FEATURES
•Automatically comesonwhen motion isde-
tected.
•Automaticallyturnslighto.
•Photocell keeps the light o during daylight
hours.
UNPACKING
Besuretoremoveallcontentsfrompackaging
andverifyallitemsarepresentbeforeassembling
thislightxture.ispackageincludesthefol-
lowingitems:
•CoachLight
•MountingBracket(MountingBracketScrews
AreNotIncluded-Use4mmdia.(8G)x30mm
Screws)
•OwnersManual
•Some models will include an additional tail
assembly
REQUIREMENTS
•elightcontrolrequires230voltsAC.
•IfyouwanttouseManualMode,thecontrol
mustbewiredthroughaswitch.
•It is illegal for persons other than a licensed
electrician or person authorized by legislation
to work on xed wiring or other electrical
installations.
Before installation, record the model num-
ber listed inside the xture. Attach receipt
in case of possible warranty issues.
Model Number:
© 2011 The Chamberlain Group, Inc 201101-01A
Motion Sensing
Coach Light
Coach Light*
*Note:Illustrationsareforreferenceonlyandmay
bedierentfromactualproduct
Installation and Operating Instructions
Models: SH-9132AU, SH-9133AU,
SH-9138AU, SH-9144AU, and
SH-9150AU
®
TM
2201101-01
IMPORTANT SAFETY AND INSTALLATION INFORMATION
Beforeinstallingcoachlight,readallinstructionscarefullyandkeepowner’smanualforfuturerefer-
ence.
•
WARNING:Topreventelectricshock,pleaseensurethatpowerisdisconnectedbeforeinstallation.
•isxturemustbeconnectedtoa230V-240V~50Hzpowersource.
•exturemustbeproperlygrounded.
•isxtureisdesignedforoutdoorinstallationandshouldbemountedtoawall.
•Toachievebestresults,thisxtureshouldbemounted1.8meters(6feet)abovetheground.
•Donotusedimmerswitchesortimerswiththisxture.
esensoronthislightxturedetectsmotionbythemovementofheatacrossthecoveragearea.
However,followingareexamplesofobjectsthatalsoproduceheatandcancausethesensortotrigger:
•PoolsofWater •AirConditioners
•DryerVents •Animals
•HeatingVents •AutomobileTrac
Ifyoususpectthataheatsourceofthistypeistriggeringthesensor,reducethesensitivity.
esensoronthisxtureismoresensitivetothemovementofheatmovingacrossthecoveragearea
andlesssensitivetothemovementofheatdirectlytowardsit.
Least Sensitive Most Sensitive
Sensor
Motion Motion
3
201101-01
INSTALLATION
This light xture must be installed by a
licensed electrician or other person autho-
rized by legislation to work on xed wiring
or other electrical installations.
IMPORTANT: Do NOT use with dimmers or
timers.
Forbest performance, mountthextureabout
1.8meters(6feet)abovetheground.isxture
comeswithamountingbracket.Itispre-assembled
onthextureforshipping.
1. Removetwodecorativenuts.
2. Removemountingbracket.
3. Tightenxturemountingscrewsngertight
ontomountingbracket.
4. Positionmountingbracketagainstthewalland
markthepositionsforthemountingscrews
andtheearthscrew.
Note:Makesurexture
mountingscrewsareparalleltothegroundbefore
tighteningbrackettowall(seeFigure2).
5. Useapowerdrilltodrillintothewalltoprovide
asuitablemountingforthescrews.
Note:Also
drilla6mmdeeppilotholefortheearthscrew.
•Bracketmountingscrewsarenotincluded.
Use4mmdia.(8G)x30mmscrews.
•Careshouldbetakentoavoiddrillingor
screwingintoconcealedelectricalwiring.
•Forsolidbrickwalls,screwsandmasonry
plugsshouldbeused.
6.
Attachmountingbrackettowallwithaminimum
oftwoscrews.Useanyslotsthatworkbestfor
thetypeofinstallation.Note:Makesurexture
mountingscrewsareparalleltothegroundbefore
tighteningbrackettowall(seeFigure2).
WARNING: Turn power o at circuit
breaker or fuse. Place tape over circuit
breaker switch and verify power is o at
the xture.
Note:Werecommendhavinganassistanthelphold
thelanternassemblyduringthewiringprocess.
Mounting
Bracket
Decorative Nut
Fixture
Mounting Screw
Bracket
Mounting
Screws (Not
Included)
Fixture
Mounting
Screws Earth Screw
Mounting
Bracket
Figure 1
Figure 2
4201101-01
WallMounting Bracket
FINAL ASSEMBLY
1. Doublecheckallwiringconnections.
2.
Slidethextureassemblyontothemounting
screwsasshownonoutercartonpackaging.Make
surewiresdonotobstructmountingscrews
(see
Figure4)
.
3. Tightendecorativenutsremovedinstep1ofIn-
stallation sectionsecurelyagainstxturebase.
4. Caulkaroundxturebasewithsiliconeweather
sealant.IMPORTANT:Ensurethatthedrainhole
atthebottomoftheunitisnotblocked.
5. Installbulb.Do not exceed wattage rating on
xture label.
6. If applicable, install xture top using two
decorativescrews(seeFigure5).
7. If applicable, remove nut below sensor and
installxturetailassembly(seeFigure6).Use
thenutremovedtosecurethetailassembly.
Mounting Screw
Terminal Block Insulator
Decorative Nut
Terminal Block
From Fixture From AC Source
WIRING
Connectthexturewirestotheterminalblock
accordingtodiagram.Makesureallscrewson
terminalblockaretightenedsecurelyandterminal
blockinsulatorisfoldedoverterminalblock.
WARNING: Turn power o at circuit
breaker or fuse. Place tape over circuit
breaker switch and verify power is o at
the xture.
WARNING: Risk of electric shock.
Terminal block insulator must cover
terminal block after wiring is complete.
Green/YellowGreen/Yellow
Blue Blue or Black
Brow
nR
ed or Brown
Figure 3
Figure 4
IMPORTANT: Mounting bracket must be
earthed. Attach earth wire to bracket at the
earth screw. Tighten earth screw securely
against earth wire.
5
201101-01
Decorative ScrewFixture Top TESTING AND ADJUSTMENTS
1. Turn on the circuit breaker and light
switch.
Note:Sensorhasa11/2minutewarmupperiod
beforeitwilldetectmotion.Whenrstturned
onwait11/2minutes.
2. Set:
•ON-TIMEswitchtoTEST
•SENSITIVITYtoMid(M)position
3.
Walkthroughthecoverageareanotingwhere
youarewhenthelightsturnon.InTESTmode,
lightwillstayonfor5secondsaftermotionhas
stoppedandthenturno.
4. Ifthextureisequippedwitharotatablesensor
(seeFigure7),
movethesensorheadleftor
righttochangethecoveragearea(seeFigure
8).Note:Graspthesensoronlyasshownand
turn the entire sensor.Any other method
may damage the sensor. Do not force it
past the stops.
Figure 5
Figure 6
Figure 7
TEST 1 5 10 MIN
ON-TIME
LO - M - HI
SENSITIVITY
6201101-01
Note:Whenrstturnedonwaitabout11/2minutes
forthecircuitrytocalibrate.
*resetstoAutoModeatdawn.
OPERATION
MANUAL MODE
Mode: On-Time Works: Day Night
Test 5Seconds x x
Auto 1,5,or10
Minutes x
Manual ToDawn* x
... back on.
1 Second
OFF then...
Manual mode only works at
night because daylight returns
thesensortoAUTO.
Flipthelightswitchoforone
second then back on to toggle
betweenAUTOandMANUAL
MODE.
Manualmodeworksonlywith
theON-TIMEswitchinthe1,
5,or10position.
5.
Increaseordecreasethesensitivityasneeded.
Toomuchsensitivitymaycausefalsetriggering
duetoheatsourcesinthecoveragearea(see
Troubleshootingsection).
6. SettheamountofON-TIMEyouwantthe
lighttostayonaftermotionisdetected(1,5,
or10minutes).etimerwillresetaslong
asthereismotionpresent.Oncemotionhas
stopped, the timer will time-out after the
selectedamountoftime.
9.1 m
(30 ft.)
1.8 m
(6 ft.)
Maximum
Maximum Range Coverage Angle*
(Side View) (Top View)
MANUAL MODE
AUTO
TEST
ON-TIME Switch at 1, 5,
or 10 minutes
MODE SWITCHING SUMMARY
Flip light switch
o for one second
then back on*
*Ifyougetconfusedwhileswitchingmodes,turn
thepoweroforoneminute,thenbackon.After
thecalibrationtimethecontrolwillbeintheAUTO
mode.
150°
Rotating Sensor Head to Change Coverage Area
1
5
0
°
1
5
0
°
Figure 8
7
201101-01
SPECIFICATIONS
Range.................................................Upto9.1m(30ft.)[varieswithsurroundingtemperature]
SensingAngle.....................................Upto150°
SensorAimingAdjustmentAngle.....90°
ElectricalLoad...................................Seelabelonxtureformaximumwattagerating
BulbType...........................................E27ScrewBase,Type“A
PowerRequirements...........................230VAC,50Hz
OperatingModes...............................TEST,AUTO,andMANUALMODE
ON-Timer..........................................1,5,10minutes
TestTimer..........................................5Seconds
ManualModeTimer..........................Dusk-to-Dawn
IngressProtection...............................IP23
eChamberlainGroupreservestherighttodiscontinueproductsandtochangespecicationsat
anytimewithoutincurringanyobligationtoincorporatenewfeaturesinproductspreviouslysold.
SYMPTOM POSSIBLE CAUSE SOLUTION
Lightwillnotcome
on.
1. Lightswitchisturnedo.
2. Bulbislooseorburnedout.
3. Fuseisblownorcircuitbreakeristurnedo.
4. Daylightturn-oisineect.
5. Incorrectcircuitwiring,ifthisisanewinstallation.
1. Turnlightswitchon.
2. Checkbulbandreplaceifnecessary.
3. Replacefuseorturncircuitbreakeron.
4. Recheckafterdark.
5. Verifywiringiscorrect.
Lightcomesonin
daylight.
1. Light control may be installed in a relatively dark
location.
2. LightcontrolisinTEST.
1. e xture is operating normally under these
conditions.
2. SetON-TIMEswitchto1,5,or10minutes.
Lightcomesonfor
noapparentreason.
1. Lightcontrolmaybesensingsmallanimalsorautomobile
trac.
2. Sensitivityissettoohigh.
1. Re-aimsensor.Reducesensitivity.
2. Reducesensitivity.
Lightstayson
continuously.
1. esensormaybepickingupaheatsourcelikeanair
vent, dryer vent, or brightly painted, heat-reective
surface.
2. LightcontrolisinManualmode.
3. Sensitivityissettoohigh.
1. Re-aimsensor.Reducesensitivity.
2. SwitchtoAuto.
3. Reducesensitivity.
Lightasheson
ando.
1. LightcontrolisintheTESTmodeandwarmingup.
2. Heatbeingreectedfromotherobjectsmaybeaecting
thesensor.
1. Flashingisnormalundertheseconditions.
2. Re-aimsensor.Reducesensitivity.
TROUBLESHOOTING GUIDE
8201101-01
CHAMBERLAIN LIMITED WARRANTY
Lighting and Chime Products
ChamberlainAustralia PtyLimited /Chamberlain NewZealand Limited(Chamberlain)is committedtomanufacturing andsupplyinghighqualitygoods.As
partofthiscommitment,weseektoprovidereliableserviceandsupportforourgoodsandarepleasedtoprovideyou,theoriginalpurchaser,withthisChamberlain
LimitedWarranty.
WealsoprovidethefollowingstatementasrequiredbytheAustralianConsumerLaw:InAustralia,inadditiontoyourrightsunderthisChamberlainLimitedWar-
ranty,ourgoodscomewithguaranteesthatcannotbeexcludedundertheAustralianConsumerLaw.Youareentitledtoareplacementorrefundforamajorfailureand
forcompensationforanyotherreasonablyforeseeablelossordamage.Youarealsoentitledtohavethegoodsrepairedorreplacedifthegoodsfailtobeofacceptable
qualityandthefailuredoesnotamounttoamajorfailure.
Chamberlain’s warranty
Chamberlainwarrantstotheoriginalpurchaserofthelightingorchimeproduct(includinganyLEDlightswhichareprovidedbyChamberlainaspartofthegoods)
(Unit)thattheUnitisfreefromdefectsinmaterialsandworkmanshipforaperiodof12monthsfromthedateofpurchase.
DuringtheapplicableChamberlainLimitedWarrantyperiod,ifyouareconcernedthattheUnitmaybedefective,contactyourretailerwhowillprovideyouwitha
replacementUnitorreferyoutoourservicecentreforafactoryrepairorreplacement.
Ifyourretailerrefersyoutous,callourservicecentreonthetollfreenumberbelowandaChamberlaintechnicianwilldiagnosetheproblem.Oncetheproblemhas
beendiagnosed,subjecttoyourrightsundertheAustralianConsumerLawwithrespecttomajorfailures,Chamberlainwillprovideyouwithshippinginstructions
forafactoryrepairorreplacement.
Ifafactoryrepairorreplacementisrequired,providedthedefectivepartorUnitisreturnedtoChamberlainwell-packagedandinaccordancewithChamberlains
shippinginstructions,Chamberlainwillrepairor,atitsoptionbutsubjecttoyourrightsundertheAustralianConsumerLawwithrespecttomajorfailures,replace
anydefectivepartorUnitandreturnittoyouatnocost.
RepairsandreplacementpartsprovidedunderthisChamberlainLimitedWarrantyareprovidedfreeofchargeandarewarrantedfortheremainingportionofthe
originalwarrantyperiod.
isChamberlainLimitedWarrantyprovidesbenetswhichareinadditiontoyourotherrightsandremediesasaconsumer.
Exclusions
Ifourservicecentredeterminesthatawarrantyclaimhasbeenmadeinrespectofafailureordefectarisingunderoroutofanyexclusiondetailedbelowsuchthatthe
claimisnotcoveredunderthisChamberlainLimitedWarranty,wemay,subjecttoyourotherrightsandremediesasaconsumer,chargeyouafeetorepair,replace
and/orreturntheUnittoyou.
Exclusions
isChamberlainLimitedWarrantydoesnotcoveranyfailureof,ordefectin,theUnitdueto:
1. non-compliancewiththeinstructionsregardinginstallation,operation,maintenanceandtestingoftheUnitorofanyproductwithwhichtheUnitisused;
2. anyattemptbyapersonotherthananauthorisedinstallertorepair,dismantle,reinstallormovetheUnittoanotherlocationonceithasbeeninstalled;
3. tampering,neglect,abuse,wearandtear,accident,electricalstorm,excessiveuseorconditionsotherthannormaldomesticuse;
4. problemscausedbyelectricalfaultsorreplacementofbatteriesorlightbulbs;
5. submersioninwaterorotheruids;
6. powersupplygreaterorlessthanwhatisspecied;
7. useofalightbulbwithahigherwattagethanthatspecied;or
8. forchimesproducts,radiointerferencefromanotherradiofrequencyappliance.
IfthisChamberlainLimitedWarrantydoesnotapply,youmayhaverightsavailabletoyouundertheAustralianConsumerLaw.
Liability – Australia only
ExceptassetoutintheAustralianConsumerLaw(beingSchedule2ofthe
Competition and Consumer Act 2010
)(asamended,consolidatedorreplaced):
1. allotherguarantees,warrantiesandrepresentationsinrelationtotheUnitoritssupplyareexcludedtotheextentthatChamberlaincanlawfullyexcludethem;
and
2. undernocircumstanceswillChamberlainbeliableforconsequential,incidentalorspecialdamagesarisinginconnectionwiththeuse,orinabilitytouse,theUnit,
otherthanthosewhichwerereasonablyforeseeableasliabletoresultfromthefailure.
Liability – New Zealand only
Exceptassetoutinthe
Fair Trading Act 1986
andthe
Consumer Guarantees Act 1993
(asamended,consolidatedorreplaced):
1. allotherguarantees,warrantiesandrepresentationsinrelationtotheUnitoritssupplyareexcludedtotheextentthatChamberlaincanlawfullyexcludethem;
and
2. undernocircumstanceswillChamberlainbeliableforconsequential,incidentalorspecialdamagesarisinginconnectionwiththeuse,orinabilitytouse,theUnit,
otherthanthosewhichwerereasonablyforeseeableasliabletoresultfromthefailure.
Note
Werequestthatyouretainyoursalesdocketorinvoiceasproof-of-purchaseandattachittothismanualtoenableyoutoestablishthedateofpurchaseintheunlikely
eventofawarrantyservicebeingrequired.ChamberlainreservestherighttochangethedesignandspecicationsoftheUnitwithoutpriornotication.Somefeatures
oraccessoriesoftheUnitmaynotbeavailableincertainmarketsorareas.Pleasecheckwithyourretailer.
Chamberlain service centre contact details
Australia New Zealand
Phonetollfree1800638234 Aucklandphone094772823
Faxtollfree1800888121 Phonetollfree0800653667
Email:[email protected] Faxtollfree0800653663
Chamberlain Australia Pty. Ltd. Chamberlain New Zealand Limited
Unit 3, 7-9 Orion Rd 17A Arrenway Drive, Albany
Lane Cove NSW 2066 Auckland
(P.O. Box 1446, Lane Cove, NSW 1595) (PO Box 100221 North Shore 0745)
Website
www.chamberlainanz.com
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8

Chamberlain Secure Home SH-9150AU Installation And Operating Instructions Manual

Type
Installation And Operating Instructions Manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI