ATEN PE4104G User manual

Category
Power distribution units (PDUs)
Type
User manual
IP Control Box
PE4104G User Manual
www.aten.com
PE4104G User Manual
ii
EMC Information
FEDERAL COMMUNICATIONS COMMISSION INTERFERENCE
STATEMENT. This equipment has been tested and found to comply with the
limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These
limits are designed to provide reasonable protection against harmful
interference when the equipment is operated in a commercial environment.
This equipment generates, uses, and can radiate radio frequency energy and, if
not installed and used in accordance with the instruction manual, may cause
harmful interference to radio communications. Operation of this equipment in
a residential area is likely to cause harmful interference in which case the user
will be required to correct the interference at his own expense.
FCC Caution: Any changes or modifications not expressly approved by the
party responsible for compliance could void the user's authority to operate this
equipment.
This device complies with Part 15 of the Fcc Rules. Operation is subject to the
following two conditions:
(1) this device may not cause harmful interference, and
(2) this device must accept any interference received, including interference
that may cause undesired operation.
Warning: Operation of this equipment in a residential environment could
cause radio interference.
Achtung: Der Gebrauch dieses Geräts in Wohnumgebung kann
Funkstörungen verursachen.
KCC Statement
RoHS
This product is RoHS compliant.
© Copyright 2020 ATEN® International Co., Ltd.
Manual Date: 2020-12-23
ATEN and the ATEN logo are registered trademarks of ATEN International Co., Ltd. All rights reserved.
All other brand names and trademarks are the registered property of their respective owners.
PE4104G User Manual
iii
User Information
Online Registration
Be sure to register your product at our online support center:
Telephone Support
For telephone support, call this number:
User Notice
All information, documentation, and specifications contained in this manual are subject
to change without prior notification by the manufacturer. The manufacturer makes no
representations or warranties, either expressed or implied, with respect to the contents
hereof and specifically disclaims any warranties as to merchantability or fitness for any
particular purpose. Any of the manufacturer's software described in this manual is sold
or licensed as is. Should the programs prove defective following their purchase, the
buyer (and not the manufacturer, its distributor, or its dealer), assumes the entire cost of
all necessary servicing, repair and any incidental or consequential damages resulting
from any defect in the software.
The manufacturer of this system is not responsible for any radio and/or TV interference
caused by unauthorized modifications to this device. It is the responsibility of the user
to correct such interference.
The manufacturer is not responsible for any damage incurred in the operation of this
system if the correct operational voltage setting was not selected prior to operation.
PLEASE VERIFY THAT THE VOLTAGE SETTING IS CORRECT BEFORE USE.
If any bodily injury or property damage with respect to operation of the product results
from users not having installed the product in accordance with the instructions provided
in the product’s user manual, or the product is used in an environment with a current
load over the designed specifications of the product, ATEN is not liable for any loss or
damage.
International http://support.aten.com
International 886-2-8692-6959
China 86-400-810-0-810
Japan 81-3-5615-5811
Korea 82-2-467-6789
North America 1-888-999-ATEN ext 4988
1-949-428-1111
PE4104G User Manual
iv
Package Contents
1 PE4104G IP Control Box
1 Standard Rack Mount Kit
1 Power Cord
4Footpads
1 User Instructions*
Check to make sure that all of the components are present and in good order.
If anything is missing, or was damaged in shipping, contact your dealer.
Read this manual thoroughly and follow the installation and operation
procedures carefully to prevent any damage to the unit or to any other devices
connecting to the unit.
* Features may have been added to the unit since this manual was published.
Please visit our website to download the most up-to-date version.
PE4104G User Manual
v
Contents
EMC Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ii
User Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .iii
Online Registration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .iii
Telephone Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .iii
User Notice . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .iii
Package Contents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . iv
About This Manual . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .viii
Conventions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ix
Product Information. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ix
Chapter 1.
Introduction
Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Optional Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
Sensors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Sensor Management . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Cable Holders . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
PE4104G Front View. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
PE4104G Rear View . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
Chapter 2.
Hardware Setup
Rack Mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Desktop Mount . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Using the Rack Mount Ears. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Securing the Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Chapter 3.
Basic Operation and
First Time Setup
Operation Methods . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Browser . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
eco DC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11
SNMP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
First Time Setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Network Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Changing the Administrator Login . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Moving On. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Chapter 4.
Browser Operation
Logging In . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
The eco PDU Main Page . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Page Components. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Energy . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
PE4104G User Manual
vi
Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
PDU Status . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Sensor Status . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
Outlet Status . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Power On Time Schedule Settings . . . . . . . . . . . . . . . . . . . . . . . . 21
Buzzer Setting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Outlet Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
User . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
Administrator Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
SNMPv3 Account Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
SNMPv1/v2c Community . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
Telnet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
SSH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
User Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
Log . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
System Log . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
Notification Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
Setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
Device Configuration. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
Service Ports . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
IPv4 Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
Event Notification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
Date/Time . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
Finishing Up . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
Security . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
Working Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
TLS Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
IPInstaller Setting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
Session Timeout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
Account Policy. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
IP Filter / Mac Filter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
Authentication & Authorization . . . . . . . . . . . . . . . . . . . . . . . . . . . 44
Private Certificate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
EcoTCP. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
PDU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47
Upgrade Main Firmware . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47
Firmware File. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47
Backup/Restore . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
Station List. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
Backup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
Restore . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50
Chapter 5.
Telnet Commands
Remote Terminal Operations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51
PE4104G User Manual
vii
Telnet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51
Setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51
Logging In . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51
Session Timeout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52
Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .53
Verification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53
Read Power Outlet Status . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .54
Switch Outlet Status . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55
Read Power Value . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57
Read Environmental Value . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59
Close Telnet Session . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60
Reboot PDU Device . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61
Reset All PDU Config to Default Value . . . . . . . . . . . . . . . . . . . . . . . . 61
Appendix
Safety Instructions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .63
General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63
Rack Mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65
Technical Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66
International . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66
North America . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .66
IP Address Determination . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .67
Method 1: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67
Method 2:. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68
Method 3:. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68
Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .69
PE4104G. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69
Administrator Login Failure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71
Limited Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72
PE4104G User Manual
viii
About This Manual
This User Manual is provided to help you get the most from the PE4104G unit/
system. It covers all aspects of installation, configuration and operation. An
overview of the information in the manual is provided below.
Chapter 1, Introduction, introduces you to the unit/system. It presents
purpose, features and benefits are presented, and its front and back panel
components are described.
Chapter 2, Hardware Setup, provides step-by-step instructions for setting
up your installation, and explains some basic operation procedures.
Chapter 3, Basic Operation and First Time Setup, explains the
procedures that the Administrator employs to set up the PE4104G network
environment, and change the default username and password.
Chapter 4, Browser Operation, describes how to log in to the PE4104G
with an Internet browser, and explains the layout and components of the
PE4104G’s user interface.
Chapter 5, Telnet Commands, describes how to connect to and access the
PE4104G’s using Telnet.
An Appendix, at the end of the manual provides technical and
troubleshooting information.
PE4104G User Manual
ix
Conventions
This manual uses the following conventions:
Product Information
For information about all ATEN products and how they can help you connect
without limits, visit ATEN on the Web or contact an ATEN Authorized
Reseller. Visit ATEN on the Web for a list of locations and telephone numbers:
Monospaced Indicates text that you should key in.
[ ] Indicates keys you should press. For example, [Enter] means
to press the Enter key. If keys need to be chorded, they appear
together in the same bracket with a plus sign between them:
[Ctrl+Alt].
1. Numbered lists represent procedures with sequential steps.
Bullet lists provide information, but do not involve sequential
steps.
Indicates selecting the option (on a menu or dialog box, for
example), that comes next. For example, Start
Run means
to open the Start menu, and then select Run.
Indicates critical information.
International http://www.aten.com
North America http://www.aten-usa.com
PE4104G User Manual
x
This Page Intentionally Left Blank
1
Chapter 1
Introduction
Overview
Engineered to be an intelligent power distribution solution, the PE4104G IP
Control Box ships with 4 power outlets in an IEC socket configuration. It
provides secure, centralized, intelligent, and remote power management of
data center IT equipment to minimize the operating cost.
The PE4104G offers remote power control combined with real-time power
measurement. It allows you to control devices attached to the PDU at the PDU
device level from practically any location via a TCP/IP connection. The power
sequence design eliminates the risks for a power inrush to guarantee reliable
operation and protects the overall system health. With the support for eco DC
software, it provides an easy method for managing multiple devices, offering
an intuitive and user-friendly Graphical User Interface that allows you to
configure a PDU device, reboot the device in case of any equipment lock-up
occurs, and power status of the equipment connected to it. The administrators
are allowed to switch on/off or set a delay time for each power outlet or
individual power outlets group whenever, wherever.
The PE4104G boasts a slim, compact form factor and supports desk mount as
well as rack mount, ensuring easy installation in confined spaces. It is a smart
power control box tailored for hospitality or retail applications, such as digital
signages and video walls, for edge computing devices, including routers,
servers and cameras, or for any data center environments where there is no
need to keep the servers powered on at all times.
PE4104G User Manual
2
Features
Power Distribution
Space saving slim form factor
IEC power outlet
Separates power for the unit’s own power and its power outlets – user
interface is still accessible even when an overload condition trips the
device’s circuit breaker
Remote Access
Remote power control via TCP/IP and a built in 10/100 Ethernet port
Network Interfaces: TCP/IP, UDP, HTTP, HTTPS, SSL, SMTP, ARP,
NTP, DNS, SNMP V1&V2&V3, auto sense, Ping, Telnet, Modbus (Over
TCP IP)
Works with web-based eco DC software
Operation
Local and Remote power outlet control (On, Off, Power Cycle) by
individual outlets
Power-on sequencing – users can set the power on sequence and delay
time for each port to allow equipment to be turned on in a proper order
Easy setup and operation via a browser-based user interface
Security
Two-level password security
Strong security features include password protection and advanced
encryption technologies – TLS1.2
Remote authentication support: RADIUS
Chapter 1. Introduction
3
Requirements
Browsers accessing the PE4104G unit must support 2048 and 4096 bit
encryption.
For cold booting of attached computers, the computer’s BIOS must
support wake on LAN or System after AC Back.
For Safe Shutdown:
The computer must be running Windows (Windows 2000 or higher) or
Linux.
The Safe Shutdown program (available by download from our
website), must be installed and running on the computer.
PE4104G User Manual
4
Optional Accessories
Sensors
Sensors are optional accessories. You can use the PE4104G unit without
sensors. However, if you want to have complete energy management of an
instrumented data center with the use of the PE4104G, you would need to use
eco DC software and install sensor to generate a complete energy-efficient data
and chart. Higher sensor installation density is helpful to generate more
accurate data. A sensor-enabled installation is required to generate a more
complete energy-efficient data and chart. Higher sensor installation density is
helpful to generate more accurate data. Available sensors are show in the table,
below:
Sensor Management
Sensors can be managed via the PE4104G’s built-in graphical user interface
(GUI) or with the eco DC software that can be downloaded from the ATEN
website.
Cable Holders
Cable holders are optional accessories. For added safety, use ATEN Lok-U-
Plug cable holders to secure the cables from your attached devices in place on
the eco PDU unit. Use only the ATEN Lok-U-Plug cable holders that have
been specifically designed to work with the eco PDU. Using any other kind of
cable securing device could be highly dangerous. For more information, see
Securing the Cable, page 10.
Sensor Part Number
Temperature EA1140
Temperature / Humidity EA1240
Differential Pressure / Temperature EA1340
Part Number Description
2X-EA07 Lok-U-Plug Cable Holder (10 pcs)
2X-EA08 Lok-U-Plug Installation Tool (4 pcs)
2X-EA10 C14 EZ-Lok Plug Connector (10 pcs)
2X-EA13 C14 Smart-Lok Plug Connector (10 pcs)
Chapter 1. Introduction
5
Components
PE4104G Front View
No. Component Description
1 LAN Port The Cat 5e cable that connects the unit to the Internet
plugs in here.
2 Reset Button
(recessed)
Press and release to reboot the unit. This Reset Button
is recessed and must be pushed with a thin object, such
as the end of a paper clip, or a ballpoint pen.
3 Sensor Port & LED The external sensor plug into this RJ-11 port, and the
sensor LED lights orange when a sensor is connected to
the sensor port.
4 Door Sensor Dry-
Contact Port
The external door sensor plug into this Door Sensor Dry-
Contact port.
5 Power Control Buttons
& LED
Each Power Control Button (1 to 4), controls the power
status of its corresponding AC output port as follow:
Pressing and holding the button in for more than 3
seconds switches the power to its corresponding
port on of off.
The LEDs light green to indicate that there is electricity
going to its corresponding outlet.
6 Device Power LED The Device Power LED lights orange to indicate the unit
is powered up and ready to operate.
1 2 543 6
PE4104G User Manual
6
PE4104G Rear View
No. Component Description
1 Grounding Terminal Connects to a suitable grounding object.
2 Power Outlet Sockets Electrical appliances plug in here.
3 Circuit Breaker Protects the PDU from damage caused by excess
current from an overload or short circuit.
4 Power Inlet Socket The power cord of the package content plugs in here.
21 3 4
7
Chapter 2
Hardware Setup
Rack Mounting
The PE4104G can be mounted vertically on the outside of the rack and a few
options are available.
Desktop Mount
If you wish to keep your unit on a desktop, attach the footpads (in the package
content) and place the unit on any appropriate level surface that can safely
support its weight plug the weight of its attached cables.
Using the Rack Mount Ears
1. Decide where you would rack mount the unit and choose the place you
would attach the rack mount ear (Position 1, 2, 3, or 4). As an example, we
will choose to attach the mounting ears shown below (position 3).
Important safety information regarding the placement of this device is
provided on page 63. Please review it before proceeding.
12
34
Unit
Front
Rear
Rack Mount Ears Rack Mount Ears
Rack Mount Ears Rack Mount Ears
PE4104G User Manual
8
2. Align and stabilize the mounting ear using M3 Phillips Hex Screws.
3. Align the unit and the mounting ear to the rack and stabilize the unit using
rack screws. Let the buttons stabilize in the button holes and the mounting
is complete.
Chapter 2. Hardware Setup
9
Installation
To set up your PE4104G installation, refer to the numbered steps in the
installation diagram below (the numbers in the diagram correspond to the
numbered steps), and do the following:
1. Ground the PE4104G by connecting one end of a grounding wire to the
Grounding Terminal and the other end to a suitable grounded object.
Note: Do not omit this step. Proper grounding helps to prevent damage to
the unit from power surges or static electricity.
2. For each device you want to connect, connect its power cable to any
available outlet on the unit. Optionally, use ATEN Lok-U-Plug cable
holders to secure them. See Securing the Cable, page 10.
3. Connect an internet-enabled LAN cable into the unit’s LAN Port.
4. (Optional) If you are to use an environmental sensor in your installation,
connect it to the RJ-11 Sensor Port located on the unit’s front panel.
5. (Optional) If you are to use a door sensor in your installation, connect it to
the Door Sensor Dry-Contact Port located on the unit’s front panel.
6. Use the provided Power Cord to connect the unit’s Power Inlet Socket to
an AC power source.
7. Once you have finished these installation steps, you can turn on the
connected devices.
1
6
Rear
2
3 4
Front
5
PE4104G User Manual
10
Securing the Cable
For added safety, use ATEN Lok-U-Plug cable holders to secure the cables
from your attached devices in place on the unit. Secure the cable holders using
the specially designed holes around the individual power outlets, as shown
below:
Note: Lok-U-Plug Cable Holders and their Installation Tools are optional and
sold separately. See Cable Holders, page 4
Note:
Lok-U-Plug Cable Holders and their Installation Tools are optional and
sold separately. See Cable Holders, page 4.
Use only the ATEN Lok-U-Plug cable holders that have been specifically
designed to work with the eco PDU. Using any other kind of cable
securing device could be highly dangerous.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82

ATEN PE4104G User manual

Category
Power distribution units (PDUs)
Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI