Afag RA-40-4F-5E-50-G Operating instructions

Type
Operating instructions

This manual is also suitable for

Rotary axis RA-40
Operating manual
Subject to change. 2 Vers. 1.1 en 01.01.2019
Afag Hardt GmbH Gewerbestraße 11 - 78739 Hardt - Phone:07422/56003-0
Company headquarters: 78739 Hardt, Managing Director: Walter Kunz, HRB 480966 Stuttgart
1 Content
1 Content .................................................................................................................................. 2
2 Preface .................................................................................................................................. 4
3 Safety information ................................................................................................................. 4
General safety information .............................................................................................. 4
Please observe the information in the operating instructions! ......................................... 4
Protection against dangerous movements ...................................................................... 5
Explanation of symbols and signs ................................................................................... 5
3.4.1 Warnings .................................................................................................................. 5
3.4.2 Symbols ................................................................................................................... 5
4 Product description ................................................................................................................ 6
Intended use ................................................................................................................... 6
Warranty and liability ....................................................................................................... 6
5 Rotary axis RA-40 ................................................................................................................. 7
RA-40-2F ........................................................................................................................ 8
RA-40-4F ...................................................................................................................... 10
RA-40-2F-5E ................................................................................................................. 12
RA-40-4F-5E ................................................................................................................. 14
6 Installation ........................................................................................................................... 16
7 Connection .......................................................................................................................... 17
Power supplies ............................................................................................................. 17
Controller C11x0 ........................................................................................................... 18
Controller C12x0 ........................................................................................................... 20
Controller E12x0 ........................................................................................................... 22
Controller E11x0 ........................................................................................................... 24
Controller B1100 ........................................................................................................... 26
Motor connector ............................................................................................................ 28
Plug configuration encoder ........................................................................................... 29
7.8.1 Round connector on the module ............................................................................ 29
7.8.2 Encoder plug configuration on the controller .......................................................... 29
Electrical feed-through / Proximity switch cable-R11 .................................................... 30
Y-distributor plug R12 ................................................................................................... 30
Reference sensor.......................................................................................................... 30
8 6 Commissioning ................................................................................................................. 31
Setting speeds of the electric axes ............................................................................... 31
Overview electrical axes ............................................................................................... 31
Teaching of positions on electric axes .......................................................................... 32
1.1 Switching distance ........................................................................................................ 32
1.1.1 Reference sensor with electric axes ....................................................................... 32
9 Maintenance ........................................................................................................................ 33
10 Repairs ................................................................................................................................ 33
11 Component/replacement part lists ....................................................................................... 34
Overview motor cabel-designation-axes-controller-application ..................................... 34
Subject to change. 3 Vers. 1.1 en 01.01.2019
Afag Hardt GmbH Gewerbestraße 11 - 78739 Hardt - Phone:07422/56003-0
Company headquarters: 78739 Hardt, Managing Director: Walter Kunz, HRB 480966 Stuttgart
Motor cable ................................................................................................................... 35
Encoder ........................................................................................................................ 36
Controller ...................................................................................................................... 36
12 Disposal instructions............................................................................................................ 37
13 Installation manual in accordance with Appendix VI (EC-RL 2006/42/EC) .......................... 38
14 Installation declaration for partly completed machinery (EC-RL 2006/42/EC) ..................... 39
15 Risk assessment (EG-RL 2006/42/EG) ............................................................................... 40
16 Support ................................................................................................................................ 45
17 Notes ................................................................................................................................... 46
Subject to change. 4 Vers. 1.1 en 01.01.2019
Afag Hardt GmbH Gewerbestraße 11 - 78739 Hardt - Phone:07422/56003-0
Company headquarters: 78739 Hardt, Managing Director: Walter Kunz, HRB 480966 Stuttgart
2 Preface
It is our aim to present all essential information contained in these operating instructions as clearly
and concisely as possible. However, please do not hesitate to contact us should you have any queries.
We are always very grateful for your suggestions.
We wish you a successful integration of our devices into your machines or systems.
3 Safety information
General safety information
The pick and place EPS devices are constructed according to the state of the art and the
acknowledged safety-related guidelines; they may only be used
for their intended purpose,
and only when in an operationally safe condition.
Please observe the information in the operating instructions!
The prerequisite for the safe handling and smooth operation of the pick and place EPS devices is
awareness of the fundamental safety standards
Every person tasked with the installation, commissioning, maintenance and operation of the pick and
place EPS devices is required to have thoroughly read and understood the entire user manual,
particularly the "safety notes" chapter.
Furthermore, the rules and regulations on accident prevention applicable at the place of
installation/operation must also be observed. Improper use may result in dangers to the life and limb
of the operator or third parties and in impairments to the machine or other assets.
In the event of faults that could impair safety, the machine must be switched off immediately and
secured to prevent restarting. The fault must then be remedied.
All work on the machines must be carried out with the machines depressurised and disconnected
from the electrical power supply.
For the operation of the machines, the user must provide protective covers, safety doors or other
safety precautions conforming to the normal safety guidelines and safety standards which prevent
people from entering or remaining in the working area of the machines during operation. The
machines may only be put into operation when the guards are securely closed.
Subject to change. 5 Vers. 1.1 en 01.01.2019
Afag Hardt GmbH Gewerbestraße 11 - 78739 Hardt - Phone:07422/56003-0
Company headquarters: 78739 Hardt, Managing Director: Walter Kunz, HRB 480966 Stuttgart
Protection against dangerous movements
Dangerous movements can occur if drives are actuated incorrectly. The drive components are
monitored so that a malfunction can be effectively ruled out. For reasons of personal safety, the risk
of injury and the risk of material damage, however, this must not be relied on exclusively. Faulty drive
movements must be anticipated until installed monitoring devices become go into effect.
Explanation of symbols and signs
The following warnings and symbols help readers understand
this manual quickly and ensure that the EMD modules can be handled
safely.
3.4.1 Warnings
Danger
This symbol draws attention to an imminently hazardous situation that will result in
serious personal injury or even death if the safety regulations are not observed.
Warning
This symbol draws attention to a potentially hazardous situation that will result in
serious personal injury or property damage if the safety
regulations are not
observed.
Caution
This symbol draws attention to a potentially hazardous situation that will result in
property damage if the safety regulations are not observed.
3.4.2 Symbols
Information sign
This symbol indicates information that contributes to better understanding.
!
!
!
INFO
Subject to change. 6 Vers. 1.1 en 01.01.2019
Afag Hardt GmbH Gewerbestraße 11 - 78739 Hardt - Phone:07422/56003-0
Company headquarters: 78739 Hardt, Managing Director: Walter Kunz, HRB 480966 Stuttgart
4 Product description
Intended use
The pick and place EPS devices are used in automation systems and are intended exclusively for
moving workpieces.
The pneumatic modules are intended exclusively for operation with compressed air (4-7 bar). Use for
any other purpose does not constitute an intended use.
The electric axes are intended exclusively for operation with original LinMot components (controllers,
cables...). Use for any other purpose does not constitute an intended use.
The intended use also includes compliance with the prescribed installation and removal instructions,
the service and maintenance conditions and observance of the specifications in the data sheets.
Warranty and liability
The "General Conditions of Sale and Delivery" of Afag GmbH shall apply in all cases.
The term of the warranty on Afag handling components and systems is:
24 months following commissioning, butnot exceeding 27 months following delivery.
Wear parts (e.g. shock absorbers) are excluded from the warranty. *
The guarantee covers the use or repair of defective Afag parts. No further claims will be
accepted.
The warranty will be voided in event of the following:
Use for other than the intended purpose
Failure to observe the information on installation, commissioning, operation and
maintenance in the operating manual
Improper installation, commissioning, operation and maintenance
Independent repairs and constructional changes without prior instruction by Afag
Automation AG/Afag Hardt GmbH
Removal of the serial number on the product
Using the module without shock absorbers, or with defective shock absorbers
Inadequate monitoring of wear parts
Failure to observe the EC Machinery Directive, accident prevention regulations, VDE
guidelines as well as the safety/installation instructions
Emergencies caused by external influence or force majeure.
*A customer has the right to a defect-free product. This is also applicable for accessories and
wear parts, if they are defective.
Subject to change. 7 Vers. 1.1 en 01.01.2019
Afag Hardt GmbH Gewerbestraße 11 - 78739 Hardt - Phone:07422/56003-0
Company headquarters: 78739 Hardt, Managing Director: Walter Kunz, HRB 480966 Stuttgart
5 Rotary axis RA-40
Allgemein
Operating temperature: 0 - 50 °C
Bearing temperature: 0 - 50 °C
Humidity: < 90 %
Module stresses
Max. torque Mr: 10Nm
Max. press-in force Fe: 800N
Max. radial force: ±700N
Max. pulling force Fz: 350N
Subject to change. 8 Vers. 1.1 en 01.01.2019
Afag Hardt GmbH Gewerbestraße 11 - 78739 Hardt - Phone:07422/56003-0
Company headquarters: 78739 Hardt, Managing Director: Walter Kunz, HRB 480966 Stuttgart
RA-40-2F
Type RA-40-2F-30-G RA-40-2F-30-W RA-40-2F-30-G-ZE RA-40-2F-30-W-ZE
Order number 50473180 50473182 50473183 50473184
Net weight 0.69 kg 0.69 kg 0.74 kg 0.74 kg
Angle of rotation
Max. rotational speed
280 rpm
280 rpm
Fluid passages
2
2
Continuous torque
1.2 Nm
1.2 Nm
Max. output torque 2.4 Nm 2.4 Nm 2.4 Nm 2.4 Nm
Ratio 30:1 30:1 30:1 30:1
Repeat accuracy +/- 0.0017 ° +/- 0.0017 ° +/- 0.0017 ° +/- 0.0017 °
Encoder
SV-TLL ABZ,
SV-TLL ABZ,
61440 Inc/U
Mounting position
Type RA-40-2F-50-G RA-40-2F-50-W RA-40-2F-50-G-ZE RA-40-2F-50-W-ZE
Order number 50473185 50473186 50473187 50473188
Net weight 0.69 kg 0.69 kg 0.74 kg 0.74 kg
Angle of rotation
Max. rotational speed
140 rpm
140 rpm
Fluid passages
2
2
Continuous torque 2 Nm 2 Nm 2 Nm 2 Nm
Max. output torque 4 Nm 4 Nm 4 Nm 4 Nm
Ratio 50:1 50:1 50:1 50:1
Repeat accuracy +/- 0.0017 ° +/- 0.0017 ° +/- 0.0017 ° +/- 0.0017 °
Encoder
SV-TLL ABZ,
SV-TLL ABZ,
102400 Inc/U
Mounting position
The technical data pertains to Afag standard test conditions. Air purity class 5 (ISO 14644-1)
Cleanroom class: 10 000 (Federal Standard 209E)
In the article description of a rotary axis the “F” stands for fluid passages and the “E” for electrical feed-through. There are two
version of motor plugs. A „G“ in the article description of the rotary axis stand for a straight and the „W“ for an angular plug. Also
see order key for RA-40.
Subject to change. 9 Vers. 1.1 en 01.01.2019
Afag Hardt GmbH Gewerbestraße 11 - 78739 Hardt - Phone:07422/56003-0
Company headquarters: 78739 Hardt, Managing Director: Walter Kunz, HRB 480966 Stuttgart
Type RA-40-2F RA-40-2F (ZE)
A
141 mm
159 mm
Subject to change. 10 Vers. 1.1 en 01.01.2019
Afag Hardt GmbH Gewerbestraße 11 - 78739 Hardt - Phone:07422/56003-0
Company headquarters: 78739 Hardt, Managing Director: Walter Kunz, HRB 480966 Stuttgart
RA-40-4F
Type RA-40-4F-30-G RA-40-4F-30-W RA-40-4F-30-G-ZE RA-40-4F-30-W-ZE
Order number 50473189 50473190 50473191 50473192
Net weight 0.74 kg 0.74 kg 0.79 kg 0.79 kg
Angle of rotation
Max. rotational speed
280 rpm
280 rpm
Fluid passages
2
2
Continuous torque
1.2 Nm
1.2 Nm
Max. output torque 2.4 Nm 2.4 Nm 2.4 Nm 2.4 Nm
Ratio 30:1 30:1 30:1 30:1
Repeat accuracy +/- 0.0017 ° +/- 0.0017 ° +/- 0.0017 ° +/- 0.0017 °
Encoder
SV-TLL ABZ,
SV-TLL ABZ,
61440 Inc/U
Mounting position
Type RA-40-4F-50-G RA-40-4F-50-W RA-40-4F-50-G-ZE RA-40-4F-50-W-ZE
Order number 50473193 50473194 50473195 50473196
Net weight 0.74 kg 0.74 kg 0.79 kg 0.79 kg
Angle of rotation
Max. rotational speed
140 rpm
140 rpm
Fluid passages
2
2
Continuous torque 2 Nm 2 Nm 2 Nm 2 Nm
Max. output torque 4 Nm 4 Nm 4 Nm 4 Nm
Ratio 50:1 50:1 50:1 50:1
Repeat accuracy +/- 0.0017 ° +/- 0.0017 ° +/- 0.0017 ° +/- 0.0017 °
Encoder
SV-TLL ABZ,
SV-TLL ABZ,
102400 Inc/U
Mounting position
The technical data pertains to Afag standard test conditions. Air purity class 5 (ISO 14644-1)
Cleanroom class: 10 000 (Federal Standard 209E)
In the article description of a rotary axis the “F” stands for fluid passages and the “E” for electrical feed-through. There are two
version of motor plugs. A „G“ in the article description of the rotary axis stand for a straight and the „W“ for an angular plug. Also
see order key for RA-40.
Subject to change. 11 Vers. 1.1 en 01.01.2019
Afag Hardt GmbH Gewerbestraße 11 - 78739 Hardt - Phone:07422/56003-0
Company headquarters: 78739 Hardt, Managing Director: Walter Kunz, HRB 480966 Stuttgart
Type RA-40-4F RA-40-4F (ZE)
A
151 mm
169 mm
Subject to change. 12 Vers. 1.1 en 01.01.2019
Afag Hardt GmbH Gewerbestraße 11 - 78739 Hardt - Phone:07422/56003-0
Company headquarters: 78739 Hardt, Managing Director: Walter Kunz, HRB 480966 Stuttgart
RA-40-2F-5E
Type RA-40-2F-5E-30-G RA-40-2F-5E-30-W RA-40-2F-5E-
RA-40-2F-5E-
30-W-ZE
Order number 50473197 50473198 50473200 50473201
Net weight
0.84 kg
0.89 kg
Angle of rotation
Max. rotational speed
280 rpm
280 rpm
Elektrische Durchführungen
5 x 2 A
5 x 2 A
Fluid passages 2 2 2 2
Continuous torque 1.2 Nm 1.2 Nm 1.2 Nm 1.2 Nm
Max. output torque 2.4 Nm 2.4 Nm 2.4 Nm 2.4 Nm
Ratio 30:1 30:1 30:1 30:1
Repeat accuracy
+/- 0.0017 °
+/- 0.0017 °
Encoder
SV-TLL ABZ,
SV-TLL ABZ,
61440 Inc/U
Mounting position
Type RA-40-2F-5E-50-G RA-40-2F-5E-50-W RA-40-2F-5E-
RA-40-2F-5E-
50-W-ZE
Order number 50473202 50473203 50473204 50473205
Net weight
0.84 kg
0.89 kg
Angle of rotation
Max. rotational speed 140 rpm 140 rpm 140 rpm 140 rpm
Elektrische Durchführungen 5 x 2 A 5 x 2 A 5 x 2 A 5 x 2 A
Fluid passages 2 2 2 2
Continuous torque
2 Nm
2 Nm
Max. output torque
4 Nm
4 Nm
Ratio
50:1
50:1
Repeat accuracy +/- 0.0017 ° +/- 0.0017 ° +/- 0.0017 ° +/- 0.0017 °
Encoder
SV-TLL ABZ,
SV-TLL ABZ,
102400 Inc/U
Mounting position
The technical data pertains to Afag standard test conditions. Air purity class 5 (ISO 14644-1)
Cleanroom class: 10 000 (Federal Standard 209E)
In the article description of a rotary axis the “F” stands for fluid passages and the “E” for electrical feed-through. There are two
version of motor plugs. A „G“ in the article description of the rotary axis stand for a straight and the „W for an angular plug. Also
see order key for RA-40.
Subject to change. 13 Vers. 1.1 en 01.01.2019
Afag Hardt GmbH Gewerbestraße 11 - 78739 Hardt - Phone:07422/56003-0
Company headquarters: 78739 Hardt, Managing Director: Walter Kunz, HRB 480966 Stuttgart
Type RA-40-2F-5E RA-40-2F-5E (ZE)
A
155 mm
173 mm
Subject to change. 14 Vers. 1.1 en 01.01.2019
Afag Hardt GmbH Gewerbestraße 11 - 78739 Hardt - Phone:07422/56003-0
Company headquarters: 78739 Hardt, Managing Director: Walter Kunz, HRB 480966 Stuttgart
RA-40-4F-5E
Type RA-40-4F-5E-30-G RA-40-4F-5E-30-W RA-40-4F-5E-
RA-40-4F-5E-
30-W-ZE
Order number 50473206 50473207 50473208 50473209
Net weight
0.84 kg
0.89 kg
Angle of rotation
Max. rotational speed
280 rpm
280 rpm
Elektrische Durchführungen
5 x 2 A
5 x 2 A
Fluid passages 4 4 4 4
Continuous torque 1.2 Nm 1.2 Nm 1.2 Nm 1.2 Nm
Max. output torque 2.4 Nm 2.4 Nm 2.4 Nm 2.4 Nm
Ratio 30:1 30:1 30:1 30:1
Repeat accuracy
+/- 0.0017 °
+/- 0.0017 °
Encoder
SV-TLL ABZ,
SV-TLL ABZ,
61440 Inc/U
Mounting position
Type RA-40-4F-5E-50-G RA-40-4F-5E-50-W RA-40-4F-5E-
RA-40-4F-5E-
50-W-ZE
Order number 50473210 50473211 50473212 50473213
Net weight
0.84 kg
0.89 kg
Angle of rotation
Max. rotational speed 140 rpm 140 rpm 140 rpm 140 rpm
Elektrische Durchführungen 5 x 2 A 5 x 2 A 5 x 2 A 5 x 2 A
Fluid passages 4 4 4 4
Continuous torque
2 Nm
2 Nm
Max. output torque
4 Nm
4 Nm
Ratio
50:1
50:1
Repeat accuracy +/- 0.0017 ° +/- 0.0017 ° +/- 0.0017 ° +/- 0.0017 °
Encoder
SV-TLL ABZ,
SV-TLL ABZ,
102400 Inc/U
Mounting position
The technical data pertains to Afag standard test conditions. Air purity class 5 (ISO 14644-1)
Cleanroom class: 10 000 (Federal Standard 209E)
In the article description of a rotary axis the “F” stands for fluid passages and the “E” for electrical feed-through. There are two
version of motor plugs. A „G“ in the article description of the rotary axis stand for a straight and the „W for an angular plug. Also
see order key for RA-40.
Subject to change. 15 Vers. 1.1 en 01.01.2019
Afag Hardt GmbH Gewerbestraße 11 - 78739 Hardt - Phone:07422/56003-0
Company headquarters: 78739 Hardt, Managing Director: Walter Kunz, HRB 480966 Stuttgart
Type RA-40-4F-5E RA-40-4F-5E (ZE)
A
165 mm
183 mm
Subject to change. 16 Vers. 1.1 en 01.01.2019
Afag Hardt GmbH Gewerbestraße 11 - 78739 Hardt - Phone:07422/56003-0
Company headquarters: 78739 Hardt, Managing Director: Walter Kunz, HRB 480966 Stuttgart
6 Installation
Caution
The pick and place EPS device is a precision-mechanical unit. Therefore, you must
ensure the necessary care and cleanliness during transportation, installation and
adjustment.
Caution
Only original LinMot cables may be used for the operation of the electric axes.
Otherwise, damage or faults may occur.
The installation material is dependent on the module utilised as well as the adaptors and weights.
Type
Recommended installation material
RA-40
2/4x O-ring 2.5x0.62 NBR70
2x centering bushings Ø7x3
2x centering bushings Ø5x2.5
!
!
Subject to change. 17 Vers. 1.1 en 01.01.2019
Afag Hardt GmbH Gewerbestraße 11 - 78739 Hardt - Phone:07422/56003-0
Company headquarters: 78739 Hardt, Managing Director: Walter Kunz, HRB 480966 Stuttgart
7 Connection
Power supplies
Brief overview of the technical data of the power supplies. More detailed information can be found in
the operating manual of the power supply.
Technical data
SPH500-7207
SPH1013-7214
NT01-72/1500Multi
Type
Primary switched-mode power supply
Primary voltage
90-132 VAC, 50/60 Hz oder
180-264 VAC, 50/60 Hz
(automatic switching)
3x340 550 VAC, 50/60 Hz
3x230/400/480 VAC, 50/60 Hz
Secondary voltage
54-80 VDC variable
54-80 VDC variable
72 VDC
Output power
480 W
960 W
1500 W
Power consumtion
600 W
1100 W
1500 W
Power loss max.
54 W
91 W
110 W
Peak output current (>0.5 s)
10 A
27 A
50 A
Nominal current
240 VAC = 4.5 A,
120 VAC = 9 A
380 VAC = 3.1 A
3x230 VAC = 3.5 A, 400 VAC = 2 A,
480 VAC = 1.7 A
Efficiency
88%
91,5%
85% (at rated power)
Protection type
IP 20
IP 20
IP 20
Operating temperature
-25…70 °C
-25…70 °C
0…40 °C
Mass
1 kg
2 kg
17 kg
Dimension (HxWxD)
125x62x121 mm
230x66x177 mm
275x280x165 mm
External fuse
6 A (C,D,K Type)
16 - 32 A (C,D,K Type)
8 A (C,D,K Type)
Subject to change. 18 Vers. 1.1 en 01.01.2019
Afag Hardt GmbH Gewerbestraße 11 - 78739 Hardt - Phone:07422/56003-0
Company headquarters: 78739 Hardt, Managing Director: Walter Kunz, HRB 480966 Stuttgart
Controller C11x0
Brief overview of the interfaces of the controller C11x0. More detailed information can be found in the
operating instructions of the controller.
The controllers are preconfigured so that software modifications are generally not necessary. If a
modification is necessary, the LinMot-Talk 1100 software can be downloaded free of charge from
the website www.linmot.com.
Technical data
C1150-EC-XC
C1150-PN-XC
C1150-GP-XC
Logic power supply
24 VDC
24 VDC
24 VDC
Motor voltage supply
24 - 72 VDC
24 - 72 VDC
24 - 72 VDC
Max. output current motor (at 72 V)
25 A
25 A
25 A
Bus system interfaces
EtherCat
CANopen
DeviceNet
RS485/232
Digitale I/Os
Profinet
CANopen
DeviceNet
RS485/232
Digitale I/Os
CANopen
DeviceNet
RS485/232
Digitale I/Os
Max. power consumption
30 W
30 W
30 W
Protection type
IP 20
IP 20
IP 20
Operating temperature
0 - 40 °C
0 - 40 °C
0 - 40 °C
Mass
1.5 kg
1.5 kg
1.5 kg
Distance between controllers
20 mm left/right
50 mm below/above
20 mm left/right
50 mm below/above
20 mm left/right
50 mm below/above
Fuse 72 V supply
16 AT
16 AT
16 AT
Fuse 24 V supply
3 AT
3 AT
3 AT
Subject to change. 19 Vers. 1.1 en 01.01.2019
Afag Hardt GmbH Gewerbestraße 11 - 78739 Hardt - Phone:07422/56003-0
Company headquarters: 78739 Hardt, Managing Director: Walter Kunz, HRB 480966 Stuttgart
Connection
Description
X1 PWR+
Motor voltage supply +72 VDC
X1 PGND
Motor voltage supply GND
X2
Motorphasen
X3
Motor signals
X33
Safety relay (optional on -S1 version)
X4.8
/Quickstop
X4.7
Reference sensor (optional)
X4.2
Logic power supply +24 VDC
X4.1
Logic power supply GND
Danger when the safety door is open
The "safety relay" input (X33) on the controller C11xx must be deactivated or the power
pack (72 V) must be reliably disconnected from the power supply on the primary side.
!
2x RT Ethernet
safety relays
/Quickstop
mains
GND
+24VD
RS232
mains
PWR+
PGND
motor cable
external position
measuring system
(optional)
72 VDC
mains
24 VDC
mains
Subject to change. 20 Vers. 1.1 en 01.01.2019
Afag Hardt GmbH Gewerbestraße 11 - 78739 Hardt - Phone:07422/56003-0
Company headquarters: 78739 Hardt, Managing Director: Walter Kunz, HRB 480966 Stuttgart
Controller C12x0
Brief overview of the interfaces of the controller C12x0. More detailed information can be found in the
operating manual of the controller.
The controllers are preconfigured so that software modifications are generally not necessary. If a
modification is necessary, the LinMot-Talk 1100 software can be downloaded free of charge from
the website www.linmot.com.
Technical data
C1250-EC-XC
C1250-IP-XC
C1250-PL-XC
C1250-PN-XC
Logic power supply
24 VDC
24 VDC
24 VDC
24 VDC
Motor voltage supply
24 - 72 VDC
24 - 72 VDC
24 - 72 VDC
24 - 72 VDC
Max. output current motor
(at 72 V)
25 A
25 A
25 A
25 A
Bus system interfaces
EtherCat
CANopen
DeviceNet
RS485/232
Digitale I/Os
Master Encoder
Ethernet IP
CANopen
DeviceNet
RS485/232
Digitale I/Os
Master Encoder
PowerLink
CANopen
DeviceNet
RS485/232
Digitale I/Os
Master Encoder
Profinet
CANopen
DeviceNet
RS485/232
Digitale I/Os
Master Encoder
Max. power consumption
30 W
30 W
30 W
30 W
Protection type
IP 20
IP 20
IP 20
IP 20
Operating temperature
0 - 40 °C
0 - 40 °C
0 - 40 °C
0 - 40 °C
Mass
0.7 kg
0.7 kg
0.7 kg
0.7 kg
Distance between
controllers
20 mm left/right
50 mm below/above
20 mm left/right
50 mm below/above
20 mm left/right
50 mm below/above
20 mm left/right
50 mm below/above
Fuse 72 V supply
16 AT
16 AT
16 AT
16 AT
Fuse 24 V supply
3 AT
3 AT
3 AT
3 AT
Technical data
C1250-SC-XC
C1250-SE-XC
Logic power supply
24 VDC
24 VDC
Motor voltage supply
24 - 72 VDC
24 - 72 VDC
Max. output current motor
(at 72 V)
25 A
25 A
Bus system interfaces
Sercos III
CANopen
DeviceNet
RS485/232
Digitale I/Os
Master Encoder
Sercos over EtherCAT
CANopen
DeviceNet
RS485/232
Digitale I/Os
Master Encoder
Max.
30 W
30 W
Protection type
IP 20
IP 20
Operating temperature
0 - 40 °C
0 - 40 °C
Mass
0.7 kg
0.7 kg
Distance between
controllers
20 mm left/right
50 mm below/above
20 mm left/right
50 mm below/above
Fuse 72 V supply
16 AT
16 AT
Fuse 24 V supply
3 AT
3 AT
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47

Afag RA-40-4F-5E-50-G Operating instructions

Type
Operating instructions
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI