CPU Core/Bus Ratio Selection
(DIP Switch 1)
To protect the system and components, it is essential that you reinstall the top panel after you have finished working on the system.
Due to the fact that adequate air flow and
proper thermal control are very critical in
maintaining 1U system's stability and
performance, it is imperative that the proper
installation procedures listed below be
followed in order to maximize system
performance. This is especially critical for 1U
Dual Processor Servers with speeds of 1
GHz and above.
Warning !
CPU Heat Sink Installation Procedures
(For Supermicro SuperServer 1U Systems)
1) Only those CPU heat sinks that are provided by Supermicro should be used.
2) Apply proper amount of silicon compound on the CPU's die.
3) Place the CPU heat sink on top of the CPU.
4) Place the heat sink spring on top of the CPU heat sink and lock the backside of the spring into its notch.
5) Lock the front side of the heat sink spring into its notch.
= >
CPU
400/533
450/600
500/666
550/733
600-800
650-866
700/933
750/1000
800/1064
850/1130
900/1200
SW1
#1
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
SW1
#2
ON
ON
OFF
OFF
ON
ON
OFF
OFF
ON
ON
OFF
SW1
#3
OFF
OFF
OFF
OFF
ON
ON
ON
ON
OFF
OFF
OFF
SW1
#4
ON
ON
ON
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
1 2 3 4 5
Cooling Fan Installation
Rear Panel Functions
1. AC Power connector
2. PS/2 Mouse and Keyboard port
3. 2 USB ports
4. 2 COM ports ( 1 internal)
5. 1 VGA port
6. 2 x Intel 82559 LAN port
7. 64/32-bit Expansion slot
8. PCI Card Release Latch
1
2
3
4
5
6
7
8