Dell UCS-51 Owner's manual

Category
RAID controllers
Type
Owner's manual

This manual is also suitable for

www.dell.com | support.dell.com
Template Last Updated - 7/01/2005
Dellâ„¢ Serial-Attached SCSI 6/iR
Integrated and Adapter
User’s Guide
Model UCS-61
book.book Page 1 Monday, September 15, 2008 2:47 PM
book.book Page 2 Monday, September 15, 2008 2:47 PM
www.dell.com | support.dell.com
Dellâ„¢ Serial-Attached SCSI 6/iR
Integrated and Adapter
User’s Guide
Model UCS-61
book.book Page 1 Monday, September 15, 2008 2:47 PM
Notes, Notices, and Cautions
NOTE: A NOTE indicates important information that helps you make better use of
your computer.
NOTICE: A NOTICE indicates either potential damage to hardware or loss of data
and tells you how to avoid the problem.
CAUTION: A CAUTION indicates a potential for property damage, personal injury,
or death.
________________________________________
Information in this document is subject to change without notice.
© 2007-2008 Dell Inc. All rights reserved.
Reproduction of these materials in any manner whatsoever without the written permission of Dell Inc.
is strictly forbidden.
Trademarks used in this text: Dell, the DELL logo, Dell Precision, PowerEdge, and OpenManage are
trademarks of Dell Inc.; Intel is a registered trademark of Intel Corporation; Microsoft, Windows,
Windows Server, and Windows Vista are either trademarks or registered trademarks of Microsoft
Corporation in the United States and/or other countries; Novell, NetWare, and SUSE are registered
trademarks of Novell, Inc. in the United States and other countries; Red Hat Linux and Red Hat
Enterprise Linux are registered trademarks of Red Hat, Inc.; LSI Logic, Fusion-MPT, Integrated
Mirroring, and Integrated Striping are trademarks or registered trademarks of LSI Logic Corporation;
DR-DOS is a registered trademark of DRDOS, Inc.
Other trademarks and trade names may be used in this document to refer to either the entities claiming
the marks and names or their products. Dell Inc. disclaims any proprietary interest in trademarks and
trade names other than its own.
Model UCS-61
July 2008 P/N JM360 Rev. A01
book.book Page 2 Monday, September 15, 2008 2:47 PM
Contents 3
Contents
1 CAUTION: Safety Instructions. . . . . . . . . . 9
SAFETY: General . . . . . . . . . . . . . . . . . . . . . . 9
SAFETY: When Working Inside Your System
. . . . . . . 9
SAFETY: Protecting Against
Electrostatic Discharge
. . . . . . . . . . . . . . . . . 10
2Overview . . . . . . . . . . . . . . . . . . . . . . . . . 11
About RAID. . . . . . . . . . . . . . . . . . . . . . . . 12
RAID Levels
. . . . . . . . . . . . . . . . . . . . . 12
RAID Terminology
. . . . . . . . . . . . . . . . . . . . 12
Integrated Striping
. . . . . . . . . . . . . . . . . 12
Integrated Mirroring
. . . . . . . . . . . . . . . . 13
3 SAS 6/iR Features . . . . . . . . . . . . . . . . . . 15
4 Hardware Installation
. . . . . . . . . . . . . . . 19
Installing the SAS 6/iR Adapter . . . . . . . . . . . . . 19
book.book Page 3 Monday, September 15, 2008 2:47 PM
4 Contents
5 Driver Installation . . . . . . . . . . . . . . . . . 23
Installing the Windows Driver. . . . . . . . . . . . . . 24
Creating the Driver Media
. . . . . . . . . . . . . 24
Pre-Installation Requirements
. . . . . . . . . . . 24
Installing the Driver During a Windows
Server 2003 or Windows XP
Operating System Installation
. . . . . . . . . . . . 25
Installing the Driver During a Windows
Server 2008 or Windows Vista Installation
. . . . . 26
Installing a Windows Server 2003,
Windows Server 2008, Windows Vista,
or Windows XP Driver for
a New RAID Controller
. . . . . . . . . . . . . . . 27
Updating an Existing Windows
Server 2003, Windows Server 2008,
Windows XP, or Windows Vista Driver
. . . . . . . 28
Installing Linux Driver
. . . . . . . . . . . . . . . . . . 29
Installing Red Hat Enterprise Linux
Operating Systems using the
Driver Update Diskette
. . . . . . . . . . . . . . . 30
Red Hat Enterprise Linux 5 Installation
and Disk Enumeration
. . . . . . . . . . . . . . . . 31
Installing SUSE Linux Enterprise Server
Using the Driver Update Diskette
. . . . . . . . . . 31
SUSE Linux Enterprise Server 10
Installation and Disk Enumeration
. . . . . . . . . 32
Installing the RPM Package
With DKMS Support
. . . . . . . . . . . . . . . . 33
book.book Page 4 Monday, September 15, 2008 2:47 PM
Contents 5
6 SAS 6/iR BIOS . . . . . . . . . . . . . . . . . . . . . 35
POST Messages . . . . . . . . . . . . . . . . . . . . . 35
BIOS Fault Code Messages
. . . . . . . . . . . . 35
Configuration Utility
. . . . . . . . . . . . . . . . . . . 36
Starting the Configuration Utility
. . . . . . . . . . 36
Functions Performed
. . . . . . . . . . . . . . . . 36
Navigating the Configuration Utility
. . . . . . . . 37
Integrated RAID Configuration and
Management Screens
. . . . . . . . . . . . . . . . . . 37
Select New Array Type
. . . . . . . . . . . . . . . 38
Create New Array
. . . . . . . . . . . . . . . . . 38
View Array
. . . . . . . . . . . . . . . . . . . . . 41
Manage Array
. . . . . . . . . . . . . . . . . . . 41
Exit Screen
. . . . . . . . . . . . . . . . . . . . . 42
Performing Configuration Tasks
. . . . . . . . . . . . . 42
Creating an Integrated
Striping Virtual Disk
. . . . . . . . . . . . . . . . . 42
Creating a Integrated
Mirroring Virtual Disk
. . . . . . . . . . . . . . . . 43
Viewing Virtual Disk Properties
. . . . . . . . . . 44
Synchronizing a Virtual Disk
. . . . . . . . . . . . 45
Activating a Virtual Disk
. . . . . . . . . . . . . . 45
Migrating and Activating a Virtual Disk
. . . . . . 45
Deleting a Virtual Disk
. . . . . . . . . . . . . . . 46
Hot Spare Failover
. . . . . . . . . . . . . . . . . 46
Replacing and Rebuilding
a Degraded Virtual Disk
. . . . . . . . . . . . . . 46
book.book Page 5 Monday, September 15, 2008 2:47 PM
6 Contents
7 Troubleshooting . . . . . . . . . . . . . . . . . . . 49
BIOS Boot Order . . . . . . . . . . . . . . . . . . . . . 49
General Problems
. . . . . . . . . . . . . . . . . . . . 49
Physical Disk Related Issues
. . . . . . . . . . . . . . 50
Configuration Utility Error Messages
. . . . . . . . . . 51
BIOS Error Messages
. . . . . . . . . . . . . . . . . . 52
A Updating the Firmware . . . . . . . . . . . . . 55
Firmware Update Utility . . . . . . . . . . . . . . . . . 55
B Getting Help . . . . . . . . . . . . . . . . . . . . . . 57
Obtaining Assistance . . . . . . . . . . . . . . . . . . 57
Technical Support and Customer Service
. . . . . 58
Online Services
. . . . . . . . . . . . . . . . . . . 58
Automated Order-Status Service
. . . . . . . . . . 59
Dell Enterprise Training
. . . . . . . . . . . . . . . . . 59
Problems With Your Order
. . . . . . . . . . . . . . . . 59
Product Information
. . . . . . . . . . . . . . . . . . . 59
Returning Items for Warranty Repair or Credit
. . . . . 60
Before You Call
. . . . . . . . . . . . . . . . . . . . . . 60
book.book Page 6 Monday, September 15, 2008 2:47 PM
Contents 7
C Regulatory Notices . . . . . . . . . . . . . . . . . 61
D Corporate Contact Details
(Taiwan Only)
. . . . . . . . . . . . . . . . . . . . . 63
Glossary
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65
Index
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73
book.book Page 7 Monday, September 15, 2008 2:47 PM
8 Contents
book.book Page 8 Monday, September 15, 2008 2:47 PM
Safety Instructions 9
CAUTION: Safety Instructions
Use the following safety guidelines to help ensure your own personal safety and to help protect
your system and working environment from potential damage.
NOTE: See the caution and safety statements in your Dellâ„¢ PowerEdgeâ„¢ system
or Dell Precisionâ„¢ workstation.
SAFETY: General
• Observe and follow service markings. Do not service any product except as explained in
your user documentation. Opening or removing covers that are marked with the triangular
symbol with a lightning bolt may expose you to electrical shock. Components inside these
compartments should be serviced only by a trained service technician.
• If any of the following conditions occur, unplug the product from the electrical outlet and
replace the part or contact your trained service provider:
– The power cable, extension cable, or plug is damaged.
– An object has fallen into the product.
– The product has been exposed to water.
– The product has been dropped or damaged.
– The product does not operate correctly when you follow the operating instructions.
• Use the product only with approved equipment.
• Operate the product only from the type of external power source indicated on the
electrical ratings label. If you are not sure of the type of power source required, consult
your service provider or local power company.
• Handle batteries carefully. Do not disassemble, crush, puncture, short external contacts,
dispose of in fire or water, or expose batteries to temperatures higher than
60 degrees Celsius (140 degrees Fahrenheit). Do not attempt to open or service batteries;
replace batteries only with batteries designated for the product.
SAFETY: When Working Inside Your System
Before you remove the system covers, perform the following steps in the sequence indicated.
CAUTION: Except if expressly otherwise instructed in Dell documentation, only trained
service technicians are authorized to remove the system cover and access any of the
components inside the system.
NOTICE: To help avoid possible damage to the system board, wait for 5 seconds after
turning off the system before removing a component from the system board or disconnecting
a peripheral device.
book.book Page 9 Monday, September 15, 2008 2:47 PM
10 Safety Instructions
1
Turn off the system and any devices.
2
Ground yourself by touching
an unpainted metal surface on the chassis before touching
anything inside the system.
3
While you work, periodically touch an unpainted metal surface on the chassis to dissipate any
static electricity that might harm the internal components.
4
Disconnect
your system and devices from their power sources. To reduce the potential of
personal injury or shock, disconnect any telecommunication lines from the system.
In addition, take note of these safety guidelines when appropriate:
• When you disconnect a cable, pull on its connector or on its strain-relief loop, not on the
cable itself. Some cables have a connector with locking tabs; if you are disconnecting this
type of cable, press in on the locking tabs before disconnecting the cable. As you pull the
connectors apart, keep them evenly aligned to avoid bending any connector pins. Also, before
you connect a cable, make sure that both connectors are correctly oriented and aligned.
• Handle components and cards with care. Do not touch the components or contacts on a
card. Hold a card by its edges or by its metal mounting bracket. Hold a component such as
a microprocessor chip by its edges, not by its pins.
SAFETY: Protecting Against Electrostatic
Discharge
Electrostatic discharge (ESD) events can harm electronic components inside your computer.
Under certain conditions, ESD may build up on your body or an object, such as a peripheral, and
then discharge into another object, such as your computer. To prevent ESD damage, you should
discharge static electricity from your body before you interact with any of your computer’s internal
electronic components, such as a memory module. You can protect against ESD by touching a
metal grounded object (such as an unpainted metal surface on your computer’s I/O panel) before
you interact with anything electronic. When connecting a peripheral (including handheld digital
assistants) to your computer, you should always ground both yourself and the peripheral before
connecting it to the computer. In addition, as you work inside the computer, periodically touch an
I/O connector to remove any static charge your body may have accumulated.
You can also take the following steps to prevent damage from electrostatic discharge:
• When unpacking a static-sensitive component from its shipping carton, do not remove the
component from the antistatic packing material until you are ready to install the
component. Just before unwrapping the antistatic package, be sure to discharge static
electricity from your body.
• When transporting a sensitive component, first place it in an antistatic container or
packaging.
• Handle all electrostatic sensitive components in a static-safe area. If possible, use antistatic
floor pads and work bench pads.
book.book Page 10 Monday, September 15, 2008 2:47 PM
Overview 11
Overview
The Dell™ Serial-Attached SCSI (SAS) 6/iR controller is Dell’s next generation
controller with integrated redundant array of independent disks (RAID)
capabilities. SAS technology is not backward compatible with the previous
generation of SCSI devices. All SAS 6/iR controllers are half-length, standard-
height PCI-E cards, except for the SAS 6/iR Integrated controller on the blade
servers and on the Precision workstations. The SAS 6/iR controllers are
supported on platforms with PCI-E x4, x8 and x16 connectors.
Figure 2-1. SAS 6/iR Adapter Hardware Architecture
1 SAS x4 internal connector 2 PCI-E connector
1
2
book.book Page 11 Monday, September 15, 2008 2:47 PM
12 Overview
About RAID
RAID is a group of multiple independent physical disks that provide high
performance or better data availability by increasing the number of drives
used for saving and accessing data. A RAID disk subsystem improves
I/O performance and data availability. The physical disk group appears to the
host system as a single storage unit. Data throughput improves because
multiple disks can be accessed simultaneously. RAID systems also improve
data storage availability and fault tolerance.
RAID Levels
RAID 0 uses disk striping to provide high data throughput, especially for large
files in an environment that requires no data redundancy.
Integrated Mirroring or RAID 1 uses disk mirroring so that data written to
one physical disk is simultaneously written to another physical disk. This is
good for small databases or other applications that require small capacity, but
complete data redundancy.
NOTICE: Lost data on an Integrated Striping virtual disk cannot be recovered in the
event of a physical disk failure.
RAID Terminology
Integrated Striping
Integrated Striping (RAID 0) allows you to write data across multiple physical
disks instead of just one physical disk. Integrated Striping involves partitioning
each physical disk storage space into 64 KB stripes. These stripes are
interleaved in a repeated sequential manner. The part of the stripe on a single
physical disk is called a stripe element.
For example, in a four-disk system using only Integrated Striping, segment 1 is
written to disk 1, segment 2 is written to disk 2, and so on. Integrated Striping
enhances performance because multiple physical disks are accessed
simultaneously, but Integrated Striping does not provide data redundancy.
Figure 2-2 shows an example of Integrated Striping.
book.book Page 12 Monday, September 15, 2008 2:47 PM
Overview 13
Figure 2-2. Example of Integrated Striping (RAID 0)
Integrated Mirroring
With Integrated Mirroring (RAID 1), data written to one disk is
simultaneously written to another disk. If one disk fails, the contents of the
other disk can be used to run the system and rebuild the failed physical disk.
The primary advantage of Integrated Mirroring is that it provides 100 percent
data redundancy. Because the contents of the disk are completely written to a
second disk, the system can sustain the failure of one disk. Both disks contain
the same data at all times. Either physical disk can act as the operational
physical disk.
NOTE: Mirrored physical disks improve read performance by read load balance.
Figure 2-3. Example of Integrated Mirroring (RAID 1)
stripe element 1
stripe element 5
stripe element 9
stripe element 2
stripe element 6
stripe element 10
stripe element 3
stripe element 7
stripe element 11
stripe element 4
stripe element 8
stripe element 12
stripe element 1
stripe element 2
stripe element 3
stripe element 1 duplicated
stripe element 2 duplicated
stripe element 3 duplicated
stripe element 4 stripe element 4 duplicated
book.book Page 13 Monday, September 15, 2008 2:47 PM
14 Overview
book.book Page 14 Monday, September 15, 2008 2:47 PM
SAS 6/iR Features 15
SAS 6/iR Features
This section provides the specifications of Dellâ„¢ Serial-Attached SCSI (SAS)
6/iR controller. The following table compares the specifications of the
SAS 6/iR Adapter and SAS 6/iR Integrated.
Table 3-1. Specifications of SAS 6/iR
Specification SAS 6/iR Adapter SAS 6/iR Integrated
SAS technology Yes Yes
Support for x4, x8, or x16
PCI Express Host Interface
Yes Yes
Form Factor
Standard-Height,
Half-Length PCI Adapter
Standard-Height, Half-
Length PCI on all systems
except on blade servers
(where the dimension do
not follow industry
standards) and some
Precision workstations
(where the controller has
been integrated on the
mother board)
I/O controller (IOC)
LSI SAS 1068e LSI SAS 1068e
Core Speed: 255 MHz Core Speed: 255 MHz
Operating voltage
requirements
+12V, +3.3V, +3.3Vaux +12V, +3.3V, +3.3Vaux
Communication to the
system
PCI-E lanes System dependent
Communication to end
devices
SAS Links SAS Links
book.book Page 15 Monday, September 15, 2008 2:47 PM
16 SAS 6/iR Features
SAS Connectors 2 x4 Internal 2 x4 Internal connectors on
all systems, with two
exceptions: 4 x1 on
Precision workstations with
controller integrated on the
motherboard, no SAS
connector on the controller
for the blades (I/O is routed
though the PCI connector)
Lead Free Yes Yes
Supported operating
systems
Microsoft
®
Windows Server
®
2003 Family, Windows
®
XP,
Microsoft Windows Server 2008 Family, Windows Vistaâ„¢,
Red Hat
®
Enterprise Linux
®
Versions 4 and 5, SUSE
®
Linux Enterprise Server Version 10.
Dell-compliant SAS and
SATA compatibility
Yes Yes
Dell supported direct
connected end devices
Dell-compliant physical
disks
Dell-compliant physical
disks
SMART error support
through management
applications
Yes Yes
Backplane supported
systems
Yes Yes
Hardware-based RAID RAID 0, RAID 1 RAID 0, RAID 1
Maximum number of
virtual disks
22
Table 3-1. Specifications of SAS 6/iR (continued)
Specification SAS 6/iR Adapter SAS 6/iR Integrated
book.book Page 16 Monday, September 15, 2008 2:47 PM
SAS 6/iR Features 17
Storage management
software
OpenManageâ„¢ Storage
Services, SAS RAID
Storage Manager
OpenManage Storage
Services, SAS RAID
Storage Manager
NOTE: The management software that is supported depends on the specific platform.
Support for internal tape
drive
No No
Support for Global
Hotspare
Yes Yes
Maximum number of
Hotspares
22
Table 3-1. Specifications of SAS 6/iR (continued)
Specification SAS 6/iR Adapter SAS 6/iR Integrated
book.book Page 17 Monday, September 15, 2008 2:47 PM
18 SAS 6/iR Features
book.book Page 18 Monday, September 15, 2008 2:47 PM
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86

Dell UCS-51 Owner's manual

Category
RAID controllers
Type
Owner's manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI