31-11125-2
Installation
4
CONVERSION TO PROPANE (LP)
OR NATURAL GAS
The pressure regulator and the burner orifices are
VHWIRUHLWKHUQDWXUDOJDVRUSURSDQH/3JDVDWWKH
IDFWRU\GHSHQGLQJRQWKHPRGHOQXPEHU7RFRQYHUW
WRDGLIIHUHQWJDVRWKHUWKDQZKDW\RXUSUHVVXUH
UHJXODWRUZDVVHWWRWKHUHJXODWRUDQGEXUQHURULILFHV
PXVWEHFRQYHUWHGWKHFRQYHUVLRQPXVWEHSHUIRUPHG
E\DTXDOLILHGSURSDQH/3JDVLQVWDOOHU
Keep these instructions and all orifices in case you
ZDQWWRFRQYHUWEDFNWRQDWXUDOJDV
5
GAS SUPPLY
WARNING
)LUH+D]DUG'RQRWXVHDIODPHWR
FKHFNIRUJDVOHDNV
WARNING
([SORVLRQ+D]DUG'RQRWH[FHHG
IWOEVRIWRUTXHZKHQPDNLQJJDVOLQHFRQQHFWLRQV
2YHUWLJKWHQLQJPD\GDPDJHWKHSUHVVXUHUHJXODWRU
UHVXOWLQJLQILUHRUH[SORVLRQKD]DUG
Gas Pressure Regulator
You must use the gas pressure regulator supplied
ZLWKWKLVUDQJH)RUSURSHURSHUDWLRQVWKHLQOHW
SUHVVXUHWRWKHUHJXODWRUVKRXOGEHDVIROORZV
Natural Gas:
0LQLPXPSUHVVXUH´RI:DWHU&ROXPQ
0D[LPXPSUHVVXUH´RI:DWHU&ROXPQ
Propane (LP) Gas:
0LQLPXPSUHVVXUH´RI:DWHU&ROXPQ
0D[LPXPSUHVVXUH´RI:DWHU&ROXPQ
If you are not sure about the inlet pressure contact
local gas supplier.
NOTE: This range is
HTXLSSHGZLWKDJDV
VKXWRIIYDOYHORFDWHG
at the rear of the range
near the floor. This
VKXWRIIYDOYHLVWREH
XVHGLQWKHHYHQWWKDW
VHUYLFHLVUHTXLUHG7R
DFFHVVWKHVKXWRII
YDOYHUHPRYHWKHWRH
NLFNSDQHODQGUHDFK
under the range.
5
GAS SUPPLY (cont.)
Shut off the main gas supply valve before
disconnecting the old range and leave it off until
the new hook-up has been completed. Don’t
forget to relight the pilot on other gas appliances
when you turn the gas back on.
%HFDXVHKDUGSLSLQJUHVWULFWVPRYHPHQWRIWKHUDQJH
WKHXVHRID&6$,QWHUQDWLRQDOFHUWLILHGIOH[LEOHPHWDO
appliance connector is recommended unless local
FRGHVUHTXLUHDKDUGSLSHGFRQQHFWLRQ
,IWKHKDUGSLSLQJPHWKRGLVXVHG\RXPXVWFDUHIXOO\
DOLJQWKHSLSHWKHUDQJHFDQQRWEHPRYHGDIWHUWKH
connection is made.
7RSUHYHQWJDVOHDNVSXWSLSHWKUHDGVHDODQWRQRU
ZUDSSLSHWKUHDGWDSHZLWK7HIORQDURXQGDOOPDOH
H[WHUQDOSLSHWKUHDGV
$ ,QVWDOODPDQXDOVKXWRIIYDOYHLQWKHJDVOLQHLQDQ
HDVLO\DFFHVVHGORFDWLRQRXWVLGHRIWKHUDQJH0DNH
VXUHHYHU\RQHRSHUDWLQJWKHUDQJHNQRZVZKHUH
DQGKRZWRVKXWRIIWKHJDVVXSSO\WRWKHUDQJH
% ,QVWDOOPDOH´IODUHXQLRQDGDSWHUWRWKH´
137LQWHUQDOWKUHDGDWLQOHWRIWKHVKXWRIIYDOYHRQ
WKHUDQJH8VHDEDFNXSZUHQFKRQWKHVKXWRII
YDOYHWRDYRLGGDPDJH
& ,QVWDOOPDOH´RU´IODUHXQLRQDGDSWHUWRWKH
137LQWHUQDOWKUHDGRIWKHKRXVHVKXWRIIYDOYH
WDNLQJFDUHWREDFNXSWKHVKXWRIIYDOYHWRNHHSLW
from turning.
' &RQQHFWIOH[LEOHPHWDODSSOLDQFHFRQQHFWRUWRWKH
DGDSWHURQWKHUDQJH3RVLWLRQUDQJHWRSHUPLW
FRQQHFWLRQDWWKHKRXVHVKXWRIIYDOYH
( :KHQDOOFRQQHFWLRQVKDYHEHHQPDGHPDNHVXUH
all range controls are in the off position and turn
RQWKHPDLQJDVVXSSO\YDOYH8VHDOLTXLGOHDN
GHWHFWRUDWDOOJDVFRQQHFWLRQVWRFKHFNIRUOHDNV
in the system.
:KHQXVLQJSUHVVXUHVJUHDWHUWKDQSVLJWR
SUHVVXUHWHVWWKHJDVVXSSO\V\VWHPRIWKHUHVLGHQFH
GLVFRQQHFWWKHUDQJHDQGLQGLYLGXDOVKXWRIIYDOYH
IURPWKHJDVVXSSO\SLSLQJ:KHQXVLQJSUHVVXUHV
RISVLJRUOHVVWRSUHVVXUHWHVWWKHJDVVXSSO\
V\VWHPVLPSO\LVRODWHWKHUDQJHIURPWKHJDVVXSSO\
V\VWHPE\FORVLQJWKHLQGLYLGXDOVKXWRIIYDOYH
:KHQFKHFNLQJIRUSURSHURSHUDWLRQRIWKHUHJXODWRU
WKHLQOHWSUHVVXUHPXVWEHDWOHDVW´JUHDWHUWKDQWKH
RSHUDWLQJPDQLIROGSUHVVXUHDVJLYHQRQUDWLQJODEHO
of product.
7HIORQ5HJLVWHUHGWUDGHPDUNRI'X3RQW
Gas
Inlet