Vantage Technologies GB/GD & SB/SD Series Receptacles Installation guide

Type
Installation guide

Vantage Technologies GB/GD & SB/SD Series Receptacles are a versatile solution for connecting and protecting electrical circuits in a wide range of industrial and commercial applications. Crafted with durability and reliability in mind, these receptacles feature robust construction and are built to withstand harsh environmental conditions. The receptacles are designed to ensure a secure and environmentally sealed connection, safeguarding against moisture or other conductive materials that could lead to electrical failures.

The receptacles offer easy assembly and maintenance, making them a convenient choice for various electrical projects. They come equipped with non-conductive lubricant to enhance performance and extend the life of the connection. Additionally, the presence of chain rings in the design caters to ATEX requirements, ensuring compliance with specific industry standards.

Vantage Technologies GB/GD & SB/SD Series Receptacles are a versatile solution for connecting and protecting electrical circuits in a wide range of industrial and commercial applications. Crafted with durability and reliability in mind, these receptacles feature robust construction and are built to withstand harsh environmental conditions. The receptacles are designed to ensure a secure and environmentally sealed connection, safeguarding against moisture or other conductive materials that could lead to electrical failures.

The receptacles offer easy assembly and maintenance, making them a convenient choice for various electrical projects. They come equipped with non-conductive lubricant to enhance performance and extend the life of the connection. Additionally, the presence of chain rings in the design caters to ATEX requirements, ensuring compliance with specific industry standards.

M-602-EC (03/17) Page 1
EN/ES
It is important that a properly sized grommet has been selected to obtain a good environmental seal. Failure to
provide proper environmental sealing can permit moisture or other conductive material to enter the connector
resulting in possible electrical failure.
Please use the table on Page 2 to confirm that the grommet ordered fits your cable properly. If not, please
contact us for an immediate grommet replacement.
Dimension A = Max. Cable Diameter
Dimension B varies with Shell Size
Reference Table on Page 2.
ØA
13
16
ØB
Vantage Technology ®
GB/GD and SB/SD Series
Attachment Receptacle/Cable Connector
Termination Instructions
CAUTION: Before installing, make sure you are in compliance with area classifications, failure to do so may result in bodily injury,
death and property damage. Do not attempt installation until you are familiar with the following procedures. Installation must comply
with the applicable Electrical Code(s). Make sure that the supply circuit is de-energized before starting installation or maintenance.
Verify that the installation is grounded. Failure to properly ground the product will create electrical shock hazards, which can cause
serious injury or death.
Important: Please read these instructions carefully before installing or maintaining this equipment. Safe electrical practices should
be followed at all times and this data should be used as a guide only.
GROMMET SELECTION
CAUTION!
¡PRECAUCIÓN!
IDENTIFICATION OF PRINCIPAL PARTS
RECEPTACLE
COVER RECPTACLE
SHELL INSERT
CLAMP NUT
CABLE
HOUSING WASHER COVER
CHAIN RING
CABLE
CLAMP
GROMMET
INSERT ASSEMBLY
4 EACH NO. 10-32 1/2"
FLAT HEAD SCREW
Note to Zonal Users:
This product complies with the EN 60079-0:2004 requirement
that
,
parts necessary to achieve a specific type of protection or
used to prevent access to uninsulated live parts shall be capable
of being released or removed only with the aid of a tool.
SECURE RECEPTACLE COVER WITH SCREW WHEN PLUG
IS REMOVED FROM RECEPTACLE.
ATEX REQUIRED PART
ATEX COMPONENTE REQUERIDO
LONG OR SHORT INSERT
CLAMP NUT MAY BE PROVIDED
LUBRICATE WITH NON
CONDUCTIVE LUBRICANT
LUBRICATE WITH NON
CONDUCTIVE LUBRICANT
M-602-EC (03/17) Page 2
EN/ES
Table 1. Grommet Sizing Table
Shell
Size
Dim. B
(Inches)
Cable Diameter (Inches)
Cable Diameter
Grommet Part Number
MIN.
MAX., Dim. A
16 1 23/32
.250
.375
.375
.500
VT-6316-6C
VT-6316-8C
.500
.625
.625
.750
VT-6316-10C
VT-6316-12C
.750
.875
.875
1.000
VT-6316-14C
VT-6316-16C
1.000
1.125
1.125
1.250
VT-6316-18C
VT-6316-20C
1.250
1.375
1.375
1.437
VT-6316-22C
VT-6316-23C
20 2 7/32
.500
.625
.625
.750
VT-6320-10C
VT-6320-12C
.750
.875
.875
1.000
VT-6320-14C
VT-6320-16C
1.000
1.125
1.125
1.250
VT-6320-18C
VT-6320-20C
1.250
1.375
1.375
1.500
VT-6320-22C
VT-6320-24C
1.500
1.625
1.625
1.750
VT-6320-26C
VT-6320-28C
1.750
1.875
1.875
1.937
VT-6320-30C
VT-6320-31C
24 2 23/32
1.875
1.000
VT-6324-16C
1.000
1.125
1.125
1.250
VT-6324-18C
VT-6324-20C
1.250
1.375
1.375
1.500
VT-6324-22C
VT-6324-24C
1.500
1.625
1.625
1.750
VT-6324-26C
VT-6324-28C
1.750
1.875
1.875
2.000
VT-6324-30C
VT-6324-32C
2.000
2.125
2.125
2.250
VT-6324-34C
VT-6324-36C
2.250
2.375
2.375
2.437
VT-6324-38C
VT-6324-39C
28 3 5/32
1.375
1.500
VT-6328-24C
1.500
1.625
1.625
1.750
VT-6328-26C
VT-6328-28C
1.750
1.875
1.875
2.000
VT-6328-30C
VT-6328-32C
2.000
2.125
2.125
2.250
VT-6328-34C
VT-6328-36C
2.250
2.375
2.375
2.500
VT-6328-38C
VT-6328-40C
2.500
2.625
2.625
2.750
VT-6328-42C
VT-6328-44C
2.750
2.875
VT-6328-46C
*The cable diameter code is used to define the grommet size in the connector’s catalog part number. For
example, connector GD-B1516-51SL-18 comes with a size “18” grommet, to be used with a cable diameter
range of 1.00 1.125 inches.
GROMMET SELECTION (cont’d)
M-602-EC (03/17) Page 3
EN/ES
PASS FREE END OF CABLE
THRU PARTS AS SHOWN
INSERT
CLAMP NUT CABLE
ADAPTER GROMMET
WASHER CABLE
CLAMP
COVER
CHAIN RING
LUBRICATE WITH NON
CONDUCTIVE LUBRICANT
LUBRICATE WITH NON
CONDUCTIVE LUBRICANT
A
3"
Table 2. Jacket Stripping
Rating
Dimension “A” (Inches)
30 AMP 3/4
60 AMP 1 1/4
100 AMP 1 3/8
200 AMP 1 1/2
Step 1 ASSEMBLY OF ADAPTER COMPONENTS
1. Select one end of the cable for termination. Select cable end with conductor pattern best suited
to contact pattern of connector.
2. Pass the cable thru the parts as shown.
3. It is important that a properly sized grommet has been selected to obtain a good environmental
seal. The cable should be free of grooves or ridges where the cable grommet seats on the cable.
Step 2 CABLE JACKET & WIRE STRIPPING
Strip cable jacket as shown. Select dimension “A” from Table A to correspond with connector rating and score
insulation. To help prevent stranded wire from fraying, do not remove insulation slug until ready to execute
Step 3.
M-602-EC (03/17) Page 4
EN/ES
Step 3 TERMINATING CONDUCTORS
Remove the insert assembly from the receptacle shell. Do not disassemble the contacts from
the rear rigid insulation and the grey center insulation. Insert all stripped leads into assigned contact
termination wells. Close pressure pad assembly on stripped leads per Table 3.
BE SURE THAT ALL
BACKSHELL ADAPTER
COMPONENTS ARE ON
CABLE AND IN THE
CORRECT ORDER PRIOR
TO INSERTING CONTACTS.
Table 3. WIRE TERMINATION
TORQUE VALUES
RATING
(AMPS)
TORQUE
(IN-LB)
10 15
30 26
60 26
100 70
200 120
M-602-EC (03/17) Page 5
EN/ES
Step 4 ASSEMBLE INSERT INTO RECEPTACLE SHELL
Align the insert keyways with the receptacle shell key, and seat within receptacle shell as shown. The
insert assembly must seat fully to shoulder within the shell so that the interior shell threads can be
engaged by the insert clamp nut.
Step 6
CLOSING CABLE HOUSING
Thread cable housing onto back of receptacle shell until tight and gasket creates seal. Back off cable
housing until four set screw holes line up. Tighten set screws.
5/16
INSULATION KEYWAYS
FRONT RIGID
INSULATION
FRONT RIGID
INSULATION
RECEPTACLE
SHELL KEY
WHEN FULLY LOADED, THE REAR
RIGID INSULATOR WILL EXTEND
APPROXIMATELY 5/16" BEYOND
THE RECEPTACLE SHELL.
FEMALE INSERT ASSEMBLY
MALE INSERT ASSEMBLY
REAR RIGID INSULATION
REAR RIGID INSULATION
M-602-EC (03/17) Page 6
EN/ES
7
8LONG CLAMP NUT
WILL BOTTOM OUT
WITH 7/8" EXPOSED.
FOUR (4) SET SCREWS
Step 5 CLOSING INSULATION CLAMP NUT
Install the insulation clamp nut. Use suitable spanner or strap wrench to tighten. Clamp nut must
bottom out on the insert assembly shoulder and project from the shell 7/8" as shown.
Step 6. CLOSING CABLE HOUSING
Thread cable housing onto back of receptacle shell until tight and gasket creates seal. Back off cable
housing until four set screw holes line up. Tighten set screws.
WRENCH TOOL
*Short Clamp Nut will not be exposed.
Use provided wrench tool to fully tighten
M-602-EC (03/17) Page 7
EN/ES
Step 7 FINAL ASSEMBLY
Install cable housing, grommet, washer, and cable clamp nut. Tighten clamp nut and clamp screws.
IMPORTANT: When not in use, disconnect supply circuit and thread cover onto receptacle.
IMPORTANTE: Cuando no en uso, desconecte el circuito y vuelve a poner la cubierta del receptáculo.
M-602-EC (03/17) Page 8
EN/ES
®
CABLE ASSEMBLIES
Factory Assembly of Connectors and Cable
If your connector(s) arrived pre-assembled to cable and/or other third-party
components, consider the following:
1. Follow the instructions and recommended maintenance practices for
the attachment plug and/or receptacle.
2. Review the useage instructions on the connector nameplate.
3. For IECEx and ATEX applications, in potentially explosive atmospheres,
the unterminated end of an integrally mounted cable shall be terminated
in a suitable enclosure, e.g. in type of protection flameproof
enclosures "Ex d" or increased safety "Ex e".
Voice 303-761-2121
FAX 281-445-7404
E-mail support@VantageXP.com
Web Site www.VantageXP.com
4140 World Houston Pkwy, Ste 130
Houston, Texas 77032, USA
Notes
1. Periodically and when conditions require, lubricate coupling threads with silicone oil (part number VT-
9400-21D), furnished with connector.
2. Periodically inspect receptacle to insure that all thread engagements are secure and that the grommet
continues to provide an environmental seal.
3. Periodically inspect receptacle for excessive wear. Consult Vantage with any questions regarding
repair or replacement.
Note: Electrical installation shall be in compliance with the National Electric Code
(NEC), EN/IEC60079-14, and/or any other presiding local or national electrical codes.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8

Vantage Technologies GB/GD & SB/SD Series Receptacles Installation guide

Type
Installation guide

Vantage Technologies GB/GD & SB/SD Series Receptacles are a versatile solution for connecting and protecting electrical circuits in a wide range of industrial and commercial applications. Crafted with durability and reliability in mind, these receptacles feature robust construction and are built to withstand harsh environmental conditions. The receptacles are designed to ensure a secure and environmentally sealed connection, safeguarding against moisture or other conductive materials that could lead to electrical failures.

The receptacles offer easy assembly and maintenance, making them a convenient choice for various electrical projects. They come equipped with non-conductive lubricant to enhance performance and extend the life of the connection. Additionally, the presence of chain rings in the design caters to ATEX requirements, ensuring compliance with specific industry standards.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI