7
2
3
4
5
6
9
10
12
6
19
1
11
20
13
14
15
18
17
8
16
1)
2)
2)
Fig. IPB 1
Assembly
1 Assemble hanger control valve (20) to
drum cover (17).
2 Assemble pump (9) to drum cover
top (17) with four screws (14).
3 If pumping heavy grease that requires a
follower, place an optional follower into
grease in open 120 lb. (54 kg) drum.
4 Place drum cover assembly (17) onto
drum while placing tube through
follower, if used. Screw in three thumb
screws (13) to secure drum cover to
drum.
5 Assemble outlet adapter (4) to air motor
inlet. Insert air nipple (3) into
adapter and tighten.
6 Assemble air hose (1) to air coupler (2)
and tighten.
7 If meter is used, connect union
adapter (12) and swivel adapter (10) to
pump outlet. Attach meter (8) to swivel
adapter (10) and tighten.
8 Attach volume hose assembly (11) to
outlet of meter and tighten.
9 If no meter is used, connect swivel
adapter (10) directly into pump outlet
and hose (11) into swivel adapter (10).
1)
1
/4 in NPTF
2)
1
/2 in NPTF
10 Assemble control valve (7), if used, to
outlet end of volume hose assembly (11)
and tighten.
11 Unit is operational when
air delivery hose (1) is connected
to pump (9).
note
Tighten all joints to ensure connections
will withstand air pressure.
3