Anybus AB7867 Installation guide

  • Hello! I have reviewed the datasheet for the Anybus ControlNet Adapter Interface. This document provides information on installation, LED indicators, and accessories needed for the device. The device supports both top and bottom mounting and uses LED lights to display its status and connection states. I am ready to answer any questions you may have about the ControlNet Adapter Interface.
  • What does a green GW Status LED indicate?
    What does a red flashing Ch. A or Ch. B LED indicate?
    How is the MAC address of the interface set?
Anybus X-gateway - ControlNet™ Adapter Interface Network Installation Sheet
www.anybus.comSP1755, rev. 2.00, Mar 2015
Accessories Checklist
The following items are required for installation:
USB cable (included)
• ControlNet con guration tool (not included)
• EDS le for ControlNet (see www.anybus.com)
ControlNet tap (not included)
• Termination resistor1 (optional, not included)
Installation and Startup Summary
(Depending on your setup, some steps may not be required.)
1. Connect the gateway to the network
2. Select an unused MAC ID with the rotary switches
3. Attach a termination resistor1 (optional)
4. Connect a PC to the gateway via USB (optional)
5. Power up and con gure the gateway
6. Install the EDS le in the ControlNet con guration tool
1 If node is installed at the end of the bus
LED Indicators
LED Indication Meaning
GW Status See Gateway Installation Sheet
MS
Green Initialized
Green ( ashing) Waiting for initialization
Red Major fault, unrecoverable
Red ( ashing) Minor fault, recoverable
Ch. A and Ch. B
Off Module not initialized
Red Major fault
Red ( ashing) Node con guration error
Red/green (alternating) Hardware self test
Ch. A or Ch. B
Off Channel disabled
Green Normal operation
Green ( ashing) Temporary error or not con gured
Red ( ashing) No other nodes or media fault
Red/green (alternating) Network con guration error
MO Off No connection has been opened
Green A connection has been opened
Top-mounted
GW Status
GW Status
USB
(X4)
USB
(X4)
B
otto
m-m
ou
n
ted
MS
Ch. A (X1.1)
Ch. B (X1.2)
MO
MS
Ch. A (X2.1)
Ch. B (X2.2)
MO
Product Overview
The ControlNet interface can be either top- or bottom-mounted.
Both of these options are illustrated below.
Top-mounted Interface
NAP
(X1.3)
Ch. A
(X1.1)
Ch. B
(X1.2)
MAC ID x 10
MAC ID x 1
Power Connector (X3)
Bottom-mounted Interface
NAP
(X2.3)
Ch. A
(X2.1)
Ch. B
(X2.2)
MAC ID x 10
MAC ID x 1
(NAP = Network Access Port)
MAC ID Switches
Two rotary DIP switches are used to set the MAC address of the
interface between 1 and 99.
Example:
MAC ID = 42 (4 x 10) + (2 x 1)
x10 x1
ODVA™ and ControlNet™ are trademarks of ODVA, Inc.
Technical Support
Technical support, documentation and software downloads are
available at www.anybus.com.
Technical questions regarding the ControlNet eldbus system should