mundoclima Series MU-CA “Superficial Air Curtain” Installation guide

Type
Installation guide
1
CORTINAS DE AIRE
AIR CURTAINS
RIDEAUX D'AIR
MU-CA 100 AN / 150 AN / 200 AN
MU-CA 100 RN-3,5
MU-CA 100 RN-6
MU-CA 100 RN-9
MU-CA 150 RN-9
MU-CA 150 RN-12
MU-CA 200 RN-18
MANUAL DE INSTALACIÓN. INSTRUCCIONES DE USO
INSTALLATION AND OPERATION MANUAL
NOTICE D'INSTALLATION ET D'UTILISATION
MUND CLIMA®
5
230V
~
50Hz
MIN. 3x1 mm
2
MIN. 3x0,5 mm
2
L 2 1
a
1
2
21 L
L N
230V
~
50Hz
MIN. 3x4 mm
2
L N
MIN. 5x0,5 mm
2
1
1
1
1
R2 75V 1160W
R3 75V 1160W
2
0
2
F
4
6
8
2 3 4
2 3 4 6 7
5 6
R1 75V 1160W
MU-CA 100 AN / MU-CA 150 AN / MU-CA 200 AN
MU-CA 100 RN-3,5
CONTROL - MUCR-A
CONTROL - MUCR-3,5 N
SECUENCIA CONEXIONES
SECUENCIA CONEXIONES
POSICIONES
POSICIONES
CIRCUITOS
CIRCUITOS
1
2
3
4
d
Fig. 5
Fig. 5
6
3N400V ~50Hz
MIN. 5x2,5 mm
2
R1 230V 2000W
R2 230V 2000W
R3 230V 2000W
1 2 3 4 5
6
7
MIN. 6x0,5 mm
2
1 2 3 4 5 6 7
L1 L2 L3 N
0
1
4
2 6
8
F
A2
A1
L3
L2 L1
T3
T2 T1
MU-CA 100 RN-9
MU-CA 100 RN-6
CONTROL - MUCR-6/9
SECUENCIA CONEXIONES
POSICIONES
CIRCUITOS
1
2
3
4
d
R3 230V 1500W
R3 230V 1500W
R2 230V 1500W
R2 230V 1500W
R1 230V 1500W
R1 230V 1500W
1 2 3 4 5 6
A2
A2
Kw1
Kw2
A1
A1
L3
L3
L2
L2
L1
L1
T3
T3
T2
T2
T1
T1
7
L1 L3 NL2
3N400V ~50Hz
MIN. 5x2,5 mm
2
MIN. 6x0,5 mm
2
CONTROL - MUCR-6/9
SECUENCIA CONEXIONES
POSICIONES
CIRCUITOS
1
2
3
4
d
Fig. 5
Fig. 5
7
3N400V ~50Hz
MIN. 5x2,5 mm
2
MIN. 6x0,5 mm
2
1 2 3 4 5
6
7
L1 L2 L3 N
R1 230V 3000W
R2 230V 3000W
R3 230V 3000W
1
0
4
2
5
6
A1
L3 L2 L1
A2
T3 T2 T1
MU-CA 150 RN-12
3N400V ~50Hz
MIN. 5x4 mm
2
MU-CA 150 RN-9
CONTROL - MUCR-6/9
SECUENCIA CONEXIONES
POSICIONES
CIRCUITOS
1
2
3
4
d
CONTROL - MUCR-6/9
SECUENCIA CONEXIONES
POSICIONES
CIRCUITOS
1
2
3
4
d
MIN. 6x0,5 mm
2
1
2 3
4
5 6
L1
L2
L3
N
R3 230V 2000W
R3 230V 2000W
R2 230V 2000W
R2 230V 2000W
R1 230V 2000W
R1 230V 2000W
A1
A1
L3
L3
L2
L2
L1
L1
A2
A2
Kw1
Kw2
T3
T3
T2
T2
T1
T1
7
Fig. 5
Fig. 5
8
MU-CA 200 RN-18
3N400V ~50Hz
MIN. 5x6 mm
2
CONTROL - MUCR-6/9
SECUENCIA CONEXIONES
POSICIONES
CIRCUITOS
1
2
3
4
d
MIN. 6x0,5 mm
2
1
2
3
4
5
6
L1
L2
L3
N
R3 230V 3000W
R3 230V 3000W
R2 230V 3000W
R2 230V 3000W
R1 230V 3000W
R1 230V 3000W
A1
A1
L3
L3
L2
L2
L1
L1
A2
A2
Kw1
Kw2
T3
T3
T2
T2
T1
T1
7
Fig. 5
11
R1 230V 3000W
R2 230V 3000W
R3 230V 3000W
R1 230V 3000W
R2 230V 3000W
R3 230V 3000W
T3
L3
A1
A2
T2
L2
T1
L1
1
0
F
8
6
2
4
L1 L2 L3
N
L1 L2 L3 N
1
1
2
3
4
4
5
6
7
1
0
F
8
6
2
4
T3
L3
A1
A2
T2
L2
T1
L1
3N400V ~50Hz
MIN. 5x2,5 mm
2
3N400V ~50Hz
MIN. 5x4 mm
2
MIN. 6x0,5 mm
2
1 2 3 4 5 6 7
MU-CA 150 RN-12
MU-CA 150 RN-9
R3 230V 2000WR3 230V 2000W
R3 230V 2000WR3 230V 2000W
R2 230V 2000WR2 230V 2000W
R2 230V 2000WR2 230V 2000W
R1 230V 2000WR1 230V 2000W
R1 230V 2000W
R1 230V 2000W
T3T3
T3T3
L3
L3
L3L3
A1
A1
A1A1
A2
A2
A2A2
Kw1Kw1
Kw2Kw2
T2T2
T2T2
L2L2
L2L2
T1T1
T1T1
L1
L1
L1L1
N
L3
L2
L1
1
2 3
4
5
6
7
1 2 3 4
5 8
7
MIN. 6x0,5 mm
2
N
L3
L2
L1
1
2
3
4
5
6
7
Fig. 6
Fig. 6
12
3N400V ~50Hz
MIN. 5x6 mm
2
MIN. 6x0,5 mm
2
MU-CA 200 RN-18
R3 230V 3000W
R2 230V 3000W
R1 230V 3000W
R3 230V 3000W
R2 230V 3000W
R1 230V 3000W
R3 230V 3000W
R2 230V 3000W
R1 230V 3000W
R3 230V 3000W
R2 230V 3000W
R1 230V 3000W
T3T3
T3
T3
L3
L3
L3
L3
A1
A1
A1A1
A2
A2
A2
A2
Kw1
Kw1
Kw2
Kw2
T2
T2
T2
T2
L2
L2
L2
L2
T1
T1
T1
T1
L1
L1
L1
L1
N
N
L3
L3
L2
L2
L1
L1
1
1
2
2
3
3
4
4
5
5
6
6
7
7
1 2 3 4
5
8
7
Fig. 6
Fig. 7
15
ENGLISH
ENGLISH
Except for the MU-CA 100 AN, MU-CA 150 AN, MU-CA 200 AN that can only be used as an Air
Curtain with fresh air, the rest of models on this range have the option of working either with fresh or
warm air.
We advise you to check that the unit is in perfect condition when unpacking it, as any manu-
facturing or quality defect is covered by the guarantee.
IMPORTANT: SAFETY GUIDELINES
The appliance must not be right above or below a socket.
Do not cover the unit with clothes or objects that may obstruct the airflow and cause overheating.
While in operation, the connection cable must not be in front of the air outlet.
If it is installed in the bathroom, it must be placed so that the switches or other devices of com-
mand cannot be touched for a person that be in the bathtub or shower.
There must not be any inflammable objects at less than 50 cm from the unit (such as window
curtains, etc.). Keep the inlet and outlet grilles clean. When cleaning them, disconnect the unit
from the main supply.
Do not manipulate the unit with wet hands.
The installation work must be carried out by an electrician.
IMPORTANT: THIS APPLIANCE MUST BE EARTHED.
The means of disconnection from the mains supply must have an opening distance of at least
3 mm in all poles.
To operate the unit as an Air Curtain, the maximum distance to the floor must not be greater than 3 m.
The minimum distance between the Air Curtain and the floor must be 1,8 m.
INSTALLATION
The unit must be fixed to a convenient surface, and the minimum distances shown on Fig. 1
must be kept.
To install the unit, proceed as follows:
If the spiral nuts already placed in the device are used, there must be marked the centers of
the screws (M-8) according to the table of Fig. 2 (a) and Fig. 2 (b). If the hanging fixation is used,
the centers must be marked according to the table of Fig. 3 (a) and Fig. 3 (b) and place the
screws (D) and the set squares (E). Then hang the device and to fix on the lowest part with the
screw (G).
When the included wall bracket kit is used Fig. 4 (2 pcs. for 100 models and 3 pcs. for 150/200
models) set the support (L) to the back part of the curtain with the screws provided (I). Fix the
brackets (J) to the wall to match with the brackets on the curtain (L). See dimensions Fig. 3 (a)
and Fig 3 (b). Then hang the device and fix on the lowest part with the screw (K).
ELECTRICAL CONNECTION (Fig. 5)
The MU-CA Air Curtains are installed appliances. When installing these air curtains, the stand-
ards and regulations in force in your country must be followed strictly adhered to. Within the
installation an electrical isolation switch must be present, to enable the installer to cut all sup-
ply lines.
Connect the unit to the mains supply, checking that the voltage and frequency are the same as
those indicated on the electrical rating plate. Use the cables with the number of wires and sec-
tions as indicated on the wiring diagram for every model.
ENGLISH
16
ENGLISH
The connection can be made either through the back or by the side of the units. In case of
connection by the side, the lid of the connections must be mounted through the cable before
carrying the connections.
Fix the cable with the clamp provided and mount the front cover.
OPERATION
REMOTE CONTROL CONNECTION
(This control is incorporated in the packaging of each air curtain)
CURTAIN MODEL REMOTE CONTROL MODEL
MU-CA 100 AN
MUCR-AMU-CA 150 AN
MU-CA 200 AN
MU-CA 100 RN-3,5 MUCR-3,5 N
MU-CA 100 RN-6
MUCR-6/9
MU-CA 100 RN-9
MU-CA 150 RN-9
MU-CA 150 RN-12
MU-CA 200 RN-18
IF CONNECTION BETWEN TWO OR MORE AIR CURTAINS OF THE SAME MODEL (MAX. 5
UNITS), PLEASE REFER TO WIRING DIAGRAM FROM Fig. 6.
NOTE: In the case of multiple connection, Installer must consider the increased number of
feeders based on the number of connected units. In order to interconnect two or more cur-
tains it is predicted that the cables can go through their interior. Fig. 7 shows a lateral cover on
which a noticeable circular opening is present. This opening allows easy breakage, thus ena-
bling the installer to feed cables to the unit.
PROTECTION AGAINST OVERHEATING
The MU-CA Air Curtains are fitted with one thermal fuse which automatically disconnects the
unit in case of overheating.
In the event of this happening please contact the official dealer in your area.
MAINTENANCE
The MU-CA Air Curtains do not need any special maintenance, but it is recommended to keep
the inlet and outlet grilles clean. Clean them with a dry cloth (avoid using solvents or abrasive
detergents). Once a year, the inside parts should be cleaned by a qualified electrician using
compressed air or a vacuum cleaner. Disconnect the unit from the mains supply before carry-
ing out this operation.
AFTER SALES SERVICE
In case of any problem with the unit, it is advised to contact your dealer. Any manipulation
of the appliance by personnel not appointed by will cancel the guarantee.
reserves the right to modify the product without prior notice.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20

mundoclima Series MU-CA “Superficial Air Curtain” Installation guide

Type
Installation guide

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI