  • Hello! I am an AI chatbot trained to assist you with the BRAVILOR BONAMAT B10 HW Owner's manual. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
Original document by manufacturer
© Copyright Bravilor Bonamat B.V.
MAN Descale B-Serie
(01-2019 / A)
1 / 5
9.
L
8.
G
7.
M
6.
K M NL
5.4.
3.2.1.
The descaling symbol ashes.
An audible signal sounds and the level
blocks ash.
Press key ‘L to conrm.Press key ‘G’ to start the descaling program.
Press key ‘M’.
PIN code: Press 1x K,
3x N(↑↑↑),
1x M (↓) and
1x N (↑).
Place the spray head above the container.
Place an empty lter pan (without lter
paper) on the container.
Dissolve 100 grams of Renegite in 0.75 litres
of hand-warm water (approx. 40 °C).
Stir the descaling solution, so that the agent
is solved well.
Read the safety instructions.
Descaling procedure B-serie
MAN Descale B-Serie.indd 1 16-1-2019 14:13:29
Original document by manufacturer
© Copyright Bravilor Bonamat B.V.
MAN Descale B-Serie
(01-2019 / A)
2 / 5
18.17.
L
16.
15.14.
2-5 min.
13.
12.
L
11.10.
Remove the plug from the lling opening for
the Renegite solution.
The machine is ready to add descaling
solution.
The container is empty.
Press key ‘L’.
Empty the container through the tap.The container is full.Caution: Hot water!
The water tank is boiled dry.
The water ows into the container.
The container is empty.
Press key ‘L’.
Empty the container through the tap.
MAN Descale B-Serie.indd 2 16-1-2019 14:13:31
Original document by manufacturer
© Copyright Bravilor Bonamat B.V.
MAN Descale B-Serie
(01-2019 / A)
3 / 5
27.26.
10-15 min.
25.
24.23.
2-5 min.
22.
21.
L
20.19.
Empty the container through the tap.The container is full.
Caution:
Hot water with Renegite solution!
The water tank is boiled dry.
The water ows into the container.
Wait for 5 minutes for the Renegite to work.Caution: Hot water!
The water tank is boiled dry to let the
Renegite solution ow through the
circulation element.
If the Renegite solution has been added,
press key ‘L’.
Place the funnel in the lling opening.
Carefully pour the Renegite solution through
the funnel.
MAN Descale B-Serie.indd 3 16-1-2019 14:13:33
Original document by manufacturer
© Copyright Bravilor Bonamat B.V.
MAN Descale B-Serie
(01-2019 / A)
4 / 5
36.
10-15 min.
35.34.
L
33.32.31.
10-15 min.
30.29.
L
28.
The container is full.Caution: Hot water!
Last rinsing.
The container is relled.
The container is empty.
Press key ‘L’.
Empty the container through the tap.The container is full.
Caution: Hot water!
First rinsing.
The container is relled.
The container is empty.
Press key ‘L’.
MAN Descale B-Serie.indd 4 16-1-2019 14:13:34
Original document by manufacturer
© Copyright Bravilor Bonamat B.V.
MAN Descale B-Serie
(01-2019 / A)
5 / 5
41.40.
39.
L
38.37.
Note:
Reference model B5 L/R
Empty the container through the tap.
The container is empty.
Press key ‘L’.
The display shows the counter reading.
The counter reading is automatically reset
to zero.
The descaling program has been closed.
The display shows the user menu.