Bradley S19-879EXP2A Installation guide

Category
Sanitary ware
Type
Installation guide

This manual is also suitable for

P.O. Box 309, Menomonee Falls, WI USA 53052-0309
PHONE 800.BRADLEY (800.272.3539) FAX 262.251.5817
bradleycorp.com
Installation
215-1652; ECN 08-502
© 2008 Bradley Corporation
Page 1 of 10 11/19/08
S19-879EXP2A (115V)
S19-879EXP2B (230V)
Class 1, Division 2 Indicator Light
(explosion-proof; includes 115V and
230V versions)
Classe 1, Division 2 Voyant Lumineux
(anti-déflagrant ; inclut les versions
115V et 230V)
Clase 1, División 2 Luz indicadora (a
prueba de explosiones ; incluye las
versiones de 115V y 230V)
Table of Contents
Pre-Installation Information . . . . . . . . . . . . . . . . . . . 2
Indicator Light Components. . . . . . . . . . . . . . . . . . . 3
Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Table des matières
Avant l’installation . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Eléments . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Contenido
Información previa a la instalación . . . . . . . . . . . . . 8
Componentes de la luz indicadora . . . . . . . . . . . . . 9
Instalación . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
S19-879EXP2A
S19-879EXP2B
2
S19-879EXP2A, S19-879EXP2B Installation
11/19/08 Bradley Corporation • 215-1652; ECN 08-502
IMPORTANT
Read this installation manual completely to ensure proper installation, then file it
with the owner or maintenance department. Compliance and conformity to drain
requirements and other local codes and ordinances is the responsibility of the installer.
Separate parts from packaging and make sure all parts are accounted for before
discarding any packaging material. If any parts are missing, do not begin installation
until you obtain the missing parts.
Flush the water supply lines before beginning installation and after installation is
complete. Test the unit for leaks and adequate water flow. Main water supply to the
eyewash should be “ON” at all times. Provisions shall be made to prevent unauthorized
shutoff.
The ANSI Z358.1 standard requires an uninterruptible supply of flushing fluid at a
minimum 30 PSI (0.21 MPa) flowing pressure. Flushing fluid should be tepid per ANSI
Z358.1.
The inspection and testing results of this equipment should be recorded weekly to verify
proper operation. This equipment should be inspected annually to ensure compliance
with ANSI Z358.1.
Workers who may come in contact with potentially hazardous materials should be
trained regarding the placement and proper operation of emergency equipment per ANSI
Z358.1.
For questions regarding the operation or installation of this product, visit www.
bradleycorp.com or call 1-800-BRADLEY.
Product warranties and parts information may also be found under ”Products” on our
web site at www.bradleycorp.com.
Installation
THIS
SIDE
UP
Packing List
P
.
O
.
B
o
x
3
0
9
,
M
e
n
o
m
o
n
e
e
F
a
ll
s
,
W
I 5
3
0
5
1
R
T
E
S
T
T
H
I
S
U
N
I
T
E
A
C
H
W
E
E
K
Test-o
perate v
alv
e(s) ea
c
h w
eek an
d sign
belo
w
.
R
eport an
y m
alfunction
s immed
iat
el
y
.
Ventil(e) w
öc
hen
tlic
h im
Testbe
trie
b
prüfen,
b
est
ätigt
durch U
ntersc
hrift. J
eglic
he S
törun
g s
of
or
t m
elden.
Date
Datum
Date
Signed
Unterschrift
Signe
Date
Date
Date
Signed
Signed
Signed
D
I
E
S
E
S
G
E
R
Ä
T
1
S
T
W
Ö
C
H
E
N
T
L
IC
H
Z
U
P
R
Ü
F
E
N
.
E
S
S
A
I
H
E
B
D
O
M
A
D
A
I
R
E
Test le
fonctio
nnem
ent d
es v
alv
es
chaque sem
aine et
sign
e en b
as. S
'il y
à quelqu
e c
ho
se qui n
e v
a p
as fait
un
rappor
t im
m
édiatem
ent.
P.O. BOX 309, MENOMONEE FALLS, WI 53052-0309 USA
TEL: 1-800-BRADLEY FAX: (262-251-5817)
http://www.bradleycorp.com
114-051
3
Installation S19-879EXP2A, S19-879EXP2B
Bradley Corporation • 215-1652; ECN 08-502 11/19/08
Assembly of Components
Explosion-Proof Indicator Light
S19-879EXP2A (115V)
(Rated Class 1, Division 2, Groups C and D)
Nipple
269-1582
Black
White
Dual Indicator
Lamps with Box
269-1929
Black
Green
Green
Red
Red
White
Nipple
269-1582
Dual Indicator
Lamps with Box
269-1930
Explosion-Proof Indicator Light
S19-879EXP2B (230V)
(Rated Class 1, Division 2, Groups C and D)
4
S19-879EXP2A, S19-879EXP2B Installation
11/19/08 Bradley Corporation • 215-1652; ECN 08-502
Installation
Supplies Required:
• Pipe sealant
Black, white and green 14 AWG wire to connect indicator light to electric power supply
• Wire nuts
Step 1: Mount indicator light to unit
1. Choose a location for mounting the indicator light. The indicator light may be mounted directly to the unit junction box
at one of the locations shown below.
2. Connect the indicator light to the junction box following the wiring diagram.
Unit Junction
Box
Heat Trace
Drench
Shower
Recommended mounting
locations for S19-879EXP2A
and S19-879EXP2B
Indicator Lights
Green
White
Black
Power
Indicator
Light
Ground Screw-in
Junction Box
Heat Trace
Cable
THERMOSTAT
INDICATOR LIGHT WIRING DIAGRAM
White
Blk
Red
G
A
Amber Lamp = Heater ON
Green Lamp = Power TO UNIT
Green
6
S19-879EXP2A, S19-879EXP2B Installation
11/19/08 Bradley Corporation • 215-1652; ECN 08-502
Assembage des composantes
Voyant Lumineux Antidéflagrant
S19-879EXP2A (115V)
(Classe 1, Division 2, Groupes C and D)
Raccord
269-1582
Noir
Blanc
Boîte de Voyant
Lumineux
269-1929
Noir
Vert
Vert
Rouge
Rouge
Blanc
Raccord
269-1582
Boîte de Voyant
Lumineux
269-1930
Voyant Lumineux Antidéflagrant
S19-879EXP2B (230V)
(Classe 1, Division 2, Groupes C and D)
8
S19-879EXP2A, S19-879EXP2B Installation
11/19/08 Bradley Corporation • 215-1652; ECN 08-502
IMPORTANTE
Lea en su totalidad este manual de instalación para garantizar una instalación adecuada.
Una vez que termine la instalación, entregue este manual al propietario o al Departamento
de Mantenimiento. Es responsabilidad de quien instale el equipo cumplir con los códigos
para desagüe y otra códigos y ordenanzas locales.
Separar todas las piezas del material de embalaje y asegurarse que todas las piezas
estén incluídas antes de desechar cualquier material de embalaje. Si faltase alguna pieza,
no intentar instalar la unidad combinada Bradley hasta obtener las piezas faltantes.
Aclarar el conducto del suministro de agua antes y después de la instalación. Verificar
que no haya fugas y que el flujo de agua sea adecuado. El suministro principal de agua a
la unidad debe estar siempre en posición “ON” (abierto). Se deben tomar medidas a fin de
evitar el corte no autorizado del suministro.
La norma ANSI Z358.1 exige un suministro ininterrumpido del líquido de enjuague a
una presión mínima de 30 psi (0.21 MPa). El líquido de limpieza debe estar tibio en
conformidad con la norma ANSI Z358.1.
Este equipo se debe inspeccionar, probar y anotar semanalmente para mantener un
funcionamiento adecuado
. Se debe revisar este equipo anualmente para asegurarse de
que cumpla con la norma ANSI Z358.1.
Los trabajadores que puedan tener contacto con materiales potencialmente peligrosos
deben recibir capacitación sobre la ubicación y operación adecuada de los equipos de
emergencia en conformidad con la norma ANSI Z358.1.
Para consultas sobre la operación o instalación de este producto, visite www.bradleycorp.
com o llame al 1-800-BRADLEY.
Las garantías del producto se pueden encontrar e n “Información del producto” o en
nuestro sitio Web, www.bradleycorp.com.
Installation
THIS
SIDE
UP
Packing List
P
.
O
.
Bo
x
3
0
9
, M
e
n
o
m
o
n
e
e
F
a
ll
s
,
W
I 5
3
0
5
1
R
T
E
S
T
T
H
IS
U
N
I
T
E
A
C
H
W
E
E
K
T
est-o
perate v
alv
e(s) eac
h w
eek an
d sign
belo
w
.
R
epor
t an
y m
alfun
ctio
ns
im
me
d
iatel
y.
Ventil(e) w
ö
c
hen
tlic
h
im
Te
s
tbetrieb
prüfen
,
bestätigt
durch Unterschrift. Jeglic
he S
törun
g sof
or
t m
elden
.
Date
Datum
Date
Signed
Unterschrift
Signe
Date
Date
Date
Signed
Signed
Signed
D
I
E
S
E
S
G
E
R
Ä
T
1
S
T
W
Ö
C
H
E
N
T
L
I
C
H
Z
U
P
R
Ü
F
E
N
.
E
S
S
A
I
H
E
B
D
O
M
A
D
A
I
R
E
Test le fonctio
nnem
ent d
es v
alves
cha
qu
e semaine
et
sign
e en bas. S
'il y à quelqu
e c
hose qu
i ne v
a pas fait
un
rappo
r
t im
m
édiatem
en
t.
P.O. BOX 309, MENOMONEE FALLS, WI 53052-0309 USA
TEL: 1-800-BRADLEY FAX: (262-251-5817)
http://www.bradleycorp.com
114-051
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10

Bradley S19-879EXP2A Installation guide

Category
Sanitary ware
Type
Installation guide
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI