Gefen EXT-IP-2-RS2322 User manual

Category
Supplementary music equipment
Type
User manual

Gefen EXT-IP-2-RS2322 allows IP control of two RS-232-enabled devices. It supports Telnet and UDP protocols. Each of the RS-232 devices can be addressed independently. It's configurable via Web server interface.

Gefen EXT-IP-2-RS2322 allows IP control of two RS-232-enabled devices. It supports Telnet and UDP protocols. Each of the RS-232 devices can be addressed independently. It's configurable via Web server interface.

EXT-IP-2-RS2322
User Manual
IP to RS-232
Converter
*Preferred
Release A4
ii
1. Read these instructions.
2. Keep these instructions.
3. Heed all warnings.
4. Follow all instructions.
5. Do not use this product near water.
6. Clean only with a dry cloth.
7. Do not block any ventilation openings. Install in accordance with the manufacturer’s
instructions.
8. Do not install or place this product near any heat sources such as radiators, heat
registers, stoves, or other apparatus (including ampliers) that produce heat.
9. Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized
plug has two blades with one wider than the other. A grounding type plug has two
blades and a third grounding prong. The wide blade or the third prong are provided for
your safety. If the provided plug does not t into your outlet, consult an electrician for
replacement of the obsolete outlet.
10. Protect the power cord from being walked on or pinched particularly at plugs,
convenience receptacles, and the point where they exit from the apparatus.
11. Only use attachments/accessories specied by the manufacturer.
12. To reduce the risk of electric shock and/or damage to this product, never handle or
touch this unit or power cord if your hands are wet or damp. Do not expose this
product to rain or moisture.
13. Unplug this apparatus during lightning storms or when unused for long periods of time.
14. Refer all servicing to qualied service personnel. Servicing is required when the
apparatus has been damaged in any way, such as power-supply cord or plug is
damaged, liquid has been spilled or objects have fallen into the apparatus,
the apparatus has been exposed to rain or moisture, does not operate normally,
or has been dropped.
15. Batteries that may be included with this product and/or accessories should never be
exposed to open ame or excessive heat. Always dispose of used batteries
according to the instructions.
Important Safety Instructions
iii
Gefen warrants the equipment it manufactures to be free from defects in material and
workmanship.
If equipment fails because of such defects and Gefen is notied within two (2) years from
the date of shipment, Gefen will, at its option, repair or replace the equipment, provided
that the equipment has not been subjected to mechanical, electrical, or other abuse or
modications. Equipment that fails under conditions other than those covered will be
repaired at the current price of parts and labor in effect at the time of repair. Such repairs
are warranted for ninety (90) days from the day of reshipment to the Buyer.
This warranty is in lieu of all other warranties expressed or implied, including without
limitation, any implied warranty or merchantability or tness for any particular purpose, all of
which are expressly disclaimed.
1. Proof of sale may be required in order to claim warranty.
2. Customers outside the US are responsible for shipping charges to and from Gefen.
3. Copper cables are limited to a 30 day warranty and cables must be in their original
condition.
The information in this manual has been carefully checked and is believed to be accurate.
However, Gefen assumes no responsibility for any inaccuracies that may be contained
in this manual. In no event will Gefen be liable for direct, indirect, special, incidental, or
consequential damages resulting from any defect or omission in this manual, even if
advised of the possibility of such damages. The technical information contained herein
regarding the features and specications is subject to change without notice.
For the latest warranty coverage information, refer to the Warranty and Return Policy under
the Support section of the Gefen Web site at www.gefen.com.
Warranty Information
iv
Technical Support
(818) 772-9100 (800) 545-6900
8:00 AM to 5:00 PM Monday - Friday, Pacic Time
Fax
(818) 772-9120
Email
Web
http://www.gefen.com
Mailing Address
Gefen, LLC
c/o Customer Service
20600 Nordhoff St.
Chatsworth, CA 91311
Product Registration
Register your product here: http://www.gefen.com/kvm/Registry/Registration.jsp
iv
Contacting Gefen Technical Support
vv
Operating Notes
Always make sure that the IP to 2 x RS-232 Converter is running the latest rmware.
The Gefen Syner-G™ Software Suite is a free downloadable application from Gefen
that provides automatic download and installation of rmware upgrades for this
product. Syner-G™ is also used to congure this product on a network.
Download the application here: http://www.gefen.com/synerg/
IP to 2 x RS-232 Converter is a trademark of Gefen, LLC.
© 2015 Gefen, LLC. All Rights Reserved. All trademarks are the property of their respective owners.
Gefen, LLC reserves the right to make changes in the hardware, packaging, and any accompanying documentation
without prior written notice.
Pb
This product uses UL or CE listed power supplies.
vi
Licensing
lwIP is licenced under the BSD licence:
Copyright (c) 2001-2004 Swedish Institute of Computer Science.
All rights reserved.
Redistribution and use in source and binary forms, with or without modication,
are permitted provided that the following conditions are met:
1. Redistributions of source code must retain the above copyright notice, this list of
conditions and the following disclaimer.
2. Redistributions in binary form must reproduce the above copyright notice, this list of
conditions and the following disclaimer in the documentation and/or other materials
provided with the distribution.
3. The name of the author may not be used to endorse or promote products derived from
this software without specic prior written permission.
THIS SOFTWARE IS PROVIDED BY THE AUTHOR “AS IS” AND ANY EXPRESS
OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED
WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE
ARE DISCLAIMED. IN NO EVENT SHALL THE AUTHOR BE LIABLE FOR ANY DIRECT,
INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES
(INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR
SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION)
HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT,
STRICT LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING
IN ANY WAY OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE
POSSIBILITY OF SUCH DAMAGE.
vii
Features and Packing List
Features
Allows IP control of two RS-232-enabled devices
Supports Telnet and UDP protocols
Each of the RS-232 devices can be addressed independently
Congurable via Web server interface
Independently congurable RS-232 baud rate and line delay for each RS-232 port
Gefen Discovery Tool-compatible
Field-upgradable rmware via Web server interface
Locking power supply connector
Surface-mountable
Packing List
The IP to 2 x RS-232 Converter ships with the items listed below. If any of these items are
not present in your box when you rst open it, immediately contact your dealer or Gefen.
1 x IP to 2 x RS-232 Converter
1 x 5V DC Power Supply
1 x Quick-Start Guide
viii
Table of Contents
1 Getting Started
Introduction............................................................................................................ 2
Installation ............................................................................................................. 4
Connection Instructions ................................................................................. 4
Sample Wiring Diagram ................................................................................ 4
2 Basic Operation
IP Conguration ..................................................................................................... 8
Using Syner-G™ ........................................................................................... 8
RS-232 Interface ................................................................................................. 10
RS-232 Interface ......................................................................................... 10
RS-232 Settings .......................................................................................... 10
Web Interface .......................................................................................................11
Using the built-in Web Interface .................................................................. 11
RS-232 ........................................................................................................ 12
Network tab ................................................................................................. 18
System tab .................................................................................................. 24
3 Advanced Operation
Commands .......................................................................................................... 28
4 Appendix
Default Settings ................................................................................................... 72
RS-232 ........................................................................................................ 72
Network ....................................................................................................... 73
Specications ...................................................................................................... 74
This page left intentionally blank.
This page left intentionally blank.
IP to RS-232
Converter
1 Getting Started
page | 2
Introduction
RS-232 1 PowerIP Reset
EXT-IP-2-RS2322
Gefen
5V DC IP control RS-232 2
IP to 2xRS-232
Converter
RS-232 1 PowerIP Reset
EXT-IP-2-RS2322
Gefen
5V DC IP control RS-232 2
IP to 2xRS-232
Converter
RS-232 1 PowerIP Reset
EXT-IP-2-RS2322
Gefen
5V DC IP control RS-232 2
IP to 2xRS-232
Converter
64 5
32
Getting Started
Getting Started
1
page | 3
Introduction
ID Name Description
1 IP Reset Resets the unit to its default IP settings.
2 RS-232 1 Connect an RS-232 cable from this port to an
RS-232 device. See Installation (page 4)
for more information.
3 Power This LED will glow bright blue when the unit
is powered.
4 5V DC Connect the included 5V DC power supply to
this power receptacle.
5 IP control Connect an Ethernet cable between
this jack and an IP-based automation control
device
6 RS-232 2 Connect an RS-232 cable from this port to an
RS-232 device. See Installation (page 4)
for more information.
Getting Started
page | 4
Installation
Getting Started
Connection Instructions
1. Connect an Ethernet cable between the IP-based control device and the IP control
port on the IP to 2 x RS-232 Converter.
An Ethernet switch can also exist between the IP to 2 x RS-232 Converter and the
IP-based control device (see Sample Wiring Diagram below).
2. Connect an RS-232 device to each of the RS-232 ports (RS-232 1 and RS-232 2) on
the IP to 2 x RS-232 Converter.
3. Connect the included 5V DC locking power supply to the 5V DC power receptacle on
the IP to 2 x RS-232 Converter. Do not overtighten the locking power connectors.
4. Connect the AC power cord from the power supply to an available electrical outlet.
Sample Wiring Diagram
DB-9 CABLE
RS-232-enabled
Device
CAT-5 CABLE
IP-based Automation
Control Device
Ethernet Switch
EXT-IP-2-RS2322
RS-232-enabled
Device
EXT-IP-2-RS2322
This page left intentionally blank.
This page left intentionally blank.
page | 7
IP to RS-232
Converter
2 Basic Operation
page | 8
Basic Operation
Basic Operation
IP Conguration
Using Syner-G™
When using the IP to 2 x RS-232 Converter for the rst time, it is recommended that the
unit be congured using the Gefen Syner-G™ Software Suite. The Gefen Syner-G™
Software Suite is free software that is available from the Gefen Web site.
1. Download and install the Gefen Syner-G™ Software Suite. Download the application
here: http://www.gefen.com/synerg/
2. Connect an Ethernet cable from the network to the IP control port on the product.
3. Launch the Gefen Syner-G™ Software Suite.
4. Click the EXT-IP-2-RS-2322 from the product list.
page | 9
Basic Operation
5. Under the Device Settings section, enter the desired IP address, subnet mask,
gateway IP address, Web GUI port, and Telnet port in the supplied elds.
If desired, the Description eld can be changed as well. This is useful to identify if
you have multiple units running on a network.
6. Click the Save button at the bottom right-corner of the screen.
7. Click the Reboot button.
8. Click the Web GUI link, above the Reboot button, to access the built-in web interface.
The following table lists the default IP settings for the IP to 2 x RS-232 Converter.
Description IP Address / Port Description IP Address / Port
IP Address
192.168.1.72
UDP Port
23
Subnet
255.255.255.0
Local UDP Port
50007
Gateway
192.168.1.254
Remote UDP IP
192.168.1.255
HTTP Port
80
Remote UDP Port
50008
IP Conguration
Basic Operation
Basic Operation
page | 10
RS-232 Interface
RS-232 Interface
Only TXD, RXD, and GND pins are used.
RS-232 Settings
Description Setting
Baud rate
19200
Data bits
8
Parity
None
Stop bits
1
Hardware ow control
None
The command set on the following pages can be used to control the settings of the
IP to 2 x RS-232 Converter, via RS-232.
DA-15
DE-9
DB-25
DC-37
DD-50
5
6
4
7
3
8
2
9
1
DCD
RXD
TXD
DTR
GND
DSR
RTS
CTS
R1
DCD
RXD
TXD
DTR
GND
DSR
RTS
CTS
R1
1
2
3
4
5
6
7
8
9
1
2
3
4
5
6
7
8
9
RS-232 Controller Switcher
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86

Gefen EXT-IP-2-RS2322 User manual

Category
Supplementary music equipment
Type
User manual

Gefen EXT-IP-2-RS2322 allows IP control of two RS-232-enabled devices. It supports Telnet and UDP protocols. Each of the RS-232 devices can be addressed independently. It's configurable via Web server interface.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI