Dell SCSI 6/IR User manual

Category
Disk arrays
Type
User manual
www.dell.com | support.dell.com
Dell™ Serial-Attached SCSI 6/iR
Integrated and Adapter
User’s Guide
book.book Page 1 Wednesday, July 25, 2007 10:58 AM
Notes, Notices, and Cautions
NOTE: A NOTE indicates important information that helps you make better use of your computer.
NOTICE: A NOTICE indicates either potential damage to hardware or loss of data and tells you how to avoid the problem.
CAUTION: A CAUTION indicates a potential for property damage, personal injury, or death.
____________________
Information in this document is subject to change without notice.
© 2007 Dell Inc. All rights reserved.
Reproduction in any manner whatsoever without the written permission of Dell Inc. is strictly forbidden.
Trademarks used in this text: Dell, the DELL logo, Dell Precision, PowerEdge, and OpenManage are trademarks of Dell Inc.; Intel is a registered
trademark of Intel Corporation; Microsoft, Windows, Windows Server, and Windows Vista are either trademarks or registered trademarks of
Microsoft Corporation in the United States and/or other countries; Novell, NetWare, and SUSE are registered trademarks of Novell, Inc. in the
United States and other countries; Red Hat Linux and Red Hat Enterprise Linux are registered trademarks of Red Hat, Inc.; LSI Logic,
Fusion-MPT, Integrated Mirroring, and Integrated Striping are trademarks or registered trademarks of LSI Logic Corporation; DR-DOS is a
registered trademark of DRDOS, Inc.
Other trademarks and trade names may be used in this document to refer to either the entities claiming the marks and names or their products.
Dell Inc. disclaims any proprietary interest in trademarks and trade names other than its own.
Model UCS-61
August 2007 P/N JM360 Rev. A00
book.book Page 2 Wednesday, July 25, 2007 10:58 AM
Contents 3
Contents
CAUTION: Safety Instructions. . . . . . . . . . . . . . . . . . . . . 7
SAFETY: General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
SAFETY: When Working Inside Your System
. . . . . . . . . . . . . . . . . . . 7
SAFETY: Protecting Against Electrostatic Discharge
. . . . . . . . . . . . . . . 8
1 Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
About RAID . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
RAID Levels
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
RAID Terminology
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Integrated Striping
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Integrated Mirroring
. . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
2 SAS 6/iR Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
3 Hardware Installation
. . . . . . . . . . . . . . . . . . . . . . . . . . 15
Installing the SAS 6/iR Adapter . . . . . . . . . . . . . . . . . . . . . . . . . 15
4 Driver Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Creating a Driver Diskette . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Installing the Driver During Windows Operating System Installation
. . . . . 20
Installing a Windows Driver for a New SAS 6/iR Controller
. . . . . . . . . . 20
Updating an Existing Windows Driver
. . . . . . . . . . . . . . . . . . . . . 21
Installing From the Dell Operating System Media
. . . . . . . . . . . . . . . 22
book.book Page 3 Wednesday, July 25, 2007 10:58 AM
4 Contents
Installing the Red Hat Linux Driver . . . . . . . . . . . . . . . . . . . . . . . 22
Creating a Driver Diskette
. . . . . . . . . . . . . . . . . . . . . . . . . 22
Installing the Driver
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Installing the Driver Using an Update RPM
. . . . . . . . . . . . . . . . . 23
Installing the SUSE Linux Enterprise Server Driver
. . . . . . . . . . . . . . . 24
Installing the Driver Using an Update RPM
. . . . . . . . . . . . . . . . . 24
Installing SUSE Linux Enterprise Server Using
the Driver Update Diskette
. . . . . . . . . . . . . . . . . . . . . . . . . 25
Upgrading the Kernel
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
5 SAS 6/iR BIOS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
POST Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
BIOS Fault Code Messages
. . . . . . . . . . . . . . . . . . . . . . . . . 27
Configuration Utility
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
Starting the Configuration Utility
. . . . . . . . . . . . . . . . . . . . . . 28
Functions Performed
. . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
Navigating the Configuration Utility
. . . . . . . . . . . . . . . . . . . . 29
Integrated RAID Configuration and Management Screens
. . . . . . . . . . . 29
Select New Array Type
. . . . . . . . . . . . . . . . . . . . . . . . . . . 29
Create New Array
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
View Array
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
Manage Array
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
Exit Screen
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
Performing Configuration Tasks
. . . . . . . . . . . . . . . . . . . . . . . . . 32
Creating an Integrated Striping Virtual Disk
. . . . . . . . . . . . . . . . 32
Creating a Integrated Mirroring Virtual Disk
. . . . . . . . . . . . . . . . 33
Viewing Virtual Disk Properties
. . . . . . . . . . . . . . . . . . . . . . . 34
Synchronizing a Virtual Disk
. . . . . . . . . . . . . . . . . . . . . . . . 34
Activating a Virtual Disk
. . . . . . . . . . . . . . . . . . . . . . . . . . 34
Deleting a Virtual Disk
. . . . . . . . . . . . . . . . . . . . . . . . . . . 35
Hot Spare Failover
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
Replacing and Rebuilding a Degraded Virtual Disk
. . . . . . . . . . . . 35
book.book Page 4 Wednesday, July 25, 2007 10:58 AM
Contents 5
6 Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
BIOS Boot Order . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
General Problems
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
Physical Disk Related Issues
. . . . . . . . . . . . . . . . . . . . . . . . . . 38
Configuration Utility Error Messages
. . . . . . . . . . . . . . . . . . . . . . 39
BIOS Error Messages
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
A Updating the Firmware. . . . . . . . . . . . . . . . . . . . . . . . . . 43
Firmware Update Utility . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
B Getting Help . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
Obtaining Assistance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
Technical Support and Customer Service
. . . . . . . . . . . . . . . . . 45
Online Services
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
Automated Order-Status Service
. . . . . . . . . . . . . . . . . . . . . . 46
Dell Enterprise Training
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47
Problems With Your Order
. . . . . . . . . . . . . . . . . . . . . . . . . . . . 47
Product Information
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47
Returning Items for Warranty Repair or Credit
. . . . . . . . . . . . . . . . . 47
Before You Call
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48
C Regulatory Notices . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
D Corporate Contact Details (Taiwan Only)
. . . . . . . . . . . . . 53
Glossary
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55
Index
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61
book.book Page 5 Wednesday, July 25, 2007 10:58 AM
6 Contents
book.book Page 6 Wednesday, July 25, 2007 10:58 AM
Safety Instructions 7
CAUTION: Safety Instructions
Use the following safety guidelines to help ensure your own personal safety and to help protect your system and working
environment from potential damage.
NOTE: See the caution and safety statements in your Dell™ PowerEdge™ system or Dell Precision™ workstation.
SAFETY: General
Observe and follow service markings. Do not service any product except as explained in your user documentation. Opening
or removing covers that are marked with the triangular symbol with a lightning bolt may expose you to electrical shock.
Components inside these compartments should be serviced only by a trained service technician.
If any of the following conditions occur, unplug the product from the electrical outlet and replace the part or contact your
trained service provider:
The power cable, extension cable, or plug is damaged.
An object has fallen into the product.
The product has been exposed to water.
The product has been dropped or damaged.
The product does not operate correctly when you follow the operating instructions.
Use the product only with approved equipment.
Operate the product only from the type of external power source indicated on the electrical ratings label. If you are not sure
of the type of power source required, consult your service provider or local power company.
Handle batteries carefully. Do not disassemble, crush, puncture, short external contacts, dispose of in fire or water, or expose
batteries to temperatures higher than 60 degrees Celsius (140 degrees Fahrenheit). Do not attempt to open or service
batteries; replace batteries only with batteries designated for the product.
SAFETY: When Working Inside Your System
Before you remove the system covers, perform the following steps in the sequence indicated.
CAUTION: Except as expressly otherwise instructed in Dell documentation, only trained service technicians are authorized
to remove the system cover and access any of the components inside the system.
NOTICE: To help avoid possible damage to the system board, wait 5 seconds after turning off the system before removing a
component from the system board or disconnecting a peripheral device.
1
Turn off the system and any devices.
2
Ground yourself by touching
an unpainted metal surface on the chassis before touching anything inside the system.
3
While you work, periodically touch an unpainted metal surface on the chassis to dissipate any static electricity that might harm
internal components.
4
Disconnect
your system and devices from their power sources. To reduce the potential of personal injury or shock, disconnect
any telecommunication lines from the system.
book.book Page 7 Wednesday, July 25, 2007 10:58 AM
8 Safety Instructions
In addition, take note of these safety guidelines when appropriate:
When you disconnect a cable, pull on its connector or on its strain-relief loop, not on the cable itself. Some cables have a
connector with locking tabs; if you are disconnecting this type of cable, press in on the locking tabs before disconnecting the
cable. As you pull connectors apart, keep them evenly aligned to avoid bending any connector pins. Also, before you connect
a cable, make sure that both connectors are correctly oriented and aligned.
Handle components and cards with care. Do not touch the components or contacts on a card. Hold a card by its edges or by
its metal mounting bracket. Hold a component such as a microprocessor chip by its edges, not by its pins.
SAFETY: Protecting Against Electrostatic Discharge
Electrostatic discharge (ESD) events can harm electronic components inside your computer. Under certain conditions, ESD may
build up on your body or an object, such as a peripheral, and then discharge into another object, such as your computer. To prevent
ESD damage, you should discharge static electricity from your body before you interact with any of your computer’s internal
electronic components, such as a memory module. You can protect against ESD by touching a metal grounded object (such as an
unpainted metal surface on your computer’s I/O panel) before you interact with anything electronic. When connecting a
peripheral (including handheld digital assistants) to your computer, you should always ground both yourself and the peripheral
before connecting it to the computer. In addition, as you work inside the computer, periodically touch an I/O connector to remove
any static charge your body may have accumulated.
You can also take the following steps to prevent damage from electrostatic discharge:
When unpacking a static-sensitive component from its shipping carton, do not remove the component from the antistatic
packing material until you are ready to install the component. Just before unwrapping the antistatic package, be sure to
discharge static electricity from your body.
When transporting a sensitive component, first place it in an antistatic container or packaging.
Handle all electrostatic sensitive components in a static-safe area. If possible, use antistatic floor pads and work bench pads.
book.book Page 8 Wednesday, July 25, 2007 10:58 AM
Overview 9
Overview
The Dell™ Serial-Attached SCSI (SAS) 6/iR controller is Dell’s next generation controller with
integrated redundant array of independent disks (RAID) capabilities. SAS technology is not
backward compatible with the previous generation of SAS or SCSI devices. The SAS 6/iR Adapter is
a half-length, standard-height PCI-E card, while the SAS 6/iR Integrated is embedded in the
platform hardware. The SAS 6/iR Adapter is supported on platforms with PCI-E x8 or x16 connectors.
Figure 1-1. SAS 6/iR Adapter Hardware Architecture
1 SAS x4 internal connector 2 PCI-E connector
1
2
book.book Page 9 Wednesday, July 25, 2007 10:58 AM
10 Overview
About RAID
RAID is a group of multiple independent physical disks that provide high performance by increasing the
number of drives used for saving and accessing data. A RAID disk subsystem improves I/O performance
and data availability. The physical disk group appears to the host system as a single storage unit or as
multiple logical units. Data throughput improves because multiple disks can be accessed simultaneously.
RAID systems also improve data storage availability and fault tolerance.
RAID Levels
Integrated Striping or RAID 0 uses disk striping to provide high data throughput, especially for large files
in an environment that requires no data redundancy.
Integrated Mirroring or RAID 1 uses disk mirroring so that data written to one physical disk is
simultaneously written to another physical disk. This is good for small databases or other applications
that require small capacity, but complete data redundancy.
NOTICE: Lost data on an Integrated Striping virtual disk cannot be recovered in the event of a physical disk failure.
RAID Terminology
Integrated Striping
Integrated Striping (RAID 0) allows you to write data across multiple physical disks instead of just one
physical disk. Integrated Striping involves partitioning each physical disk storage space into 64 KB stripes.
These stripes are interleaved in a repeated sequential manner. The part of the stripe on a single physical
disk is called a stripe element.
For example, in a four-disk system using only Integrated Striping, segment 1 is written to disk 1, segment 2
is written to disk 2, and so on. Integrated Striping enhances performance because multiple physical disks
are accessed simultaneously, but Integrated Striping does not provide data redundancy. Figure 1-2 shows
an example of Integrated Striping.
Figure 1-2. Example of Integrated Striping (RAID 0)
Stripe element 1
Stripe element 5
Stripe element 9
Stripe element 2
Stripe element 6
Stripe element 10
Stripe element 3
Stripe element 7
Stripe element 11
Stripe element 4
Stripe element 8
Stripe element 12
book.book Page 10 Wednesday, July 25, 2007 10:58 AM
Overview 11
Integrated Mirroring
With Integrated Mirroring (RAID 1), data written to one disk is simultaneously written to another disk.
If one disk fails, the contents of the other disk can be used to run the system and rebuild the failed
physical disk. The primary advantage of Integrated Mirroring is that it provides 100 percent data
redundancy. Because the contents of the disk are completely written to a second disk, it does not matter
if one of the disks fails. Both disks contain the same data at all times. Either physical disk can act as the
operational physical disk.
NOTE: Mirrored physical disks improve read performance by read load balance.
Figure 1-3. Example of Integrated Mirroring (RAID 1)
Stripe element 1
Stripe element 2
Stripe element 3
Stripe element 1 Duplicated
Stripe element 2 Duplicated
Stripe element 3 Duplicated
Stripe element 4 Stripe element 4 Duplicated
book.book Page 11 Wednesday, July 25, 2007 10:58 AM
12 Overview
book.book Page 12 Wednesday, July 25, 2007 10:58 AM
SAS 6/iR Features 13
SAS 6/iR Features
This section provides the specifications of Dell™ Serial-Attached SCSI (SAS) 6/iR controller. The
following table compares the specifications of the SAS 6/iR Adapter and SAS 6/iR Integrated.
Table 2-1. Specifications of SAS 6/iR
Specification SAS 6/iR Adapter SAS 6/iR Integrated
SAS technology Yes Yes
Support for x4, x8, or x16 PCI
Express Host Interface
Yes Yes
Form Factor
Standard-Height, Half-Length PCI
Adapter
System dependent
I/O controller (IOC)
LSI SAS 1068e LSI SAS 1068e
Core Speed: 255 MHz Core Speed: 255 MHz
Operating voltage requirements +12V, +3.3V, +3.3Vaux +12V, +3.3V, +3.3Vaux
Communication to the system PCI-E lanes System dependent
Communication to end devices SAS Links SAS Links
SAS Connectors 2 x4 Internal System dependent
Lead Free Yes Yes
Supported operating systems
Microsoft
®
Windows Server
®
2003
Family, Windows
®
XP, Windows
Vista™ Business 32BIT and Business
64BIT, Red Hat
®
Enterprise Linux
®
Versions 4 and 5, SUSE
®
Linux
Enterprise Server Version 10.
Microsoft Windows Server
2003
Family, Windows XP,
Windows Vista Business 32BIT
and Business 64BIT, Red Hat
Enterprise Linux Versions 4 and 5,
SUSE Linux Enterprise Server
Version 10.
Windows Miniport Interface Storport, SCSIport (Windows XP
32-bit only)
Storport, SCSIport (Windows XP
32-bit only)
Supported drivers for Linux Yes Yes
Dell-compliant SAS and SATA
compatibility
Yes Yes
Dell supported direct connected
end devices
Dell-compliant physical disks Dell-compliant physical disks
book.book Page 13 Wednesday, July 25, 2007 10:58 AM
14 SAS 6/iR Features
Hot add / Hot remove of end devices Yes System dependent
SMART error support through
management applications
Yes Yes
Backplane supported systems Yes Yes
Hardware-based RAID RAID 0, RAID 1 RAID 0, RAID 1
Maximum number of virtual disks 2 2
Storage management software
OpenManage™ Storage Services,
SAS RAID Storage Manager
OpenManage Storage Services,
SAS RAID Storage Manager
Support for internal tape drive No No
Support for Hotspare Yes Yes
Maximum number of Hotspares 2 2
Table 2-1. Specifications of SAS 6/iR (continued)
Specification SAS 6/iR Adapter SAS 6/iR Integrated
book.book Page 14 Wednesday, July 25, 2007 10:58 AM
Hardware Installation 15
Hardware Installation
This chapter describes how to install the Dell™ Serial-Attached SCSI (SAS) 6/iR Adapter.
NOTE: The SAS 6/iR Integrated is embedded on the system motherboard and does not require any installation.
See your system’s Hardware Owner’s Manual or the User’s Guide for instructions.
Installing the SAS 6/iR Adapter
CAUTION: For some systems, only trained service technicians are authorized to remove the system cover
and access any of the components inside the system. Before performing any procedure, see your
Product Information Guide for complete information about safety precautions, working inside the computer,
and protecting against electrostatic discharge.
1
Unpack the SAS 6/iR Adapter and check for damage.
NOTE: Contact Dell if the controller is damaged.
2
Turn off the system and attached peripherals, and disconnect the system from the electrical
outlet. See your system’s
Hardware Owner’s Manual
or the
User’s Guide
for more information
on power supplies.
3
Disconnect the system from the network and remove the cover of the system. See your system’s
Hardware Owner’s Manual
or the
User’s Guide
for more information on opening the system.
4
Select an appropriate
PCI-E slot. Remove the blank filler bracket on the back of the system
aligned with the PCI-E slot you have selected.
NOTE: For more information about your system’s PCI-E slots, see your system’s Hardware Owner’s
Manual.
5
Align the SAS 6/iR Adapter to the P
CI-E
slot you have selected.
6
Insert the controller gently, but firmly, until the controller is firmly seated in the PCI-E slot.
See Figure 3-1.
book.book Page 15 Wednesday, July 25, 2007 10:58 AM
16 Hardware Installation
Figure 3-1. Installing a SAS 6/iR Adapter
7
Tighten the bracket screw, if any, or use the system’s retention clips to secure the controller to the
system’s chassis.
8
Connect the cables from the end devices or the backplane of the system to the controller.
See Figure 3-2.
1 bracket screw 2 SAS 6/iR Adapter 3 PCI-E slot
4 PCI bracket 5 filler bracket
3
2
5
1
4
book.book Page 16 Wednesday, July 25, 2007 10:58 AM
Hardware Installation 17
Figure 3-2. Connecting the Cable
9
Replace the cover of the system. See your system’s
Hardware Owner’s Manual
or the
User’s Guide
for
more information on closing the system.
10
Reconnect the power cable(s) and network cables, and then turn on the system.
1 SAS 6/iR Adapter 2 SAS x4 internal connector 3 cable
3
1
2
book.book Page 17 Wednesday, July 25, 2007 10:58 AM
18 Hardware Installation
book.book Page 18 Wednesday, July 25, 2007 10:58 AM
Driver Installation 19
Driver Installation
The
Dell™ Serial-Attached SCSI (SAS) 6/iR controller
requires software drivers to operate with
Microsoft
®
Windows
®
, Red Hat
®
Linux
®
, and SUSE
®
Linux operating systems.
This chapter contains the procedures for installing the drivers for the following operating systems:
Microsoft Windows Server
®
2003 Server family.
Microsoft Windows XP.
Red Hat Linux Versions 4 and 5.
SUSE Linux Enterprise Server Version 10.
Windows Vista™.
The four methods for installing a driver that are discussed in this chapter are:
During operating system installation.
After adding a new SAS 6/iR controller on an existing operating system.
Updating existing drivers.
Installing from a
Dell Precision™ Workstation Operating System
CD or DVD. This media includes
the drivers.
NOTE: Operating system installation on an Integrated Mirroring or Integrated Striping virtual disk is
supported only when the virtual disk is in an optimal state.
NOTE: Device drivers are frequently updated. To ensure you have the latest version of any driver mentioned
in this section, check the Dell Support website at support.dell.com. If a newer version exists, you can
download the driver to your system.
Creating a Driver Diskette
NOTE: Driver diskette is not needed if you are installing from a Dell Precision™ Workstation Operating System
CD or DVD.
1
Browse to the download section of the system on the Dell Support website at
support.dell.com
.
2
Locate and download the latest SAS 6/iR driver for the system. The drivers are packaged on the
Dell Support website such that they can be written onto a diskette.
3
Follow the instructions on the support site for extracting the driver to the diskette.
book.book Page 19 Wednesday, July 25, 2007 10:58 AM
20 Driver Installation
Installing the Driver During Windows Operating System
Installation
NOTE: You do not need to provide a driver to install the Windows Vista operating system as the driver is native to
this operating system.
To install the driver during Windows operating system installation:
1
Boot the system using the
Microsoft
®
Windows Installation
CD.
2
When the message
Press F6 if you need to install a third party SCSI or
RAID driver
appears, press <F6> immediately.
Within a few minutes, a screen appears that asks for additional controllers in the system.
NOTE: This step is not required for systems running Windows Vista.
3
Press <S>.
The system prompts for the driver diskette to be inserted.
4
Insert the driver diskette in the diskette drive and press <Enter>.
A list of SAS 6/iR drivers appears.
5
Select the appropriate driver and press <Enter> to load the driver.
NOTE: For some Windows operating systems, a message may appear that states that the driver you provided
is older/newer than the Windows driver. Press <S> to use the driver that is on the floppy diskette.
6
Press <Enter> again to continue the installation.
Installing a Windows Driver for a New SAS 6/iR Controller
NOTE: You do not need to provide a driver to install the Windows Vista operating system as the driver is native to
this operating system.
To configure the driver when you add the SAS 6/iR controller to a system that already has Windows
installed:
1
Turn off the system.
2
Install the new SAS 6/iR controller in the system.
See "Hardware Installation" on page 15 for detailed instructions on installing and cabling the
SAS 6/iR controller.
3
Turn on the system.
The Windows operating system should detect the new controller and display a message to inform the user.
NOTE: For systems with Windows Vista, the new controller is configured using the native driver. To ensure
you have the latest version of this driver, check the Dell Support website at support.dell.com. If a newer
version exists, you can download the driver to your system.
book.book Page 20 Wednesday, July 25, 2007 10:58 AM
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62

Dell SCSI 6/IR User manual