  • Hello! I am an AI chatbot trained to assist you with the Comtrol ES7206-XT Installation guide. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
QUICK INSTALLATION GUIDE
2000584 Rev E | Release Date - March 2014
ROCKETLINX ES7206-XT
Industrial PoE Plus Switch
INTRODUCTION
The RocketLinx ES7206-XT is an industrial 6-port Gigabit 802.3af/at PoE
Voltage Boost Switch.
SeetheComtrolwebsiteforproductspecicaons.
INSTALLATION OVERVIEW
YoucanusethefollowinginformaontoinstalltheES7206-XT.TheES7206-XT
istobeconnectedtoPoEnetworkswithoutroungtooutsidetheplant.
Wiring the Power Inputs
TheES7206-XTprovidesredundantpower,reversepolarityprotecon,over-
currentproteconandacceptsaposiveornegavepowersourcebutPWR1
andPWR2mustbeappliedwithpowersourcesofthesamepolarity.
Theterminalblockaccepts12-24AWGwire.UseaULlistedpowersupply
withtherequiredoutputvoltageof12-36VDCtodeliverIEEE802.3atPoEPlus
onallPoEports(Ports1-4).Thepowersupplymustberatedasfollows:
802.3af-96Was(Minimum)
802.3at-168Was(Minimum)
1
Power Supply
AC Power Input
12-36VDC/7A
(UL Listed)
V+
V-
Wiring Posive Power Supplies
Power Supply
AC Power Input
12-24AWG
12-24AWG
V+
V-
DC Power Input
12-36VDC
12-36VDC
DC Power Input
12-36VDC/7A
(UL Listed)
Relay
PWR1PWR2
+
-
+
-
Powershouldbedisconnectedfromthepowersupplybeforeconnecngitto
the switch. Otherwise, your screwdriver blade can inadvertently short your
terminalconneconstothegroundedenclosure.
1. InserttheposiveandnegavewiresintoPWR+andPWR-contacts
(PWR1andPWR2).Youcanconnectasinglepowersupplyortwopower
supplies depending on your requirements.
Ifbothpowerinputsareconnected,theES7206-XTwillbepowered
fromthehighestconnectedvoltage.Theunitcanbeconguredto
signalanalarmforlossofpowerineitherPWR1orPWR2.
2. Tighten the wire-clamp screws to prevent the wires from being
loosened.
Note: When the ES7206-XT is in operaon, cauon must be taken to not touch the hot
surface of the product enclosure.
Electrical Specicaons Value
PowerInput 12-36VDC
PowerConsumpon
(withoutPDloading)
840mA@12VDC
420mA@24VDC
280mA@36VDC
PowerConsumpon
(withPDloading)
IEEE802.3af:6.25@12VDC
IEEE802.3af:4A@24VDC
IEEE802.3at:7A@24VDC
IEEE802.3af:2.67A@36VDC
IEEE802.3at:4.67A@36VDC
MaximumOutput/PowerPoEPort 15W(IEEE802.3af)
30W(IEEE802.3at)
(table connued on next page)
2
3
Electrical Specicaons Value
Total PoE Power
Budget
VIN=12VDC 60W@-40°to70°C
55W@70°to75°C
VIN=24VDC 110W@-40°to65°C
100W@65°to75°C
VIN=36VDC 110W@-40°to65°C
100W@65°to75°C
Operang Temperature -40°to75°C
Storage Temperature -40°to85°C
Note: Exceeding the recommended power and operang temperatures may
result in failures or damage.
Wiring the Alarm Relay Output
Thealarmrelayoutputordigitaloutput(DO)contactsareontheterminal
block connector. The alarm relay output contacts are normally open. The
alarmrelayoutputcontactsclosewhenthealarmisenabledwiththeDIP
switches and there is a port link failure or PoE failure on a port.
Therelaycontactsupportsupto0.5Aat24VDC.Donotapplyvoltageand
currenthigherthanthespecicaons.
Thealarmrelayoutputiscontrolledbythepre-denedrules.Toacvatethe
alarmrelayoutputfuncon,refertothefollowingdrawing.
Earth Ground
+
Alarm Relay Output
DIP Switch
Alarm Control
Alarm
Relay
PWR2 PWR1
Power
Source
Buzzer/
PLC
Input
12 - 24
AWG Wire
24VDC/0.5A (Max)
Seng the DIP Switch
TheES7206-XThasan8-pinDIPswitchlocatedontheboompanelto
congurethePortLinkAlarmfortheEthernetports.Thefollowingtable
showstheDIPswitchnumbermappingtothecorrespondingopons.
Port
1
Port
2
Port
3
Port
4
Port
5
Port
6
PWR
Alm
SFP
100
DIP1 DIP2 DIP3 DIP4 DIP5 DIP6 DIP7 DIP8
ThistableshowstherelaonshipbetweentheDIPswitchnumber,posion,
andfuncon.
Switch Posion Funcon
1-6 ON Enables port failure alarm for corresponding port
OFF(Default) Disablesportfailurealarmforcorrespondingport
7 ON Enables power event alarm
OFF(Default) Disablespowereventalarm
8 ON EnablesSFPportfor100BASE-FX
OFF(Default) Supports Gigabit SFP in SFP port
Note: Aer connecng the SFP or changing the speed through DIP 8, cycle the
power to acvate the SFP.
Grounding the ES7206-XT
Wiretheearthgroundtoensurethesystemisnotdamagedbynoiseorany
electricalshock,werecommendthatyoumakeadirectconneconbetween
the ES7206-XT and earth ground.
Usingascrewdriver,loosentheearthgroundscrewontheboomof
theES7206-XTandthenghtenthescrewaertheearthgroundwireis
connected.
4
5
Mounng the ES7206-XT
TheDINrailclipisaachedtotheES7206-XT.
1. InserttheupperendofDINrailclipintothebackofDINrailtrackfrom
its upper side.
2. LightlypushtheboomofDINrailclipintothetrack.
3. VerifythattheDINrailclipisghtlyaachedonthetrack.
Note: When the ES7206-XT is in operaon, cauon must be taken to not
touch the hot surface of the product enclosure.
Connecng the RJ45 Ethernet Ports
Connect one end of an Ethernet cable into the Ethernet port of the
ES7206-XTandtheotherendtotheaachednetworkingdevice:
Ports1-4areGigabitPoEportsthatsupportIEEE802.3af/802.3at(PoE+)
Port5isaGigabit(10/100/1000BASE-TX)port
Port6isaGigabitSFPport,whichisdiscussedinthenextsecon
TheportssupportGigabithalf/full-duplex.AllRJ45portsauto-detectthe
signalfromconnecteddevicestonegoatethelinkspeedandduplexmode.
AutoMDI/MDIXallowsuserstoconnectanotherswitch,hub,orworkstaon
without changing straight-through or crossover cables.
Link/ActLEDsarelittoindicatetracandlinkstatus,seetheLEDssubsecon
formoreinformaon.
1000BASE-TX
Alwaysmakesurethatthecablesbetweentheswitchesandaacheddevices
(forexample,switch,hub,orworkstaon)arelessthan100meters(328
feet).YoushoulduseCategory5cableorhigher.
Connecng the SFP Port
You can connect an SFP transceiver to Port 6. Comtrol recommends using
Comtrol-approved SFP transceivers. Cross-connect the transmit channel at
each end to the receive channel at the opposite end as illustrated in the
gure.
MakesurethatyouuseanSFPbertransceivercompliantwithUL
cercaonandEN60825Class1.
LED INDICATORS
LED Status Descripon
PWR1/2 Green The terminal block is receiving power
O The terminal block is not receiving power
(table connued on next page)
6
A B
TX
RX
TX
RX
LED Status Descripon
Alm Red Oneofthefollowinghasoccurred:
Port link failure has occurred
PowerhasbeenremovedfromPWR1orPWR2
Port6SFPis100BASE-FXandhaslost
connecon/link
O Nofailurehasbeenfound
PoE 1-4 Yellow TheportisprovidingPoEpowertothePD
O NoPDisaached
P 1-5
LNK/ACT
Green Anetworkdeviceisaached
Blinks ThereisavalidEthernettransmit/receiveacvity
to/from the connected network device
O Theportlinkisnotacve
P6
LNK
Green Anetworkdeviceisaached
Blinks ThereisavalidEthernettransmit/receiveacvity
to/from the connected network device.
O Theportlinkisnotacve
COMTROL CUSTOMER SERVICE
You can use one of the following methods to contact Comtrol.
Contact Method Web Address or Phone Number
Support hp://www.comtrol.com/support
Downloads p://p.comtrol.com/html/default.htm
Website hp://www.comtrol.com
Phone +1763.957.6000
7
/