Kichler Lighting 52009BK User manual

  • Hello! I am an AI chatbot trained to assist you with the Kichler Lighting 52009BK User manual. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
IS-52009-US
Were here to help 866-558-5706
Hrs: M-F 9am to 5pm EST
7) Pass xture wire from threaded tube aached to upper mounng plate[S]
through coupling[I].
8) Screw coupling[I] onto protruding poron of threaded tube to ghten down
upper nial[U] and mounng plate cover[T].
9) Pass xture wire from the coupling[I] through a stem[M] and threaded
tubes[N] and screw stem into coupling.
NOTE: Thread locking compound must be applied to all stem threads as
noted with symbol (4) to prevent accidental rotaon of xture during
cleaning, relamping, etc.
10) Pass xture wire through desired amount of stems and screw stems together
using supplied short threaded tubes.
11) Pass xture wire from last stem through loop[L]. Thread loop onto end of
last stem.
12) Take threaded pipe[A] from parts bag and screw in screw collar loop[B] a
minimum of 6 mm (1/4”). Lock into place with hexnut[C].
13) Run another hexnut down threaded pipe almost touching rst hexnut.
Now screw threaded pipe into mounng strap[D]. Mounng strap must be
posioned with extruded thread faced into outlet box[E]. Threaded pipe
must protrude out the back of mounng strap. Screw third hexnut onto end
of threaded pipe protruding from back of mounng strap.
14) Connect mounng strap[D] to outlet box using the strap mounng
screws[K].
15) Unscrew the threaded ring[F] from screw collar loop. Take canopy[G] and pass
over screw collar loop. Approximately one half of the screw collar loop exterior
threads should be exposed. Adjust screw collar loop by turning assembly up or
down in mounng strap. Remove canopy.
16) Aer desired posion is found, ghten both top and boom hexnuts up
against the boom and top of the mounng strap.
17) Slip canopy over screw collar loop and thread on threaded ring. Aach chain
link[H] (with xture connected) to screw collar loop. Close the open link by
wrapping with a towel and squeezing closed using pliers. Unscrew threaded
ring, let canopy and threaded ring slip down.
18) Pass electrical wire and ground wire through chain link[H], threaded ring[F],
canopy, screw collar loop, threaded pipe and into outlet box.
19) Grounding instrucons: (See Illus. a or b).
a) On xtures where mounng strap is provided with a hole and two raised
dimples, wrap ground wire from outlet box around green ground screw,
and thread into hole.
b) On xtures where a cupped washer is provided, aach ground wire from
outlet box under cupped washer and green ground screw, then thread
into mounng strap.
If xture is provided with ground wire, connect xture ground wire to outlet
box ground wire with wire connector aer following the above steps. Never
connect ground wire to black or white power supply wires.
20) Make wire connecon. Reference chart below for correct connecons and
wire accordingly.
Connect Black or Red
Supply Wire to:
Connect White Supply
Wire to:
Black White
*Parallel cord (round &
smooth)
*Parallel cord (square &
ridged)
Clear, Brown, Gold or
Black without Tracer
Clear, Brown, Gold or Black
with Tracer
Insulated wire (other
than green) with copper
conductor
Insulated wire (other
than green) with silver
conductor
*Note: When parallel wire (SPT
1 & SPT 2) are used. The neutral
wire is square shaped or ridged
and the other wire will be round
in shape or smooth (See illus.)
Neutral Wire
21) Raise canopy to ceiling.
22) Secure canopy in place by ghtening threaded ring onto screw collar loop.
23) Install the recommended bulbs (not supplied).
24) Carefully lower glass shades[J] to the xture. Slip the smaller opening over
the socket unl seated on the socket.
GREEN GROUND
SCREW
CUPPED
WASHER
OUTLET BOX
GROUND
FIXTURE
GROUND
DIMPLES
WIRE CONNECTOR
OUTLET BOX
GROUND
GREEN GROUND
SCREW
FIXTURE
GROUND
a
b
Fixture Diagram
Parts List
Cauons
CAUTION – RISK OF SHOCK –
Disconnect Power at the main circuit breaker panel or main fusebox before
starng and during the installaon.
WARNING:
This xture is intended for installaon in accordance with the Naonal Electrical
Code (NEC) and all local code specicaons. If you are not familiar with code
requirements, installaon by a cered electrician is recommended.
Installaon Instrucons
1) Aach lower decorave secon[O] to main ring[P] using decorave
screws[Q] (6 places).
2) Locate decorave tube[R] with xture wire already threaded through. Aach
decorave tube [R] to main ring[P] by screwing tube onto threaded pipe
aached to main ring. Repeat for remaining 5 decorave tubes.
3) Aach decorave tube[R] to loop on upper mounng plate[S] using open
chain link[H]. Once aached, close the open chain link by placing a piece
of cloth over the open link and using a pair of pliers gently squeeze the link
closed. Repeat for remaining 5 decorave tubes.
4) Pass xture wire from decorave tube[R] through loop and threaded tube
connected to upper mounng plate[S].
5) Slide mounng plate cover[T] down over upper mounng plate[S], ensuring
the threaded tube aached to the upper mounng plate is protruding
through the center hole of the mounng plate cover.
6) Slide upper nial[U] down over exposed threaded tube onto the top of the
mounng plate cover[T].
Installaon Instrucons (connued)
[A] Threaded Pipe
[B] Screw Collar Loop
[C] Hexnut
[D] Mounting Strap
[E] Outlet Box
[F] Threaded Ring
[G] Canopy
[H] Chain Link
[I] Coupling
[J] Glass Shade
[K] Strap Mounting
Screws
[L] Loop
[M] Stem
[N] Threaded Tubes
[O] Lower Decorative
Section
[P] Main Ring
[Q] Decorative Screws
[R] Decorative Tube
[S] Upper Mounting
Plate
[T] Mounting Plate
Cover
[U] Upper Finial
E
D
C
K
A
G
B
F
H
L
M
N
I
U
T
H
R
O
P
Q
S