Coolair CPL450 Owner's manual

Category
Mobile air conditioners
Type
Owner's manual

This manual is also suitable for

(English) (CPL)
OWNER’SMANUAL
CPL EvaporativeCooler
®
ILL1456-A
1CPL EvaporativeCooler
®
Introduction
WallControlFunctions
DrainValve&BleedSystem
Maintenance
Troubleshooting
8
7
3
2
10
2
SEELEY INTERNATIONAL – OWNER’SMANUAL
INTRODUCTION
Congratulationsonchoosinga
newCoolaircoolerforyour
home.
Yourcoolerisbuiltfromthe
highestqualitymaterialsand
engineeredtoprovidemany
yearsofeconomical,troublefree
cooling.
Pleasetakeafewminutesto
readtheseinstructionssoyou
haveafullunderstandingofhow
tooperateyourcooler. Your
installershoulddemonstratethe
featuresandproceduressetout
intheseinstructions. The
installershouldalsoprovideyou
withaModelandSerialnumber,
whichcanbefilledoutonthe
lastpage.
Keeptheseinstructionsina
safeplaceforfuturereference.
Thisapplianceisnotintendedfor
usebypersons(including
children)withreducedphysical,
sensoryormentalcapabilities,or
lackofexperienceand
knowledge,unlesstheyhave
beengivensupervisionor
instructionconcerninguseofthe
appliancebyaperson
responsiblefortheirsafety.
Childrenshouldbesupervisedto
ensurethattheydonotplaywith
theappliance.
EFFECTIVECOOLING
Toprovideefficientcoolingor
ventilationthebuildingmusthave
sufficientexhaustopeningsto
outdoorsintheformofdoors,
windowsorothervents. Toassistair
circulation,openwindowsordoors
thatarefurthestfromtheoutletvent
ineachroom.Ineveryroomthathas
anoutletvent,provideanexhaust
openingabout2or2.5timesthevent
sizeoftheroom.Wherethedesign
ofthebuildingpreventsadequate
exhaust,considerationshouldbe
giventotheprovisionofmechanical
extractionsuchasanexhaustfan.
Totalminimumopeningsforthe
wholebuildingaredemonstratedby
thefollowingtable:
Pleasenotethatanaveragesizedooris1.5m2
CoolerModel ExhaustOpening
2.0m2
CPL450
CPL600
CPL700
CPL850
CPL1000
CPL1100
2.5m2
2.5m2
3.0m2
4.0m2
4.0m2
1CPL EvaporativeCooler
®
Introduction
WallControlFunctions
DrainValve&BleedSystem
Maintenance
Troubleshooting
8
7
3
2
10
2
SEELEY INTERNATIONAL – OWNER’SMANUAL
INTRODUCTION
Congratulationsonchoosinga
newCoolaircoolerforyour
home.
Yourcoolerisbuiltfromthe
highestqualitymaterialsand
engineeredtoprovidemany
yearsofeconomical,troublefree
cooling.
Pleasetakeafewminutesto
readtheseinstructionssoyou
haveafullunderstandingofhow
tooperateyourcooler. Your
installershoulddemonstratethe
featuresandproceduressetout
intheseinstructions. The
installershouldalsoprovideyou
withaModelandSerialnumber,
whichcanbefilledoutonthe
lastpage.
Keeptheseinstructionsina
safeplaceforfuturereference.
Thisapplianceisnotintendedfor
usebypersons(including
children)withreducedphysical,
sensoryormentalcapabilities,or
lackofexperienceand
knowledge,unlesstheyhave
beengivensupervisionor
instructionconcerninguseofthe
appliancebyaperson
responsiblefortheirsafety.
Childrenshouldbesupervisedto
ensurethattheydonotplaywith
theappliance.
EFFECTIVECOOLING
Toprovideefficientcoolingor
ventilationthebuildingmusthave
sufficientexhaustopeningsto
outdoorsintheformofdoors,
windowsorothervents. Toassistair
circulation,openwindowsordoors
thatarefurthestfromtheoutletvent
ineachroom.Ineveryroomthathas
anoutletvent,provideanexhaust
openingabout2or2.5timesthevent
sizeoftheroom.Wherethedesign
ofthebuildingpreventsadequate
exhaust,considerationshouldbe
giventotheprovisionofmechanical
extractionsuchasanexhaustfan.
Totalminimumopeningsforthe
wholebuildingaredemonstratedby
thefollowingtable:
Pleasenotethatanaveragesizedooris1.5m2
CoolerModel ExhaustOpening
2.0m2
CPL450
CPL600
CPL700
CPL850
CPL1000
CPL1100
2.5m2
2.5m2
3.0m2
4.0m2
4.0m2
3CPL EvaporativeCooler
®
STARTING YOURCOOLER
TheON/OFFbuttonturnstheaircooler
onandoff.
Therearetwomodesofoperationto
choosefrom, Automaticmodeor
Manualmode.Whentheaircooleris
turnedon,itwillstartinthemodeof
operationitwasinwhenlastturnedoff.
Ifyouraircoolerhasnotbeenoperated
forawhile,thenwhenyoustartit, “Pre
CoolCycle” maysometimesflashon
thedisplayasshown. Thisindicates
thatthewaterpumpwilloperateto
saturatethecoolingpadsforafew
minutesbeforethefanisturnedon.
Thisistoensurethatwhenthefan
starts,onlycoolairentersthebuilding.
ILL1085-A
4SEELEY INTERNATIONAL – OWNER’SMANUAL
AUTOMATICMODE
MANUAL MODE
The AUTObuttonisusedtoselect
AutomaticmodeorManualmode.
When “Auto” isdisplayedthecooleris
under Automaticcontrolandwill
operateaccordingtothetemperature
sensedatthewallcontrol.
Whentheaircooleristurnedon,itwill
readthetemperatureandsetthe
cooleroperationaccordingly.Ifthe
temperatureincreasesatthewall
control,thenthefanspeedwill
increase. Asthetemperature
decreasesthefanspeedwilldecrease
untilthecoolerturnsoff.
Pressortooveridethe
automaticcoolinglevelsettingand
adjustyourroomtemperature.
ToswitchtoManualmode,press
AUTOuntil “Man” appearsinthe
display.InManualmodethecooling
levelcanbemanuallyadjusted.
InManualmode,press to
choosebetweencirculatingcoolairor
uncooledair.When “Cool” is
displayed,freshcoolairwillcirculate
intothebuilding.When “Vent” is
displayedasshown,freshuncooled
airwillcirculatethroughthebuilding.
Presstoincreasethefanspeed
andcirculatemoreair.Pressto
decreasethefanspeedandcirculate
lessair.Pressoncetochangethe
speedbyoneincrement.Holdthe
buttondowntochangethespeed
morequickly.
COOL
AUTOMATICMODEDISPLAY
MANUAL MODEDISPLAY
3CPL EvaporativeCooler
®
STARTING YOURCOOLER
TheON/OFFbuttonturnstheaircooler
onandoff.
Therearetwomodesofoperationto
choosefrom, Automaticmodeor
Manualmode.Whentheaircooleris
turnedon,itwillstartinthemodeof
operationitwasinwhenlastturnedoff.
Ifyouraircoolerhasnotbeenoperated
forawhile,thenwhenyoustartit, “Pre
CoolCycle” maysometimesflashon
thedisplayasshown. Thisindicates
thatthewaterpumpwilloperateto
saturatethecoolingpadsforafew
minutesbeforethefanisturnedon.
Thisistoensurethatwhenthefan
starts,onlycoolairentersthebuilding.
ILL1085-A
4SEELEY INTERNATIONAL – OWNER’SMANUAL
AUTOMATICMODE
MANUAL MODE
The AUTObuttonisusedtoselect
AutomaticmodeorManualmode.
When “Auto” isdisplayedthecooleris
under Automaticcontrolandwill
operateaccordingtothetemperature
sensedatthewallcontrol.
Whentheaircooleristurnedon,itwill
readthetemperatureandsetthe
cooleroperationaccordingly.Ifthe
temperatureincreasesatthewall
control,thenthefanspeedwill
increase. Asthetemperature
decreasesthefanspeedwilldecrease
untilthecoolerturnsoff.
Pressortooveridethe
automaticcoolinglevelsettingand
adjustyourroomtemperature.
ToswitchtoManualmode,press
AUTOuntil “Man” appearsinthe
display.InManualmodethecooling
levelcanbemanuallyadjusted.
InManualmode,press to
choosebetweencirculatingcoolairor
uncooledair.When “Cool” is
displayed,freshcoolairwillcirculate
intothebuilding.When “Vent” is
displayedasshown,freshuncooled
airwillcirculatethroughthebuilding.
Presstoincreasethefanspeed
andcirculatemoreair.Pressto
decreasethefanspeedandcirculate
lessair.Pressoncetochangethe
speedbyoneincrement.Holdthe
buttondowntochangethespeed
morequickly.
COOL
AUTOMATICMODEDISPLAY
MANUAL MODEDISPLAY
5CPL EvaporativeCooler
®
TIMED AUTOMATICSTART
TIMED AUTOMATICSTOP
Youcansettheaircoolersothatitwill
turnonafterasetnumberofhours.
1.Tosetthedelayedstarttime,press
withthecoolerturnedOFF.
“Startingin” willbedisplayedasshown
withthelastmodeofoperation(Manual
or Automatic).
2.Ifyouwanttheaircoolertoturnonin
Automaticmodewiththeprevious
settings,thenpress until “Auto”
isdisplayed. Alternatively,ifyouwant
theaircoolertoturnoninManual
mode,press until “Man” is
displayedandthenpress and
thenortosettherequiredfan
speed.
3.Tosetthetimeuntilthestart,press
.
4.Thenpressortoadjustthe
time. Thecoolercanstartupto24
hoursinadvance.
5.Press againtoinitiatethe
timedautomaticstart. Thetimedstart
willnotrepeat.
Youcanalsosettheaircoolersothatit
willturnoffafterasetnumberofhours.
1.Tosetadelayedstoptime,press
withthecoolerrunning.
”Stoppingin” willdisplay.
TIMER
AUTO
AUTO
COOL
TIMER
TIMER
TIMER
2.Pressortoadjustthe
numberofhoursbeforetheair
coolerwillstop. Themaximum
delaysettingis24hours.
3.Press againtobegin
thetimedstop.
TIMER
6SEELEY INTERNATIONAL – OWNER’SMANUAL
USINGTHECOOLER
Nowthatyouhavereadthese
instructions,pressthe
buttontoturnyouraircooleron.If
theaircoolerhasnotoperatedfor
awhile, “PreCoolCycle” willflash
onthedisplay. The “PreCoolCycle
willbeginandwilltakeonlyafew
minutestocomplete. Afterthis
time,thefanwillcomeon
automatically,andyoucanenjoy
thecomfortofcoolfreshair!
POWER AIRTOOCOLD
Withthecoolerrunningin Automatic
mode,youmayfindthatyouaretoo
coldorthattheaircoolerisblowing
toomuchair.Presstolowerthe
automatictemperaturesettingand
reducetheamountofcooling.
Ifyouaretoocoldwiththecooler
runninginManualmode,thenpress
toreducethefanspeed. Youcan
alsocirculatefreshuncooledairby
pressing until Ventdisplays.COOL
AIRNOTCOLDENOUGH
Youmayfindthatwiththeaircooler
runningin Automaticmode,youare
notcoolenough.Simplypressto
increasethecoolingrate.
Ifyouarenotcoolenoughwiththe
aircoolerrunninginManualmode,
thenpresstoincreasethefan
speed.Ensurethatcooledairis
circulatingbypressing until
Cooldisplays.
COOL
Youcanexperimentwiththe
settingsonyourwallcontrol.
Thisisthebestwaytogetthe
mostfromyouraircooler.
5CPL EvaporativeCooler
®
TIMED AUTOMATICSTART
TIMED AUTOMATICSTOP
Youcansettheaircoolersothatitwill
turnonafterasetnumberofhours.
1.Tosetthedelayedstarttime,press
withthecoolerturnedOFF.
Startinginwillbedisplayedasshown
withthelastmodeofoperation(Manual
or Automatic).
2.Ifyouwanttheaircoolertoturnonin
Automaticmodewiththeprevious
settings,thenpress until Auto
isdisplayed. Alternatively,ifyouwant
theaircoolertoturnoninManual
mode,press until Manis
displayedandthenpress and
thenortosettherequiredfan
speed.
3.Tosetthetimeuntilthestart,press
.
4.Thenpressortoadjustthe
time. Thecoolercanstartupto24
hoursinadvance.
5.Press againtoinitiatethe
timedautomaticstart. Thetimedstart
willnotrepeat.
Youcanalsosettheaircoolersothatit
willturnoffafterasetnumberofhours.
1.Tosetadelayedstoptime,press
withthecoolerrunning.
Stoppinginwilldisplay.
TIMER
AUTO
AUTO
COOL
TIMER
TIMER
TIMER
2.Pressortoadjustthe
numberofhoursbeforetheair
coolerwillstop. Themaximum
delaysettingis24hours.
3.Press againtobegin
thetimedstop.
TIMER
6SEELEY INTERNATIONAL – OWNERSMANUAL
USINGTHECOOLER
Nowthatyouhavereadthese
instructions,pressthe
buttontoturnyouraircooleron.If
theaircoolerhasnotoperatedfor
awhile, PreCoolCyclewillflash
onthedisplay. The PreCoolCycle
willbeginandwilltakeonlyafew
minutestocomplete. Afterthis
time,thefanwillcomeon
automatically,andyoucanenjoy
thecomfortofcoolfreshair!
POWER AIRTOOCOLD
Withthecoolerrunningin Automatic
mode,youmayfindthatyouaretoo
coldorthattheaircoolerisblowing
toomuchair.Presstolowerthe
automatictemperaturesettingand
reducetheamountofcooling.
Ifyouaretoocoldwiththecooler
runninginManualmode,thenpress
toreducethefanspeed. Youcan
alsocirculatefreshuncooledairby
pressing until Ventdisplays.COOL
AIRNOTCOLDENOUGH
Youmayfindthatwiththeaircooler
runningin Automaticmode,youare
notcoolenough.Simplypressto
increasethecoolingrate.
Ifyouarenotcoolenoughwiththe
aircoolerrunninginManualmode,
thenpresstoincreasethefan
speed.Ensurethatcooledairis
circulatingbypressing until
Cooldisplays.
COOL
Youcanexperimentwiththe
settingsonyourwallcontrol.
Thisisthebestwaytogetthe
mostfromyouraircooler.
7CPL EvaporativeCooler
®
Thiscoolercomeswithastandard
bleedsystemortheoptionalautomatic
DrainValve.
STANDARDBLEEDSYSTEM
Duringoperation,thebleedsystemwill
drainsmallamountsofwater. This
ensuresfreshwateriscontinually
addedtodilutesaltaccumulationinthe
watercausedthroughevaporation. This
helpskeeptheaircooleringood
conditionandensureoptimum
performance. Thebleedratewill
dependonlocaloperatingconditions
andwillbesetbytheinstaller.
AUTOMATICDRAIN
VALVE
Ifthedrainvalvewasinstalled
insteadofthestandardbleed
systemthenyourcoolerwill
automaticallydrainafteraset
timeofcontinuousoperation.
Thisensuresthewateris
alwaysfreshandhelps
maintainyourcooleringood
conditiontoensureoptimum
coolingperformance. The
frequencyoftheautomatic
drainmayhavebeenadjusted
byyourinstalleraccordingto
thegeneralwaterqualityinyour
area.
Whenthecooleristurnedofffor
72hours,thedrainvalvewill
openautomaticallyandempty
waterfromthecooler.Whenthe
cooleristurnedonagain,fan
operationwilldelayforafew
minuteswhilethetankrefills
andthecoolingpadsare
saturatedagain.
Atanytimewhenthe
thermostatisOFF,youcan
drainthecoolerbypressing
andholdingsandtfor1
second. Thedisplaywillshow
drtoconfirmtheoperationhas
activated.
8SEELEY INTERNATIONAL – OWNERSMANUAL
MAINTENANCE
HEALTHREGULATIONS
ENDOFSEASONSERVICE
Regularmaintenanceisessentialto
ensurethecooleroperatesefficiently
formanyyears.Servicesmustbe
performedbeforeandafterthe
summerseason.Morefrequent
servicingmayberequiredindusty
conditionsorinareaswithpoorwater
quality.
Notethatsomeregulatingauthorities
requireservicestobeconductedat
specificintervals.
Turnoffthepowersupplytothe
cooler.
Turnoffthewatersupplytothe
cooler.
Removethepadframesasshown.
A. Turnoffthepowerswitchinside
thecooler.
B. Checkandcleanthelidwater
channels.
C. Iffitted,firstunclipandthen
removethebleedsystemasshown.
Allowthetankwatertodrain.Donot
losetheo-ring.
Thoroughlycleanthetankandpump
filter.
WARNING:Werecommend
maintenanceiscarriedoutbyan
authorisedserviceagent.Climbing
ontotheroofishazardousandcan
resultinpersonalinjuryorproperty
damage.Failuretocarryout
maintenancewillaffectyour
warrantycoverage.
A
B
C
Donotreplacethebleedsystem.
(IfaDrainValveisfitteditwill
automaticallydrain.)
Re-fitthepadframes.
7CPL EvaporativeCooler
®
Thiscoolercomeswithastandard
bleedsystemortheoptionalautomatic
DrainValve.
STANDARDBLEEDSYSTEM
Duringoperation,thebleedsystemwill
drainsmallamountsofwater. This
ensuresfreshwateriscontinually
addedtodilutesaltaccumulationinthe
watercausedthroughevaporation. This
helpskeeptheaircooleringood
conditionandensureoptimum
performance. Thebleedratewill
dependonlocaloperatingconditions
andwillbesetbytheinstaller.
AUTOMATICDRAIN
VALVE
Ifthedrainvalvewasinstalled
insteadofthestandardbleed
systemthenyourcoolerwill
automaticallydrainafteraset
timeofcontinuousoperation.
Thisensuresthewateris
alwaysfreshandhelps
maintainyourcooleringood
conditiontoensureoptimum
coolingperformance. The
frequencyoftheautomatic
drainmayhavebeenadjusted
byyourinstalleraccordingto
thegeneralwaterqualityinyour
area.
Whenthecooleristurnedofffor
72hours,thedrainvalvewill
openautomaticallyandempty
waterfromthecooler.Whenthe
cooleristurnedonagain,fan
operationwilldelayforafew
minuteswhilethetankrefills
andthecoolingpadsare
saturatedagain.
Atanytimewhenthe
thermostatisOFF,youcan
drainthecoolerbypressing
andholdingsandtfor1
second. Thedisplaywillshow
drtoconfirmtheoperationhas
activated.
8SEELEY INTERNATIONAL – OWNERSMANUAL
MAINTENANCE
HEALTHREGULATIONS
ENDOFSEASONSERVICE
Regularmaintenanceisessentialto
ensurethecooleroperatesefficiently
formanyyears.Servicesmustbe
performedbeforeandafterthe
summerseason.Morefrequent
servicingmayberequiredindusty
conditionsorinareaswithpoorwater
quality.
Notethatsomeregulatingauthorities
requireservicestobeconductedat
specificintervals.
Turnoffthepowersupplytothe
cooler.
Turnoffthewatersupplytothe
cooler.
Removethepadframesasshown.
A. Turnoffthepowerswitchinside
thecooler.
B. Checkandcleanthelidwater
channels.
C. Iffitted,firstunclipandthen
removethebleedsystemasshown.
Allowthetankwatertodrain.Donot
losetheo-ring.
Thoroughlycleanthetankandpump
filter.
WARNING:Werecommend
maintenanceiscarriedoutbyan
authorisedserviceagent.Climbing
ontotheroofishazardousandcan
resultinpersonalinjuryorproperty
damage.Failuretocarryout
maintenancewillaffectyour
warrantycoverage.
A
B
C
Donotreplacethebleedsystem.
(IfaDrainValveisfitteditwill
automaticallydrain.)
Re-fitthepadframes.
9CPL EvaporativeCooler
®
PRE-SEASONSERVICE
REMOVAL OFPADFRAMES
Turnoffthepowersupplytotheair
cooler
Removethepadframesasshown.
Ensurethepowerswitchinthecooler
isoff.
Gentlywashthepadstoremoveany
dustbuildupduringthewinterperiod.If
thepadsareinpoorcondition,replace
them.
Replacethebleedsystemifitwas
removedduringpreviousmaintenance
andensuretheo-ringisfitted.(Ifthe
coolerisfittedwithadrainvalvethiswill
notbenecessaryasitwillautomatically
closewhenthecoolerturnson).
Turnonthepowerswitchinsidethe
cooler.
Turnonthewaterandthenthepower.
Re-fitthepadframesandrunthe
cooler.
Toremoveapadframe,insertaflat
screwdrivertipintotheslotasshown
andleveruntildisengagementoccurs.
Takeholdofthepadframeandpullit
towardsyouuntiltheinternalsideclips
disengage.
Pivotthepadframeoutwardsandlift
up. Takecarenottodamagethepad.
Repeatthesestepsfortheremaining
padframes.
IMPORTANT:Donotdamagethe
padswithhighpressurewaterspray.
WARNING:Donotruntheaircooler
withthepadframesremoved.
10SEELEY INTERNATIONAL – OWNERSMANUAL
PROBLEM – UnpleasantOdour
CAUSE ACTION
1. Odourfromnewpads. Allowtimetoconditionbyrunningthe
aircooler.
PROBLEM – InadequateCooling
CAUSE ACTION
1. Drypads. Checkwaterflowtopads.
Inspectfitmentofdistributorcap.
Checkforblockedorkinkedhose.If
blocked,dismantle,cleanandflushor
unkinkthehose.
2. Insufficientexhaust
openingsforconditioned
air.
Ensuresufficientopenings.Referto
chartonPg.2
3. Excessiveambient
humidity
(SeealsoInsufficient
exhaust)
Ondayswheretheambienthumidity
ishigh,thecoolerwillnotreducethe
temperatureasmuchasondrier
days.
IfyourwallcontroldisplaysSERVICEorshouldyouconsiderthatyour
coolerrequiresservice,contactyourlocalDealerortheServicenumberon
thebackofthismanual.
TROUBLE-SHOOTINGGUIDE
9CPL EvaporativeCooler
®
PRE-SEASONSERVICE
REMOVAL OFPADFRAMES
Turnoffthepowersupplytotheair
cooler
Removethepadframesasshown.
Ensurethepowerswitchinthecooler
isoff.
Gentlywashthepadstoremoveany
dustbuildupduringthewinterperiod.If
thepadsareinpoorcondition,replace
them.
Replacethebleedsystemifitwas
removedduringpreviousmaintenance
andensuretheo-ringisfitted.(Ifthe
coolerisfittedwithadrainvalvethiswill
notbenecessaryasitwillautomatically
closewhenthecoolerturnson).
Turnonthepowerswitchinsidethe
cooler.
Turnonthewaterandthenthepower.
Re-fitthepadframesandrunthe
cooler.
Toremoveapadframe,insertaflat
screwdrivertipintotheslotasshown
andleveruntildisengagementoccurs.
Takeholdofthepadframeandpullit
towardsyouuntiltheinternalsideclips
disengage.
Pivotthepadframeoutwardsandlift
up. Takecarenottodamagethepad.
Repeatthesestepsfortheremaining
padframes.
IMPORTANT:Donotdamagethe
padswithhighpressurewaterspray.
WARNING:Donotruntheaircooler
withthepadframesremoved.
10SEELEY INTERNATIONAL – OWNERSMANUAL
PROBLEM – UnpleasantOdour
CAUSE ACTION
1. Odourfromnewpads. Allowtimetoconditionbyrunningthe
aircooler.
PROBLEM – InadequateCooling
CAUSE ACTION
1. Drypads. Checkwaterflowtopads.
Inspectfitmentofdistributorcap.
Checkforblockedorkinkedhose.If
blocked,dismantle,cleanandflushor
unkinkthehose.
2. Insufficientexhaust
openingsforconditioned
air.
Ensuresufficientopenings.Referto
chartonPg.2
3. Excessiveambient
humidity
(SeealsoInsufficient
exhaust)
Ondayswheretheambienthumidity
ishigh,thecoolerwillnotreducethe
temperatureasmuchasondrier
days.
IfyourwallcontroldisplaysSERVICEorshouldyouconsiderthatyour
coolerrequiresservice,contactyourlocalDealerortheServicenumberon
thebackofthismanual.
TROUBLE-SHOOTINGGUIDE
seeleyinternational.com AU1110
834962-H
Affixserial&model
number kerherestic
WarrantyService
Australia1-300-650-644
seeleyinternational.com
ItisthepolicyofSeeleyInternationaltointroducecontinual
productimprovement. Accordingly,specificationsare
subjecttochangewithoutnotice.Pleaseconsultwithyour
dealertoconfirmthespecificationsofthemodelselected.
WhenyoucontactyourDealerregardingservice
orwarrantypleasequotethecoolermodel
numberandserialnumberasshownbelow.
®
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12

Coolair CPL450 Owner's manual

Category
Mobile air conditioners
Type
Owner's manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI