Assembly Instructions
Sufficient PTFE tape must be applied to valve-tail threads prior to
their installation. Silicone thread sealant should be applied to all threaded
components manufactured with ‘O-rings’.
Fit valve tails, using correct size Allen key. Accurately mark out bracket
holes on wall.
Drill 10mm diameter holes in wall to a minimum depth of 65mm and insert
wall plugs (B).
Attach brackets (C) to wall with screws (D) as shown and level. Tightly
fix the radiator tubes into the upper clamp assemblies (E). Loosely fit the
lower clamp assemblies (E) to the radiator.
Lift the radiator on to the wall and locate the upper clamp assemblies (E)
into the slots in the upper brackets (B).
Slide the lower clamp assemblies (E) until they locate in the slots in the
lower brackets (B) and tighten clamps.
Fix security clip (F) into position over upper clamps (E). Security clips
must always be placed in the top left and top right brackets when
mounting the radiator.
Due to the unique flow diverter built within all column radiators the flow
MUST be on the same side as the permanent blank which is diagonally
opposite to the air vent bleed valve.
This radiator should be installed onto a central heating system that has been
cleaned/flushed and contains water treatment and inhibitors in accordance
with BS7593.
Key Component Quantity
A Air Vent - 1/2” (factory fitted) 1
B Wall Plug* 4
C Bracket 4
D Screw - Hex Head* 4
E Clamp Assembly 4
F Security Clip 2
* Wall plugs and screws not supplied
This manual is a guide to the installation and maintenance of this column radiator. Please register within 30 days in order to
qualify for your warranty. The radiator must be installed in accordance with BS7593 and to the recognised water treatment procedures
and standards. Failure to correctly dose the heating circuit can cause the radiator to corrode immediately and will negate the warranty.
The system should be tested with the annual service and details can be entered on this document. All images and details contained are
subject to change and should be checked before installation.
Clamp Assembly (E) Security Clip (F) Bracket (C)
4 x BH
Height up to 1.5m, max 20 sections
1.5m+, max 10 sections
2 x 4 x CVD
6 x BH
Height up to 1.5m, >20 sections
1.5m+, >10 sections
2 x 6 x CVD
Tools & Material Required
Wall plugs - 10mm
Screws - 7mm diameter x 60mm length
Suitable valves
PTFE tape
Silicone thread sealant
Tape measure
Allen key - 13mm - 14mm
Socket driver - 10mm long reach
Electric drill
Masonry drill bit - 10mm diameter
Spirit level
Scan this
QR Code to
register your
warranty.
F R
All dimensions shown are in millimetres
Test pressure: 15 BAR
Max working pressure: 10 BAR
Max working temperature: 110º C
All steel construction: dia 25mm tubes
Connections: 1/2 inch BSP btm opp end tappings
Not suitable for use on domestic hot water system
Heat output determined in accordance with EN 442
Test Laboratory: WSP-LAB, Test Lab Registration No: 1428
Dimensions, Bracket and Security Clip Positions
P1 P2
2 column D1 54 59
D2 85 90
3 column D1 73 78
D2 123 128
4 column D1 91 96
D2 159 164
Min 65 Min 110
Column
www.acova.co.uk
Radiator
Model: 4030-22-SE
ISO9001
ISO14001
!
CAUTION HEAVY LOAD
CUSTOMERS SHOULD SEEK
ASSISTANCE FROM STAFF TO
LIFT ITEM
5
YEAR
Guarantee
5
Y
E
A
R
G
U
A
R
A
N
T
E
E
5
Y
E
A
R
G
U
A
R
A
N
T
E
E
5
Y
E
A
R
G
U
A
R
A
N
T
E
E
5
Y
E
A
R
G
U
A
R
A
N
T
E
E
5
Y
E
A
R
G
U
A
R
A
N
T
E
E
59
90
62
R
128 164
3 column 4 column
2 column
33 (29 for 2 column)
width
62
R
78 96
100 136
128 164
3 column 4 column
2 column
33 (29 for 2 column)
width
62
D2 D2
D1 D1 D1
=Security Clip
*
*=Security Clip
*
*
59
90
62
78 96
100 136
128 164
3 column 4 column2 column
33 (29 for 2 column)
width
height
width
pipe centres
= width + valves
* *
59
90
62
2 column
33 (29 for 2 column)
height
width
pipe centres
= width + valves
59
90
62
2 column
33 (29 for 2 column)
width
height
width
pipe centres
= width + valves
2 column
33 (29 for 2 column)
height
width
pipe centres
= width + valves
*
width
pipe centres
59
90
62
78 96
100 136
128 164
3 column 4 column2 column
33 (29 for 2 column)
width
height
width
= width + valves
D2
100 136
105105 105 105
1/2 1/2
Min 65 Min 110
*
P2
P1
ISO9001
ISO14001
ISO50001
=Diverter
=Air Vent
V0722 Acova Column Radiator Instructions
/