Cello Lighting Z-OMNI4IN1SM300W2X4 is a 4-in-1 fixture that integrates UVC Surface Disinfection, UVC Air Disinfection, HEPA Filtering and Needlepoint Bipolar Ionizers (NPBI) into one single product. It can be controlled remotely and provides a comprehensive log of all fixture schedules, usage, and activities via Cello Cloud. The Z-OMNI4IN1SM300W2X4 is suitable for 1000 sq. ft. spaces and can disinfect surfaces 99.9% in 25 minutes, and air 99.95% in 10 minutes. It also has a HEPA filter with a 99.954% disinfection rate and an NPBI system that deactivates 96.7% of pathogens.

Cello Lighting Z-OMNI4IN1SM300W2X4 is a 4-in-1 fixture that integrates UVC Surface Disinfection, UVC Air Disinfection, HEPA Filtering and Needlepoint Bipolar Ionizers (NPBI) into one single product. It can be controlled remotely and provides a comprehensive log of all fixture schedules, usage, and activities via Cello Cloud. The Z-OMNI4IN1SM300W2X4 is suitable for 1000 sq. ft. spaces and can disinfect surfaces 99.9% in 25 minutes, and air 99.95% in 10 minutes. It also has a HEPA filter with a 99.954% disinfection rate and an NPBI system that deactivates 96.7% of pathogens.

Specifications for Cello OMNI 4-in-1 Fixture
01/27/2021 1
Cello Lighting, Inc. Address: 2570 N. First Street, Second Floor, San Jose, CA 95131
TEL: +1-888-588-8849 Email: [email protected]
CELLO OMNI
4-IN-1 FIXTURE
SPECIFICATIONS
ANYTIME, ANYWHERE, BY ALL MEANS
Cello UV Air 4-in-1 Fixture integrates UVC Surface
Disinfection, UVC Air Disinfection, HEPA Filtering and
Needlepoint Bipolar Ionizers (NPBI) into one single
product. In addition, fully integrated controls allow
for remote scheduling, remote control and a
comprehensive log of all fixture schedules, usage, and
activities via Cello Cloud.
Cello Lighting, Inc.
Palo Alto, CA 94303
Specifications for Cello OMNI 4-in-1 Fixture
01/27/2021 2
Cello Lighting, Inc. Address: 2570 N. First Street, Second Floor, San Jose, CA 95131
TEL: +1-888-588-8849 Email: [email protected]
Table of Contents
I. Product Overview (Video) ....................................................................................................... 3
II. Disinfection Guidelines ............................................................................................................ 4
III. Technical Specifications ....................................................................................................... 5
IV. Case Study of UVC Surface Disinfection (Height = 9 ft.) ...................................................... 6
V. Case study of UVC Air Disinfection (1000 sq. ft. x 9 ft.) .......................................................... 7
VI. HEPA Filtering Test Report ................................................................................................... 8
VII. NPBI Specifications (Cello NPBI D24) ................................................................................... 9
VIII. Quick Start Guide ............................................................................................................... 12
IX. Cello Cloud Services (CelloVira.com) ................................................................................. 13
X. Scheduling of Cello UV AIR 3-in-1 Fixture.............................................................................. 15
Appendix A: Interpolation of SARS-CoV-2 Test Report ................................................................. 17
Specifications for Cello OMNI 4-in-1 Fixture
01/27/2021 3
Cello Lighting, Inc. Address: 2570 N. First Street, Second Floor, San Jose, CA 95131
TEL: +1-888-588-8849 Email: [email protected]
I. Product Overview (Video)
Specifications for Cello OMNI 4-in-1 Fixture
01/27/2021 4
Cello Lighting, Inc. Address: 2570 N. First Street, Second Floor, San Jose, CA 95131
TEL: +1-888-588-8849 Email: [email protected]
II. Disinfection Guidelines
Surface Mode UVC Disinfection
Area
500 sq. ft.
1000 sq. ft.
1500 sq. ft.
Time*
10 min
25 min
50 min
*Required time to operate for 99.9% disinfection rate.
Air UVC Disinfection
CFM
Disinfection
Ambient Noise
9000 cu. ft
900
99.95%
65 dB
10 minutes
450
99.99%
50 dB
20 minutes
* Time to exchange 100% of air.
HEPA Filter Disinfection
CFM
Disinfection
Ambient Noise
9000 cu. ft
900
99.954%
65 dB
10 minutes
450
99.954%
50 dB
20 minutes
NPBI Disinfection (Optional)
CFM
Disinfection
Ambient Noise
9000 cu. ft
900
96.7%*
65 dB
10 minutes
450
96.7%
50 dB
20 minutes
*Independent testing in April 2020 showed that NPBI deactivated 99.4% of SARS COVID-2 (the virus
that causes COVID-19) in 30 minutes. Importantly, NPBI technology safely deactivates pathogens in the
air and on surfaces in real time, while spaces are occupied.
** NPBI is an OPTIONAL feature. If users do not like NPBI, they can use the remote control to turn off
CH3: IONIZERS to turn off the NPBI feature.
Specifications for Cello OMNI 4-in-1 Fixture
01/27/2021 5
Cello Lighting, Inc. Address: 2570 N. First Street, Second Floor, San Jose, CA 95131
TEL: +1-888-588-8849 Email: [email protected]
III. Technical Specifications
Value
120VAC 50/60Hz
5 amps (motor & lamps)
Available on Wi-Fi Controller
47.36” x 23.74” x 4”
30 lb.
253.7 nm
450W (3 of 150W) U-type UVC lamps
< 0.05 ppm (compliant with UL 867 no-ozone standard)
Up to 1000 sq. ft.
From remote control or Smartphone App
Located at the bottom of the unit
Stainless Steel
Individual Wall Hung unit or ceiling mounted unit
95%
40 dB 65 dB
1 mW/cm2
200 CFM 900 CFM
6 Air Echanges per hour (@900 CFM)
60 million ions
3 years unit / 1 year Lamp (8000 hours)
Specifications for Cello OMNI 4-in-1 Fixture
01/27/2021 6
Cello Lighting, Inc. Address: 2570 N. First Street, Second Floor, San Jose, CA 95131
TEL: +1-888-588-8849 Email: [email protected]
IV. Case Study of UVC Surface Disinfection (Height = 9 ft.)
Area
500 sq. ft.
1000 sq. ft.
Time*
10 min
25 min
*Required time to operate for 99.9% disinfection rate.
Specifications for Cello OMNI 4-in-1 Fixture
01/27/2021 7
Cello Lighting, Inc. Address: 2570 N. First Street, Second Floor, San Jose, CA 95131
TEL: +1-888-588-8849 Email: [email protected]
V. Case study of UVC Air Disinfection (1000 sq. ft. x 9 ft.)
UVC power = 300W
Specified UVC intensity = 1 mW/cm
2
@ 1 meter
Farthest distance of air inside Fixture from UVC lamp = 0.2 meter;
0.6mW x 1
2
= Fixture UVC Intensity x (0.15)
2
(reverse square law)
Fixture UVC Intensity = 1 (1/0.15)
2
= 44.4 mW/cm
2
@ 0.2 meter
Air Unit Volume = 1.2 M x 0.6 M x 0.1M = 0.072 cu. meter = 2.58 cu. ft.
Cross Section Area = 0.1M x 0.6M = 0.06 sq. meter = 0.65 sq. ft.
Assume air exchange rate is 900 cfm = 900 cu. ft./minute
Air Flow Speed = (900 cu. ft. /minute)/ 0.65 sq. ft. = 1384 ft./minute
=23.06 ft/second = 6987 mm/second
Air stays in this Unit for: 1200 mm/ 6987(mm/s) = 0.28 seconds
Dosage = 44.4 mW/cm
2
x 0.28 seconds = 12.43 mJ/ cm
2
Disinfection Rate = 99.95% (refer to Appendix A)
Conclusion:
It takes 9000 cu. ft./900 cfm = 10 minutes to exchange 9000 cu. ft. of air with 99.95%
disinfection rate; that is:
6 air exchanges per hour to disinfect 99.95% of the air.
Specifications for Cello OMNI 4-in-1 Fixture
01/27/2021 8
Cello Lighting, Inc. Address: 2570 N. First Street, Second Floor, San Jose, CA 95131
TEL: +1-888-588-8849 Email: [email protected]
VI. HEPA Filtering Test Report
Specifications for Cello OMNI 4-in-1 Fixture
01/27/2021 9
Cello Lighting, Inc. Address: 2570 N. First Street, Second Floor, San Jose, CA 95131
TEL: +1-888-588-8849 Email: [email protected]
VII. NPBI Specifications (Cello NPBI D24)
Specifications for Cello OMNI 4-in-1 Fixture
01/27/2021 10
Cello Lighting, Inc. Address: 2570 N. First Street, Second Floor, San Jose, CA 95131
TEL: +1-888-588-8849 Email: [email protected]
Specifications for Cello OMNI 4-in-1 Fixture
01/27/2021 11
Cello Lighting, Inc. Address: 2570 N. First Street, Second Floor, San Jose, CA 95131
TEL: +1-888-588-8849 Email: [email protected]
Specifications for Cello OMNI 4-in-1 Fixture
01/27/2021 12
Cello Lighting, Inc. Address: 2570 N. First Street, Second Floor, San Jose, CA 95131
TEL: +1-888-588-8849 Email: [email protected]
VIII. Quick Start Guide
1. Turn on light switch to energize the fixture.
2. Tune Fan Speed
3. Hold remote to control the Wi-Fi Panel:
4. Turn on CH2 (Turn on UVC lamps)
5. Turn on CH3 (Turn on NPBI)
6. Turn on CH4 (Turn on FAN)
7. Turn on CH1 to enter SURFACE Mode
(UV lamps rise)
8. Turn off CH1 to enter AIR Mode
(UV lamps descend)
Specifications for Cello OMNI 4-in-1 Fixture
01/27/2021 13
Cello Lighting, Inc. Address: 2570 N. First Street, Second Floor, San Jose, CA 95131
TEL: +1-888-588-8849 Email: [email protected]
IX. Cello Cloud Services (CelloVira.com)
To enjoy the powerful Cello Cloud Services at CelloVira.com, please do the following:
3. Once you received your user/password, follow instructions to connect Cello UV 3-in-1 to
Internet through your existing Wi-Fi networks:
1. Identify the APP ID on your Cello OMNI 4-in-1 Fixture.
2. Email your APP ID to: Customer_Service@CelloLighting.com
SUBJECT: APP ID = 100109ce70 (your own ID)
CONTENT: Model Name (e.g., Cello OMNI 4-in-1 Fixture)
Contact Name
Organization Name
Address
Phone Number
3. M
ID 100109ce70
Specifications for Cello OMNI 4-in-1 Fixture
01/27/2021 14
Cello Lighting, Inc. Address: 2570 N. First Street, Second Floor, San Jose, CA 95131
TEL: +1-888-588-8849 Email: [email protected]
The top Menu includes the following:
Products: Specifications sheets of Products
Devices: Managing your Cello UV devices
User Profile: Update your profile
User Manuals: User manuals of Cello UV products.
Use your new CelloVira USER/PASS to log in at:
CelloVira.com
Once logged in, you will see the following home page:
Specifications for Cello OMNI 4-in-1 Fixture
01/27/2021 15
Cello Lighting, Inc. Address: 2570 N. First Street, Second Floor, San Jose, CA 95131
TEL: +1-888-588-8849 Email: [email protected]
X. Scheduling of Cello UV AIR 3-in-1 Fixture
Please visit CelloVira.com, log in the portal with your USER/PASS.
Then Click <DEVICES>
Click <Group Name>
Specifications for Cello OMNI 4-in-1 Fixture
01/27/2021 16
Cello Lighting, Inc. Address: 2570 N. First Street, Second Floor, San Jose, CA 95131
TEL: +1-888-588-8849 Email: [email protected]
For instance, in this example:
Cello UV 3-in-1 status at 01:04 PM is: (Valid from 12/22/2020 to 01/06/2021)
CH2 is turned ON: UVC Lamps ON
CH3 is turned ON: ION ON
CH4 is turned ON: FAN ON
(ALL of UVC Air Disinfection, HEPA Filter and NPBI are working)
Cello UV 3-in-1 status at 01:58 PM is: (Valid from 12/23/2020 to 01/07/2021)
CH2 is turned OFF: UVC Lamps OFF
CH3 is turned ON: ION ON
CH4 is turned ON: FAN ON
(Only HEPA Filter and NPBI are working. UVC is turned off to save energy.)
Specifications for Cello OMNI 4-in-1 Fixture
01/27/2021 17
Cello Lighting, Inc. Address: 2570 N. First Street, Second Floor, San Jose, CA 95131
TEL: +1-888-588-8849 Email: [email protected]
Appendix A: Interpolation of SARS-CoV-2 Test Report
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17

Cello Lighting Z-OMNI4IN1SM300W2X4 User manual

Type
User manual

Cello Lighting Z-OMNI4IN1SM300W2X4 is a 4-in-1 fixture that integrates UVC Surface Disinfection, UVC Air Disinfection, HEPA Filtering and Needlepoint Bipolar Ionizers (NPBI) into one single product. It can be controlled remotely and provides a comprehensive log of all fixture schedules, usage, and activities via Cello Cloud. The Z-OMNI4IN1SM300W2X4 is suitable for 1000 sq. ft. spaces and can disinfect surfaces 99.9% in 25 minutes, and air 99.95% in 10 minutes. It also has a HEPA filter with a 99.954% disinfection rate and an NPBI system that deactivates 96.7% of pathogens.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI