American Standard 2422.068C.222 Installation guide

Category
Air blowers/dryers
Type
Installation guide
754072-100 Rev. A
1
THANK YOU...
for selecting an American Standard bath. Your new bath is shipped to you after careful inspection. The air bath is
completely assembled with air blower and system piping. All you need to finish the installation are your selected
fittings and electrical connections.
To ensure maximum performance and pleasure from this product, please follow the instructions and cautions.
MODEL 2422L.068C 5' x 32"
2422V.068C
MODEL 2771L.068C 5' x 36"
2771V.068C
MODEL 2645L.068C OVAL
2645V.068C
MODEL 7236L.068C 6' x 36"
7236V.068C
MODEL 2425L.168C 5' x 32" IA-RHO
2425V.168C
MODEL 2425L.268C 5' x 32" IA-LHO
2425V.268C
© AS Americas Inc. 2010
All product names listed herein are trademarks
of AS Americas Inc. unless otherwise noted.
FOR AFTER-SALES SERVICE CALL 1 (800) 442-1902 WEEKDAYS.
INSTALLATION AND OPERATION MANUAL
FOR EVERCLEAN
/EVOLUTION
AIR BATHS
2
754072-100 Rev. A
TABLE OF CONTENTS:
Safety Instructions............................................................................Page 3
General Information..........................................................................Page 4
Optional Components.......................................................................Page 4
Specifications....................................................................................Page 5
Roughing-in Reference.....................................................................Page 6
Framing and Support Instructions.....................................................Page 7
Mounting Instructions........................................................................Page 8
Electrical Connections.......................................................................Page 9
Remote Blower Location Option........................................................Page 10
Post Installation Clean-up..................................................................Page 11
Operation: Air Bath.............................................................. ..............Page 12
Cleaning and Maintenence................................................................Page 13
Warranty............................................................................................Page 14
754072-100 Rev. A
3
!
!
!
!
!
!
!
SAVE THESE INSTRUCTIONS
WARNING:
Risk of personal injury.
Do not permit children to use this unit without adult supervision.
WARNING: Risk of personal injury. Do not operate this unit without the guard over the suction fitting.
WARNING: Risk of electric shock. Do not permit electrical appliances (hair dryer, telephone, radio, etc.) within
60 inches (1524mm) of this unit.
WARNING: Risk of hyperthermia and possible drowning. People using medications and/or having adverse
medical history should consult a physician before using this product.
WARNING: Risk of personal injury. Do not overfill unit before entering. Entering tub when filled more than 2/3
can cause overflow and slippery conditions. Exercise caution when entering and exiting.
WARNING: No Food or Alcoholic Beverages. Use of your bathtub immediately after meals is not
recommended. Avoid alcohol consumption before or during bathing. Alcoholic beverages can cause drowsiness or
hyperthermia resulting in loss of consciousness or even drowning.
WARNING:
Pregnancy.
If you are or think you may be pregnant, consult your physician before using the bathtub.
Never drop or insert any object into any opening.
Use this unit only for its intended use as described in this manual. Do not use any attachments not recommended by
American Standard.
The unit must be connected only to a supply circuit that is properly protected by a ground-fault circuit-interrupter
(GFCI). Such a GFCI should be provided by the installer and should be tested on a routine basis. To test the GFCI,
push the test button. The GFCI should interrupt power. Push the reset button. Power should be restored. If the GFCI
fails to operate in this manner, the GFCI is defective. If the GFCI interrupts power to the bathtub without the test button
being pushed, a ground current is flowing, indicating the possibility of an electric shock. Do not use this air bath.
Disconnect the air bath and have the problem corrected by a licensed electrician before using.
IMPORTANT SAFETY
INSTRUCTIONS
INSTRUCTIONS PERTAINING TO
A RISK OF FIRE, ELECTRIC SHOCK
OR INJURY TO PERSONS
READ AND FOLLOW ALL INSTRUCTIONS!
4
754072-100 Rev. A
Everclean
/ Evolution
5' x 32"
Everclean
/ Evolution
5' x 36"
Everclean
/ Evolution
6' x 36"
Everclean
/ Evolution
Oval
2422L / V.068C
2771L / V.068C
7236L / V.068C
2425L / V.168C - RHO
2645L / V.068C
9261.019
9261.019
9271.019
9266.018
751755-100
751755-100
751755-100
751755-100
Optional Components
(Not Included)
Required Components
(Not Included)
Apron
Kit
Tile Bead
Kit
1599.205.XXX*
1599.205.XXX*
1599.205.XXX*
1583.470.XXX
Drain
(Specify Finish)
List of Required Tools and Supplies:
Tools
• Level
Tape Measure
• Pipe Wrench
• Slip Joint Pliers
• Screw Driver
• Standard Woodworking Tools
• Personal Safety Equipment
• Caulking Gun
Supplies
• Nails
• Putty
• Caulking (waterproof)
• 1 x 4 Stringers
• Drop Cloth
• Cement, Plaster, Grout
General Installation Information
Carefully uncrate and inspect your new bath for any shipping damage. If such damage is found, report it
to your vendor immediately. After inspection and during installation, protect the bath from construction
damage. Before installation, and before enclosing with wallboard, tile, etc., the bath must be filled
with water and operated to check for leaks that may have resulted from shipping damage or
mishandling! Do not make unauthorized modifications to the air bath system. This could adversely affect
the safety and performance of the air bath and void the warranty. Do not handle or move the air bath by
the air blower or piping system. Fittings (bath filler, shower arm, etc.) are not provided with the bath and
must be ordered separately. Framing and enclosing materials are provided by others.
For electrical requirements, refer to section titled Air Bath Electrical Installation Instructions”.
Check for availability of optional American Standard wall tiling bead (required for recess installation).
Protect all finished surfaces of the air bath during construction and installation using a drop cloth.
Description
Model Number
LIST OF OPTIONAL COMPONENTS (NOT INCLUDED):
* These models require American Standard Deep Soak Max Drain 1599.205
!
WARNING: Do not lift air bath by the piping harness at any time.
2425L / V.268C - LHO
NOT
APPLICABLE
INTEGRAL
1599.205.XXX*
Everclean
/ Evolution
5' x 32" IA
754072-100 Rev. A
5
SPECIFICATIONS:
GENERAL SPECIFICATIONS FOR EVOLUTION AIR BATHS
TABLE 1
SIDE VIEW
DRAIN / OVERFLOW
END VIEW
L
H
W
C
A
B
J
2422L / V.068C
5' x 32"
2771L / V.068C
5' x 36"
7236L / V.068C
6' x 36"
2425L / V.168C
IA-RHO
2425L / V.268C
IA-LHO
5' x 32
"
2645L / V.068C
Oval
A 20-1/8"
(511mm)
B 11"
(279mm)
A 20-1/8"
(511mm)
B 11"
(279mm)
A 20-1/8"
(511mm)
B 11"
(279mm)
A 19-1/8"
(485mm)
B 10-1/2"
(266mm)
A 15-1/4"
(387mm)
B 8-1/4"
(209mm)
3-1/4"
(83mm)
3-1/4"
(83mm)
3-1/4"
(83mm)
2-7/8"
(73mm)
1-3/4"
(44mm)
C 20"
(508mm)
C 20"
(508mm)
C 20"
(508mm)
C 20-1/4"
(515mm)
C 18-1/4"
(464mm)
58-1/2"
(1485mm)
x
30-1/2"
(774mm)
58-1/2"
(1485mm)
x
34-1/2"
(876mm)
70-1/2"
(1790mm)
x
34-1/2"
(876mm)
N/D
64"
(1625mm)
x
34"
(863mm)
60-3/16"
(1528mm)
x
30-1/2"
(774mm)
60-3/16"
(1528mm)
x
34-1/2"
(876mm)
72-3/16"
(1833mm)
x
34-1/2"
(876mm)
60-3/16"
(1528mm)
x
30-1/2"
(774mm)
66-3/16"
(1681mm)
x
34-1/2"
(876mm)
L 60" (1524mm)
W 32" (813mm)
H 21-1/2" (546mm)
L 60" (1524mm)
W 36" (914mm )
H 21-1/2" (546mm)
L 72" (1829mm)
W 36" (914mm)
H 21-1/2" (546mm)
L 60" (1524mm)
W 32" (813mm)
H 20-1/2" (521mm)
L 66" (1676mm)
W 36" (914mm )
H 19-3/4" (502mm)
74 lb.
(34 kg.)
75 lb.
(34 kg.)
106 lb.
(48 kg.)
92 lb.
(42 kg.)
96 lb.
(44 kg.)
690lb (313kg)/
(260kg/sq.m)
53lb/sq.ft.
800lb (363kg)/
(260kg/sq.m)
53lb/sq.ft.
1031lb (467kg)/
(280kg/sq.m)
57lb/sq.ft.
675lb (306kg)/
(262kg/sq.m)
54lb/sq.ft.
580lb (263kg)/
(175kg/sq.m)
36lb/pies
cuadrados
Optional
Optional
Optional
Included
Optional
74 gal.
(280 l.)
87 gal.
(329 l.)
111 gal.
(420 l.)
70 gal.
(265 l.)
58 gal.
(219 l.)
Description Drain /
Overflow
Cut Out
Pier
G x F
Rough-In
Recess
E x D
Tub Edge to
Centerline
Overflow: J
Weight with
Water / Floor
Loading
Product
Weight
Apron /
Mounting
Gallon to
Overflow
Height to
Underside
of Deck: C
Dimensions
L-W-H
6
754072-100 Rev. A
DIMENSIONS OF FIXTURES ARE NOMINAL AND MAY VARY WITHIN THE RANGE
OF TOLERANCES ESTABLISHED BY ANSI STANDARDS Z124.1 AND A112.19.7.
ROUGHING-IN REFERENCES
5' x 32" (MODEL 2422L / V.068C)
5' x 32" IA-RHO (MODEL 2425L / V.168C-RHO)
5' x 32" IA-LHO (MODEL 2425L / V.268C-LHO) - shown
5' x 36" (MODEL 2771L / V.068C)
6' x 36" (MODEL 7236L / V.068C)
OVAL (MODEL 2645L / V.068C)
60"
(1524mm)
32"
(813mm)
11"
(279mm)
7-3/4"
(197mm)
13-3/4"
(349mm)
6"
(152mm)
3"
(76mm)
3-1/4"
(83mm)
CUT OUT IN FLOOR
FOR DRAIN
72"
(1829mm)
36"
(914mm)
7-3/4"
(197mm)
11"
(279mm)
3-1/4"
(83mm)
3"
(76mm)
6"
(152mm)
13-3/4"
(349mm)
CUT OUT IN FLOOR
FOR DRAIN
60"
(1524mm)
36"
(914mm)
3"
(76mm)
7-1/2"
(191mm)
6"
(152mm)
11"
(279mm)
13-3/4"
(349mm)
CUT OUT IN FLOOR
FOR DRAIN
3-1/4"
(83mm)
66"
(1676mm)
5-3/8"
(137mm)
6"
(152mm)
36"
(914mm)
8-1/4"
(210mm)
3"
(76mm)
11-1/4"
(286mm)
1-3/4"
(44mm)
18"
(457mm)
CUT OUT IN FLOOR
FOR DRAIN
CUT OUT IN FLOOR
FOR DRAIN
60"
(1524mm)
32"
(813mm)
7-1/2"
(191mm)
10-1/2"
(267mm)
3"
(76mm)
2-7/8"
(73mm)
6"
(152mm)
13-1/2"
(343mm)
16"
(406mm)
754072-100 Rev. A
7
INSTALLATION AND FRAMING INSTRUCTIONS
The variety of installations possible for this air bath may require framing procedures other than those shown. Locate studs as needed. Ensure
roughing-in dimensions are proper, plumb and square. Provisions must be made in all installations for an access opening for servicing the air
blower and controls. It is strongly recommended that an additional opening be provided for access to the drain components. The apron should not
be used as the primary access opening.
TYPICAL PIER TYPE INSTALLATION
AS DESIRED
F
CUTOUT
AS DESIRED
G
CUTOUT
C
24
(610 mm)
12
(305 mm)
MOUNTING
SURFACE
WATERPROOF
SEALANT
BATH
TYPICAL RECESS INSTALLATION
24
(610 mm)
12
(305 mm)
C
E
D
W
LEVELING
STRINGERS
TILE
TILE
BEAD
STRIP
LEVELING STRINGER
1 x 4 (not for support)
BATH
ADHESIVE
SEALANT
WALLBOARD
NOTE: Tile bead kit not included and
must be purchased separately.
C
TYPICAL INSTALLATION
FIGURE 1
This bath must be supported along its entire bottom. Use mortar as bedding
material (do not use sand or foam). Apply enough mortar to support the complete
bottom of the bath. After the mortar has been poured, and before it sets, position bath
within recess until the rim is leveled against the leveling stringers (see "Typical Recess
Installation") shown below.
The rim of the bath must not support weight. Allow the mortar material to completely
harden before applying weight to the rim or bottom of the bath. Any finish material such
as tile or wall board must be self-supporting if it contacts the deck of the bath.
Replace air bath and re-shim the integral support feet, shimming the entire length of the
support feet. Secure the shims using construction adhesive, silicone, mortar or
equivalent materials. While not a necessity, the use of a foundation base consisting of
cement, mortar, or grout will help provide a solid and secure installation.
3. Install drain components to the air bath following the drain installation instructions. Before
replacing your air bath for final installation, be certain that an opening has been provided in
the sub-floor for the drain. See the roughing-in drawing and Table 1 for suggested opening
size (shadowed) and location dimensions. The drain/overflow of the bath extends below the
bottom of the bath. Note that this requires a cutout in the floor.
The floor structure beneath the bath must be able to support a total weight of bath, water, and
bather. Refer to Table 1 under total weight for your model.
For Models:
2425L / V.168C-RHO and 2425L / V.268C-LHO;
For Models:
2645L / V.068C, 2771L / V.068C, 7236L / V.068C and 2422L / V.068C;
2. Remove the air bath and attach a 1 x 4 stringer to the studs, with the top of the stringer touching the traced line.
The rim of the bath must not support weight.
1. Position the air bath into the installation opening and level the deck in both directions, shimming the integral support feet IF necessary.
Mark the final position of the underside of the deck by tracing a line on to the studs (see Figure 1).
!
!
!
!
ACCESS PANEL MUST BE LOCATED
ON THE SAME SIDE AS THE AIR BATH.
ALLOW OPEN FRAMING ON BLOWER/MOTOR
END FOR SERVICE.
ACCESS PANEL MUST BE LOCATED
ON THE SAME SIDE AS THE AIR BATH.
ALLOW OPEN FRAMING ON BLOWER/MOTOR
END FOR SERVICE.
FOR E & D DIMENSIONS SEE TABLE 1 ON PAGE 5.
FOR G & F DIMENSIONS SEE TABLE 1 ON PAGE 5.
NOTE:
FRONT EDGE
OF BATH MUST
BE SUPPORTED
BY STUD WALL OR
AMERICAN STANDARD
APRON KIT
The rim of the bath must not support weight. If foundation base is used, allow the
bedding material to completely harden before applying weight to the rim or bottom of
the bath. Any finish material such as tile or wall board must be self-supporting if it
contacts the deck of the bath.
UNLESS AN ACCESS OPENING OF AT LEAST 12" X 24" (305 X 610mm)
IS PROVIDED, WARRANTY SERVICE WILL NOT BE PERFORMED.
UNLESS AN ACCESS OPENING OF AT LEAST 12" X 24" (305 X 610mm)
IS PROVIDED, WARRANTY SERVICE WILL NOT BE PERFORMED.
(EXCEPT 2425 WHERE APRON IS PRIMARY ACCESS OPENING)
ACCESS PANELS NOT REQUIRED
FOR BATH TUBS.
ACCESS PANELS NOT REQUIRED
FOR BATH TUBS.
8
754072-100 Rev. A
SUGGESTED AIR BATH / BATH INSTALLATION METHOD
SECURE THE BATH TO THE STUDS AS SHOWN FOR WOOD OR STEEL STUD CONSTRUCTION.
TYPICAL FLANGE MOUNTING DETAIL
Please note that care must be taken to protect the surface of the tub during all aspects of the installation.
Do not drill or cut the bath deck with the tub directly beneath it as damage to the tub may result.
1. Install the tub per the installation instructions provided with the unit.
2. Prepare the bath deck support structure per the local codes. Note - the bath deck must be self supporting.
3. Cut bath deck to your specifications.
4. Place the bath deck in position and trace the opening on the tub with a soft pencil. Do not drill or cut the bath
deck with the tub directly beneath it as damage to the tub may result.
5. Remove the bath deck and apply a generous bead of waterproof sealant on the outer edge of the traced line.
6. Replace the bath deck and secure it into place.
7. Apply additional sealant along the tub and bath deck interface as necessary to ensure a watertight seal.
8. Remove excess sealant per the manufacturer's instructions.
Finished bath deck surface material must be
self-supporting and secured per local codes
Tub support structure per installation
instructions provided with the tub
Bath deck support material
Bathtub
Waterproof
Sealant
UNDER DECK MOUNTING INSTRUCTIONS
STUD
WATERPROOF DRYWALL
OR CEMENT BOARD
WATERPROOF DRYWALL
OR CEMENT BOARD
TILE
SEALANT
TUB
ROOFING NAIL
1" x 3" (25 x 76mm) WOOD
STRINGER FULL LENGTH
1" x 3" (25 x 76mm) WOOD
STRINGER FULL LENGTH
STEEL
STUD
WASHER
TILE
SEALANT
TUB
4" (102mm)
DRYWALL
SCREW
WOOD STUDS STEEL STUDS
754072-100 Rev. A
9
All wiring must be performed by a licensed electrician in accordance with the national electrical code and all other applicable codes.
WARNING: When using electrical products, basic precautions should always be observed, including the following:
1. DANGER: RISK OF ELECTRIC SHOCK! Connect only to a circuit protected by a ground-fault circuit interrupter.
2. Permit access for servicing blower as noted.
3. All building materials and wiring should be routed away from the air blower.
AIR BATH ELECTRICAL INSTALLATION INSTRUCTIONS
!
The air bath should be installed on a 120 vac,
15 or 20 amp
dedicated GFCI circuit.
The circuit should be hard-wired from the electrical power supply panel. The
circuit must be a three (3) wire circuit from the electrical supply panel. A
grounded neutral wire and a third wire, earth ground, are essential.
GFCI CIRCUIT REQUIREMENTS: FOR MODEL NUMBERS:
2425L / V.168C-RHO 2422L / V.068C
2425L / V.268C-LHO 2645L / V.068C
2771L / V.068C 7236L / V.068C
PLEASE SEE THE FOLLOWING TABLE FOR GFCI CIRCUIT REQUIREMENTS:
ELECTRONIC ACTIVATED AIR BATH (4 BUTTON PANEL)
120V, 60HZ
15A GFCI
ELECTRICAL
FEED
GFCI
10
754072-100 Rev. A
REMOTE BLOWER LOCATION OPTION
IMPORTANT! It is not necessary that the blower motor be relocated. This option is provided for the case that a particular
installation makes this effort practical.
NOTE:
Relocating blower motor from factory installed location, see photo 1, will require disassembly of air blower from mounting
board. Keep all hardware for reattachment at new location. Additional hardware will be required depending upon final
desired position of air blower. Follow all instructions listed below.
NOTE: Installing the blower in a remote location will reduce the system efficiency.
NOTE: Relocating a blower motor still requires a service access for the blower.
NOTE: All materials needed for the relocation must be supplied by the installer. This includes ordering a longer control panel
cable (754025-0073A), a longer flexible blower hose (753960-2030A), and up to two lighting cable extensions for combo
models (754512-0070A).
A separate circuit, which must be protected by the Ground Fault Circuit Interrupter (GFCI), is required in the remote location.
Electrical connections should be performed by a licensed electrician.
The blower motor must be located within 12 feet of rigid piping from the bath air manifold. This limitation is for the total pipe length
and applies to any direction changes and elbows. There can be no more than six changes of direction. There should be as few
direction changes as possible and the piping installation must meet all requirements of local plumbing and building codes.
Disconnect the blower from the flexible hose as shown in photo 2. Do NOT remove the check valve manifold that is mounted to the
underside of the air bath. The manifold MUST remain mounted above the tub overflow level as shown in 2.
Replace the flexible hose shown in photo 2 with the longer flexible hose (P/N 753960-2030A) using the existing hope clamps.
NOTE: Do NOT remove the original cable coming out of the blower. Instead, plug the longer cable (P/N 754025-0073A) into the
existing cable that is coming out of the blower as shown in photo 3. Then plug the remaining end of the longer cable into
the control panel which remains on the tub wall.
1.
2.
3.
TYPICAL VIEW
TYPICAL VIEW
Do NOT move check
valve manifold
TO CONTROL PANEL
754025-0073A CABLE
(INCLUDES ADAPTER
BOX SHOWN)
TO BLOWER
EXISTING
CABLE
754072-100 Rev. A
11
POST INSTALLATION CLEAN-UP
Remove all construction debris from bath. Tile grout can be removed with a wooden popsicle stick or tongue depressor.
Do not use wire brushes or any other metal implement on bath surface.
Post installation clean-up generally can be completed using warm water and liquid dishwashing detergent.
Stubborn dirt or stains may be removed using granular Spic and Span
®
mixed with water.
Painter's naphtha can be used to remove excess adhesives and/or wet oil-base paint.
AFTERCARE and CLEANING
The high gloss surface is resistant to impact and chemicals and will retain its lasting luster with proper care and maintenance.
Always fill the tub with temperate water. Excessively hot water may cause surface damage
dry in the tub may cause surface damage.
Clean after use with a mild liquid household detergent cleaner. Do not use Lestoil, Lysol Disinfectant (spray or concentrate),
or Lysol Basin, Tub and Tile Cleaner, Windex, Mr. Clean, Dow Disinfectant Bathroom Cleaner, or cleaning products in
aerosol cans.
HARSH CHEMICALS SHOULD NEVER BE USED ON ACRYLIC SURFACES.
• Do not use wire brushes, knives or sharp objects to remove stains, cigarette tar deposits,or other surface blemishes.
Abrasive cleaners or powders must not be used, since they will dull the surface. If the glossy surface looses its sheen, dulled
areas can be restored by rubbing with a white "automotive type" polishing compound and waxing with a "liquid wax."
Do not wax areas where you walk or stand.
• Do not allow nail polish remover, acetone, dry cleaning fluid, paint remover or other solvents to come into contact with the surface.
• Clean the surrounding surface immediately after using caustic drain cleaners.
• Burning cigarettes will damage the surface.
• Should damage to the fixture occur, repairs can be made quickly and easily.
Your distributor or builder can provide details.
• Do not permit drain cleaner to enter the circulation system.
12
754072-100 Rev. A
BATHING:
Close drain by rotating Drain Overflow Knob COUNTER-CLOCKWISE
Fill bath with water at a comfortable bathing temperature, adding bath oils or salts as desired.
EXITING THE BATH
Be sure to turn off the air blower before draining bath.
Open drain by rotating drain knob clockwise.
OPERATING AIR MASSAGE SYSTEM:
Operation: Air Bath
DRYING CYCLE OPTIONS
STANDARD DRYING CYCLE
An automatic drying cycle will start 20 minutes after the blower is turned off. The blower LED blinks while waiting
for the purge cycle.
24H PROGRAMMABLE DRYING CYCLE
The system must be stopped prior to activation or deactivation.
Activation: Determine at which time you wish to purge to activate. At that precise time, press and hold the second button
on the keypad for 5 seconds, all LEDs will flash twice. The purge cycle will now start at the programmed time every
24 hrs. In the event of a power failure, the program will be automatically deactivated.
Deactivation: Press and hold the second button on the keypad for 5 seconds, all LEDs will flash once to confirm deactivation.
AIR SPEED INCREASE:
Pressing this button will increase to the next higher speed.
ON/OFF:
Press this button once to turn air-blower on.
Press again to turn air-blower off.
AIR SPEED DECREASE:
Pressing this button will decrease to the next lower speed.
WAVE FUNCTION:
Press this button to start the wave function (button will light).
Blower speed will continuously vary between high and low.
Press again to exit wave function (button light will go out).
754072-100 Rev. A
13
Fill whirlpool with warm water and add two teaspoons of powdered automatic dishwasher (not laundry)
detergent and one-half cup of household bleach to filled whirlpool.
Activate whirlpool system in accordance with operating instructions and run system for two minutes.
Drain and refill whirlpool with cold water. Circulate for five minutes.
Drain whirlpool completely after step 3 (above) is completed.
Your American Standard whirlpool is designed to give you many years of pleasure with reasonable care and
maintenance.
Your new acrylic bathtub is tough, durable and easy to care for. The colors have been formulated to match other
American Standard fixtures and enhance your choice of bathroom decorations. The high gloss surface will retain its
lasting luster with proper care and maintenance.
CLEANING AND MAINTENANCE:
Always fill the tub with temperate water. Excessively hot water (greater than 130˚ F) may cause surface damage.
Remove bath mat after use and hang to dry. Allowing bath mat to dry in the tub may cause surface damage.
Clean after use with a mild liquid household detergent cleaner. Do not turn on jets when such cleaners are present.
Do not use: Lestoil® Cleaner; Lysol® Disinfectant (spray or concentrate); or Lysol® Basin, Tub and Tile Cleaner;
WindeCleaner; Mr. CleaCleaner; Dow® Disinfectant Bathroom Cleaner*; or other cleaning products in
aerosol cans.
HARSH CHEMICALS, SHARP AND ABRASIVE OBJECTS
SHOULD NEVER BE USED ON ACRYLIC SURFACES
• Do not use wire brushes, knives or sharp objects to remove stains or other surface blemishes.
• Use of abrasive cleaners or powders will dull the surface. If the glossy surface looses its sheen, dulled areas can
be partially restored by rubbing with a white automotive body polishing compound and waxing with a liquid wax.
Do not wax surfaces where you walk or stand.
• Do not allow nail polish remover, acetone, dry-cleaning fluid, paint remover, or other solvents to come into contact
with the surface.
• Clean the surrounding surface immediately after using caustic drain cleaners.
Do not permit drain cleaner to enter circulation system.
• Burning cigarettes will irreparably damage the surface of the whirlpool.
CLEANING/PURGING THE CIRCULATION SYSTEM
Once every month the circulating system must be purged and cleaned. Follow the steps outlined below:
1.
2.
3.
4.
For Troubleshooting and Repair Parts please log on to www.americanstandard-us.com
* Lestoil® is a registered trademark of The Clorox Company.
Lysol® is a registered trademark of The Linden Company.
Windex® is a registered trademark of S.C. Johnson and Son, Inc.
Mr. Clean® is a registered trademark of The Proctor and Gamble Company.
Dow® is a registered trademark of The Dow Chemical Company.
14
754072-100 Rev. A
AS America, Inc. Limited Lifetime Warranty For Lifetime
™/
Evolution
Acrylic Air Baths
AS America, Inc. (”American Standard”) warrants to the original consumer purchaser that it will, at its option, repair
or replace this air bath or any of its parts that are found by American Standard, in its sole judgment, to be defective
under normal residential use and maintenance so long as it is owned by the original consumer purchaser.
This warranty shall only become effective upon receipt by American Standard of a completely filled out Warranty
Registration Card evidencing proof of purchase.
This limited warranty does not apply to commercial installations. The warranty for commercial installations is three
(3) years.
THIS WARRANTY SHALL BE VOID IF THE ACCESS PANEL TO THE AIR BATH IS COVERED IN ANY MANNER
CONTRARY TO THE INSTALLATION INSTRUCTIONS. In no event will American Standard be liable for the cost of
repair or replacement of any installation materials including but not limited to tiles, marble etc.
This limited warranty DOES NOT COVER the following:
1. Defects or damages arising from shipping, installation, alterations, accidents, abuse, misuse, lack of proper
maintenance and cleaning as directed in the owners manual and use of other than genuine American Standard
replacement parts, in all cases whether caused by a plumbing contractor, service company, the owner or any other
person.
2. Deterioration through normal wear and tear and the expense of normal maintenance.
3. Commercial application.
4. Options and accessories. American Standard’s limited warranty on these items is one year for parts only and
excludes labor. This one year limited warranty covers accessories manufactured by American Standard (e.g.
aprons, drains, grab bars, heaters, trim kits) against defects of material or workmanship. Warranty coverage begins
on the date the accessory was originally purchased by the owner.
5. Postage or shipping costs for returning products for repairs or replacement under this limited warranty and labor
or other costs incurred in connection with product removal or installation under this limited warranty.
6. ANY LIABILITY FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES, ALL OF WHICH ARE HEREBY
EXPRESSLY DISCLAIMED, OR THE EXTENSION BEYOND THE DURATION OF THIS LIMITED WARRANTY OF
ANY IMPLIED WARRANTIES, INCLUDING THOSE OF MERCHANTABILITY OR FITNESS FOR AN INTENDED
PURPOSE. (Some jurisdictions do not allow limitations on how long an implied warranty lasts, or the exclusion or
limitation of incidental or consequential damages, so these limitations and exclusions may not apply to you.)
7. Responsibility for compliance with local code requirements. (Since local code requirements vary greatly
distributors, retailers, dealers, installation contractors and users of plumbing products should determine whether
there are any code restrictions on the installation or use of a specific product.)
This warranty gives you specific legal rights. You may have other leg
al rights that vary from state to state.
For service under this warranty, you should contact the following:
By Mail: American Standard Brands
P.O. Box 6820
Piscataway, N.J. 08855
Attention: Customer Care Center
By Telephone:
1-800-442-1902
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14

American Standard 2422.068C.222 Installation guide

Category
Air blowers/dryers
Type
Installation guide

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI