Amerlux GRUV 1.5” Installation guide

Type
Installation guide
INSTALLATION INSTRUCTIONS
Amerlux
®
LLC
|
178 Bauer Drive, Oakland, NJ 07436
|
p: 973-882-5010 f: 973-882-2605
|
www.amerlux.com
689-0512
pg 1 of 3
GRUV 1.5
LED, Gypsum Board
WARNING:
WARNING: RISK OF FIRE AND ELECTRICAL SHOCK. FIXTURE MUST BE INSTALLED BY A QUALIFIED ELECTRICIAN ONLY.
FIXTURE IS INTENDED FOR INSTALLATION IN ACCORDANCE WITH THE NATIONAL ELECTRICAL CODE, LOCAL AND
FEDERAL SPECIFICATIONS. DISCONNECT POWER AT ELECTRICAL PANEL BEFORE SERVICING.
RETAIN THESE INSTRUCTIONS FOR MAINTENANCE REFERENCE.
RETAIN THESE INSTRUCTIONS FOR MAINTENANCE REFERENCE.
6”
X
X
12”
X
Suspension Points
Example of a Continuous Row
Individual Installation - (Individual fi xture shipped as shown)
1. Hang the Fixture via wire and/or
threaded rods. (Optional)
Blocking as shown by others.
2. Once the fi xture is secure, feed power
source through the knock-out. Splice to
harness according to code.
3. Install ceiling (by others).*
4. Spackle in fi xture.
5. Snap in Lens.
Hanging the fi xture via threaded rods.
Hanging the fi xture via threaded rods.
(Using Yoke)
(Using Yoke)
1. Insert 1/4-20 bolt and secure with nut. (supplied by others)
2. Secure to structure via coupling. (supplied by others)
3. Remove 7/8” KO in access cover at power feed location.
MINIMUM CEILING OPENING MUST BE HELD
MINIMUM CEILING OPENING MUST BE HELD
BY INSTALLER FOR THE FULL LENGTH OF THE RUN
BY INSTALLER FOR THE FULL LENGTH OF THE RUN
DO NOT REMOVE SHIPPING SPACE UNTIL CEILING IS FINISHED.
DO NOT REMOVE SHIPPING SPACE UNTIL CEILING IS FINISHED.
5/8”
2-1/2”
3-1/4”
Snap-in lens
* Fixture MUST be mounted before ceiling is installed.
* Fixture MUST be mounted before ceiling is installed.
3-1/2”
Height @ supspension point
Mounting rods &
hardware by others
Support method
by others
3-1/4”
Fixture height
Ceiling contractor
to spackle, feather
& sand at ceiling
interface.
Blocking
support method
(supplied by others)
6”
6”
6”
Suspension
brackets supplied
by Amerlux
Purple
DIM (+)
Gray
DIM (-)
Green
White
Black
ACCESS PLATE DETAIL
WIRING CONNECTION
0-10V DIM shown. For Non-DIM applications
cap Purple (+) and Gray (-). Wire nuts supplied
by others.
INSTALLATION INSTRUCTIONS
Assembling Continuous Rows
Housing Assembly
Joining the Housings
Joining the Housings
Line up the two housings by using the
alignment splines. Secure them
together by using the Catch and Latch
System on the top of the extrusion.
Catch and
Latch
Alignment Spline
and/or Pins
Refl ector Removal (only required to access driver)
689-0512
pg 2 of 3
GRUV 1.5
LED, Gypsum Board
MAKE SURE TO DISCONNECT ALL ELECTRICAL CONNECTIONS BEFORE ACCESSING LED
MAKE SURE TO DISCONNECT ALL ELECTRICAL CONNECTIONS BEFORE ACCESSING LED
WARNING: Electrostatic and polarity sensitive device. Use caution while handling and wiring.
WARNING: Electrostatic and polarity sensitive device. Use caution while handling and wiring.
1.) LED Fixture:
1.) LED Fixture:
Consult Amerlux for LED maintenance.
2.) LED Replacement:
2.) LED Replacement:
For LED board replacement reference 689-0500 Instruction Sheet.
3.) Driver maintenance:
3.) Driver maintenance:
Drivers are located on tray beneath direct refl ectors, (1) driver per tray, secured by (2)
#8 pal nuts. Remove the refl ector mounting screws to access. For programmable driver
replacement please specify:
Manufacturer, Model No. and Current Setting (_____ mA)
Manufacturer, Model No. and Current Setting (_____ mA). For
drivers with
external
external resistors, keep driver resistor value during driver maintenance or
replacement.
See 710-0134 Wiring Schematic for more details.
Driver tray
#8 pal nut
AMX P/N 625-0059
(2) per driver
Driver
Refl ector
#4-40 self-tap screws
AMX P/N 622-2019
(4) per refl ector
Snap-in lens
Amerlux
®
LLC
|
178 Bauer Drive, Oakland, NJ 07436
|
p: 973-882-5010 f: 973-882-2605
|
www.amerlux.com
INSTALLATION INSTRUCTIONS
689-0512
pg 3 of 3
GRUV 1.5
LED, Gypsum Board
Wall Mounted (Horizontal/Vertical)
WARNING:
WARNING: RISK OF FIRE AND ELECTRICAL SHOCK. FIXTURE MUST BE INSTALLED BY A QUALIFIED ELECTRICIAN ONLY.
FIXTURE IS INTENDED FOR INSTALLATION IN ACCORDANCE WITH THE NATIONAL ELECTRICAL CODE, LOCAL AND
FEDERAL SPECIFICATIONS. DISCONNECT POWER AT ELECTRICAL PANEL BEFORE SERVICING.
RETAIN THESE INSTRUCTIONS FOR MAINTENANCE REFERENCE.
RETAIN THESE INSTRUCTIONS FOR MAINTENANCE REFERENCE.
6”
X
X
12”
X
Suspension Points
Example of a Continuous Row
Individual Installation - (Individual fi xture shipped as shown)
1. Install BLOCKING as shown by others.
Secure housing to blocking using Self-
drilling screws (supplied by others) thru
Fixture Flange.
2. Once the fi xture is secure, feed power
source through the knock-out. Splice to
harness according to code.
3. Install wall (by others).*
4. Spackle in fi xture.
5. Snap in Lens.
MINIMUM CEILING OPENING MUST BE HELD
MINIMUM CEILING OPENING MUST BE HELD
BY INSTALLER FOR THE FULL LENGTH OF THE RUN
BY INSTALLER FOR THE FULL LENGTH OF THE RUN
DO NOT REMOVE SHIPPING SPACE UNTIL CEILING IS FINISHED.
DO NOT REMOVE SHIPPING SPACE UNTIL CEILING IS FINISHED.
5/8”
1-1/2”
3-1/4”
Snap-in lens
* Fixture MUST be mounted before wall is installed.
* Fixture MUST be mounted before wall is installed.
Support method
by others
3-1/4”
Fixture height
Ceiling contractor
to spackle, feather
& sand at ceiling
interface.
Blocking
support method
(supplied by others)
6”
6”
6”
Purple
DIM (+)
Gray
DIM (-)
Green
White
Black
ACCESS PLATE DETAIL
WIRING CONNECTION
0-10V DIM shown. For Non-DIM applications
cap Purple (+) and Gray (-). Wire nuts supplied
by others.
Remove 7/8” KO in access
cover at power feed location.
Blocking required
(by others).
Amerlux
®
LLC
|
178 Bauer Drive, Oakland, NJ 07436
|
p: 973-882-5010 f: 973-882-2605
|
www.amerlux.com
  • Page 1 1
  • Page 2 2
  • Page 3 3

Amerlux GRUV 1.5” Installation guide

Type
Installation guide

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI