PHYSICAL INSTALLATION
It is imperative that the lights are mounted in such a location that
the fixtures are protected from the rear against water exposure.
Also, it is important that the lights are mounted with airspace
around the heat sink housing to allow for convective cooling
of the lights. We recommend a distance of ½” (13mm) of free
space above the housing.
- 4 -
½” (13mm)
Resonance suppression
band (do not remove)
Spring Mount Installation Instructions
1. A. For Sardinia/Cyprus fixed
direction models: Cut a 2 7/8”
(73mm) diameter circle in the
mounting surface.
B. For Cyprus Eyeball: Cut
a 3 3/8” (85mm) circle in the
mounting surface, Note: the hole
must not be any larger than this.
2. Connect the light to an AC power
source following the Wiring
Instructions in the next section of
this guide.
3. Once all electrical connections are
made and secure, gently bend
back the mounting springs of your
PowerLED and insert the spring
tips into the cutout circle in the
mounting surface (see Figure 1).
- 5 -
Figure 1
Screw Mount Installation Instructions
1. For Sardinia/Cyprus fixed direction
fixtures: Cut a 2 7/8” (73mm) diameter
circle in the mounting surface.
2. Connect the light to an AC power
source following the Wiring
Instructions in the next section of this
guide.
3. Once all electrical connections
are made and secure, insert your
PowerLED into the cutout circle and
fasten with #4 flat head screws (see
Figure 2).
4. Place the trim ring over the light
making sure the tabs of the housing
engage the openings of the trim ring.
Twist the trim ring on to secure it.
Figure 2
Use #4 at head
screws only
- 6 - - 7 -
WIRING INSTRUCTIONS
1. Wiring connections shall be made within
the necessary enclosures (junction boxes) as
required by any applicable standards, codes
or laws. The available bracket and Molex
TM
connector may be used where appropriate.
Otherwise, 18” of triplex cable is provided to
allow proper wire routing to a suitable location.
2. Connect the light to an AC power source by connecting the
white wire to neutral, the black wire to live and the green/
yellow wire to ground.
3. If a dimmer is used, the black wire should be connected to the
terminal or wire labeled “LOAD” on the dimmer.
4. Please refer to wiring diagrams and dimmer compatibility
chart on pages 8-11.
Wire Function
Black Live
White Neutral
Green/Yellow Ground
IP40 & IP65 models