Town & Country Fireplaces TC36 / TC36 Arch Installation guide

Category
Fireplaces
Type
Installation guide

This manual is also suitable for

SERIAL #
290823-44 TC36.CODE 100004579
MODEL: TC36.OD
SERIES C w/ Screen
MODULAR DIRECT VENT
FIREPLACE
WARNING: If the information in these
instructions is not followed exactly, a fire
or explosion may result causing property
damage, personal injury or death.
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
Installation and service must be performed
by a qualified installer, service agency or
the gas supplier.
TC36 OUTDOOR GAS
FIREPLACE INSTALLATION AND
OPERATING INSTRUCTIONS
WARNING:
For Outdoor Use Only
Visit www.townandcountryfireplaces.net for the most recent version of this manual
DANGER: If you smell gas:
1. Shut off gas to the appliance
2. Extinguish any open flame.
3. If odor continues, keep away from the
appliance and immediately call your gas
supplier or fire department.
WARNING: Do not store or use gasoline or
other flammable vapors and liquids in the
vicinity of this or any other appliance. An
LP-cylinder not conected for use shall not
be stored
WARNING: Improper installation, adjusment,
alteration, service or maintenance can cause
injury or property damage. Read the installa-
tion, operating and maintenance instructions
thoroughly before installing or servicing this
equipment.
CARBON MONOXIDE HAZARD
This appliance can produce carbon
monoxide which has no odor.
using it in an enclosed space can
kill you.
Never use this appliance in an
enclosed space such as a camper,
tent, car or home.
Caution ............................................................ 3
Safety .............................................................. 3
Important Note for the Commonwealth
of Massachusetts ............................................ 4
This Fireplace Is Intended For
Outdoor Use Only! ........................................... 5
Propane Conversion ........................................ 6
Fireplace Dimensions ...................................... 7
Minimum Clearances to Combustible Material 7
Mantel clearance chart ......................................7
Installation Requirements ................................ 8
Window Frame Removal ................................. 8
Top Standoffs .................................................. 9
Locating The Fireplace .................................... 9
Framing and Finishing ................................... 10
TC36 Steel Stud Framing Kit ......................... 13
Adjustable Lintel ............................................ 15
Hearth Extension ........................................... 16
Honeywell Control Valve Plumbing
and Electrical ................................................. 17
Gas Supply .................................................... 18
Gas Pressure Check ...................................... 18
Venting ........................................................... 19
Wall Termination Venting ............................... 19
Vent System Components ...............................20
Wall Termination Venting Chart ..................... 22
Roof Termination Venting Chart .................... 23
Ceiling Opening: ..............................................24
Ceiling Firestop: ...............................................24
Vent Pipe: .........................................................24
Roof Support Bracket: .....................................24
Roof Vent Terminal: ..........................................25
Vent Terminal Clearance ................................ 26
Vent Terminal Minimum Clearances .............. 26
Roof Pitch Table .............................................26
Vent Pipe Sealant .......................................... 27
Insulated Collar Shield (Included) .................. 27
Vent Restrictor Adjustment ........................... 28
Firebox Panels Installation ............................ 29
Lighting Instructions ...................................... 31
First Fire ......................................................... 31
Maintenance .................................................. 32
Glass Panel: .....................................................32
Annual Inspection: ...........................................32
Periodically: .....................................................32
Replacement Parts ........................................ 33
Replacement Parts – Honeywell
Control System .............................................. 34
Wiring Diagram .............................................. 35
Wall Termination Kit ....................................... 36
Roof Termination Kit ...................................... 36
Wall Shield ..................................................... 36
Ceiling Firestop Thimble .................................. 36
Vent Pipe Dimensions ................................... 37
Vent Offset Chart ........................................... 38
Rating Label Location ................................... 39
2TC36.CODE_290823-44
100004579
Table of Contents
WARNING: This product
can expose you to chemicals
including ceramic bers,
which are known to the State
of California to cause cancer, and carbon
monoxide, which is known to the State of
California to cause birth defects or other
reproductive harm.
For more information go to
www.P65Warnings.ca.gov.
This warning is applicable to all
Pacific Energy Fireplace Products
3
TC36.CODE_290823-44 100004579
FOR YOUR SAFETY - Do not install or operate your Town & Country replace without rst reading and
understanding this manual. Any installation or operational deviation from the following instructions voids
the Town & Country Fireplaces Warranty and may prove hazardous.
This appliance and its individual shut off valve must be disconnected from gas supply piping system during
any pressure testing of that system at test pressures in excess of 1/2 psig (3.5 kPa).
This appliance must be isolated from the gas supply piping system by closing its individual manual shut off
valve during any pressure testing of the gas supply piping system at test pressures equal to or less than
1/2 psig (3.5 kPa).
Note: When lit for the rst time, the appliance will emit a slight odour
for a couple of hours. This is due to the curing of paints, sealants
and lubricants used in the manufacturing process. This condition is
temporary. Open doors and windows to ventilate area. Smoke and
fumes caused by the curing process may cause discomfort to some
individuals.
Do not use the replace if any part has been under water. Immediately
call a qualied service technician to inspect the replace and to replace
any part of the control system and any gas control which has been
under water.
Due to high temperatures, this gas appliance should be located out of trafc and away from furniture and
draperies.
Children and adults should be alerted to the hazards of high surface temperatures and should stay away to avoid
burns or clothing ignition.
Young children should be carefully supervised when they are in the same
room as the appliance.
Clothing or other ammable material should not be placed on or near the
appliance.
Any grill, panel or door removed for servicing the unit must be replaced
prior to operating. Failure to do so may create a hazardous condition.
Installation and repair should be done by a qualied service person. The
appliance should be inspected before use and at least annually by a
professional service person. More frequent cleaning may be required due
to excessive lint from carpeting, bedding material, etc. It is imperative that
control compartments, burners and circulating air passageways of the
appliance be kept clean.
It is our policy that no responsibility is assumed by the Company or by
any of its employees or representatives for any damages caused by an
inoperable, inadequate, or unsafe condition which is the result, either
directly or indirectly, of any improper operation or installation procedures.
This appliance must not be connected to a chimney ue serving a separate
solid fuel burning appliance.
Caution
Safety
We recommend that our gas hearth
products be installed and serviced
by professionals who are certied
in the United States by the National
Fireplace Institute® (NFI) as NFI Gas
Specialists
WARNING: Solid fuels
should not be burned in this
appliance.
Warning: This appliance is
only for use with the type of
gas indicated on the rat-
ing plate. This appliance is
not convertible for use with
other gases, unless a certi-
fied kit is used.
HOT GLASS WILL CAUSE
BURNS.
DO NOT TOUCH GLASS UNTIL
COOLED.
NEVER ALLOW CHILDREN TO
TOUCH GLASS.
!
DANGER
From Massachusetts Rules and Regulations 248 CMR 5.08:
(a)For all side wall horizontally vented gas fuelled equipment installed in every dwelling, building or structure used in whole or in part
for residential purposes, including those owned or operated by the Commonwealth and where the side wall exhaust vent termination
is less than seven (7) feet above nished grade in the area of the venting, including but not limited to decks and porches, the following
requirements shall be satised.
1. INSTALLATION OF CARBON MONOXIDE DETECTORS. At the time of installation of the side wall horizontal vented gas fuelled
equipment, the installing plumber or gas tter shall observe that a hard wired carbon monoxide detector with an alarm and
battery back-up is installed on the oor level where the gas equipment is to be installed, in addition, the installing plumber or
gas tter shall observe that a battery operated or hard-wired carbon monoxide detector with an alarm is installed on each
additional level of the dwelling, building or structure served by the side wall horizontal vented gas fuelled equipment. It shall
be the responsibility of the property owner to secure the services of qualied licensed professionals for the installation of
hard-wired carbon monoxide detectors.
a. In the event that the side wall horizontally vented gas fuelled equipment is installed in a crawl space or an attic, the hard-wired
carbon monoxide detector with alarm and battery back-up may be installed on the next adjacent oor level.
b. In the event that the requirements of this subdivision cannot be met at the time of completion of installation, the owner shall
have a period of thirty (30) days to comply with the above requirements; provided, however, that during said thirty (30) day
period, a battery operated carbon monoxide detector with an alarm shall be installed.
2. APPROVED CARBON MONOXIDE DETECTORS. Each carbon monoxide detector as required in accordance with the above
provisions shall comply with NFPA 720 and be ANSI/UL 2034 listed as IAS certied.
3. SIGNAGE. A metal or plastic identication plate shall be permanently mounted to the exterior of the building at a minimum
height of eight (8) feet above grade directly in line with the exhaust vent terminal for the horizontally vented gas fuelled
heating appliance or equipment. The sign shall read, in print size no less than one-half (1/2) inch in size, “GAS VENT DIRECTLY
BELOW. KEEP CLEAR OF ALL OBSTRUCTIONS”.
4. INSPECTION. The state or local gas inspector of the side wall horizontally vented gas fuelled equipment shall not approve the
installation unless, upon inspection, the inspector observes carbon monoxide detectors and signage installed in accordance
with the provisions of 248 CMR 5.089(2)(a) 1 through 4.
(b) EXEMPTIONS. The following equipment is exempt from 248 CMR 5.089(2)(a) 1 through 4.
1. The equipment listed in Chapter 10 entitled “Equipment Not Required To Be Vented” in the most current edition of NFPA 54
as adopted by the Board; and
2. Product Approved side wall horizontal vented gas fuelled equipment installed in a room or structure separate from the
dwelling, building or structure used in whole or in part for residential purposes.
(c) MANUFACTURER REQUIREMENTS – GAS EQUIPMENT VENTING SYSTEM PROVIDED. When the manufacturer of Product
Approved side wall horizontally vented gas equipment provides a venting system design or venting system components with the
equipment, the instructions provided by the manufacturer for installation of the equipment and the venting system shall include:
1. Detailed instructions for the installation of the venting system design or the venting system components; and
2. A complete parts list for the venting system design or venting system.
(d) MANUFACTURER REQUIREMENTS – GAS EQUIPMENT VENTING SYSTEM NOT PROVIDED. When the manufacturer of a
Product Approved side wall horizontally vented gas fuelled equipment does not provide the parts for venting the fuel gases, but
identies “special venting systems”, the following requirements shall be satised by the manufacturer.
1. The referenced “special venting system” instructions shall be included with the appliance or equipment installation
instructions; and
2. The “special venting systems” shall be Product Approved by the Board, and the instructions for that system shall include a
parts list and detailed installation instructions.
(e) A copy of all installation instructions for all Product Approved side wall horizontally vented gas fuelled equipment, all venting
instructions, all parts lists for venting instructions, and/or all venting design instructions shall remain with the appliance or
equipment at the completion of the installation.
Important Note for the Commonwealth of Massachusetts
4TC36.CODE_290823-44
100004579
The fireplace must be located inside of a weatherproof enclosure.
Flashing must be installed around the fireplace opening in accordance
with local building codes in order to prevent moisture from entering the
enclosure.
A drip pan (not supplied with the unit) must be installed under the fireplace
and be provided with a means of draining.
Care must be taken to select materials and building practices which will
protect the enclosure and fireplace from exposure to moisture.
Not for use with a power vent.
This Fireplace Is Intended For Outdoor Use Only!
5
TC36.CODE_290823-44 100004579
Propane Conversion
Note: This fireplace comes with a
preinstalled Honeywell pilot. When installing
the burner assembly, remove the pilot that
came attached to the burner and discard.
DO NOT USE ANY OTHER PILOT WITH
YOUR OUTDOOR UNIT OTHER THAN THE
HONEYWELL PILOT THAT CAME INSTALLED
IN THE FIREPLACE.
1. Remove the compression tting from the
bottom of the orice housing and gently tap
the pilot in your hand. The natural gas orice
should fall out (Figure 1).
2. Insert the propane orice that came in
your instruction pack as shown into the
orice housing and reattach the pilot to the
compression ttng and pilot tube (Figure 2
and Figure 3).
3. Using the valve conversion kit that came in
the instruction pack, convert the valve to
propane following the instructions provided
with the kit (Figure 4).
Orice housing
Compression tting
Figure 1: Removing NG orice.
Orice housing
Orice
Compression
tting
Figure 2: Orice insert.
Orice
Figure 3: Orice.
Figure 4: Valve conversion kit.
6TC36.CODE_290823-44
100004579
50”
26”
26 3/4”
37 1/2”
47 7/8
32 1/2”
11 11/16”
38 1/2”
14”
36 1/8”
26 3/4”
Steel stud framing kit is wider than unit
A
B
C
D
E
F
Steel Frame
Non-combustible
nish material
May use combustible
facing material in this
area
Stand offs
= Non-combustible zone. Do not install
any combustible material, electrical wiring
or gas plumbing in this area.
Top of lintel bar
Combustible framing
and nish wall above
standoffs
Fireplace front
Figure 5: Mantel clearances.
Mantel clearance
chart
* Mantel clearance
A 9”
B 6”
C 3”
** Mantel depth
D 12”
E 6 3/4”
F 1 1/2”
Minimum Clearances:
Side standoffs ...............................0 in. (0 mm)
Back standoffs ..............................0 in. (0 mm)
Top standoffs .................................0 in. (0 mm)
Bottom of appliance ......................0 in. (0 mm)
Adjacent side wall .........................4 in. (102 mm)
Ceiling to appliance .....................24 in. (610 mm)
*Mantel to appliance ..................................... See Figure #2
**Maximum Mantel extension ....................... See Figure #2
Mantel support ..............................4 in. (102 mm)
Vertical vent pipe ..................1 3/4" in. (45 mm)
Horizontal Vent pipe ..............1 3/4" in. (45 mm)
(Top, sides and bottom)
24”
32 1/8”
4”
MANTEL
ADJACENT WALL
OR MANTEL
SUPPORT
CEILING
UNIT MAY BE RECESSED UP TO 4 1/2” WITH
NON-COMBUSTIBLE MASONRY TYPE
MATERIAL
**
*
Figure 6: TC 36CODE Mantle.
7
TC36.CODE_290823-44 100004579
Fireplace Dimensions
Minimum Clearances to Combustible Material
Figure 7: Accessing handle.
HANDLE
Figure 8: Handle.
The Town & Country Fireplace installation and venting must conform to the current CAN/CGA-B149 installation
code (in Canada) or the current National Fuel Gas Code, ANSI Z223.1 (in the USA), and approved per local codes.
Only qualified (licensed or trained) personnel should install this product.
In the state of Massachusetts, only a licensed Plumber and Gas Fitter may install this product.
Warning: Turn off the replace, and allow ample time for the unit to cool before proceeding.
Caution: The ceramic glass is very fragile, and should be handled with care.
The window frame is held in place by two spring-loaded latches that are operated by a one-piece latch
handle.
1. Remove the TC Finishing Touch Trim Kit from the window frame. (If installed)
2. Using a screwdriver or other similar object, push against the notch in the top of the latch and grab the
bottom of the latch handle as it protrudes. Lift handle until latch hook disengages. Repeat for other side
while holding glass so it does not tip out.
3. Tilt the top of the window frame out to clear the top edge of the unit. Grasp the sides of the frame and lift
up and out to disengage from its bottom track.
4. Place the window frame in a safe place to avoid damage.
5. Re-assemble in reverse order. Latch handle should snap into place and be ush with window frame when
engaged correctly.
6. Reinstall Trim Kit if required.
TIP:
To ensure glass is properly latched, grasp the top left and right sides of the
glass frame, under moderate pressure it should pull forward and return to
original position evenly on both sides.
8TC36.CODE_290823-44
100004579
Installation Requirements
Window Frame Removal
TOP STANDOFFS
Figure 9: Standoffs.
Figure 10: Location examples.
The top standoffs are shipped
loose inside the replace and must
be installed on top of the replace
as shown in Figure 9. Do this
once the replace is on site and in
position.
In planning the installation for the replace, it is necessary to determine where the unit is to be installed,
location of vent system and where gas supply piping may be plumbed. Various installations are possible, such
as, into an existing wall, a corner, a built-in wall or a wall projection (Figure 10). Due to high temperatures, do
not locate this replace in areas of high trafc or near furniture or draperies.
The minimum clearances from the fireplace to combustible surfaces must be adhered to and are
shown in Figure 5 and Figure 6.
EXAMPLES OF COMMON LOCATIONS
SEE FIG #15 FOR DIMENSIONS
9
TC36.CODE_290823-44 100004579
Locating The Fireplace
Top Standoffs
Note: The fireplace should be in place and venting installed before framing in or building an enclosure
around the unit.
The Town & Country replace must be framed in as described below or totally enclosed with non-combustible
material, such as facing brick.
Determine the total thickness of facing material to be used. A thickness of 3/4" will allow the nishing surface
to be ush with the front of the unit. If preferred, additional masonry type non-combustible material can be
installed above and to the sides up to 6 inches proud of the appliance. The nishing material must not inter-
fere with glass frame access.
A Steel Stud Framing Kit is supplied with the replace and must be used unless the replace is totally
enclosed with non-combustible material. Assemble the framing kit as per the instructions on page 13 and
page 15 of this manual. Attach the steel frame to the replace once the replace is in its nal position.
Secure the steel frame to the framing brackets on each side of the unit. Ensure that the studs are set back far
enough to allow for thickness of nishing surface.
The sides, back and top of the replace can be framed in up to the steel studs and the replace standoffs
using conventional lumber. Consult local building codes for specic requirements.
Due to high temperatures, non-combustible backer board, such as cement board or its equivalent, must be
used to sheet in the front of the replace, extending 12" above and 5 9/16" to the side of the framing edge
bars (Figure 13). Standard sheet rock (dry wall) may be used beyond this.
If the backer board is not to be nished with other non-combustible material such as tiles, it is recommended
that the instructions in Figure 14 be followed closely.
Fabricate and install appropriate ashing to local building code.
Note: Installing unit without flashing installed will void the warranty
Note: Provide proper drainage to divert water from underneath the unit
Chase Insulation: When installing this replace against a non-insulated exterior wall or chase, it is
recommended that the outer walls be insulated to same degree as other exterior walls. Do not place replace
directly against the insulation. Cover the insulation and plastic vapour barrier with a solid surface, such as dry
wall (sheet rock). Consult local codes. Do not insulate or use plastic vapour barrier within the framing kit.
CAUTION: See Figure 14 before proceeding.
10 TC36.CODE_290823-44
100004579
Framing and Finishing
50 1/4
48 1/8”
Steel framing kit dimensions
(supplied with fireplace)
All other framing can be done with conventional
lumber.
It is highly recommended that a full header be
installed above the metal framing kit.
Non-combustible zone.
Do not install any
combustible material,
electrical wiring,
insulation, plastic
vapor barrier or gas
plumbing within the
steel stud framing.
Figure 11: Framing kit dimensions.
22 1/2"
50 1/2" 48 3/8"
50 1/2"
NOTE: FIREPLACE SHOULD BE IN ITS FINAL LOCATION BEFORE FRAMING
RANGE
25"
to
26 1/2"
27"
RANGE
1/2" - 2"
12 3/4"
FRAMING
LINTEL
50 1/2"
RANGE
61 3/4”
to
63 7/8"
31 7/8"
RANGE
61 3/4”
to
63 7/8"
RANGE
87 3/8”
to
90 3/8"
Figure 12: TC 36 OD w_screen, Minimum combustible framing dimensions.
11
TC36.CODE_290823-44 100004579
If nishing the wall above the unit with paint,
the framing kit shipped with the unit should
be discarded. Use full sheets of calcium
silicate board or equivalent and full length
metal studs to nish and frame around the
unit.
Calcium silicate board is a high grade material
with cement, quartz and natural minerals
as the main raw materials. (Note: Calcium
Silicate is 1/2” thick)
CAUTION: Calcium Silicate board can be
damaged if dropped or struck. Handle with
care. Inspect board prior to installation and do
not use if cracked.
NOTE: It is recommended to pre-drill
mounting holes in the board prior to securing
to the framing. This will prevent the board
from cracking.
Non-combustible board detail
NON-COMBUSTIBLE
MATERIALS MUST EXTEND
12" ABOVE AND 5 9/16" TO
THE SIDES OF THE FRAMING
EDGES.
NON-COMBUSTIBLE
BOARD 12”
5 9/16”
Figure 13: Non combustible board dimensions.
NON-COMBUSTIBLE
RECESSED
INSTALLATION DETAIL
Recessed
Installation
4 1/2"
MAXIMUM
FACING DEPTH
NON-COMBUSTIBLE
BOARD
NON-COMBUSTIBLE
MATERIAL
STEEL STUD FRAME
FIREPLACE FRONT GLASS
Figure 14: Recessed installation detail.
Non-combustible
board
Figure 15: Non combustible calcium
silicate board.
12 TC36.CODE_290823-44
100004579
2
4
5
6
Figure 17: Framing kit assembly.
Item Part # Description Qty.
15049.9912 SCREW, TEKS #8 x 1/2” Pkg 40
2 9794.2 STUD, SIDES,48”L 2
3 9794.5 STUD, OUTER SIDES, 48”L 2
4 9093.22 STUD, CENTER,15 7/16”L 2
5 9193.501 STUD, HEADER, 49 7/8”L 1
6 9393.001 STUD, PLATE, 41 1/4”L 1
7 9194.5 BASE PLATE, 5 15/16”L 2
1. Top Frame Assembly
Lay out side studs (2) and center studs (4) on a large at surface.
Using the screws provided (1), attach the header stud (5) and the plate stud (6) to the center studs (4).
2. Attach Side Studs (Legs)
Attach the outer side studs (3) to the top of the header stud (5).
Fasten the outer side studs (3) at the bottom using the base plates (7).
Each Kit Contains:
1
2
3
4
5
6
7
Figure 16: Framing kit contents.
13
TC36.CODE_290823-44 100004579
TC36 Steel Stud Framing Kit
Adjustable Framing Kit
The lintel on the TC36 Out Door w
screen is in a xed position on the
replace and there is no adjustment to
move the lintel toward you or away from
you once the replace has been located
in its nal position. Instead, the replace
itself must be manoeuvered so that the
front face of the lintel determines the
nal position of the replace.
The Framing Kit allows for a 1-1/2 inch
adjustment along the Framing Brackets.
Use this range to help determine the
front of the facing material.
The thickness of the facing material,
wether 1/2 inch calcium silicate board or
a 1 1/2 inch rock facing must be taken
into consideration before settling on a
nal position of the replace.
Framing Kit Adjustment
Framing
Brackets
Figure 18: TC36 Fixed lintel.
Range: 1 1/2”
Figure 19: TC36 OD w screen Framing bracket.
14 TC36.CODE_290823-44
100004579
3
7
5
Figure 20: Outer studs.
Framing
brackets
5
7Access holes to
mounting screws
Figure 21: Framing brackets.
Figure 22: Installing non-combustible board.
3. Attach the Assembled Frame to the Unit.
Align the assembled frame to the unit framing
brackets (Figure 21). Set the depth of the framing
Kit based on the depth to the edge of the Lintel
needed for the nal facing materials.
Attach at the fastening points through the access
holes in the outer side studs, ensuring that the
assembly is parrallel to the unit. (item 3 in Figure
20).
4. Secure the frame assembly to existing framing
through the stud header (5) and the stud plates (7).
5. Install Non-combustible Board
Use drywall screws to install the non-combustible
board (Figure 22).
15
TC36.CODE_290823-44 100004579
Caution: While a hearth extension is not required and combustible flooring materials may be brought
directly up to the fireplace, many materials (such as wood flooring) may not tolerate the radiant heat
from this fireplace, resulting in discoloration, shrinking and cracking. For this reason, we suggest a
non-combustible hearth that is no more than 1” above the bottom of the fireplace. If thicker, fireplace
must be raised accordingly.
Caution: Hearth extensions thicker than 1” will interfere with the window frame when opening.
1/4"
Hearth
extension
Window
frame
1” Max
Window
track
Sub oor
Figure 23: Hearth extension details.
16 TC36.CODE_290823-44
100004579
Hearth Extension
This replace may be recessed up to a
maximum depth of 6”, this recess must be
constructed from non-combustible material.
The space between the outside framing
edge and the rebox must be completely
free of any obstructions or debris and the
window, with trim tted, must be able to
move freely. No building material is permitted
to protrude past the framing edges attached
to the replace under ANY circumstance.
Glass frame
Framing edges
Non-combustible
nish material
Figure 24: Finish material.
The gas control system is located on the right hand side of the rebox behind an access panel and the
decorative rebox panel (if installed). The replace is operated by a switch.
The switch (not supplied) is connected to the replace by a 14-2 AWG wire, not supplied with the replace.
Installation
1. Place the replace in the desired location.
2. Remove the window from the replace.
3. Remove access panel from right hand side of the rebox (Figure 25).
4. Remove the cover from the electrical box (Figure 26).
5. Run one 110 V. AC switched electrical supplies to the control box and connect to the transformer (Figure
27). The replace operates on 24V AC supplied by a transformer rated at 110 volts, 60Hz. See wiring
diagram on page 36 for correct connections on terminal block.
6. Connect the gas supply to the valve (Figure 28).
Honeywell Control Valve Plumbing and Electrical
Access panel
Figure 25: Access panel location.
Electrical box
cover
Figure 26: Electrical box cover.
Gas inlet
Figure 28: Gas inlet.
17
TC36.CODE_290823-44 100004579
Transformer electrical
connections
Figure 27: Transformer connections.
Supply
pressure
Manifold
pressure
Figure 29: Test ports.
Caution: The gas line should be installed by a qualified service person in accordance with all building
codes. This section is intended as a guide for qualified technicians installing this appliance. Consult
local and / or national building codes before proceeding.
Gas supply line access holes are located at the top and left sides of the Control Box. Gas valve inlet accepts
a 3/8" N.P.T. tting. Correct gas line diameter must be used to assure proper operation and pressure.
The replace has an input rate of 47,000 BTU/HR on both Natural Gas and Propane.
NOTE: A sediment trap, as per national fuel gas code, must be installed in the gas supply line no more
than 6 feet from the gas control valve to minimize the possibility of any loose scale or dirt within the
gas supply line from entering the control valve.
DO NOT HARD PIPE GAS LINE TO VALVE. A method of disconnecting the valve from the gas line such as a
union or are tting must be provided to allow for repair or replacement of the gas valve.
Check local codes for additional requirements.
1. Connect the gas supply to the valve (Figure 28).
2. Turn on the gas supply and check that all connections are tight and leak free.
Correct gas pressure requirement:
Natural Gas Propane
Min. Pressure 5.0" WC 12.5" WC
(For purpose of input adjustment)
Max. Pressure 13.9" WC 13.9" WC
Manifold Pressure
Maximum 3.8" WC 11" WC
Minimum 2.1" WC 5.5" WC
Note: To test the gas pressure, turn off the gas supply before removing the plug from the supply
pressure test port or manifold pressure test port.
Verify gas pressures with the replace lit and on the highest setting.
Please refer to the Burner Installation Manual for gas pressure testing procedure.
WARNING: Use EXTREME CAUTION when using soap and water to do a leak test on the valve/fittings. There
are electronics around and below the valve, that can/will be damaged if they come in contact with water.
WARNING: The access panel including gasket must be reinstalled after conversion/installation or servicing has
been completed. Failure to do so will cause overheating and premature failure of the control system.
18 TC36.CODE_290823-44
100004579
Gas Supply
Gas Pressure Check
Exterior wall opening:
Determine the exact position of the replace so that the vent pipe is centered (if possible) between
two building framing members. Consult your local building codes prior to proceeding. The vent kit will
accommodate up to a maximum wall thickness of 12 inches.
Having determined the position of the replace, cut and frame a 14 1/2 inch opening centered at a minimum
height of 68 1/2 inches above the oor. The opening may be round or square. Height of the opening will vary
with each installation. As the horizontal vent run increases, so does the minimum vertical rise as shown on the
chart on page 22.
IMPORTANT: When locating the opening, it should be noted that vent terminal clearances must be
maintained. See "Vent Terminal Clearances" section for proper clearances.
A minimum 2 foot length of pipe is required off the top of the replace for any wall termination. With
this minimum vertical rise in combination with a 90° elbow, a maximum horizontal run of 18 inches is
permitted (See chart on page 22. For longer horizontal runs greater than 18 inches, increase vertical rise
appropriately.
The rise and run must be constrained to the boundaries of the chart shown on page 22. The horizontal run
of vent must have a 1/4" rise for every 1 ft. of run towards the termination.
Before installing venting for this unit, the installer should read these instructions to insure that the proper vent
conguration has been selected.
Use only Town and Country Termination kits #: TCVT.WTA - Wall Termination Kit
TCVT.RTA - Roof Termination Kit
Vent system components approved for use with the Town and Country Fireplace are shown on page 20.
Various combinations of vertical and horizontal runs may be used. Refer to charts on page 19 22 and
page 23 for details. For optimum performance and ame appearance, keep the vent length to a minimum
and limit the number of elbows. Connections between each vent system component must be tightly joined,
secured with sheet metal screws and sealed with high temperature self adhesive tape. A horizontal run of vent
should have a 1/4" rise for every 1 ft. of run towards the termination.
CAUTION: UNDER NO CONDITION SHOULD COMBUSTIBLE MATERIAL BE CLOSER THAN 1 3/4 INCHES
FROM THE TOP AND 1 3/4 INCHES FROM THE SIDES OF A HORIZONTAL SECTION AND 1 3/4 INCHES
FROM THE VERTICAL SECTIONS OF THE VENT PIPE.
19
TC36.CODE_290823-44 100004579
Venting
Wall Termination Venting
Wall thimble:
Where a vent pipe passes through a combustible wall, a wall thimble/shield must be used to retain insulation
and maintain proper clearances. The wall thimble may be cut to length for various wall thicknesses up to 12"
thick.
Measure the wall thickness including the siding. Trim the shield to match the wall thickness. Position the wall
thimble from inside through the 14-1/2" opening. Properly adjusted, the thimble should be ush with the outer
wall surface.
Town & Country
12" Pipe Length ..................................................TCVT.811X12
18" Pipe Length ..................................................TCVT.811X18
24" Pipe Length ..................................................TCVT.811X24
48" Pipe Length ..................................................TCVT.811X48
12" Adjustable Pipe Length ......................... TCVT.811X12ADJ
45° Elbow ...................................................... TCVT.811XLB45
90° Elbow ...................................................... TCVT.811XLB90
Wall/Offset Support ...........................................TCVT.811XOS
Wall Termination Kit .................................................TCVT.WTA
Roof Termination Kit .................................................TCVT.RTA
Wall Shield/Ceiling Firestop ................................. TCVT.THIMA
Roof Flashing, Adjustable ............................. TCVT.811FLADJ
Roof Flashing, Flat ......................................... TCVT.811FLFLT
Roof Flashing, Steep ..................................... TCVT.811FLSTP
or any ashing that ts 11" pipe
Vent System Components
Wall thimble and vent must
not protrude beyond siding
Figure 30: Wall vent terminal. Figure 31: Thimble.
20 TC36.CODE_290823-44
100004579
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44

Town & Country Fireplaces TC36 / TC36 Arch Installation guide

Category
Fireplaces
Type
Installation guide
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI