Skil ME981901 Owner's manual

Category
Distance meters
Type
Owner's manual
1-877-SKIL-999
OR
www.skiltools.com
WARNING: To reduce the risk of injury, the user must read and understand the
Operator’s Manual before using this product. Save these instructions for future reference.
AVERTISSEMENT : Afin de réduire les risques de blessure, l’utilisateur doit lire et
comprendre le guide d’utilisation avant d’utiliser cet article. Conservez le présent guide
afin de pouvoir le consulter ultérieurement.
ADVERTENCIA : Para reducir el riesgo de lesiones, el usuario debe leer y comprender
el Manual del operador antes de utilizar este producto. Guarde estas instrucciones para
consultarlas en caso sea necesario.
Owner’s Manual
Guide d’utilisation
Manual del propietario
For Customer Service
Pour le service à la clientèle
Servicio al cliente
Model/ Modelo/ Modèle: #ME981901
100ft Laser Distance Measurer & Level
Mesure de distances jusqu’à 100 pi et niveau
Medidor de distancia y nivel láser hasta 100 pies
2
TABLE OF CONTENTS
General Laser Tool Safety Warnings .................3-4
FCC Statement ...................................4-5
Safety Rules Of Connecting External Power Tool ........5
Symbols ........................................6-9
Get to Know Your Laser Tool ..................... 10-11
Packing List ......................................11
Specications ....................................12
Operating Instructions ..........................13-26
Maintenance ......................................27
Trouble Shooting ............................... 28-29
Limited Warranty Of Skil Consumer Tools .............31
3
GENERAL LASER TOOL SAFETY WARNINGS
READ ALL INSTRUCTIONS BEFORE USING THE
TOOL!
WARNING
LASER
RADIATION.
Do
not stare into beam. Class II laser
product. Turn the laser beam on only
when using this tool.
Do not remove or deface any
product labels.
Avoid direct eye exposure.
The laser
beam can cause ash blindness.
Do not operate the tool around children
or allow children to operate the tool.
Do not
place the tool in a position
that may cause anyone to stare at the
laser beam, whether intentionally or
unintentionally.
Do not use on surfaces such as
sheet steel that have shiny, reective
surfaces. The shiny surface could
reect the beam back at the operator.
Always turn the laser tool off
when not in use.
Leaving the tool
on increases the risk of someone
inadvertently staring into the laser
beam.
Do not attempt to modify the
performance of this laser device in any
way. This may result in a dangerous
exposure to laser radiation.
CAUTION/PRECAUCIÓN/ATTENTION
AVOID EXPOSURE/EVITE LA EXPOSICIÓN/
ÉVITEZ L’EXPOSITION
LASER RADIATION IS EMITTED FROM THIS
APERTURE
LA RADIACIÓN LÁSER SE EMITE DE ESTA
ABERTURA
CET OUTIL PRODUIT UN RAYONNEMENT LASER
LASER RADIATION-DO NOT STARE
INTO BEAM
RADIACIÓN LÁSER: NO MIRE
DIRECTAMENTE EL RAYO
RAYONNEMENT LASER – NE FIXEZ
PAS DES YEUX LE RAYON LASER
CAUTION: Risk of re and burns. Do not open,
crush, heat above 100° C (212° F) or incinerate.
PRECAUCIÓN : Riesgo de incendio y
quemaduras. No abra, triture, permita que esté a
mayor temperatura que 100° C (212 °F) ni
incinere.
ATTENTION : Risque d’incendie et de brûlures.
N’ouvrez pas le produit, ne l’écrasez pas, ne le
chauffez pas à plus de 100 ºC (212°F) et ne
l’incinérez pas.
635nm, OUTPUT < 1mW/CLASS II LASER
PRODUCT 3.7V 500mAh Li-Polymer
COMPLIES WITH 21 CFR PARTS 1040.10 AND
1040.11
PRODUCTO LÁSER CON SALIDA < 1mW.
CLASE II, 635nm, 3,7V 500mAh polímero
de litio
CUMPLE CON LAS SECCIONES 21 CFR
1040.10 Y 1040.11
635nm, SORTIE < 1 mW/PRODUIT LASER DE
CLASSE II Pile au lithium-polymère de
3,7 V, 500 mAh
CONFORME AUX NORMES 21CFR ARTICLES
1040.10 ET 1040.11
MADE IN CHINA /
HECHO EN CHINA /
FABRIQUÉ EN CHINE
SERIAL NO./ SERIE NO./ NUMÉRO DE SÉRIE
CAN ICES-3(B)/NMB-3(B)
Model / Modelo /
Modèle: ME981901
1.85Wh
4
Do not attempt to repair or disassemble the tool. If unqualied
persons attempt to repair this product, serious injury may occur. Any
repair required on this laser product should be performed only by
qualied service personnel.
Use of other accessories that have been designed for use with other
laser tools could result in serious injury.
Do not operate the tool outdoors.
Do not place or store tool under extreme temperature conditions.
FCC STATEMENT
The manufacturer is not responsible for radio interference caused
by unauthorized modications to this equipment. Such modications
could void the user’s authority to operate the equipment.
This device complies with Part 15 of the FCC Rules. Operation is
subject to the following two conditions:
(1) This device may not cause harmful interference.
(2) This device must accept any interference received, including
interference that may cause undesired operation.
Changes or modications not expressly approved by the party
responsible for compliance could void the user’s authority to operate
the equipment.
NOTE:
This equipment has been tested and found to comply with
the limits for a Class B digital device, pursuant to Part 15 of the FCC
Rules. These limits are designed to provide reasonable protection
against harmful interference in a residential installation. This
equipment generates, uses, and can radiate radio frequency energy
and, if not installed and used in accordance with the instructions,
may cause harmful interference to radio communications. However,
there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to
radio or television reception, which can be determined by turning
the equipment off and on, the user is encouraged to try to correct
the interference by one or more of the following measures:
5
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from
that to which the receiver is connected.
Consult the dealer or an experienced radio/TV technician for help.
DANGER
People with electronic devices, such as
pacemakers, should consult their physician(s)
before using this product. Operation of electrical equipment in close
proximity to a heart pacemaker could cause interference or failure of
the pacemaker.
SAFETY RULES OF CONNECTING EXTERNAL
POWER TOOL
WARNING
Read and follow all instructions below
before connect with external power supply
such as AC supply and DC mobile power.
Failure to follow all
instructions below may result in electric shock, explosion, re and/or
serious personal injury.
Only choose the qualied and legal adapter which output voltage is
5V and output electricity is ≥0.5A.
Conrm the adapter suits the AC supply before do connecting.
Conrm the mobile power is qualied and legal , the output voltage
is 5V and the output electricity is ≥0.5A before do connecting.
Keep the adapter clean. Check the adapter, cable and plug before
do connecting. If damage is detected, do not use or repair by
yourself, change the damaged one or get repairs performed by
authorized service personnel, otherwise electric shock may occur.
Do not do connecting with AC supply on easily inammable surfaces
(e.g., paper, textiles, etc.) or surroundings. The heating of the
adapter during using may pose a re hazard.
Children or persons with physical, sensory or mental limitations
or lack of experience and knowledge are not capable of securely
operating the adapter unless they are being given supervision or
having been instructed by a responsible person.
6
SYMBOLS
Safety Symbols
The purpose of safety symbols is to attract your attention to
possible dangers. The safety symbols and the explanations with
them deserve your careful attention and understanding. The
symbol warnings do not, by themselves, eliminate any danger. The
instructions and warnings they give are no substitutes for proper
accident prevention measures.
WARNING
Be sure to read and understand all safety
instructions in this Operator’s Manual, including
all safety alert symbols such as “
DANGER
,” “
WARNING
,” and
CAUTION
” before using this tool. Failure to following all instructions
listed below may result in electric shock, re, and/or serious
personal injury.
The denitions below describe the level of severity for each
signal word. Please read the manual and pay attention to these
symbols.
This is the safety alert symbol. It is
used to alert you to potential personal
injury hazards. Obey all safety
messages that follow this symbol to
avoid possible injury or death.
DANGER
DANGER indicates a hazardous
situation which, if not avoided, will
result in death or serious injury.
WARNING
WARNING indicates a hazardous
situation which, if not avoided, could
result in death or serious injury.
7
CAUTION
CAUTION, used with the safety alert
symbol, indicates a hazardous situation
which, if not avoided, will result in
minor or moderate injury.
Damage Prevention And Information Messages
These inform the user of important information and/or instructions
that could lead to equipment or other property damage if they are
not followed. Each message is preceded by the word “NOTICE”, as
in the example below:
NOTICE:
Equipment and/or property damage may result if these
instructions are not followed.
IMPORTANT:
Some of the following symbols may be used on
your tool. Please study them and learn their meaning. Proper
interpretation of these symbols will allow you to operate the tool
better and safer.
Symbol Name Designation/Explanation
V Volts Voltage (potential)
A Amperes Current
mW Milliwatt Power
kg Kilograms Weight
min Minutes Time
s Seconds Time
Wh Watt-hours Battery capacity
mAh Milliampere-Hours Battery capacity
Direct current
Type or a characteristic of
current
8
Symbol Name Designation/Explanation
Main Button Power/Measure/Unit button
UP Arrow Button Mode/Unit button
Down Arrow Button
Mode button besides
relative angle measurement
Full-battery indicator
Indicate the battery is fully
charged
Empty-battery
indicator
Indicate the battery is
exhausted
Distance reference
base indicator
Indicates that the
measurement is taken from
the rear of the tool
Laser indicator
Indicates that laser is turned
on
Single-distance
measure
Indicates enter the single-
distance measurement
mode
Area measure
Indicates enter the area
measurement mode
Real time measure
Indicates enter the real-time
measurement mode
Indirect measure
Indicates enter the Indirect
measurement mode
Level measure
Indicates enter the digital
leveling mode
9
Symbol Name Designation/Explanation
CEC Energy
Efciency Logo
CEC certication logo for
battery charging system
Li-ion RBRC seal
Designates Li-ion battery
recycling program
Read manual symbol Alerts user to read manual
10
GET TO KNOW YOUR LASER TOOL
The tool is a combo tool for highly accurate measuring and leveling.
Measures distances from 1-100 feet with an accuracy of ±1/8
inch.
Measures distances and computes areas.
Real-time distance measuring.
Makes angle measurements with superior accuracy.
Quick indirect measurement of indirect distance and indirect
height.
Easy-to-read numbers and user-friendly interface in backlit
display.
Integrated, rechargeable Lithium battery.
11
Fig. 1
LCD
Screen
Main
Button
Angle Base
Laser-Receiving
Lens
Micro USB Charging Port
Laser-Exit
Aperture
USB Charging
Cable
Distance
Reference
Base
UP Arrow
Button
Down Arrow
Button
PACKING LIST
PART NAME QTY
100ft Laser Distance Measurer & Level 1
USB Charging Cable 1
Soft Bag 1
Instruction Manual 1
12
SPECIFICATIONS
Battery voltage 500mAh 3.7 V Lithium
Laser
λ=635nm, Class II laser,Maximum laser
output < 1mw
Measuring range
(typically)*
Distances 1-100 feet (0.3-30 m)
Angles 0-90°
Measuring accuracy
(typically)*
Distances ±1/8 inch (±3 mm)
Angles ± 0.5°
Smallest unit displayed 1/16 inch (0.001 m)
Automatic switch off
Distances
Laser: 20 seconds
Measuring: 3 minutes
(calculating after the
laser turns off)
Angles Measuring: 6 minutes
Estimated battery life Up to 3000 single measurements
Optimum operating
temperature
+32°F to 104°F (0
o
C to 40
o
C)
Storage temperature -4°F to 170.6°F (-20
o
C to 77
o
C)
*Important: Under unfavorable conditions, such as in bright sunlight
or when measuring poorly reecting or very rough surfaces, the
tool’s measuring range and accuracy will be reduced.
13
OPERATING INSTRUCTIONS
WARNING
To reduce the risk of re, personal injury,
and product damage due to a short
circuit, never immerse your tool or charger in uid or allow
a uid to ow inside it.
Corrosive or conductive uids, such as
seawater, certain industrial chemicals, and bleach or bleach
containing products, etc., can cause a short circuit.
Charge The Tool
NOTE:
The tool is shipped partially charged; charge the battery
before rst use.
Optimum performance can be reached by recharging the tool
for approximately 2.5 hours after use. It is not recommended to
recharge the tool for more than 24 hours after each use.
a. Insert the USB interface of the USB charging cable into the USB
port of the USB wall adapter (not included).
b. Insert the charging plug into charging port of the tool, making sure
that they are properly connected. (FIG. 2)
c. Connect the wall adapter (together with USB charging cable) to
the power outlet. The tool will turn on automatically. The battery
indicator will begin to icker on the LCD display to indicate that
the tool is charging.
14
When charging is complete, the full-battery indicator will appear
on the LCD screen. Remember to remove the USB charging cable
from tool. If the USB charging cable remains connected to the tool,
the tool will turn off approximately after half an hour.
Fig. 2
Charging Plug
Charging PortUSB Interface
Turn The Tool On And Off
Press the Main Button to turn on the tool. Press and hold the Main
Button for 1 second to turn off the tool.
WARNING
The laser will be automatically activated when
the tool is turned on.
DO NOT place the
measuring tool in a position that may cause anyone to stare into the
laser intentionally or unintentionally. Serious eye injury could result.
NOTE:
When the tool is inactive for 3 minutes (after the laser has
turned off) in any mode except the digital leveling mode, it will
automatically turn off to save battery power. When in the digital
leveling mode, the tool will automatically turn off after 6 minutes
of inactivity, which is dened as the deviation (both positive and
negative) angle range not exceeding 1.5°.
15
Change The Measure Mode
Press the UP or Down Arrow Button to scroll through the following
modes:
Single-distance measurement
Area measurement
Real-time measurement
Indirect measurement
Digital leveling
Change the Unit of Measure (Single-Distance, Area,
Real Time, and Indirect Measurement)
Option 1
Main Button
NOTE:
The tool defaults to feet and inches before the rst use.
Press and hold the Main Button to turn on the tool. Continue holding
for more than 2 seconds until the desired unit of measurement
(feet/inch or meters) is displayed on the screen (FIG. 3). When the
desired unit of measurement appears on the screen, release the
Main Button. After releasing the button, the tool turns itself on and
subsequent measurements will be displayed in the selected unit.
MODE
Distance
MODE
Distance
m
Fig. 3
16
Option 2
Press the Main Button to turn on the tool. Press and hold the UP
Arrow Button for 2 seconds until the desired unit of measurement
among the choices listed below is displayed on the screen.
Distance Area
Unit and
precision
0.000 m 0.000 m
2
0’ 00”
1/16
0.000 ft
2
0”
1/16
0.000 ft
2
0.000” 0.000 ft
2
NOTE:
Faulty measurements cannot be excluded when measuring
to different surfaces.
Among the problematic surfaces are:
Transparent surfaces (e.g., glass, water)
Reective surfaces (e.g., polished metal, glass)
Porous surface (e.g., insulation materials)
Structured surfaces (e.g., roughcast, natural stone)
If required, use a laser target plate (not included) on these surfaces.
Furthermore, faulty measurements are also possible when sighting
inclined target surfaces.
Air layers with varying temperatures or indirectly received reections
can affect the measured value.
NOTE:
When error messages occur in the LCD display, press any
button to go back to the initial measurement display.
NOTE:
When entering into the modes involve of distance
measuring, the distance measurement will be taken from the
Distance Reference Base of the tool.
17
Single-Distance Measurement
a. Turn on the tool; the tool will default to the single-distance
measurement mode and the LCD will display “Distance” on the
lower right. The laser will turn on automatically and the laser
indicator will blink. (FIG. 4)
b. Aim the laser at the target to which you want to measure.
Press the Main Button to take a measurement. The resulting
measurement will be displayed on the LCD screen and the laser
will turn off automatically (FIG. 4).
MODE
Distance
MODE
Distance
Fig. 4
18
To take a second measurement:
a. Press the Main Button to turn
on the laser again; the rst
measurement will be displayed
in the upper row of the screen
(FIG. 5).
b. Press the Main Button again
to take a measurement. The
resulting second measurement
will be displayed in the lowest
row of the screen, and the laser will turn off automatically (FIG. 5).
NOTE:
When the laser is inactive for 20 seconds, it will
automatically turn off.
Area Measurement
a. Press UP Arrow Button or Down
Arrow Button to change the
mode to the area measurement.
The LCD will display “Area” on
the lower right (FIG. 6).
b. Press the Main Button to turn
on the laser if it is turned off; the
laser indicator will blink.
c. Position the tool to aim the laser
dot at the target representing the
rst dimension that you want to measure (e.g., length).
d. Press the Main Button to display the measured length in the rst
row of the screen.
e. Position the tool to aim the laser dot at the target representing the
second dimension that you want to measure (e.g., width).
MODE
Distance
Fig. 5
MODE
Area
Fig. 6
19
f. Press the Main Button again. The width will display in the second
row and the area computation will display in the lowest row of the
screen (FIG. 7). The laser will turn off automatically.
g. Press the Main Button again to make a new measurement.
NOTE:
When the laser is inactive for 20 seconds, it will
automatically turn off.
MODE
Area Area
MODE
Fig. 7
Real-Time Measurement
The real-time measurement function can be used for transferring
measurements, e.g., from construction plans. In the real-time
measure mode, the tool can be moved relative to the target and
will continuously update the displayed distance to the target as
the tool is moved. For example, the user can move from a wall to
a predetermined distance, during which time the actual, changing
measurement is displayed continuously.
a. Press UP Arrow Button or Down Arrow Button to change the
mode to the real-time measurement. The LCD will display “Real-
Time” on the lower right (FIG. 8).
b. Press the Main Button to turn on the laser if it is turned off; the
Laser Indicator will blink.
c. Press the Main Button to take the measurement; the beeper is
activated and the tool sounds.
20
d. Move the tool until the required distance value is indicated at the
lower row on the LCD screen (FIG. 8).
NOTE:
Press the Main Button to stop the real-time measurement
during 3 minutes of operation.
Press the Main Button again to make a new measurement.
NOTE:
When the laser is inactive for 20 seconds, it will
automatically turn off
.
MODE MODE
Real Time Real Time
Fig. 8
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86
  • Page 87 87
  • Page 88 88
  • Page 89 89
  • Page 90 90
  • Page 91 91
  • Page 92 92
  • Page 93 93
  • Page 94 94
  • Page 95 95
  • Page 96 96
  • Page 97 97
  • Page 98 98
  • Page 99 99
  • Page 100 100

Skil ME981901 Owner's manual

Category
Distance meters
Type
Owner's manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI