FLEXX36HP230V1BH

GREE FLEXX36HP230V1BH User manual

  • Hello, I'm your chat assistant. I've reviewed the Product Bulletin regarding the installation of 15KW heat kits on 3T FLEXX Air Handlers, specifically model FLEXX36HP230V1BH. The document outlines a specific issue with the heat sequencer location and provides a step-by-step solution to ensure proper and straightforward installation. I'm here to help with any questions you might have about this process.
  • What is the issue addressed in this bulletin?
    What are the first two steps for the installation?
    What should be done with the lower screw after removing it?
    Is this a universal bulletin for all FLEXX models?
Product
Bulletin
1
|
P
a
g
e
Use of 15KW Heat Kits on 3T FLEXX
Air Handlers
Document #: TB-FLX-09152022 Date Issued: Sept. 15, 2022
Author: James McIntyre
Reference: FLEXX 3-ton Air Handlers with 15KW Electric Heat Kit
Product Group: FLEXX
Models Affected: FLEXX36HP230V1BH
Serial Number Range: All
Summary:
The location of the heat sequencer on the heat kit hinders the installation of a 15KW heat kit in
model FLEXX36HP230V1BH.
Solution:
For the installation of the 15KW heat kit, please follow these steps:
1. Before work, please ensure the power has been disconnected.
2. Remove the two screws located at the top and bottom of the heat sequencer.
3. Using the two identical holes directly to the right, partially install the lower screw.
4. Slide the heat sequencer onto the lower screw.
5. Install the upper screw and tighten the lower screw.
6. Complete the installation of the heat kit as normal.