Soyal AR-401-IO-1709R Owner's manual

  • Hello! I'm a chat assistant, and I've reviewed the datasheet for the SOYAL AR-401-IO-1709R Access Control System. This document outlines the system's impressive features, such as its fire alarm integration, RS485 communication capabilities and specialized firmware for various access control applications. I'm ready to answer any questions you have about this device.
  • What communication protocols does the AR-401-IO-1709R support?
    What is the purpose of the fire alarm input?
    What kind of power supply is required?
    How many digital inputs and relay outputs does this product have?
SOYAL
ACCESS CONTROL SYSTEM
®AR-401-IO-1709R
V210910
RX2TX2TX RXPWR
ON
1 1 1 1 1 1 1 1 1
222222222 111111111
222222222333344445555
Relay
K30
Relay
K3
Relay
K1
Relay
K4
Relay
K6
Relay
K2
Relay
K5
Relay
K7
Relay
K8
CN1 CN2 CN4 CN3 CN5 CON11
CON3 CON4 CON5 CON6 CON7 CON8 CON9 CON10CON15
CON12 CON13 CON14
AR-401-IO-1709R
1 2 3 4 5 6 7 8
Contents Features
1Product
Specication
PIN Assignments
Built-in re alarm input, when access control is in use, automatically release open all linked
electric lock to ensure safety of personnel
RS485 communication, at the same time support Modbus RTU and SOYAL Protocol, suitable
for both access control system and industrial control
Provides a specialized firmware for different applciations, such as standard I/O control,
multi-door interlocking, and crowd counting firmware; in which can easily meets various
applications
SCADA control function: Access Control SCADA (701Server/Client) with database system
supported.
Interface
Serial port
Baud Rate
Input/Output
Protocol
LED Indicator
Watchdog function
Surge protection
Operating Temperature
Fuses
Noise Isolation
Power Supply
Power Consumption
Dimension(mm)
Weight(g)
OS Supported
Software
RS485 X 2 port
9600,19200 bps (N,8,1)
17 Digital Input/9 Relay Output (Form C)
Modbus, Soyal protocol
Power,Tx/Rx, D.O./D.I
Yes
-20 ~ +70
Power and RS485 Isolation protection
Input optical isolation
9-24 VDC
<4W
455±10(PCB Only)
Windows 7/8/10, Win Server 2008/2012/2016
701Server, 701Client, Commview.exe
400W peak power dissipation.
Clamping time < 1 picosecond (theoretical)
Power: bi-directional avalanche breakdown device.
RS485 bi-directional avalanche breakdown device.
PCB:191(W)x100(H)x20(D)
Panel Mounting Base :225(W)x97(H)x44(D)
Metal Box:231(W)x180(H)x62(D)
CN1
CN3
CN2
CN4
Function
External Port 1
(RS-485 input)
Function
External Port 2
(RS-485 input)
Function
Fire Detection
Input
Pin
1
2
Pin
1
2
Pin
1
2
Description
A+
B-
Description
A+
B-
Description
COM
DI-F
Function
Main Power Supply (Single
Power Supply Mode)
(DC12V/1W)
Pin
1
2
Description
V12
V0
Function
Power input
(DC12V/1W)
Pin
1
2
Description
V12
V0
Function
Relay output
K1~K8
Pin
1
2
Description
N.O.
or
N.C.
COM
CON3~10CN5
CON11
CON12
CON13
CON14
Function
Relay output K30
(Fire Detection Input)
Pin
1
2
Description
N.O. or N.C.
COM
Function
DI input
Function
DI input
Function
DI input
Function
DI input
Pin
1
2
3
4
5
Pin
1
2
3
4
5
Pin
1
2
3
4
5
Pin
1
2
3
4
5
Description
DI.1
DI.2
DI.3
DI.4
COM
Description
DI.5
DI.6
DI.7
DI.8
COM
Description
DI.9
DI.10
DI.11
DI.12
COM
Description
DI.13
DI.14
DI.15
DI.16
COM
CON15
701ClientSQL Graphic Animation I/O mapping
starts from 00(Physical IO Address DI1 -->Symbol IO
Nr.:00, Physical IO Address DI16 -->Symbol IO Nr.:15)
(This version is compatible for hardware with serial number AQI06 and before)
V210910
RS485
CH2
RS485
CH1
Power
Power
Fire
1
ON
23 45 67 8
K1
K30
K2
K3
K4
K5
K6
K7
K8
DI13~16
DI9~12
DI5~8
DI1~4
X9
N.C.
N.O.
Relay
COM
DI.4
DI.3
DI.2
DI.1
COM
DI.8
DI.7
DI.6
DI.5
COM
DI.12
COM
DI.11
DI.10
DI.9
DI.16
COM
N.O./N.C.
COM
N.O./N.C.
COM
N.O./N.C.
COM
N.O./N.C.
COM
N.O./N.C.
COM
N.O./N.C.
COM
N.O./N.C.
COM
N.O./N.C.
COM
DI.15
DI.14
DI.13
Vin-
Vin+
Vin-
Vin+
COM
DI-F
A+
B-
A+
B-
17-CH Optical Coupling DI /
9-CH Relay Output Module
Wiring Diagram
Standard Firmware-- Dip Switch Setting
8 Interlock Door Solution-- Dip Switch Setting
Use binary to calculate Node Number
Use binary to calculate Node Number
Door lock output relay time
Alarm output relay time
3 seconds
3 seconds
6 seconds
6 seconds
9 seconds
9 seconds
15 seconds
Latch
Node ID (# 1~127)
L 1 2 3 4 5 6 7 8 H L 1 2 3 4 5 6 7 8 H L 1 2 3 4 5 6 7 8 H L 1 2 3 4 5 6 7 8H L 1 2 3 4 5 6 7 8H L 1 2 3 4 5 6 7 8 HL 1 2 3 4 5 6 7 8 H
N.O. N.C.
ON ON ON ONON ON ON
BAUD19200BAUD9600
Example : Node 1 Example : Node 2 Example : Node 64
N.C./N.O. Type witch
Node ID (Range 1~64; 000 equivalent to Node ID 64)
Example: Node 1 Example:Node 2 Example : Node 16
L 1 2 3 4 5 6 7 8 H L 1 2 3 4 5 6 7 8 H L 1 2 3 4 5 6 7 8 H
L 1 2 3 4 5 6 7 8H
L 1 2 3 4 5 6 7 8H
L 1 2 3 4 5 6 7 8H
L 1 2 3 4 5 6 7 8H
L 1 2 3 4 5 6 7 8 H
L 1 2 3 4 5 6 7 8 H
L 1 2 3 4 5 6 7 8 H
L 1 2 3 4 5 6 7 8 H
ON ON ON ON
ON ON ON ON
ON ON ON
Node ID (# 1~16)
/