RECORD OF CHANGES
R
EV # DATE DESCRIPTION ENTERED BY
C
3/15/05
- Updated ACTPERFORM
command to have 3 optional
Value parameters.
- Updated ACTPERFORM Action
Table to show how the 3
optional parameters are used.
- Updated 1
st
Example given for
ACTPERFORM
- Updated ATRN parameter to
specify time in 1/10 of a
second instead of milliseconds.
Example (105 = 10.5 seconds)
- Updated System Status Packet
Format for the EMSTAT
command. Swapped the
location of “Current Preset on
Program” and “Number of
Presets (n)”
R.
PELLICANO
D 8/26/05 - Added ACQUIRE command
- Added ICSAVE command
R. PELLICANO
E 9/15/05 - Added LEDMODE command R. PELLICANO
F 10/3/05 - Added RTE command R. PELLICANO
G 4/14/06 - Added Error Code 9 under
Protocol Specification
- Added LOCKOUT command
description
- Added LCDCAL command
description
R. PELLICANO
H 9/6/06 - Added description for Console
Port.
R. PELLICANO
www.barco.com
www.folsom.com
Page 3 of 23
Barco Media & Entertainment
11101 Trade Center Drive
Rancho Cordova, CA 95670
Command Syntax Specification
Ethernet Parameters
The following information describes how to connect to the Controller via Ethernet.
Communication Protocol Supported: TELNET
Default IP Address: 192.168.0.1
Communication Port: 3000
Example: telnet 192.168.0.1 3000
Note: Encore Controllers are configured by default to be a DHCP Server.
Console Port Parameters
The following information describes how to connect to the Controller via the Console
Port for serial control. Physical connection can be made with a straight 9-pin serial cable
to a computer.
Baud Rate: 115200
Data Bits: 8
Stop Bits: 1
Parity: None
Flow Control: None
Note: The above parameters are Factory Defaults. Refer to the MISCÆCONSL submenu
within the Controller for current settings or to change any of the above settings with the
exception of Flow Control.
www.barco.com
www.folsom.com
Page 4 of 23
Barco Media & Entertainment
11101 Trade Center Drive
Rancho Cordova, CA 95670
Protocol Specification
The following description is the DEFAULT Protocol Specification. Changes to this
specification are outlined in the PROTOCOL command below.
The Controller will respond with a 'KC>' prompt when the command processor is ready
for a command.
The command syntax is shown below
cmd arg1 arg2 … argn<CR>
cmd cmd is any valid Controller command, typically 2 to 6 alphabetic (non
numeric) characters.
arg arg1, arg2, …, argn are required or optional parameters depending
on the command used.
<CR> Carriage return (ASCII 13) terminates the command
A space (ASCII 32) must be inserted between the command and any arguments that
follow. A space must also be inserted between all arguments except for the last
argument in the chain.
A required argument is one that is enclosed in square ( [ ] ) brackets. An optional
argument is one that is enclosed in less-than-greater-than sign ( < > ) brackets. As an
example, we will consider the following command:
KEY [screenNum] [mode] <threshold>
With the notations used, we can easily tell that screenNum and mode are required
parameters while the threshold is optional.
All commands must be terminated with a carriage return (ASCII 13). The carriage
return will tell the command processor to begin execution of the command. From
hereafter, when we refer to a command, we will assume that a <CR> is always present
at the end of the command line even though it’s not explicitly written out.
If the command is not recognized as a valid command, a “!ERR_0<CR><LF>” is
returned. A new line will be generated and the prompt will indicate the system is ready
for a new command.
If the command is recognized and all of the command parameters are correct, the
system will execute the command and return the prompt once the command has
completed execution.
For an on-line list of available commands and its brief description, type HELP or ? at the
prompt.
www.barco.com
www.folsom.com
Page 5 of 23
Barco Media & Entertainment
11101 Trade Center Drive
Rancho Cordova, CA 95670
If a command is recognized as valid but the parameter list is somehow incorrect, an
“!ERR_#<CR><LF>” is returned to indicate an error. The # will have a numeric value
that specifies the type of error. After this line is sent out the prompt will be returned to
indicate the system is ready for a new command.
Error Codes
0 - Command Not Recognized
1 - Insufficient number of arguments supplied.
2 - At least one of the arguments is invalid (out-of-range value).
3 -
4 -
5 -
6 -
7 -
8 -
9 - Preset Recall Resource Conflict
10 - Requested Information Doesn’t Exist
(Ex. Recalling a Preset that hasn’t been learned yet.)
11 - Incomplete Binary Data Received
12 - Invalid binary data received
(Ex. Checksum incorrect, Data is not what is expected)
13 - Data Save Error (with regards for Flash Memory Writes)
www.barco.com
www.folsom.com
Page 6 of 23
Barco Media & Entertainment
11101 Trade Center Drive
Rancho Cordova, CA 95670
Binary Data Packet Specification
Note: Byte Alignment for all Binary Data Transfers is Little Endian.
SOH
DataSize (n)
DATA
Checksum
Byte 0 Byte 1
. . . . . . . .
Byte n-1
Field Name Length
in bytes
Description
SOH 1 Start-of-Header indicator. It has a fixed value
of 0x01.
DataSize
(n)
4 Specifies the number of bytes contained in
DATA.
DATA DataSize Contains the actual binary data. The first byte
(B[0]) is always the binary data type ID.
B[1:(n-1)] are data type specific.
Checksum 2 This is a simple byte-wise checksum of the
bytes contained in DATA.
www.barco.com
www.folsom.com
Page 7 of 23
Barco Media & Entertainment
11101 Trade Center Drive
Rancho Cordova, CA 95670
Remote Commands
ACQUIRE [dest] [layer] [mixer] <input connector>
This command will perform a Force
Acquire on the Destination, Layer and
Mixer selected.
ACTPERFORM [source] [type] <val1> <val2> <val3>
This command is sent out by the
Controller after a particular action has
taken place.
ATRN <transTime> Performs an auto transition to all
currently active destinations.
CLEARLAYER [layer] [mixer] This command will clear the layer
specified from Preview.
EMSTAT [status type] Returns status information specific for
the Events Manager Software
ICSAVE [dest] [layer] [mixer] This command will provide an Input
Configuration Save function for the
Destination, Layer and Mixer selected.
LCDCAL [op] This command will initiate the
Calibration procedure for the LCD
Touch screens.
LEDMODE [KeyType] [KeyID] [mode] This command will allow external
control of the LED for certain buttons
on the Controller.
LOCKOUT [op] <code> This command will enable or disable
the keyboard lockout feature.
PRESET [op] [user preset file #] Recall, Save or Delete Presets based
on operation selection.
PROTOCOL [type] For the device that issues this
command, modifications to the
Protocol Specification above will take
effect.
RTE [source] [dest] [layer] [mixer] This command will route a source for
a given Layer on a Destination.
TBAR [position] This command will perform a manual
transition.
www.barco.com
www.folsom.com
Page 8 of 23
Barco Media & Entertainment
11101 Trade Center Drive
Rancho Cordova, CA 95670
Controller Command List/Description
Acquire Input
ACQUIRE [dest] [layer] [mixer] <input connector>
Description:
This command will acquire an Input on the Destination, Layer and Mixer
specified. If input connector is not specified, then the current setting in the
Video Processor for that Layer/Mixer will be used.
Parameters:
[dest] – Specifies the Destination to use when performing this function.
[1 6] For the Encore Controller SC
[1 – 32] – For the Encore Controller LC
[layer] – Specifies the Layer on which to Acquire Video.
[0] Background Layer
[1 – 6] – Layers 1 to 6
[254] – DSK (Down Stream Key Layer)
[mixer] – Specifies the Mixer on which to Acquire Video.
[A] Mixer A
[B] Mixer B
Note: The [mixer] parameter is ignored when [layer] is 254.
<input connector> - Specifies the connector being used.
[0] HD-15
[1] BNC
[2] DVI
Note: If not specified the command will use the currently selected connector. This
parameter is ignored for BG and DSK layers .
Example:
ACQUIRE 1 1 A - would Force Acquire video on Destination 1, Layer
1A. The currently selected connector would be
assumed in this example.
ACQUIRE 1 2 B 0 - would Force Acquire video on Destination 1, Layer
2B on the HD-15 input connector.
www.barco.com
www.folsom.com
Page 9 of 23
Barco Media & Entertainment
11101 Trade Center Drive
Rancho Cordova, CA 95670
Auto Transition
ACTPERFORM [source] [type] <val1> <val2> <val3>
Description:
When a particular action has been performed by the controller, this
command will be sent out for use by external controlling software.
Parameters:
[source] – This is the source of the action (how it was initiated).
0 – Action performed by the Controller itself.
1 – Action performed as a result of an external command
received by the controller.
[type] – This is the type of action performed (see Action Table for more
details).
<val1>/<val2>/<val3> - The value(s) returned will be based on the type
of action performed (see Action Table for more details).
Action Table
ACTION TYPE Val(n)
RESERVED 0 N/A
Preset Recall 1
val1 - preset number recalled,
ranges from 1 to 900.
Auto Transition 2
val1 - Duration in tenths of a
second; e.g., 15 is 1.5
seconds.
CUT Transition 3 N/A
T-Bar Transition 4
val1 – current location of T-Bar
in tenths of a percent; ranges
from 0 – 1000; e.g., 750 is
75.0%
User Key
(See Appendix A for SC and
LC Tables)
5
val1 – Key type.
val2 – Key ID.
val3 – pressed/released status;
(1=Pressed , 0=Released)
Status Changes 6
val1 – status type;
(S=System, P=Legal Preset)
www.barco.com
www.folsom.com
Page 10 of 23
Barco Media & Entertainment
11101 Trade Center Drive
Rancho Cordova, CA 95670
Example:
ACTPERFORM 1 2 15 - would be sent for an Auto Transition (with a
transition rate of 1.5 seconds) performed as a
result of an external command received by the
controller.
ACTPERFORM 0 4 800 - would be sent as a result of the T-Bar movement
on the controller to a position equivalent to 80.0%.
ACTPERFORM 0 5 0 31 1 - would be sent as a result of a user key being
pressed (and still pressed). The key in this case is
the “Learn” key of the Preset key type.
www.barco.com
www.folsom.com
Page 11 of 23
Barco Media & Entertainment
11101 Trade Center Drive
Rancho Cordova, CA 95670
Auto Transition
ATRN <transTime>
Description:
Performs an Auto Transition on the currently active destinations. The
currently selected Effect type, rate, and edge width will be used to
transition preview to program.
Parameters:
<transTime> - optional; used to specify a transition time (duration of the
transition) in tenths of a second. Value ranges from 0 to 200. A 0 specify a
cut transition. Any non-zero value (within range) will override the transition
time in the controller. If this argument is not specified, the current
transition time known by the controller will be used.
Example:
ATRN 200 Transition Preview to Program on currently active destinations in 20
seconds.
ATRN 0 Transition Preview to Program immediately. This is a CUT.
ATRN Transition Preview to Program using the transition time set in the
controller.
Clear Layer
CLEARLAYER [layer] [mixer]
Description:
This command will clear the layer specified of the currently active
destination(s) from Preview.
Parameters:
[layer] – Specifics the Layer to be cleared.
[0] Background Layer
[1 – 6] – Layers 1 to 6
[254] – DSK (Down Stream Key Layer)
[255] ALL Layers (layers 1-6)
[mixer] – Specifies which mixer on the Layer to Clear.
[A] Mixer A
[B] Mixer B
Note: The [mixer] parameter is ignored when [layer] is 254 or 255.
Example:
CLEARLAYER 1 A – Layer 1A will be cleared from Preview
CLEARLAYER 0 A – Background A will be cleared from Preview.
CLEARLAYER 255 – All layers will be cleared from Preview.
www.barco.com
www.folsom.com
Page 12 of 23
Barco Media & Entertainment
11101 Trade Center Drive
Rancho Cordova, CA 95670
Events Manager Status
EMSTAT [status type]
Description:
Data returned is specific to the operation of the Events Manager Software
as described below (see Binary Data Packet Specification above for general
packet description):
Parameters:
[status type] – S will return System Status
P will return Legal Preset Status
Example:
EMSTAT S -- System Status Information is returned to the requestor.
EMSTAT P -- Legal Preset Status Information is returned to the requestor.
System Status Packet Format:
SOH DataSize (n) DATA Checksum
Controller
Model
Current
Preset on
Program
First
Defined
Preset Info
(n)
Defefined
Preset Info
Number of
Presets (n)
.....
Preset
Num
Preset
Name
B[0]
Data Format:
Field Name Length
in bytes
Description
B[0] 1 Binary Data Type ID = 14 (SYSTEM STAT ID NUM)
Controller
Model
1 “0” for Encore Controller SC
“1” for Encore Controller LC
Current
Preset on
Program
2 “0” if user modified, else this is the actual
Preset Number on Program.
Number of
Presets (n)
2 Number of DEFINED Presets currently in the
system. This is also the number of Preset
Packets that follow.
Defined
Preset Info
23 Contains the Preset Number and Name of a
defined Preset.
www.barco.com
www.folsom.com
Page 13 of 23
Barco Media & Entertainment
11101 Trade Center Drive
Rancho Cordova, CA 95670
Defined Preset Info Format:
Field Name Length
in bytes
Description
Preset
Number
2 Preset Number as stored in the Controller.
Preset
Name
21 Name of the Preset.
(20 Character Name + NULL)
Legal Preset Status Format:
SOH DataSize (n) DATA Checksum
First Legal
Preset Number
Second Legal
Preset Number
Last Legal
Preset Number
......
Number of
Legal Presets
B[0]
Data Format:
Field
Name
Length
in
bytes
Description
B[0] 1 Binary Data Type ID = 15 (LEGAL PRESET STAT ID NUM)
Number
of Legal
Presets
2 Specifies the number of Legal Preset that can be
recalled. This is how many Legal Preset Packets that
will follow.
Legal
Preset
Number
2 This is the Preset Number that can be legally recalled.
www.barco.com
www.folsom.com
Page 14 of 23
Barco Media & Entertainment
11101 Trade Center Drive
Rancho Cordova, CA 95670
Input Configuration SAVE
ICSAVE [dest] [layer] [mixer]
Description:
Use to save the currently selected input’s configuration file into a Video
Processor.
Parameters:
[dest] – Specifies the Destination to use when performing this function.
[1 6] For the Encore Controller SC
[1 – 32] – For the Encore Controller LC
[layer] – Specifies the Layer to use when Saving.
[0] Background Layer
[1 – 6] – Layers 1 to 6
[254] – DSK (Down Stream Key Layer)
[mixer] – Specifies which mixer to use when saving.
[A] Mixer A
[B] Mixer B
Note: The [mixer] parameter is ignored when [layer] is 254.
Example:
ICSAVE 1 1 A – Saves the currently selected video source on Destination
1 Layer 1A.
LCD Calibration
LCDCAL [op]
Description:
Use to initiate LCD Calibration procedure for the Touch Screen displays.
Parameters:
[op] – Specify the LCD to calibrate.
[1] – LCD Display on the Small Controller
Left LCD Display on the Large Controller
[2] – Right LCD Display on the Large Controller
Example:
LCDCAL 1 – Initiates the LCD Calibration for the touch screen on the Small
Controller or the left LCD on the Large Controller.
www.barco.com
www.folsom.com
Page 15 of 23
Barco Media & Entertainment
11101 Trade Center Drive
Rancho Cordova, CA 95670
LCDCAL 2 – Initiates the LCD Calibration for the touch screen on the right
LCD of the Large Controller
LED Mode
LEDMODE [KeyType] [KeyID] [mode]
Description:
Use to control the LED for the following Keys:
Timeline Trigger
Parameters:
[KeyType] – See Appendix A for the “Key Type” Value
[KeyID] – See Appendix A for the “Key ID” Value
[mode] – Specify the LED Mode.
[0] – LED OFF
[1] – LED ON
[2] – LED Blinking
Example:
LEDMODE 12 15 0 – Turns the Timeline Trigger button LED Off.
LEDMODE 12 15 1 – Turns the Timeline Trigger button LED On.
LEDMODE 12 15 2 – Makes the Timeline Trigger button LED Blink.
Note: All Key Types and Key IDs, if used, will produce an ERROR CODE response except the Timeline
Trigger Key Type and ID.
Lockout Mode
LOCKOUT [op] <code>
Description:
Use to enable or disable the Keyboard Lockout feature. When using this
command to disable the lockout, the command will require the code.
Parameters:
[op] – Specify the lockout mode.
[0] – Disable Lockout mode (code required)
[1] Enable Lockout mode
www.barco.com
www.folsom.com
Page 16 of 23
Barco Media & Entertainment
11101 Trade Center Drive
Rancho Cordova, CA 95670
<code> - Depending on the setting in the MISCÆLOCK sub-menu, the code
will be the DEFAULT, CUSTOM or MASTER code. (Default Code =
1111). The MASTER code is the three numbers that comprise the
current revision of software followed by 8. If the revision has a 0
in it, substitute a 1 in its place. If the revision has a 9 in it,
substitute an 8 in its place.
Example:
LOCKOUT 1 – Turns the lockout mode ON.
LOCKOUT 0 1111 – Turns the lockout mode OFF, provided the lockout code
setting in the MISCÆLOCK sub-menu is set to Default.
LOCKOUT 0 1128 – Turns the lockout mode OFF with the MASTER code if
the Controller is currently running revision 1.12
Preset Operation
PRESET [ op ] [user preset file #]
Description:
Executes the specified preset mode for the specified preset number.
Parameters:
[op] – R for Recall Preset, D for Delete Preset, S for Save Preset
[user preset file #] – 1 to 64 for Controller SC, 1 to 900 for Controller LC.
Example:
PRESET R 8 -- Recalls user preset 8 to preview.
PRESET D 1 -- Deletes user preset 1.
PRESET S 2 -- Save look on Preview to user Preset 2.
Protocol Specification
PROTOCOL [ type ]
Description:
For the device that executes this command, the default Protocol
Specification will change per the [type] selected. All other connected
devices will not be affected.
Parameters:
[type] – When type is 0:
This type will set the protocol to the default standard as
specified in the Protocol Specification above.
When type is 1:
This type will be reserved for Medialon Software. The changes
to the Protocol Specification are as follows:
www.barco.com
www.folsom.com
Page 17 of 23
Barco Media & Entertainment
11101 Trade Center Drive
Rancho Cordova, CA 95670
Once a recognized command is received, the controller will
send an ACK (0x06) in response. Once the command has
finished executing the prompt will be returned (“KC>”). If the
command is recognized but the parameters are wrong in some
way, the controller will send an ACK followed by an Error Code
before getting the prompt. If the command is not recognized,
the Controller will simply send an Error Code and then the
prompt.
Example:
PROTOCOL 0 -- Sets the protocol to the Default specification.
PROTOCOL 1 -- Sets the protocol for use with Medialon Software.
Route Source
RTE [source] [dest] [layer] [mixer]
Description:
Use to route a source on a Layer. If the Destination or Layer is not already
selected for modification, this command will automatically select the
Destination or Layer prior to performing the source route. If the
Destination is defined as an AUX, the “layer” and “mixer” parameters are
ignored.
Parameters:
[source] – Specifies the Source to use for the route.
[1 – 24] – For the Encore Controller SC
[1 – 64] – For the Encore Controller LC
[dest] – Specifies the Destination to use when performing this function.
[1 6] For the Encore Controller SC
[1 – 32] – For the Encore Controller LC
[layer] – Specifies the Layer to use when routing.
[1 – 6] – Layers 1 to 6
NOTE: [layer] is ignored if the Destination is defined as an AUX.
[mixer] – Specifies which mixer to use when routing.
[A] Mixer A
[B] Mixer B
NOTE: [mixer] is ignored if the Destination is defined as an AUX.
www.barco.com
www.folsom.com
Page 18 of 23
Barco Media & Entertainment
11101 Trade Center Drive
Rancho Cordova, CA 95670
Example:
RTE 16 2 1 A – Route Input Source 16 to Layer 1A on Destination 2.
RTE 3 4 – Route Input Source 3 to AUX Destination 4.
T-Bar Command
TBAR [position]
Description:
T-Bar command for manual transitions
Parameters:
[position] – TBar position in tenths of a percent; ranges from 0 to 1000 (0
to 100.0%), where 0=Transition Start, 1000=Transition End.
Example: T 500 : Will display 50.0% of Preview and Program on the Main Output
display.
www.barco.com
www.folsom.com
Page 19 of 23
Barco Media & Entertainment
11101 Trade Center Drive
Rancho Cordova, CA 95670
Appendix A – User Key ID Assignments
www.barco.com
www.folsom.com
Page 20 of 23
Barco Media & Entertainment
11101 Trade Center Drive
Rancho Cordova, CA 95670
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23

Barco Encore Controller LC User guide

Type
User guide
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI