LP 29915 Operating instructions

Type
Operating instructions

LP 29915 is a versatile and durable oriented strand board (OSB) panel with a fire-resistant coating, designed for use in roof, wall, and subfloor systems. It offers superior fire protection, meeting the requirements of a Class A Flame Spread Rated material. With its strong and stiff structure, LP 29915 provides excellent racking strength, making it suitable for corner bracing applications. The panels are easy to install, requiring conventional nailing techniques, and can be sawn, routed, or drilled using standard woodworking tools.

LP 29915 is a versatile and durable oriented strand board (OSB) panel with a fire-resistant coating, designed for use in roof, wall, and subfloor systems. It offers superior fire protection, meeting the requirements of a Class A Flame Spread Rated material. With its strong and stiff structure, LP 29915 provides excellent racking strength, making it suitable for corner bracing applications. The panels are easy to install, requiring conventional nailing techniques, and can be sawn, routed, or drilled using standard woodworking tools.

S
• LPFlameBlockFire-RatedOSBSheathingpanelsaremadeof
orientedstrandboard(OSB)withafire-resistant,cementitious
coating(Pyrotite
TM
)bondedtooneorbothsides.Thecoating
consistsofahighlyhydrated,magnesiumoxychloridecement
reinforcedwithfiberglass.TheLPOSBsubstrateismanufactured
tobeconsistentandfreeofknots,graindefects,corevoids,splits
andotherirregularities.Thewoodstrandsaremixedwithresins,
arrangedinlayersforstrengthandstabilityandbondedunder
heatandpressure.Thepanelsaresealedonallfouredgesfor
addedmoistureresistanceanddimensionalstability.
• LPFlameBlockFire-RatedOSBSheathingroofpanelshavea
coarse-texturedtopsurfacethathelpsprovidesafefootingon
pitchedroofs.
• Thepanelsshouldbefastenedwithconventionalnailing
techniques.Consultyourlocalbuildingauthoritiesregarding
acceptabilityoffasteningstechniques.
• Thepanelsmaybesawncleanly,andmayberoutedordrilledwith
standardwoodworkingtools.
• LPFlameBlockFire-RatedOSBSheathingpanelsarefabricated
instandard3ft.11-7/8in.x7ft.11-7/8in.size(productsare
undersized1/8in.toallowforproperspacingduringinstallation).
Extendedlengthpanelsareavailable.
LPFLAMEBLOCKFIRE-RATEDOSBSHEATHINGPANELSARE
NOTFORUNPROTECTEDEXTERIORUSE.Theymustbecov-
eredwithsidingpanelsorothertypesofexteriorwallcladding
orroofingmaterial.Normalexposuretoweatherduringordinary
constructiondelayswillnotdamagethepanels.ADDITIONAL
PROTECTIVEMEASURESARERECOMMENDEDFOREXTENDED
ADVERSEWEATHERCONDITIONS.EXCEPTION:Panelsidentified
asExposure1maybeusedforroofsheathingwhereexposedon
theunderside,suchasoneaves.Whenusedinthisapplication,
theundersideandanyexposededgesofpanelsmustbecoated
withexterior-gradepaint.
• Slightsurfaceflakingorthicknessswellcausedbymoisture
exposurewillnotaffectstructuralperformance.
• LPFlameBlockFire-RatedOSBSheathingpanelsarecertifiedto
meettherequirementsofaClassAFlameSpreadRatedmaterial
asdefinedinASTME-84(IntertekListing1532-4),aswellasClass
AandClassCroofdeckasdefinedinASTME-108(verifiedby
UnderwritersLaboratories).
• LPFlameBlockFire-RatedOSBSheathingisanapprovedcom-
ponentinfire-ratedwallassemblies.Findmoreinformationat
www.lpcorp.com/flameblockandinourICCEvaluationReport,
ESR-1365.
• LPFlameBlockFire-RatedOSBSheathingwallpanelsprovidesuf-
ficientrackingstrengthtomeetcornerbracingrequirements.
• Panelsarestiffandstrongandhavealowcoefficientoflineal
expansion.
• ForadditionaltechnicalandengineeringinformationandMaterial
SafetyDataSheets,contactyourLPsalesrepresentativeorvisit
www.lpcorp.com/flameblock.
LPproductsaremanufacturedinaccordancewiththecompany’s
policyonprotectionoftheenvironmentwhichincludes:
• Useofenvironmentalcontroltechnologyandenergyefficient
equipmenttoconserveresources.
• Useofwoodby-productstoproduceenergy,therebyconserving
nonrenewableresources.
•
UseofSFI®-certifiedforestmanagementandprocurementsystems,
whichhelpensurethatwoodcomesfromwell-managedforests.
• Efficientuseofrawmaterialtoproduceengineeredwoodprod-
uctsthatoffermoreconsistentperformanceandstrengththan
non-strand-basedproducts.
• Formoreinformation,seeourLPFlameBlockFire-RatedOSB
SheathingGreenBrief.
M  F
S
L
P P
E I
F P
S  H
• Storepanelsinclean,dryareasofftheground.Ifpossible,store
indoors.Ifstoredoutside,coverwithplasticsheets,tarpsorthe
LPFlameBlockFire-RatedOSBSheathingunitcover.Keepcover
openandawayfromthesidesandbottomofpanelstoallowfor
aircirculation.
• Additionalprotectivemeasuresmaybenecessaryduring
extendedadverseweatherconditions.
I - G R
• Complywithlocalsafetyregulationswheninstallingroof,wall,
orsubfloorsheathing.
• Complywiththefollowingmanufacturer’sinstructionsand
withAPA’sEngineeredWoodConstructionGuideFormE30U
(September2007)orthecurrentequivalent.
R I
• Placetheskid-resistantsideupwiththewhitefire-resistantsur-
facefacingdownandwearskid-resistantshoeswheninstalling
LPFlameBlockFire-RatedOSBSheathingasroofsheathingon
eithersideofapartitionwallinmulti-familyresidentialbuildings,
orinanyapplicationwherereducingthespreadrateofaninterior
fireistheintentofthecoderequirement.InstallLPFlameBlock
Fire-RatedOSBSheathingwiththewhitePyrotite
TM
sidefacing
upwardswhenusedunderEPDMroofmembranesandinother
applicationswherereducingthespreadrateoffirefromanexte-
riorsourceistheintent.
S (.)
LPFlameBlockFire-RatedOSBSheathingpanelscomplywiththe
followingindustrystandardsandcertifications:
•
LPFlameBlockFire-RatedOSBSheathing
panelsarecertifiedto
complywithU.S.VoluntaryProductStandardPS2,whichisrecog-
nizedintheUniformBuildingCode,theInternational-BuildingCode
andtheInternationalResidentialCode,andbyInternationalCode
CouncilEvaluationservice(ICC-ES)EvaluationReportESR-1365.
LPFlameBlockFire-RatedOSBSheathingpanelsaredesignedfor
useinroof,wallandsubfloorsystemsincommercialandresidential
projects,maintenance,remodelingornewconstruction.
P D
S  C
LP® FlameBlock® Fire-Rated Sheathing
• Installwiththelongdimensionorstrengthaxisofthepanel
acrosssupportsandwiththepanelcontinuousovertwoor
morespans.
• Provide1/8in.spaceatpanelendsandedges.Useaspacertool
(i.e.10dboxnail)toensureaccurateandconsistentspacing.
• Panelendjointsshalloccuroverframing.Staggerendjointsin
eachsucceedingrow.
• Forpanelsinthe7/16and15/32category,provideadditional
panelstiffnessbyinstallingpaneledgeclipsmid-spanonall
un-supportededges.
• Nail6in.o.c.alongsupportedpanelendsandedgesand12in.
o.c.atintermediatesupports.Fastenpanels3/8in.frompanel
edges.Use8dcommonnailsforpanelsupto1in.thickness.
Forpanelsover1in.use8dring-shankor10dcommonnails.
Othercode-approvedfastenersmaybeused.
• Coverroofsheathingassoonaspossiblewithroofingfeltor
shingleunderlaymentforprotectionagainstexcessivemois-
turepriortoroofing.Ifanyedgeswellingoccurspriortoroof
underlaymentinstallation,theexposedwoodsubstratesideof
panelswithraisedjointsshouldbesandedflat.
• Removewrinklesandflattensurfaceofshingleunderlayment
beforeinstallingshingles.Highperformanceshingleunderlay-
mentisrecommendedforbetterresults.
• Heavierweightand/ortexturedshinglesarerecommendedto
bettermaskimperfectionsinroofingassembly.
• Wheninstalledasroofdeckinopeneaves,theexposedunder-
sideofpanels,aswellasanyexposededges,mustbecoated
withexterior-gradepaint.
NOTE:Checkwithyourlocalbuildingdepartmentbeforedeciding
onaninstallationmethod.
W I
• LPFlameBlockFire-RatedOSBSheathingpanelsshouldbe
installedasspecifiedintherelevantfire-ratedassembly.In
theabsenceofalistedfire-ratedassembly,panelsshouldbe
installedvertically,withthehorizontaljointsblocked.
• WheninstallingLPFlameBlockFire-RatedOSBSheathingin
walls,consultapprovedconstructionplanstodeterminethe
properorientationofthewhite,fire-resistantpanelsurface.
• Provide1/8in.spacebetweenpanelendsandedges.Usea
spacertool(i.e.10dboxnail)toensureaccurateandconsistent
spacing.
• Atminimum,nail6in.o.c.alongsupportedpanelendsand
edgesand12in.o.c.atintermediatesupports.Fastenpanels
3/8in.frompaneledges.Use6dcommonnailsforpanelsup
to1in.thickness.Forpanelsover1in.use8dring-shankor8d
commonnails.Othercode-approvedfastenersmaybeused.
Foradditionalfasteningrequirements,refertoFigure3.NOTE:
Forshearwalls,usethefastenertypeandspacingspecifiedin
approvedconstructiondocuments.
• StructuralperformanceisverifiedbyProgressiveEngineering,
Inc.(Report,PER-06013),www.p-e-i.com.
• FireperformanceisverifiedbyOmegaPoint/Intertek(listing
1532-4).Directorycanbereferencedatwww.opl.com.
FIGURE 1. RECOMMENDED UNIFORM ROOF LIVE LOADS FOR LP FLAMEBLOCK FIRE-RATED SHEATHING
(c)
AND RATED
SUBFLOOR WITH STRENGTH AXIS PERPENDICULAR TO SUPPORTS
(c)
Panel Span Performance Maximum Span (in.) Allowable Live Loads (psf)
(b)
Rating Category** With Edge Support (a) Without Edge Support Spacing of Supports Center-to-Center (in.)
Rated Sheathing
(c)
12 16 20 24 32 40 48 60
24/16 7/16 24 24 190 100 65 40
32/16 15/32,1/2 32 28 325 180 120 94 30
40/20 19/32,5/8 40 32 - 305 205 151 60 30
48/24 23/32,3/4 48 36 - - 280 175 95 45 35
60/32 7/8 60 40 - - - 305 165 100 70 35
60/48 1-1/8 60 48 - - - 305 165 100 70 35
Rated Subfloor
(c)
12 16 20 24 32 40 48 60
16oc 19/32,5/8 24 24 185 100 65 40
20oc 19/32,5/8 32 32 270 150 100 60 30
24oc 23/32,3/4 48 36 - 240 160 100 50 30 25
32oc 7/8 48 40 - - 295 185 100 60 40
48oc 1-3/32,1-1/8 60 48 - - - 290 160 100 65 40
(c)Appliestopanels24in.orwiderappliedovertwoormorespans.
*Noestablishedtolerance.
**PerformanceCategoryreplacesthefractionalnominalthicknessusedinPS2
andisconsistentwiththepanelthicknessusedintheU.S.modelbuildingcodes.
(a)Tongueandgrooveedges,paneledgeclips(onemidway*betweeneachsupport,
excepttwoequallyspacedbetweensupports48in.oncenterorgreater),lumber
blocking,orother.
(b)10psfdeadloadassumed
• LPFlameBlockFire-RatedStructural1Sheathingpanelshavesupe-
riormaximumliveloadoverstandardOSBwheninstalledwiththe
longaxisparalleltothestructuralsupports.
LP
®
FlameBlock
®
Fire-Rated Structural 1 Sheathing
• LPFlameBlockFire-RatedStructural1Sheathingpanelsare
designedtoperformasroof,sidewallandfloorsystems,where
highwindorearthquakeconditionsmayoccur.
• LPFlameBlockFire-RatedStructural1Sheathingpanelsare
equallysuitedforpitchedorflatroofapplications.
• LPFlameBlockFire-RatedStructural1Sheathingpanelscanbe
usedincommercialandresidentialprojects,suchasindustrial
buildings,mobileandmodularhomeconstructionorinany
applicationrequiringhighstrength,superiorshearvalues,
andfireresistance.
LPFlameBlockFire-RatedOSBSheathingpanelscomplywiththe
followingindustrystandardsandcertifications:
•
LPFlameBlockFire-RatedOSBSheathing
panelsarecertifiedto
complywithU.S.VoluntaryProductStandardPS2,whichisrecog-
nizedintheUniformBuildingCode,theInternational-BuildingCode
andtheInternationalResidentialCode,andbyInternationalCode
CouncilEvaluationService(ICC-ES)EvaluationReport/ESR-1365.
• StructuralperformanceisverifiedbyProgressiveEngineering,Inc.
(Report,PER-06013),www.p-e-i.com.
• FireperformanceisverifiedbyOmegaPoint/Intertek
(listing1532-4).Directorycanbereferencedatwww.opl.com.
P D
S  C
Figure 2. LP FlameBlock Structural 1 Rated Sheathing Roof
Panels Parallel to Supports
Performance Category Span Rating Max. Live Load for Roofs (lbs)**
7/16 24/16 40
15/32 32/16 70
1/2 32/16 70
**Liveloadfor24in.o.c.spanconditions.10psfdeadloadassumed.
A
Call LP customer service or visit our web site for more information
on OSB structural panels and other LP products.
Customer Service: 888.820.0325 www.lpcorp.com
Sales Office:
Nashville, TN 800.964.6310
• LPFlameBlockFire-RatedOSBSheathingpanelsareavail-
abledirectlyfromLPbyrailcar,aswellaspiggybackand
truckloadshipment.
S (.)
S (cont.)
Panels Applied Over
Panels Applied Direct to Framing 1/2” or 5/8” Gypsum Sheathing
Panel Performance Minimum
Grade Category** Nail Nail Size Nail Spacing Nail Size Nail Spacing
Penetration (Common or at Panel Edge (in.) (common or at Panel Edges (in.)
in Framing Galvanized Box) Galvanized
(in.) 6 4 3 2
(e)
Box) 6 4 3 2
(e)(d)
7/16
1-3/8 8d
255 395 505 670
(c)
10d 280 430 550(e) 730
15/32 280 430 550 730
15/32 1-1/2 10d 340 510 665
(e)
870 — — —
7/16
1-3/8 8d
240 350 450 585
(c)
10d 260 380 490
(e)
640
15/32 260 380 490 640
15/32 310 460 600
(e)
770 — — —
5/8
1-1/2 10d
340 510 665
(e)
870 — — —
FIGURE 3. ALLOWABLE SHEAR (POUNDS PER FOOT) FOR PANEL SHEAR WALLS WITH FRAMING OF DOUGLAS-FIR, LARCH, OR SOUTHERN
PINE
(a)
OR WIND OR SEISMIC LOADING
(b,f, g, h, i)
(See also 2006 IBC Table 2306.4.1)
(a) Forframingofotherspecies:(1)FindspecificgravityforspeciesoflumberintheAF&PANationalDesignSpecification.(2)Forcommonorgalvanizedboxnails,
findshearvaluefromtableabovefornailsizeforactualgrade.(3)Multiplyvaluebythefollowingadjustmentfactor:SpecificGravityAdjustmentFactor=[1-(0.5
-SG)],whereSG=specificgravityoftheframing.Thisadjustmentshallnotbegreaterthan1.***
(b) Allpaneledgesbackedwith2-in.nominalorwiderframing.Installpanelseitherhorizontallyorvertically.Spacenailsmaximum6in.o.c.alongintermediate
framingmembersfor3/8Categoryand7/16Categorypanelsinstalledonstudsspaced24in.o.c.Forotherconditionsandpanelthicknesses,spacenailsmaxi-
mum12in.o.c.onintermediatesupports.Fastenersshallbelocated3/8in.frompaneledges.***
(c) Allowableshearvaluesarepermittedtobeincreasedtovaluesshownfor15/32categorysheathingwithsamenailingprovided(1)studsarespacedamaximumof
16in.o.c.,or(2)panelsareappliedwithlongdimensionacrossstuds.***
(d) Framingatadjoiningpaneledgesshallbe3-in.nominalorwider,andnailsshallbestaggeredwherenailsarespaced2in.o.c.Checklocalcodeforvariationsof
theserequirements.***
(e) Framingatadjoiningpaneledgesshallbe3-in.nominalorwider,andnailsshallbestaggeredwhere10dnails(3in.x0.148in.)havingpenetrationintoframingof
morethan1-1/2in.arespaced3incheso.c.Checklocalcodeforvariationsoftheserequirements.***
(f) Wherepanelsareappliedonbothfacesofawallandnailspacingislessthan6in.o.c.oneitherside,paneljointsshouldbeoffsettofallondifferentframing
members.Orframingshallbe3in.nominalorthickerandnailsoneachsideshouldbestaggered.***
(g) InSeismicDesignCategoryD,E,orF,wheresheardesignvaluesexceed350poundsperlinealfoot,allframingmembersreceivingedgenailingfromabutting
paneledgesshallnotbelessthanasingle3-in.nominalmember,ortwo2-in.nominalmembersfastenedtogetherinaccordancewith2006IBCSection2306.1to
transferthedesignshearvaluebetweenframingmembers.Woodstructuralpaneljointandsillplatenailingshallbestaggeredinallcases.See2006IBCSection
2305.311forsillplatesizeandanchoragerequirements.***
(h) Galvanizednailsshouldbehotdippedortumbled.***
(i) ForshearloadsofnormalorpermanentloaddurationasdefinedbytheAF&PANDS,thevaluesinthetableaboveshouldbemultipliedby0.63or0.56
respectively.***
**PerformanceCategoryreplacesthefractionalnominalthicknessusedinPS2.
***TypicalLayoutforShearWallstable
Structural 1
Grades
Rated
Sheathing
S (.)
FIGURE 4. ALLOWABLE SHEAR (POUNDS PER FOOT) FOR HORIZONTAL LP PANEL DIAPHRAGMS WITH FRAMING OF DOUGLAS-FIR,
LARCH OR SOUTHERN PINE
(a)
FOR WIND OR SEISMIC LOADING
(b)
(See also IBC Table 2306.1)
Nail Spacing (in.) at Other Panel Edges
(Cases 1, 2, 3 & 4)
(c)
(a) Forframingofotherspecies:(1)FindspecificgravityforspeciesoflumberintheAFPANationalDesignSpecification(2)Findshearvaluefromtableabovefor
nailsizeforactualgrade(3)Multiplyvaluebythefollowingadjustmentfactor:SpecificGravityAdjustmentFactor=[1-(0.5–SG)],whereSG=specificgravityof
theframing.Thisadjustmentshallnotbegreaterthan1.
(b) ForshearloadsofnormalorpermanentloaddurationasdefinedbytheAF&PANDS,thevaluesinthetableaboveshouldbemultipliedby0.63or0.56,
respectively.
(c) Spacenailsmaximum12in.o.c.alongintermediateframingmembers(6in.o.c.whensupportsarespaced48in.o.c.orgreater).Fastenersshallbelocated
3/8in.frompaneledges.
(d) Framingatadjoiningpaneledgesshallbe3in.nominalorwider,andnailsshouldbestaggeredwherenailsarespaced2in.o.c.or2-1/2in.o.c.
(e) Theminimumnormalwidthofframingmembersnotlocatedatboundariesoradjoiningpaneledgesshouldbe2in.
(f) 8disrecommendedminimumforroofsduetonegativepressuresofhighwinds.
(g) Framingatadjoiningpaneledgesshouldbe3in.nominalorwider,andnailsshouldbestaggeredwhere10dnailshavingpenetrationintoframingofmorethan
1-1/2in.arespaced3incheso.c.
Note: Designfordiaphragmstressesdependsondirectionofcontinuouspaneljointswithreferencetoload,notondirectionoflongdimensionorstrengthaxisof
sheet.Continuousframingmaybeineitherdirectionforblockeddiaphragms.
**PerformanceCategoryreplacesthefractionalnominalthicknessusedinPS2.
Minimum
Nominal Width
of Framing
Members at
Adjoining Panel
Edges and
Boundaries
(e)
(in.)
2
3
2
3
2
3
2
3
2
3
Panel
Grade
LP
Structural 1
Grades
LP Rated
Sheathing
Common
Nail Size
10d
(g
8d
(f)
10d
(g)
Minimum
Nail
Penetration
in Framing
(in.)
1-1/2
1-3/8
1-1/2
Performance
Category**
15/32
7/16
15/32
15/32
5/8
320
360
255
285
270
300
290
325
320
360
Blocked Diaphragms
Nail Spacing (in.) at diaphragm boundaries
(all cases), at continuous Panel edges
parallel To load (Cases 3 & 4),
And at all panel Edges (Cases 5 & 6)
(c)
6 4 2-1/2
(d)
2
(d)
Unblocked Diaphragms
Nails Spaced 6” max at
Supported Edges
(c)
Case 1 (No
unblocked
edges or
continuous
joints paral-
lel to load)
285
320
230
255
240
265
255
290
285
320
All other
Configurations
(Case 2, 3, 4,
5 & 6)
215
240
170
190
180
200
190
215
215
240
425
480
340
380
360
400
385
430
425
480
640
720
505
570
530
600
575
650
640
720
730
820
575
645
600
675
655
735
730
820
© 2011 Louisiana-Pacific Corporation. LP is a registered trademark of Louisiana-Pacific Corporation. APA and Struc 1 are registered trademarks of APA – The Engineered Wood Association.
Pyrotite is a registered trademark of Barrier Technology Corporation. All rights reserved. Printed in USA. Specifications subject to change without notice. LPFB0017
Cal. Prop 65 Warning: Use of this product may result in exposure to wood dust, known to the State of California to cause cancer.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5

LP 29915 Operating instructions

Type
Operating instructions

LP 29915 is a versatile and durable oriented strand board (OSB) panel with a fire-resistant coating, designed for use in roof, wall, and subfloor systems. It offers superior fire protection, meeting the requirements of a Class A Flame Spread Rated material. With its strong and stiff structure, LP 29915 provides excellent racking strength, making it suitable for corner bracing applications. The panels are easy to install, requiring conventional nailing techniques, and can be sawn, routed, or drilled using standard woodworking tools.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI