  • Hello! I am an AI chatbot trained to assist you with the Extech Instruments 480172 User manual. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
Extechmodel480172v1.14/14
ACLineSplitter‐Model480172
Operation
TheLineSplitterprovidesameanstocleanly“open”astandard120VAClinecordinorderto
makeclamptypecurrentmeasurements.Whenconnectedbetweenthe120VACwalloutlet
andthedeviceundertest,aclampmetercanthenbeclampedaroundoneofthetwotest
openingsintheSplitter.Oneopeningprovidesaonetoonecurrentreadingandtheother
providesatimesten(X10)readingsothatsmallcurrentwilldisplaywithbetterresolutionona
clampmeter.
CurrentMeasurements
1. PlugtheACLineSplitterintothe120Vreceptacle
2. PlugthelinecordfromtheloadintotheACLineSplittersocket
3. ClosetheClamponjawsaroundeithertheX1orX10armoftheACLineSplitter
4. IftheX1positionisused,readthecurrentdirectlyonthemeter
5. IftheX10positionisused,dividethemeterreadingby10toobtaintheactualcurrent
VoltageMeasurements
1. PlugtheACLineSplitterintothe120Vreceptacle
2. InsertthemultimetertestleadsintothetwoVoltageTestjacks
3. Readthevoltageonthemultimeter.
Specifications
Voltage 120V+/10%
Current 15Ampsmax
Temperature Operating;41ºFto104ºF(5ºCto40ºC)
Storage;‐4ºFto140ºF(20ºCto60ºC)
Humidity Operating;Max80%upto87ºF(31ºC)decreasinglinearlyto50%at104ºF
(40ºC),Storage;<80%
Altitude Operating;7000ft.(2000)metersmaximum.
Dimensions: 5.25x 2x
1”(133x51x25mm)
Weight 0.753lb(342g)(includesholster).
Safety Forindooruseandinaccordancewiththerequirementsfordoubleinsulationto
IEC10101(1995):EN610101(1995)OvervoltageCategoryII,PollutionDegree
2.