DKS 9310 User manual

Category
Sewing machines
Type
User manual
Model 9310
Vehicular Slide Gate Operator
DoorKing, Inc.
120 Glasgow Avenue
Inglewood, California 90301
U.S.A.
Phone: 310-645-0023
Fax: 310-641-1586
www.doorking.com
Owner’s Manual
P/N 9310-065 Rev D 5/05
Copyright 2003 DoorKing, Inc. All rights reserved.
2
3
Use this manual with the following models only.
All 9310 models with circuit board 4403-010. IMPORTANT! The 4403 circuit board used in the
model 9310 IS NOT interchangeable with the 4402 circuit board used in the earlier model
9300 operators.
NOTE: Models 9310-081, 9310-083, 9310-085, 9310-087, 9310-089, 9310-091, 9310-093, 9310-
095 and 9310-097 will have a supplemental manual (P/N 2340-065) that describes the operation
and setup of the optional battery backup system available with this unit, and provides additional
wiring information for this unit.
DoorKing, Inc. reserves the right to make changes in the products described in this manual
without notice and without obligation of DoorKing, Inc. to notify any persons of any such revisions
or changes. Additionally, DoorKing, Inc. makes no representations or warranties with respect to
this manual. This manual is copyrighted, all rights reserved. No portion of this manual may be
copied, reproduced, translated, or reduced to any electronic medium without prior written consent
from DoorKing, Inc.
Mount operator to pad using 3/8 or 1/2 sleeve anchors.
See page 14-15.
1
2
Attach chain. Adjust chain to allow approximately 1-inch of sag per 10-feet of gate width.
Be sure to remove the pin from the breather plug.
See page 16-17.
3
Connect supply voltage as described in section 2.2. Be sure power is OFF!
See page 22.
4
Connect control wiring as shown. Radio receiver connects to terminals 1-2-3. Full open
input devices connect to terminals 4 and 13. Partial open input devices connect to
terminals 5 and 13. Terminals 1 and 13 are the same - 24 volt common.
5
Connect secondary entrapment prevention devices.
See page 24-25.
6
Connect in-ground loop wires to REVERSE and EXIT loop detectors as required.
See page 26.
7
Set close timer ON or OFF (SW-1, switch 2) as required. If gate system does not utilize in-
ground loop system or photo-cells, timer must be OFF.
See page 34-35.
8
Push gate to open position. Adjust OPEN limit nut to activate open limit switch. Push gate
closed. Adjust CLOSE limit nut to activate close limit switch.
See page 36.
9
Turn power ON. Give gate an open command. If gate runs towards CLOSE position, turn
power off. Change setting of direction switch (SW-1, switch 1) and then turn power ON.
Give gate an open command. Adjust limit nuts as necessary.
See page 36.
10
Adjust both open and close inherent reverse sensitivity. NOTE: Operator will assume a
"soft shutdown" during sensitivity adjustments. This will require operator open input to be
activated to resume normal operation.
See page 37.
QUICK START
4
9406
9406
EXIT LOOP
REVERSE LOOP
ON
123
1 DIRECTION
2 TIMER
1 Open Cycle Photocell
2 Close Cycle Photocell
3 Open Cycle Contact Sensor
4 Close Cycle Contact Sensor
5 Common
6 Common
Secondary
Entrapment
Protection
Devices
CAUTION
16-20 HIGH VOLTAGE!
TIMER
REV SENS
OPEN
REV SENS
CLOSE
TIME DELAY
1 2 3 4 5 6 7 8 1 2 3 4
ON
REVERSE
LOOP
GATE FORCED
EARTH GROUND
CAPACITOR CONNECTOR
REVERSING DEVICE
CONNECTOR
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
POWER
EXIT
LOOP
LIMIT SWITCH
CONNECTOR
LIMIT
PARTIAL
LIMIT
RELAY CONTACT
CLOSE OPEN
SENSITIVITY
24V Com
Relay
Radio Pwr
3-Wire
Receiver
4-Wire
Receiver
24V Com --
Relay
Relay
Radio Pwr +
1
1
2
3
Fire
Dept
NOTE
Terminal 1 and 13
are the same.
Either can be used
as a low voltage
common.
Current Sensor Donut
HP Volt-Ph Turns
1/2
1
1
1
1
All
Sgl Ph
208-3
230-3
460-3
2
1
5 *
5 *
9 *
* CURRENT SENSOR DONUT
For 1HP 3-Phase motors, the RED current
sensor wire is connected directly to the
lug opposite of terminal 19. The black
motor wire is routed through the donut
with the number of turns shown in the
table. Refer to the wire diagrams in the
back of the manual.
5
TABLE OF CONTENTS
Important Notices......................................................................................................................................................8
Important Safety Instructions....................................................................................................................................9
Restrictions and Warnings........................................................................................................................................10
Entrapment Prevention.............................................................................................................................................11
Glossary ..................................................................................................................................................................12
Section 1 – Installation
1.1 Specifications ...........................................................................................................................................13
1.2 Concrete Pad............................................................................................................................................14
1.3 Operator Installation.................................................................................................................................15
1.4 Chain Installation......................................................................................................................................16
1.5 Front Mount Installation............................................................................................................................17
1.6 Rear Mount Installation.............................................................................................................................18
1.7 Warning Sign Installation..........................................................................................................................19
Section 2 – Wiring
2.1 Conduit Requirements..............................................................................................................................21
2.2 High Voltage Connections........................................................................................................................22
2.3 Control Wiring...........................................................................................................................................23
2.4 Secondary Entrapment Non-Contact Sensors .........................................................................................24
2.5 Secondary Entrapment Contact Sensors.................................................................................................25
2.6 Loop Detector Wiring................................................................................................................................26
2.7 Gate Tracker™ Connections....................................................................................................................27
2.8. Alarm Reset Switch..................................................................................................................................28
2.9 Auxiliary Stop Input...................................................................................................................................28
2.10 Master / Slave Wiring Interface ................................................................................................................29
2.11 Secondary Entrapment Protection for Master / Slave Configuration........................................................30
2.12 Terminal Identification and Description ....................................................................................................31
2.13 Secondary Device Terminal Description ..................................................................................................32
Section 3 – Adjustments
3.1 Circuit Board Adjustments........................................................................................................................33
3.2 Switch Settings.........................................................................................................................................34
3.3 Programming Switch Description and Function........................................................................................35
3.4 Limit Switch Adjustment ...........................................................................................................................36
3.5 Reverse Sensitivity Adjustment................................................................................................................37
6
Section 4 – Operating Instructions
4.1 Power and Reset Switches ......................................................................................................................39
4.2 Shutdown Conditions ...............................................................................................................................40
Soft Shutdown..........................................................................................................................................40
Resetting a Soft Shutdown.......................................................................................................................40
Hard Shutdown.........................................................................................................................................41
Resetting a Hard Shutdown .....................................................................................................................41
4.3 Manual / Emergency Gate Operation.......................................................................................................42
Section 5 – Maintenance and Troubleshooting
5.1 Maintenance Schedule.............................................................................................................................45
5.2 Operator Diagnostics................................................................................................................................46
5.3 Trouble Shooting......................................................................................................................................47
½ HP 115 VAC Wire Diagram..................................................................................................................49
½ HP 208/230/460 VAC Wire Diagram....................................................................................................50
1 HP 115 VAC Wire Diagram...................................................................................................................51
1 HP 208/230 VAC Single Phase Wire Diagram......................................................................................52
1 HP 208/230/460 VAC Three Phase Wire Diagram ...............................................................................53
5.4 Accessories..............................................................................................................................................54
7
IMPORTANT NOTICES
Vehicular gate systems provide convenience to their users and limit vehicular traffic onto your
property. These systems can produce high levels of force; therefore it is important that you are aware
of possible hazards associated with your gate operating system. These hazards may include pinch
points, entrapment, absence of controlled pedestrian access or traffic backup.
Be sure that the installer has instructed you on the proper operation of the gate and gate operator
system. Be sure that the installer has trained you about the basic functions of the required reversing
systems associated with your gate operating system and how to test them. These include reversing
loops, inherent reversing system, electric edges, photoelectric cells, or other external devices.
This Owner's Manual is your property. Keep it in a safe place for future reference.
Loops and loop detectors, photo-cells or other equivalent devices must be installed
with this gate operator to prevent the gate from closing on vehicular traffic.
The speed limit for vehicular traffic through the gate area is 5 MPH. Install speed bumps and
signs to keep vehicular traffic from speeding through the gate area. Failure to adhere to
posted speed limits can result in damage to the gate, gate operator, and to the vehicle.
Be sure that all residents are familiar with the proper use of the gate and gate operator. Be
sure that all residents are familiar with the possible hazards associated with the gate system.
Be sure that all warning signs are permanently installed on both sides of the gate in an area
where they are fully visible to traffic.
It is your responsibility to periodically check all reversing devices. If any of these devices are
observed to function improperly, remove the operator from service immediately and contact
your installing or servicing dealer.
Follow the recommended maintenance schedule.
Do not allow children to play in the area of the operator or to play with any gate-operating
device.
Be sure that all activating devices are installed a minimum distance of 10 feet away
from the gate and gate operator, or in such a way that a person cannot touch the gate
or gate operator while using the activating device. If activating devices are installed in
violation of these restrictions, immediately remove the gate operator from service and
contact your installing dealer.
To remove the gate operator from service, operate the gate to the full open position and then
shut off power to the operator at the service panel.
VEHICULAR
TRAFFIC
PEDESTRAINS
SPEED BUMP
SPEED BUMP
HAZARD AREA
HAZARD AREA
8
IMPORTANT SAFETY INSTRUCTIONS
WARNING - To reduce the risk of injury or death:
1. READ AND FOLLOW ALL INSTRUCTIONS.
2. Never let children operate or play with gate controls. Keep the remote control
away from children.
3. Always keep people and objects away from gate. NO ONE SHOULD CROSS
THE PATH OF THE MOVING GATE.
4. Test the operator monthly. The gate MUST reverse on contact with a rigid object
or stop or reverse when an object activates the non-contact sensors. After
adjusting the force or the limit of travel, retest the gate operator. Failure to adjust
and retest the gate operator properly can increase the risk of injury or death.
5. KEEP GATES PROPERLY MAINTAINED. Read the owner's manual. Have a
qualified service person make repairs to gate hardware.
6. The entrance is for vehicles only. Pedestrians must use separate entrance.
7. SAVE THESE INSTRUCTIONS!
Gate Construction
Vehicular gates should be constructed and installed in accordance with ASTM F2200-02; Standard
Specification for Automated Vehicular Gate Construction. For a copy of this standard, contact
ASTM directly at 610-832-9585; serv[email protected]; or www.astm.org.
9
RESTRICTIONS AND WARNINGS
Install The Gate Operator Only If:
The operator is appropriate for the usage Class of the application and the gate is within the
weight and length limitations specified for the operator.
All openings of a horizontal slide gate are guarded or screened from the bottom of the gate to
a minimum of 4 feet (1.2 m) above the ground to prevent a 2 ¼ inch (57.15 mm) diameter
sphere from passing through the openings anywhere in the gate, and in that portion of the
adjacent fence that the gate covers in the open position.
All exposed pinch points are eliminated or guarded.
This operator is intended for installation only on slide gates used to control vehicular traffic.
Pedestrians must be provided with a separate access opening.
The gate must be installed in a location so that sufficient clearance is provided between the
gate and adjacent structures when opening and closing to reduce the risk of entrapment (see
diagram). Sliding gates should not open into public access areas.
The gate must be properly installed and work freely in both directions prior to the installation
of the gate operator. Do not reduce reversing sensitivity to compensate for a damaged gate.
Controls must be far enough from the gate so that the user is prevented from coming in
contact with the gate while operating the controls. Outdoor or easily accessible controls
should have a security feature to prevent unauthorized use.
All warning signs and placards must be installed where visible in the area of the gate.
Roadway
Pedestrian
Access
Fence
Vehicular Gate
Sidewalk
Gate Operator
Fence
All openings of a horizontal slide gate are guarded or screened from the
bottom of the gate to a minimum of four (4) feet (1.2 m) above the ground
to prevent a 2 1/4 inch (57.15 mm) diameter sphere from passing through
the openings anywhere in the gate and in that portion of the adjacent
fence that the gate covers in the open position. (ref. UL325 56.8.4.a.2)
The operator is
intended for
installation only on
gates used for
vehicles. Pedestrians
must be supplied with
a seperate access
opening. (ref. UL325
56.8.4.b)
Fence
4 ft.
min
Gate
V-Track
Spacing must be such
that a 2 1/4 inch sphere
cannot pass through.
10
ENTRAPMENT PREVENTION
This vehicular gate operator is equipped with an inherent (Type A) entrapment sensing system. This
system will sense an obstruction in both the opening and closing gate cycles, and will cause the gate
to reverse direction should an obstruction be encountered. If the system detects a second obstruction
before reaching the full open or close limit after the initial reversal, an alarm will activate and the
operator will require a reset before resuming normal operation. See Section 4 for more information.
EXTERNAL ENTRAPMENT PREVENTION
Non-contact and/or contact sensors must be installed individually or in combination with each other to
provide external entrapment prevention. For gate operators utilizing a non-contact sensor:
See diagram below for placement of non-contact sensors.
Care should be exercised to reduce the risk of nuisance tripping, such as when a vehicle trips
the sensor while the gate is still moving, and
One or more non-contact sensors shall be located where the risk of entrapment or
obstruction exists, such as the perimeter reachable by a moving gate or barrier.
Gate
Fence
Entrapment area exist between the gate
and the adjacent fence when the gate is in
the opening cycle.
Open beam protects area
between the gate and
adjacent fence during the
open cycle.
Close beam prevents gate
from hitting obstructions
during the close cycle.
For gate operators utilizing a contact sensor:
A hardwired contact sensor shall be located and it’s wiring arranged so that the
communication between the sensor and the gate operator is not subjected to mechanical
damage.
A wireless contact sensor such as one that transmits radio frequency (RF) signals to the gate
operator for entrapment prevention functions shall be located where the transmission of the
signals are not obstructed or impeded by building structures, natural landscaping or similar
obstruction. A wireless contact sensor shall function under the intended end-use conditions.
Gate
Fence
Entrapment area exist between the gate
and the adjacent fence when the gate is in
the opening cycle.
Leading Edge
Trailing Edge
Inside
Outside
11
GLOSSARY
GATE – A moving barrier such as a swinging, sliding, raising, lowering, or the like, barrier, that is a
stand-alone passage barrier or is that portion of a wall or fence system that controls entrance and/or
egress by persons or vehicles and completes the perimeter of a defined area.
RESIDENTIAL VEHICULAR GATE OPERATOR-CLASS I - A vehicular gate operator (or system)
intended for use in a home of one-to four single family dwelling, or garage or parking area associated
therewith.
COMMERCIAL / GENERAL ACCESS VEHICULAR GATE OPERATOR-CLASS II - A vehicular gate
operator (or system) intended for use in a commercial location or building such as a multi-family
housing unit (five or more single family units), hotels, garages, retail store, or other building servicing
the general public.
INDUSTRIAL / LIMITED ACCESS VEHICULAR GATE OPERATOR-CLASS III - A vehicular gate
operator (or system) intended for use in an industrial location or building such as a factory or loading
dock area or other locations not intended to service the general public.
RESTRICTED ACCESS VEHICULAR GATE OPERATOR-CLASS IV - A vehicular gate operator (or
system) intended for use in a guarded industrial location or building such as an airport security area
or other restricted access locations not servicing the general public, in which unauthorized access is
prevented via supervision by security personnel.
SYSTEM - In the context of these requirements, a system refers to a group of interacting devices
intended to perform a common function.
WIRED CONTROL - A control implemented in a form of fixed physical interconnections between the
control, the associated devices, and an operator to perform predetermined functions in response to
input signals.
WIRELESS CONTROL - A control implemented in means other than fixed physical interconnections
(such as radio waves or infrared beams) between the control, the associated devices, and an
operator to perform predetermined functions in response to input signals.
INHERENT ENTRAPMENT SENSOR SYSTEM - An automatic sensor system, which senses
entrapment of a solid object and is incorporated as a permanent and integral part of the operator.
ENTRAPMENT – The condition when an object is caught or held in a position that increases the risk
of injury.
12
SECTION 1 - INSTALLATION
Prior to beginning the installation of the slide gate operator, we suggest that you become familiar with
the instructions, illustrations, and wiring guide-lines in this manual. This will help insure that your
installation is performed in an efficient and professional manner.
The proper installation of the vehicular slide gate operator is an extremely important and integral part
of the overall access control system. Check all local building ordinances and building codes prior to
installing this operator. Be sure your installation is in compliance with local codes.
1.1 Specifications
Class of Operation: Class I, II, III, IV
Type of Gate: Vehicular Slide Gates Only
Horsepower: 1/2 HP and 1 HP
Voltage: 1/2 HP: 115, 208, 230, 460
1 HP: 115 – 230 1
Ø
, 208 / 230 / 460 3
Ø
Current: Varies with voltage and phase. See page 22.
Max Gate Weight
1
: 1000 Lbs. (1/2 HP)
2
, 1500 Lbs. (1 HP)
2
Max Gate Length
1
: 30 Ft. (1/2 HP), 45 Ft. (1 HP)
Cycles / Hr: 60/Hr
Speed: Approximately 1 Ft./Sec.
Entrapment Protection: Primary – Inherent (Type A)
Secondary – Provision for connection of a non-contact
sensor (Type B1) and/or a contact sensor (Type B2).
Secondary entrapment protection devices are not supplied
with the operator and must be ordered separately.
Note 1: Assumes gate is in good working condition installed on a
level surface.
Note 2: Operators with Convenience Open Option
800 Lbs. (1/2 HP), 1300 Lbs. (1 HP)
28.5 (1 HP)
27.5
16.5
11
21.5 (1/2 HP)
13
1.2 Concrete Pad
The model 9310 vehicular gate operator is designed to be mounted on a concrete pad.
1. Construct a form for the mounting pad according to the specifications shown below. Note
that the pad for the 1 HP operator extends an additional 6 inches to the right to
accommodate the larger cover. Be sure to level the top edge of the form and that the
top of the form is a minimum of four (4) inches above ground level. We suggest that you
contact the local building department to determine the required depth of the pad since
soil conditions and code requirements vary from city to city.
2. Set conduits, reinforcing bars and/or wire mesh if required. If the slide gate operator
has a battery backup system, then conduits must be located in the area shown.
The number of conduits is determined by the application requirements. We suggest using
a minimum of four (4) conduits. 1-High voltage power lines; 2-Low voltage control lines;
3-Loop lead-in wires (open loop); 4-Loop lead-in wires (reverse loops). See SECTION 2.
3. Mix the concrete according to the manufacturers instructions. Pour the mixture into the
form and tamp. Level and finish the surface after pouring is complete. Do not set anchor
bolts in the concrete. Sleeve anchors should be used to secure the operator to the pad.
This allows greater flexibility in positioning the operator on the pad.
4. Allow the pad to cure for 48 hours before removing the forms or mounting the operator.
26.5 ½ hp
18.5
4
3 3/4
Min
GATE
1
6
GATE BRKT
CONDUIT
AREA FOR
UNITS WITH
BATTERY B/U
4" Minimum Above
Ground Level
5 6.5
Depth of pad determined by soil
conditions and local code.
4
7
18.5
14
6
32.5 1 hp
Cover 1 HP
Cover 1/2 HP
10
14
1.3 Operator Installation
Position the operator on the pad so that
there is a minimum clearance of one (1)
inch between the back of the operator
housing and the gate.
90°
IMPORTANT!! Be sure that the operator
is parallel to the gate! Installing the
operator in any other manner will cause
excessive chain noise, chain wear and
stretching, and premature idler failure.
Mark the mounting holes on the mounting
pad. Use a concrete drill bit to drill the
mounting holes to the size and depth
required for the anchors being used. We
recommend 1/2 x 2 or 3/8 x 2 sleeve
anchors (not supplied).
NO!
After drilling the mounting holes, clean
them out and install the sleeve anchors.
Position the operator over the anchors
and tighten.
15
1.4 Chain Installation
1. Secure the chain brackets to each end of the
gate so that the brackets are level with the
top chain cutouts in the operator housing.
Brackets should be attached to the inside of
the frame so that the chain bolts, when
attached, do not protrude beyond the frame
of the gate.
2. Remove the breather plug pin from the
gear-box and discard it (page 17).
3. Route the chain through the gate operator:
under the chain guide idlers and over the
drive sprocket.
4. Attach the chain to the chain bolts using the
master links supplied, and then attach the
chain bolts to the chain brackets using the
hardware supplied. Make any adjustments to
the chain length at this time.
5. Adjust the chain bolts to tighten the chain.
The chain should sag no more than one (1)
inch per 10 feet of travel. Do not over tighten
the chain. IMPORTANT!! Be sure that the
chain is parallel to the gate. Installing the
chain in any other manner will cause
excessive noise, chain idler wear and
chain stretching.
6. If the operator is to be rear mounted, an
endless idler assembly (P/N 2600-818) is
required. Depending on the length of the
gate, additional chain may also be required.
See detail on page 18.
NO!
16
1.5 Front Mount Installation
48
GROUND LEVEL
CONCRETE PAD
REMOVE
BREATHER
PLUG PIN
17
1.6 Rear Mount
48
GROUND LEVEL
CONCRETE PAD
REMOVE
BREATHER
PLUG PIN
Gate Brackets
Idler Assembly
P/N 2600-818
18
1.7 Warning Sign Installation
This DoorKing slide gate operator is shipped with two warning signs. The purpose of the warning
signs is to alert uninformed persons, and to remind persons familiar with the system, that a potential
hazard may exist so that appropriate action can be taken to avoid the hazard or to reduce exposure
to the hazard.
WARNING
Moving Gate Can Cause
Serious Injury or Death
KEEP CLEAR! Gate may move at any time
without prior warning.
Do not let children operate the gate or play
in the gate area.
This entrance is for vehicles only.
Pedestrians must use separate entrance.
1. Permanently install the supplied warning signs in locations
so that the signs are visible by persons on both sides of
the gate.
2. Use appropriate hardware such as wood or metal screws
(not supplied) to install the warnings.
19
20
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55

DKS 9310 User manual

Category
Sewing machines
Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI