7
Stage3–Normalfunction
Onswitchingonthecycleisautomaticallyactivated.Duringthepausetimethedisplayshowsalternatelythetime
remainingofthecycleandthemixerairpressure.AtthesametimetheLEDsatthesideofthedisplayare
illuminatedalternately.
Bypressingthe↑keyitispossibletofreezethedisplayofthemixerairpressurereadinguntilthekeyisreleased.
Bypressingthe↓keyitispossibletofreezethedisplayofthetimerreadinguntilthekeyisreleased.
Stage4–Alarmfunction
Inthealarmmodethedisplaystartsblinkingdisplayingtheerrorcode(seethe“troubleshooting”paragraph).
Whentheconditionshavebeenrestored,theRESETbuttonmustbepressedtoreturntonormalfunctioning.
7.3REGULATION
Toregulatealltheparameters,startthepumpandpresstheMODEkeyfor5seconds.Subsequentlyfollowthe
instructionsgiveninthetablebelow.
PressingtheMODEkeypassesfromoneoptiontothenext.
PARAMETERSDISPLAYDESCRIPTIONOPERATIONDEFAULT
Cyclecontrol
time
Themax.timeissetwithinwhichthedeliveryof
lubricantmustbeconfirmed.Therangeofregulationis
00‐60seconds
Enterthedesiredvaluesusingthe
↑and↓keys
5s
Pumprecharge
time
Pausetimeforrechargingthepump.Therangeof
regulationis0.0‐9.9seconds.
Enterthedesiredvaluesusingthe
↑and↓keys1.5s
Pausecycle
Intervaloftimebetweenonelubricationcycleandthe
next.Thecountcommenceswhenthedeliveryof
lubricantisconfirmed.Rangeofregulationis
00.00‐99.59minutes.
Enterthedesiredvaluesusingthe
↑and↓keys
User
discretion
Inversionof
solenoid
command
Relayfunction;1forNC,
0forNO.
Donotalter1
N°ofcontrol
elements
Numberofelementsinstalledwithflowcontrol.Ifthe
value0isset,beforeenteringinpause(pausetime),all
thetimeouttimemustpass.Rangeofregulation0‐99
elements.
Enterthedesiredvaluesusingthe
↑and↓keys
Min.1
Max.8
Max.air
Max.limitofmixerairpressure.Enteringthevalue0the
alarmisdisabled.Rangeofregulation0.0‐7.0bar
Enterthedesiredvaluesusingthe
↑and↓keys
User
discretion
Min.air
Min.limitofairpressure.Rangeofregulation0.0‐7.0
bar.
Enterthedesiredvaluesusingthe
↑and↓keys
User
discretion
Minimumoil
levelAlarmfunctionforminimumoillevel.
Enteringthevalue0anerroris
displayedbuttheVIP4Air
continuestooperate.
Enteringthevalue1anerroris
signaledandtheequipmentstops.
1
Systemstartpre‐
cycle
Numberofstartcyclesforsystempre‐lubrication.Range
ofregulation00‐60.
Enterthedesiredvaluesusingthe
↑and↓keysbearinginmind
thatthevalueofcyclesentered
mustbedoublethatofthedesired
value.
6
Cyclesoffault Numberofconsecutivefaultcyclesneededforanalarm.Enterthedesiredvaluesusingthe
↑and↓keys.2
AlarmStatus
Settheactiontotakeafteranalarm:
1=stopthelubricationcycles
0=Donotstopthelubricationcycles
Enterthedesiredvaluesusingthe
↑and↓keys.1
Alarmcoded
Settheoptionforalarmoutput:
1=Codedalarm(seePhar.8.1)
0=Standardalarm
Setthevalueby↑and↓buon0