaLowPassFilterforAC
measurements.Toactivatethefilterpleasefollowthesteps
below:
1. SettherotaryswitchtotheV~position
2. PresstheF1key(MENU)
3. MovethemenuselectortotheLOWPASSfieldandthen
pressOK
4.
SelectLPF(LowPassFilter)andthenpressOK
5. PresstheF3key(RANGE)andthenpresstheF2key(MANUAL)
6. Movethemenuselectortothe500VfieldandpresstheOKkey
DC/ACMILLIVOLTMEASUREMENTS
CAUTION: Donot measure DC/AC voltagesif amotor onthe circuitis being switched ON orOFF. Large
voltagesurgesmayoccurthatcandamagethemeter.
1. SetthefunctionswitchtothemVposition.
2. PresstheF1key(MENU),movethemenuselectortothemenuitemlabeledmVDC
ormVAC,andthenpresstheOKkey
3. SelectmVDCormVACfromthekeyoptionsandpresstheOKkey.
4. Inserttheblack
testleadbananaplugintothenegativeCOMjack.
5. InserttheredtestleadbananaplugintothepositiveVjack.
6. Touchtheblacktestprobetiptothenegativesideofthecircuit.
7. Touchtheredtestprobetiptothepositivesideofthecircuit.
8. Readthevoltageinthedisplay.
ExtechInstruments
17 GX900-EU-EN V1.6 4/14
CURRENTCLAMPMEASUREMENTS
1. Thismeteroffersremotecurrentclampmeasurementfunctionality.
2. SettherotaryswitchtothemVposition.
3. PresstheF1key(MENU),movethemenu
selectortotheitemlabeledCLAMPDC/AC,
andthenpresstheOKkey.
4. SelecttheitemlabeledRANGE
(0.1~100mV/A)andthenpressthe
OKkey.
5. Connecttheremoteclamptotheinput
terminaljacksensuringproperpolarity.
Inserttheclamp’snegativeleadintothenegativeCOMjackandconnectthe
clamp’spositiveleadintothemeterspositiveVjack.
6. Readthemeasurementinthedisplay.
ExtechInstruments
18 GX900-EU-EN V1.6 4/14
DCCURRENTMEASUREMENTS
CAUTION:Donotmake20Acurrentmeasurementsforlongerthan30seconds.Exceeding30secondsmay
causedamagetothemeterand/orthetestleads.
1. InsertblacktestleadbananaplugintothenegativeCOMjack.
2. Forcurrentmeasurementsupto5000µADC,setthe
functionswitchtotheµApositionandinserttheredtest
leadbananaplugintotheµA/mAjack.PresstheF1key
(MENU)andselectuADC,PresstheOK
key.
3. Forcurrentmeasurementsupto500mADC,setthefunction
switchtothemApositionandinserttheredtestlead
bananaplugintotheµA/mAjack.PresstheF1key(MENU)
andselectmADC,PresstheOKkey.
4. Forcurrentmeasurementsupto10ADC,set
thefunction
switchtothe10Apositionandinserttheredtestlead
bananaplugintothe10Ajack.PresstheF1key(MENU)and
selectADC,PresstheOKkey.
5. Removepowerfromthecircuitundertest,thenopenupthe
circuitatthepointwherecurrentisto
bemeasured.
6. Touchtheblacktestprobetiptothenegativesideofthe
circuit.
7. Touchtheredtestprobetiptothepositivesideofthe
circuit.
8. Applypowertothecircuit.
9. Readthecurrentinthedisplay.
ExtechInstruments
19 GX900-EU-EN V1.6 4/14
ACCURRENTMEASUREMENTS
CAUTION:Donotmake20Acurrentmeasurementsforlongerthan30seconds.Exceeding30secondsmay
causedamagetothemeterand/orthetestleads.
1. Inserttheblacktestleadbananaplugintothenegative
COMjack.
2. Forcurrentmeasurementsupto5000µAAC,setthe
functionswitchtotheµApositionandinserttheredtest
leadbananaplugintotheµA/mAjack.PresstheF1key
(MENU)andselectuAAC,Pressthe
OKkey.
3. Forcurrentmeasurementsupto500mAAC,setthe
functionswitchtothemApositionandinserttheredtest
leadbananaplugintotheµA/mAjack.PresstheF1key
(MENU)andselectmAAC,PresstheOKkey.
4. Forcurrentmeasurementsupto10AAC,
setthefunction
switchtothe10Apositionandinserttheredtestlead
bananaplugintothe10Ajack.PresstheF1key(MENU)
andselectAAC,PresstheOKkey.
5. PressthekeylabeledMENU,movethemenuselectorto
theitemlabeledAC,andthenpressthe
OKkey
6. Removepowerfromthecircuitundertest,thenopenup
thecircuitatthepointwherecurrentistobemeasured.
7. Touchtheblacktestprobetiptotheneutralsideofthecircuit.Touchtheredtest
probetiptothe“hot”sideofthe
circuit.
8. Applypowertothecircuit.
9. Readthecurrentinthedisplay.
ExtechInstruments
20 GX900-EU-EN V1.6 4/14
RESISTANCEMEASUREMENTS
WARNING:To avoid electric shock, disconnect powerto the unit under test and discharge all capacitors
beforetakinganyresistancemeasurements.Removethebatteriesandunplugthelinecords.
1. SetthefunctionswitchtotheΩCAPposition.
2. Inserttheblacktestleadbananaplugintothenegative
COMjack.
3. InserttheredtestleadbananaplugintothepositiveΩjack
4. Touchthetestprobetipsacrossthecircuitorpartunder
test.Itis
besttodisconnectonesideofthepartundertest
sotherestofthecircuitwillnotinterferewiththe
resistancereading.
5. Readtheresistanceinthedisplay.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42

Extech Instruments GX900 User manual

Category
Multimeters
Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI