UEi DTK2 User manual

  • Hello! I am an AI chatbot trained to assist you with the UEi DTK2 User manual. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
7
CE CERTIFICATE
The product complies with EMC directive 2004/108/EC
Technical standard: Emission EN 61326-1:2006 Class B
EN 55011:2009/A1:2010 Group 1 Class B
Immunity EN 61326-1:2006 EN 61000-4-2:2009
EN 61000-4-3:2006 A2:2010
8
BATTERY REPLACEMENT
• Turnofftheinstrument
• Removethebatterycompartment
• Changethebattery
• Replacethecompartmentcover
END OF LIFE
9
LIMITEd WARRANTY
TheDTK2iswarrantedtobefreefromdefectsinmaterialsand
workmanshipforaperiodofthreeyearsfromthedateofpurchase.If
withinthewarrantyperiodyourinstrumentshouldbecomeinoperative
fromsuchdefects,theunitwillberepairedorreplacedatUEi’soption.
Thiswarrantycoversnormaluseanddoesnotcoverdamagewhich
occursinshipmentorfailurewhichresultsfromalteration,tampering,
accident,misuse,abuse,neglectorimpropermaintenance.Batteries
andconsequentialdamageresultingfromfailedbatteriesarenot
coveredbywarranty.
Anyimpliedwarranties,includingbutnotlimitedtoimpliedwarranties
ofmerchantabilityandfitnessforaparticularpurpose,arelimited
totheexpresswarranty.UEishallnotbeliableforlossofuseofthe
instrumentorotherincidentalorconsequentialdamages,expenses,or
economicloss,orforanyclaimorclaimsforsuchdamage,expensesor
economicloss.Apurchasereceiptorotherproofoforiginalpurchase
datewillberequiredbeforewarrantyrepairswillberendered.
Instrumentsoutofwarrantywillberepaired(whenrepairable)fora
servicecharge.Returntheunitpostagepaidandinsuredto:
8030SWNimbusAvenue,BeavertonOR97008
• Accessories,probesandbatteries(NotCoveredbyWarranty)
• Claimsarenotacceptableforimproperuse(includingadaptation
toparticularapplicationsnotforeseenintheinstructionmanual
orimpropercombinationwithincompatibleaccessoriesor
equipment,orforrepaircarriedoutbyunauthorizedpersonnel.)
1-800-547-5740 • FAX: (503) 643-6322
www.ueitest.com • Email: [email protected]
Thiswarrantygivesyouspecificlegalrights.Youmayalsohaveother
rightswhichvaryfromstatetostate.
DTK2
DTK2
75.9
°
f
7
7
5
5
.
5
.
.
9
.
.
9
9
9
°
°
f
f
f
T1
K
T1
T1
K
K
76.1
°
f
7
7
6.1
6.1
°
°
f
f
f
T2
K
T2
T2
K
K
Differential Thermometer
1-800-547-5740 • Fax: (503) 643-6322
www.ueitest.com • Email: [email protected]
INSTRUCTION MANUAL
ENGLISH
Differential Thermometer
Temperature Units °F / °C
Sensor Type k-type
Range -328°~2498°F(-200°~1370°C)
Accuracy
Range Accuracy
-328°~-58°F(-200°~-50°C) ±(0.1%rdg+4°F(2.2°C))
-58°~1832°F(-50°~1000°C) ±(0.1%rdg+2°F(1°C))
1832°~2498°F(1000°~1370°C) ±(0.1%rdg+4°F(2.2°C))
Accuracy (after ice-
point calibration)
30°~120°F(-1.1~48.9°C) ±1°F(0.6°C)
Resolution 0.1°F/0.1°C
HOLD Yes
Max / Min T1 & T2
Differential (T1-T2) Yes
Operating / Storage
Operating Temperature
32~104°F(0~40
°C)
Operating RH% <70%RH,Non-condensing
Storage Temperature
-4~140°F(-20~60
°C)
Storage RH% <80%RH,Non-condensing
Battery Type 1x9V(NEDA1604)
Battery Life (typical) 125 hours typical
6
SPECIFICATIONS
CAUTION:Thissymbolindicatesthat
equipmentanditsaccessoriesshallbesubject
toaseparatecollectionandcorrectdisposal.
WARNING
Ifthesymbol“
“appearsontheLCD,
pleasereplacethebatteryimmediately.
Copyright©2013UEi.AllRightsReserved
06/13 17018
3
LCd dISPLAY
1. PrimaryLCD:DisplayT1(1stthermocouplereading)orT1-T2
2. SecondaryLCD:DisplayT2
4
OPERATION
• POWER ON/OFF
Note:
Make sure you have plugged in the thermocouple probe before
turning on.
PressandholdPWRbuttontoturnonthemeter.Whilethemeteris
on,pressPWRbuttontoturnoffthemeter.
• SLEEP MODE (AUTO POWER OFF)
Themeterwillturnoffautomaticallyafter15minutesifnobuttons
arepressed.Todisableautopowerofffunction,whenthemeter
isoff,pressandhold“HOLD”buttonthenpressPWR”button
toturnonthemeter,theprimaryLCDshowsthefollowing.Sleep
modeisnowdisabled.
• TAKING MEASUREMENT
Connectthermocouple.Ifprobeisopenornotconnected,theLCD
willshow”---”.
• DIFFERENTIAL (T1 - T2)
Press"MODE"todisplaydifferential.Press"MODE"againto
returntonormaldisplay.
MAX / MIN
PressMAX / MINbuttontochangeoperationmodefromlive
data->MAX->MIN->backtolivedata.Correspondingvaluewill
displayontheLCD.Thesevalueswillresetatpoweronorwhen
performingaresetonMAX/MIN.
Reset MAX/MIN:PressMax/Minbuttonfor2secondstoreset
MAX/MINanalysisvalue.TheMAX/MINvalueisupdatedto
currentreading.
DATA HOLD
Freezedisplayofbasicmeasurementsordisable.PressHOLD
buttonagaintogobacktothetemperaturereading.
• CHANGE UNIT
PressUNITbuttontochangeunit˚Cor˚F.Themeterdefault
temperatureunitis˚F.Themeterwilldefaulttolastselectedscale.
1
INTROdUCTION
ThankyouforpurchasingtheUEiDTK2dualinputKtype
differentialthermometer.Thisthermometerfeaturesabuilt-in
microprocessorandhighresolutionanalogtodigitalconverter
chip.Thethermocoupleproberespondsveryquicklytoawide
rangeoftemperaturemeasurements.Theindustrystandardmini
thermocouplejackacceptsawideselectionofprobetypes.
FEATURES
•Dualinputwithdifferential(T1-T2)
•Min/Maxcapture(T1&T2)
•Autopoweroffwithdisablefeature(15minutes)
•LargeLCDscreen
•Completewithbeadwiretemperatureprobesand9Vbattery
•˚C/˚Fselectfunction
•Magneticmount
INCLUDES
•Meter
•9Vbattery
•Operationmanual
• ATT29AK-typebeadprobe(2)
• Pouch
2
KEYPAd (CONTROLS)
T1
-
T2
HOLD
MAX MIN
K
K
2
1
MODE
SET
PWR
MAX
MIN
UNIT
HOLD
PRESS“UNIT”TOSELECT˚C/˚F.
Freezedisplay
Press“MODE”tochangeoperationmodeT1orT1-T2.
Thecorrespondingreadingwilldisplayontheprimary
LCD.ThesecondaryLCDwillalwaysdisplayT2.
Pressandhold“PWR” to turn on the meter or
pressittoturnoffthemeter.Themeterwillturnoff
automaticallyafter15minutesifyoudon’tpressany
key.PressHOLD”andPWR”buttonstodisable
Autosleepmode.
Press“MAX/MIN”tochangeoperationmode
fromlivedata->Max.->Min.->backtolivedate.The
correspondingvaluewilldisplayontheLCD.Thevalue
iscalculatedsincepoweredonorreset.
Pressandholdtoenterice-pointcalibration.(Please
refertosection
5
toensurecorrectcalibration.)
PressUNIT
K
K
K
K
SingleInput:(TopView)
K
K
T2
K
K
MIN
K
K
MAX
K
K
HOLD
K
K
5
AUTOMATIC ICE-POINT CALIBRATION
TheDTK2hasanautomaticice-pointcalibrationfunction.Please
followthesestepstocalibrateyourmetertothethermocouple
probes.
ITEMS NEEDED:
1. DTK2Thermometer
2. Twok-typeprobes
3. Crushedice/watermixture
(distilledwaterrecommendedifavailable)
CALIBRATION PROCEDURE
1. ConnectbothprobestotheDTK2
2. Placeprobetipsinthecrushedice/watermixture
3. PowerontheDTK2
4. PressandholdSETforfiveseconds.
a. Themeterwillenterice-pointcalibrationand0.0°Cwill
 flashonbothT1andT2readings
5. Stirtheicebathwiththeprobessubmergedforoneminute
6. Continuestirringtheice/watermixtureuntilthereadings
returntonormalmeasurement(flashingwillstop)
Theice-pointcalibrationisnowcomplete.
DTK2
75.9
°
f
75.9
°
f
T1
K
T1
K
76.1
°
f
76.1
°
f
T2
K
T2
K
Differential Thermometer
WARNING! Alwaysconnectthermocouplebeforeturningthe
unitonformostaccuratereadings.
WARNING! Makesuretoplugsensorwithcorrectpolarity.
Donotbealarmediferraticreadingsappearondisplayprior
tonormalmode.
MODE
K
K
K
K
/