INSTALLATION & OPERATION
INSTRUCTIONS
i50 Instruments
© 2016 Raymarine UK Limited
81341-3Document number:
06-2016Date:
English (EN)
Trademarkandpatentsnotice
Raymarine,Tacktick,ClearPulse,Truzoom,HSB,SeaTalk,SeaTalkhs,SeaTalkng,Micronet,Raytech,
GearUp,MarineShield,Seahawk,Autohelm,Automagic,andVisionalityareregisteredorclaimed
trademarksofRaymarineBelgium.
FLIR,DownVision,SideVision,Dragony,Quantum,Instalert,InfraredEverywhere,andTheWorld’s
SixthSenseareregisteredorclaimedtrademarksofFLIRSystems,Inc.
Allothertrademarks,tradenames,orcompanynamesreferencedhereinareusedforidenticationonly
andarethepropertyoftheirrespectiveowners.
Thisproductisprotectedbypatents,designpatents,patentspending,ordesignpatentspending.
FairUseStatement
Youmayprintnomorethanthreecopiesofthismanualforyourownuse.Youmaynotmakeanyfurther
copiesordistributeorusethemanualinanyotherwayincludingwithoutlimitationexploitingthemanual
commerciallyorgivingorsellingcopiestothirdparties.
Softwareupdates
Important:ChecktheRaymarinewebsiteforthelatestsoftwarereleasesforyourproduct.
www.raymarine.com/software
Producthandbooks
ThelatestversionsofallEnglishandtranslatedhandbooksareavailabletodownloadinPDFformatfromthewebsite
www.raymarine.com.
Pleasecheckthewebsitetoensureyouhavethelatesthandbooks.
Copyright©2016RaymarineUKLtd.Allrightsreserved.
ENGLISH
Documentnumber:81341-3
Date:06-2016
Contents
Chapter1Importantinformation........................7
CertiedInstallation...................................................7
Wateringress............................................................7
Disclaimer.................................................................7
EMCinstallationguidelines........................................7
Suppressionferrites...................................................8
Connectionstootherequipment.................................8
Declarationofconformity............................................8
Productdisposal........................................................8
Warrantyregistration..................................................8
IMOandSOLAS........................................................8
Technicalaccuracy....................................................9
Chapter2Handbookinformation.......................11
2.1Documentinformation..........................................12
2.2Partssupplied......................................................13
2.3i50Productoverview............................................14
Chapter3Planningtheinstallation...................15
3.1Installationchecklist.............................................16
3.2Compatibletransducers........................................16
3.3Systemprotocols.................................................18
3.4T oolsrequired......................................................18
3.5Selectingadisplaylocation...................................19
3.6Productdimensions..............................................20
3.7Selectingatransducerlocation.............................20
Chapter4Cablesandconnections....................21
4.1Generalcablingguidance.....................................22
4.2DirectPowerConnection......................................22
4.3SeaT alkng®powersupply......................................23
4.4Transducerconnections.......................................25
4.5iTC-5connection..................................................26
4.6NMEA2000networkconnection...........................26
4.7SeaT alkngconnection...........................................27
4.8SeaT alkconnection..............................................28
Chapter5Mounting.............................................29
5.1Mounting.............................................................30
5.2Frontbezel..........................................................31
Chapter6i50Depth.............................................33
6.1i50Depthoperation..............................................34
6.2i50Depthcontrols................................................34
6.3Power.................................................................35
6.4Datamaster.........................................................35
6.5Calibration...........................................................36
6.6Usingthedepthpages..........................................38
6.7Viewingthedepthoffset.......................................39
6.8Alarms.................................................................39
6.9Illumination..........................................................40
Chapter7i50Speed............................................43
7.1i50Speedoperation.............................................44
7.2i50Speedcontrols...............................................44
7.3Power.................................................................45
7.4Calibration...........................................................45
7.5Usingthespeedpages.........................................51
7.6Usingthelog,tripandtemperaturepages..............52
7.7Usingthetimers...................................................52
7.8Illumination..........................................................53
Chapter8i50Tridata...........................................55
8.1i50Tridataoperation............................................56
8.2i50Tridatacontrols...............................................56
8.3Power.................................................................57
8.4Datamaster.........................................................57
8.5Calibration...........................................................58
8.6UsingTridatadepthpages....................................65
8.7UsingTridataspeedpages...................................65
8.8UsingTridatatrip,log,tempandtimerpages...........66
8.9Usingthetimers...................................................66
8.10Alarms...............................................................67
8.11Illumination........................................................68
Chapter9Maintainingyourdisplay...................69
9.1Serviceandmaintenance.....................................70
9.2Condensation......................................................70
9.3Routineequipmentchecks....................................71
9.4Productcleaning..................................................71
9.5Cleaningthedisplaycase.....................................72
9.6Cleaningthedisplayscreen..................................72
Chapter10Troubleshooting...............................73
10.1Troubleshooting.................................................74
10.2Instrumenttroubleshooting..................................75
10.3Poweruptroubleshooting...................................76
10.4Miscellaneoustroubleshooting............................77
Chapter11Technicalsupport............................79
11.1Raymarineproductsupportandservicing.............80
11.2Checkingthesoftwareversion.............................81
11.3Learningresources.............................................81
Chapter12Technicalspecication....................83
12.1T echnicalspecication........................................84
Chapter13Sparesandaccessories..................85
13.1SparesandAccessories.....................................86
13.2SeaT alkng®cablesandaccessories.....................86
13.3SeaT alkngcablekits............................................88
AppendixANMEA2000sentences...................91
5
6i50Depth/i50Speed/i50Tridata
Chapter1:Importantinformation
CertiedInstallation
Raymarinerecommendscertiedinstallationbya
Raymarineapprovedinstaller.Acertiedinstallation
qualiesforenhancedproductwarrantybenets.
ContactyourRaymarinedealerforfurtherdetails,
andrefertotheseparatewarrantydocumentpacked
withyourproduct.
Warning:Productinstallationand
operation
Thisproductmustbeinstalledand
operatedinaccordancewiththe
instructionsprovided.Failuretodoso
couldresultinpersonalinjury,damage
toyourvesseland/orpoorproduct
performance.
Raymarinerecommendscertied
installationbyaRaymarineapproved
installer.Acertiedinstallationqualies
forenhancedproductwarrantybenets.
ContactyourRaymarinedealerfor
furtherdetails,andrefertotheseparate
warrantydocumentpackedwithyour
product.
Warning:Potentialignitionsource
ThisproductisNOTapprovedforusein
hazardous/ammableatmospheres.Do
NOTinstallinahazardous/ammable
atmosphere(suchasinanengineroom
ornearfueltanks).
Warning:Positivegroundsystems
Donotconnectthisunittoasystemwhich
haspositivegrounding.
Caution:Powersupplyprotection
Wheninstallingthisproductensurethe
powersourceisadequatelyprotected
bymeansofasuitably-ratedfuseor
automaticcircuitbreaker.
Warning:Switchoffpowersupply
Ensurethevessel’spowersupplyis
switchedOFFbeforestartingtoinstallthis
product.DoNOTconnectordisconnect
equipmentwiththepowerswitchedon,
unlessinstructedinthisdocument.
Warning:Highvoltage
Thisproductcontainshighvoltage.
Adjustmentsrequirespecializedservice
proceduresandtoolsonlyavailableto
qualiedservicetechnicians.Thereare
nouserserviceablepartsoradjustments.
Theoperatorshouldneverremovethe
coverorattempttoservicetheproduct.
Caution:Transducercable
DoNOTcut,shorten,orsplicethe
transducercable.
DoNOTremovetheconnector.
Ifthecableiscut,itcannotberepaired.
Cuttingthecablewillalsovoidthe
warranty.
Caution:Serviceandmaintenance
Thisproductcontainsnouserserviceable
components.Pleasereferallmaintenance
andrepairtoauthorizedRaymarine
dealers.Unauthorizedrepairmayaffect
yourwarranty.
Wateringress
Wateringressdisclaimer
Althoughthewaterproofratingcapacityofthis
productmeetsthestatedIPXstandard(refertothe
product’sTechnicalSpecication),waterintrusion
andsubsequentequipmentfailuremayoccurifthe
productissubjectedtocommercialhigh-pressure
washing.Raymarinewillnotwarrantproducts
subjectedtohigh-pressurewashing.
Disclaimer
Raymarinedoesnotwarrantthatthisproductis
error-freeorthatitiscompatiblewithproducts
manufacturedbyanypersonorentityotherthan
Raymarine.
Raymarineisnotresponsiblefordamagesorinjuries
causedbyyouruseorinabilitytousetheproduct,
bytheinteractionoftheproductwithproducts
manufacturedbyothers,orbyerrorsininformation
utilizedbytheproductsuppliedbythirdparties.
EMCinstallationguidelines
Raymarineequipmentandaccessoriesconformto
theappropriateElectromagneticCompatibility(EMC)
regulations,tominimizeelectromagneticinterference
betweenequipmentandminimizetheeffectsuch
interferencecouldhaveontheperformanceofyour
system
CorrectinstallationisrequiredtoensurethatEMC
performanceisnotcompromised.
Note:InareasofextremeEMCinterference,
someslightinterferencemaybenoticedonthe
product.Wherethisoccurstheproductandthe
sourceoftheinterferenceshouldbeseparatedby
agreaterdistance.
ForoptimumEMCperformancewerecommend
thatwhereverpossible:
Raymarineequipmentandcablesconnectedto
itare:
Importantinformation7
Atleast1m(3ft)fromanyequipment
transmittingorcablescarryingradiosignalse.g.
VHFradios,cablesandantennas.Inthecase
ofSSBradios,thedistanceshouldbeincreased
to7ft(2m).
Morethan2m(7ft)fromthepathofaradar
beam.Aradarbeamcannormallybeassumed
tospread20degreesaboveandbelowthe
radiatingelement.
Theproductissuppliedfromaseparatebattery
fromthatusedforenginestart.Thisisimportantto
preventerraticbehavioranddatalosswhichcan
occuriftheenginestartdoesnothaveaseparate
battery.
Raymarinespeciedcablesareused.
Cablesarenotcutorextended,unlessdoingsois
detailedintheinstallationmanual.
Note:Whereconstraintsontheinstallation
preventanyoftheaboverecommendations,
alwaysensurethemaximumpossibleseparation
betweendifferentitemsofelectricalequipment,to
providethebestconditionsforEMCperformance
throughouttheinstallation
Suppressionferrites
Raymarinecablesmaybepre-ttedorsupplied
withsuppressionferrites.Theseareimportantfor
correctEMCperformance.Ifferritesaresupplied
separatelytothecables(i.e.notpre-tted),you
musttthesuppliedferrites,usingthesupplied
instructions.
Ifaferritehastoberemovedforanypurpose(e.g.
installationormaintenance),itmustbereplacedin
theoriginalpositionbeforetheproductisused.
Useonlyferritesofthecorrecttype,suppliedby
Raymarineoritsauthorizeddealers.
Whereaninstallationrequiresmultipleferritesto
beaddedtoacable,additionalcableclipsshould
beusedtopreventstressontheconnectorsdue
totheextraweightofthecable.
Connectionstootherequipment
Requirementforferritesonnon-Raymarinecables
IfyourRaymarineequipmentistobeconnected
tootherequipmentusingacablenotsuppliedby
Raymarine,asuppressionferriteMUSTalwaysbe
attachedtothecableneartheRaymarineunit.
Caution:Suncovers
Ifyourproductissuppliedwithasun
cover,toprotectagainstthedamaging
effectsofultraviolet(UV)light,always
tthesuncoverwhentheproductis
notinuse.
Suncoversmustberemovedwhen
travellingathighspeed,whetherin
waterorwhenthevesselisbeing
towed.
Caution:Productcleaning
Whencleaningproducts:
Ifyourproductincludesadisplay
screen,doNOTwipethescreenwith
adrycloth,asthiscouldscratchthe
screencoating.
DoNOTuseabrasive,oracidor
ammoniabasedproducts.
DoNOTuseajetwash.
Caution:Condensation
Certainatmosphericconditionsmay
causeasmallamountofcondensation
toformontheunit'swindow.Thiswill
notdamagetheunitandwillclearafter
theunithasbeenswitchedonforashort
period.
Declarationofconformity
RaymarineUKLtd.declaresthatthisproductis
compliantwiththeessentialrequirementsofEMC
directive2004/108/EC.
TheoriginalDeclarationofConformitycerticate
maybeviewedontherelevantproductpageat
www.raymarine.com.
Productdisposal
Disposeofthisproductinaccordancewiththe
WEEEDirective.
TheWasteElectricalandElectronicEquipment
(WEEE)Directiverequirestherecyclingofwaste
electricalandelectronicequipment.
Warrantyregistration
ToregisteryourRaymarineproductownership,
pleasevisitwww.raymarine.comandregisteronline.
Itisimportantthatyouregisteryourproductto
receivefullwarrantybenets.Yourunitpackage
includesabarcodelabelindicatingtheserialnumber
oftheunit.Youwillneedthisserialnumberwhen
registeringyourproductonline.Youshouldretain
thelabelforfuturereference.
IMOandSOLAS
Theequipmentdescribedwithinthisdocument
isintendedforuseonleisuremarineboatsand
workboatsNOTcoveredbyInternationalMaritime
Organization(IMO)andSafetyofLifeatSea
(SOLAS)CarriageRegulations.
8i50Depth/i50Speed/i50Tridata
Technicalaccuracy
Tothebestofourknowledge,theinformationinthis
documentwascorrectatthetimeitwasproduced.
However,Raymarinecannotacceptliabilityforany
inaccuraciesoromissionsitmaycontain.Inaddition,
ourpolicyofcontinuousproductimprovementmay
changespecicationswithoutnotice.Asaresult,
Raymarinecannotacceptliabilityforanydifferences
betweentheproductandthisdocument.Please
checktheRaymarinewebsite(www.raymarine.com)
toensureyouhavethemostup-to-dateversion(s)of
thedocumentationforyourproduct.
Importantinformation9
10i50Depth/i50Speed/i50Tridata
Chapter2:Handbookinformation
Chaptercontents
2.1Documentinformationonpage12
2.2Partssuppliedonpage13
2.3i50Productoverviewonpage14
Handbookinformation11
2.1Documentinformation
Thisdocumentcontainsimportantinformation
relatedtotheinstallationofyourRaymarineproduct.
Thedocumentincludesinformationtohelpyou:
planyourinstallationandensureyouhaveallthe
necessaryequipment;
installandconnectyourproductaspartofawider
systemofconnectedmarineelectronics;
troubleshootproblemsandobtaintechnical
supportifrequired.
ThisandotherRaymarineproductdocuments
areavailabletodownloadinPDFformatfrom
www.raymarine.com.
Applicableproducts
Thisdocumentisapplicabletothefollowingproducts:
ItemModel
Part
numberHardware
Dep th Alarm Offse t Re se t
i50DepthE70059i50Depth
SeaTalkng
instrumentdisplay
Dep th Alarm Offset R es e t
i50Depth
Thru-hull
systempack
E70148i50Depth
SeaTalkng
instrument
display
P319Thru-
hullDepth
transducer
Spe ed Trip Timer Res et
i50SpeedE70058i50Speed
SeaTalkng
instrumentdisplay
Spe ed Trip Timer Res e t
i50Speed
Thru-hull
systempack
E70147i50Speed
SeaTalkng
instrument
display
P120Thru-
hullSpeed
andTemp
transducer
Dep th Sp ee d Trip Re se t
i50TridataE70060i50Tridata
SeaTalkng
instrumentdisplay
ItemModel
Part
numberHardware
Dep th Sp ee d Trip Res e t
i50Tridata
Thru-hull
systempack
E70149i50Tridata
SeaTalkng
instrument
display
P319Thru-
hullDepth
transducer
P120Thru-
hullSpeed
andTemp
transducer
Depth Alarm Offset ResetSpe e d Trip Timer Reset TackTrue/AppDisplay VMG
i50&i60
Depth,
Speed&
Windsystem
pack
E70153i50Depth
SeaTalkng
instrument
display
P319Thru-
hullDepth
transducer
i50Speed
SeaTalkng
instrument
display
P120Thru-
hullSpeed
andTemp
transducer
i60Wind
SeaTalkng
instrument
display
Shortarm
windvane
transducer
Documentillustrations
Yourproductmaydifferslightlyfromthatshown
intheillustrationsinthisdocument,dependingon
productvariantanddateofmanufacture.
Allimagesareprovidedforillustrationpurposesonly.
12i50Depth/i50Speed/i50Tridata
Productdocumentation
Thefollowingdocumentationisapplicabletoyour
product:
Handbooks
DescriptionPartnumber
i50Installationandoperation
instructions
Installationandoperationinstructions
forthei50instrumentdisplay
81341/88009
i50Mountingtemplate
Surfacemountingtemplateforthei50
instrumentdisplay
87130
RotavectaInstallationinstructions
Installationinstructionsforthe
Rotavectawindtransducer
87221/88036
Short&longarmwindvane
Installationinstructions
Installationinstructionsfortheshortand
longarmwindvanetransducers
87220/88035
DepthandSpeedTransducer
installationinstructions
Installationinstructionsforspeedand
depthtransducers,assuppliedwith
yourtransducer
2.2Partssupplied
D12 388- 2
12
56
7
4
8
10
9
3
1Instrumentdisplay
2Frontbezel(eSstyle)
3Frontbezel(a,c,eseriesstyle)
4Gasket
5Suncover
6Documentation
7SeaTalkngblankingplug
8SeaTalkngspurcable
94xxingscrews
10SeaTalktoSeaTalkngadaptorcable
Handbookinformation13
2.3i50Productoverview
Thei50rangeofSeaT alknginstrumentdisplayscan
beconnecteddirectlytotherelevanttransducers.
ThedatacanbetransmittedontheSeaTalkng
networktoothercompatibledisplays.
Re se tSpee dDept h Trip
ResetAlarmDept h O set ResetTripSpee d Timer
12
3
D12 5 29-1
1.i50Depth
2.i50Speed
3.i50Tridata
Thei50instrumentdisplayrangeoffersthefollowing
features:
IntegrateswithRaymarineautopilotsand
navigationequipmentontheSeaT alkngnetwork
Surfacemountable
Extralarge(28mmmax)digits
Providesgoodvisibilityinalllightingconditions
Lowpowerconsumption
14i50Depth/i50Speed/i50Tridata
Chapter3:Planningtheinstallation
Chaptercontents
3.1Installationchecklistonpage16
3.2Compatibletransducersonpage16
3.3Systemprotocolsonpage18
3.4Toolsrequiredonpage18
3.5Selectingadisplaylocationonpage19
3.6Productdimensionsonpage20
3.7Selectingatransducerlocationonpage20
Planningtheinstallation15
3.1Installationchecklist
Installationincludesthefollowingactivities:
InstallationTask
1Planyoursystem.
2Obtainallrequiredequipmentandtools.
3Siteallequipment.
4Routeallcables.
5Drillcableandmountingholes.
6Makeallconnectionsintoequipment.
7Secureallequipmentinplace.
8Poweronandtestthesystem.
Schematicdiagram
Aschematicdiagramisanessentialpartofplanning
anyinstallation.Itisalsousefulforanyfuture
additionsormaintenanceofthesystem.The
diagramshouldinclude:
Locationofallcomponents.
Connectors,cabletypes,routesandlengths.
3.2Compatibletransducers
InstrumentDepthtransducers
Thedepthtransducerslistedbelowarecompatible
withthefollowinginstrumentdisplays:
i40Depth/i40Bidata
i50Depth/i50Tridata
i70/i70sviaiTC-5converter
Part
numberImageMountingHousing
E26009Thru-hullP7
E26019–
PZ
Thru-hullB45(including
fairingblock)
M78717Thru-hullB17
M78713–
PZ
Thru-hullP319
E26030Thru-hullP17
E26001–
PZ
In-hullP79
A80373
T70278
(in-
cludes
SeaTal-
kngadap-
tor)
In-hullP79S
E26027–
PZ
Transom
mount
P66
InstrumentSpeedandTemperature
transducers
Thespeedandtemperaturetransducerslistedbelow
arecompatiblewiththefollowinginstrumentdisplays:
16i50Depth/i50Speed/i50Tridata
i40Speed/i40Bidata
i50Speed/i50Tridata
i70/i70sviaiTC-5converter
Part
numberImageMountingHousing
E26008Thru-hullP371
E26005Transom
mount
ST69
E26031Thru-hullP120/ST800
M78716Thru-hullB120
E25025Thru-hullP17
InstrumentDepth,SpeedandTemperature
(DST)transducers
TheDSTtransducerslistedbelowarecompatible
withthefollowinginstrumentdisplays:
i40Depth/i40Speed/i40Bidata
i50Depthi50Speed/i50Tridata
i70/i70sviaiTC-5converter
Part
numberImageMountingHousing
E26006–
PZ
Transom
mount
P66/ST40
A26043Thru-hullB744V
(including
fairingblock)
Part
numberImageMountingHousing
A26044Thru-hullB744VL
(including
fairingblock)
E26028–
PZ
Transom
mount
P66
Planningtheinstallation17
3.3Systemprotocols
Yourproductcanbeconnectedtovariousproducts
andsystemstoshareinformationandsoimprove
thefunctionalityoftheoverallsystem.These
connectionsmaybemadeusinganumberof
differentprotocols.Fastandaccuratedatacollection
andtransferisachievedbyusingacombinationof
thefollowingdataprotocols:
SeaTalkng®
NMEA2000
SeaTalk
Note:Youmayndthatyoursystemdoesnot
usealloftheconnectiontypesorinstrumentation
describedinthissection.
Seatalkng®
SeaTalkng(NextGeneration)isanenhanced
protocolforconnectionofcompatiblemarine
instrumentsandequipment.Itreplacestheolder
SeaTalkandSeaTalk2protocols.
SeaTalkngutilizesasinglebackbonetowhich
compatibleinstrumentsconnectusingaspur.Data
andpowerarecarriedwithinthebackbone.Devices
thathavealowdrawcanbepoweredfromthe
network,althoughhighcurrentequipmentwillneed
tohaveaseparatepowerconnection.
SeaTalkngisaproprietaryextensiontoNMEA2000
andtheprovenCANbustechnology.Compatible
NMEA2000andSeaTalk/SeaTalk2devicescan
alsobeconnectedusingtheappropriateinterfaces
oradaptorcablesasrequired.
NMEA2000
NMEA2000offerssignicantimprovementsover
NMEA0183,mostnotablyinspeedandconnectivity.
Upto50unitscansimultaneouslytransmitand
receiveonasinglephysicalbusatanyonetime,
witheachnodebeingphysicallyaddressable.The
standardwasspecicallyintendedtoallowfor
awholenetworkofmarineelectronicsfromany
manufacturertocommunicateonacommonbusvia
standardizedmessagetypesandformats.
SeaTalk
SeaTalkisaprotocolwhichenablescompatible
instrumentstoconnecttoeachotherandsharedata.
TheSeaTalkcablesystemisusedtoconnect
compatibleinstrumentsandequipment.Thecable
carriespoweranddataandenablesconnection
withouttheneedforacentralprocessor.
Additionalinstrumentsandfunctionscanbeaddedto
aSeaTalksystem,simplybypluggingthemintothe
network.SeaTalkequipmentcanalsocommunicate
withothernon-SeaT alkequipmentviatheNMEA
0183standard,providedasuitableinterfaceisused.
3.4Toolsrequired
Toolsrequiredforinstallation
D12 5 30-1
3
4
2
15
1Pozi-drivescrewdriver
2File
392mm(3.62in)holecutter
4Adhesivetape
5Powerdrill
18i50Depth/i50Speed/i50Tridata
3.5Selectingadisplaylocation
Warning:Potentialignitionsource
ThisproductisNOTapprovedforusein
hazardous/ammableatmospheres.Do
NOTinstallinahazardous/ammable
atmosphere(suchasinanengineroom
ornearfueltanks).
Generallocationrequirements
Whenselectingalocationfortheunititisimportant
toconsideranumberoffactors.
Ventilationrequirements
Toprovideadequateairow:
Ensurethatequipmentismountedina
compartmentofsuitablesize.
Ensurethatventilationholesarenotobstructed.
Ensureadequateseparationofequipment.
Mountingsurfacerequirements
Ensureunitsareadequatelysupportedonasecure
surface.DoNOTmountunitsorcutholesinplaces
whichmaydamagethestructureofthevessel.
Cableroutingrequirements
Ensuretheunitismountedinalocationwhichallows
properroutingandconnectionofcables:
Minimumcablebendradiusof100mm(3.94in)is
requiredunlessotherwisestated.
Usecablesupportstopreventstresson
connectors.
Electricalinterference
Selectalocationthatisfarenoughawayfrom
devicesthatmaycauseinterference,suchas
motors,generatorsandradiotransmitters/receivers.
Magneticcompass
Whenchoosingasuitablelocationyoushouldaim
tomaintainthemaximumpossibledistancebetween
theunitandanycompasses.
Topreventpotentialinterferencewiththevessel's
magneticcompasses,ensurethataminimum
distanceof230mm(9in)betweentheunitandany
installedcompassesismaintained.
Viewingangleconsiderations
Asdisplaycontrast,colorandnightmode
performanceareallaffectedbytheviewingangle,
Raymarinerecommendsyoutemporarilypowerup
thedisplaywhenplanningtheinstallation,toenable
youtobestjudgewhichlocationgivestheoptimum
viewingangle.
Viewingangle
Dxxxxx-1
70° 70°
70°
70°
Planningtheinstallation19
3.6Productdimensions
D12 3 89-1
A C G
D E
BF
A110mm(4.22”)
B115mm(4.52”)
C14mm(0.55”)
D30mm(1.18”)
E35mm(1.38”)
F90mm(3.54”)
G17mm(0.67”)
3.7Selectingatransducerlocation
Generalspeedanddepthtransducerlocation
requirements
Whenselectingalocationforyourtransduceritis
importanttoconsideranumberoffactors.
Thetransducershouldbemountedwithintheclear
waterowareasindicatedbytheshadedareasin
theimagebelow.
D 4349-2
1
2
3
1Sailingvessel
2Planingpowervessel
3Displacementpowervessel
Eachtransducershouldalso:
Beaheadofthepropellers(byaminimumof10%
ofthewaterlinelength).
Beatleast150mm(6in)awayfromthekeel
(ideallyaheadofthekeelonasailingyacht).
Beasnearaspossibletothecenterlineofthe
vessel.
Beclearofotherthrough-hullttingsorprojections.
Havesufcientclearanceinsidethehulltotthe
nut.
Have100mm(4in)ofheadroomtoallowfor
withdrawal.
Note:Inadditiontotheaboverequirements,the
depthtransducermustbemountedwithin10ºof
thevertical.
D4350 -5
20i50Depth/i50Speed/i50Tridata
/