Commax CDL-2AR/CDL-2ARC Owner's manual

Type
Owner's manual
CDL-2AR_도큐 2018.3.6 4:57 PM 페이지2
User Manual
2
Digital Door Lock COMMAX
Robust & Reliable Product with Korean Quality Certificates
Strict quality & manufacturing system with KS (=Korea Industrial Standard) certificates.
Highly Durable Metal Body
Designed with metal body for highest durability against fire or physical impact from outside.
Auto-lock / Reverse-lock / Dual-lock
To provide users with the best convenience and safety.
Multiple Registration of passwords / smart keys
Different passwords (max. 4ea) or smart keys (max. 30ea) can be registered.
Multi Step Volume Control / Optional Silence Mode
Total 7 different sound volume mode can be selectable.
Button plate with lights for dark plate use.
Once touch the button plate, each buttons light on and make easier to use in the dark.
Emergency Power Supply (9V Alkaline quadrangle battery 1ea)
If batteries are fully discharged, 9V battery can be used for supplying emergency power.
Anti-excessive voltage / fire / hacking system
It’s safe equipped with anti-excessive voltage/hacking system. It also has fire-detection
sensors checking the indoor temperature. If temperature is out of normal and fire might
be occurred, doorlock is automatically unlocked.
Major Features
CDL-2AR_도큐 2018.3.6 4:57 PM 페이지3
3
Safety Caution
Do not install,
disassemble, repair
products at random.
Do not push buttons with
sharp material like pin or
awl etc.
If battery is inserted
adversely, liquid leak or
battery disruption might
be occurred.
(LR6 AA)
When cleaning, use
dried superfine fibers
towel.
This product is
applicable for residential
fire-door only.
Read user guide
carefully before use.
Regular update or
change password is
recommended for safety.
Do not impact product
with excessive force.
Make sure no water
enters into inside of
product.
All 4 new batteries have
to be replaced at once.
Keep product warrantee
card for after sales
service.
Do not use other
purposes besides digital
door lock usage.
CDL-2AR_도큐 2018.3.6 4:58 PM 페이지4
Content
01
Specification & Components
02
Part Name
03
How to Use
Register/Change Password
Register/Change Smart Key
How to delete Smart Key
Open door from outside
Close door from outside
Open door from inside
Close door from inside
Compulsive Lock
Smart Key sensor setting (Auto/Manual)
Auto/Manual Lock Setting
Sound Pause
Sound Adjustment
Manual Lock LED setting
Multi-touch security setting
Master features setting
Remote controller setting
08
09
10
10, 11
11
12
12
13
13
04
Convenient Function
(option)
14
14
15
15
16
16
18
High Temp. Alert
Burglar Alert
Wrong input prevention
Mortise trapping Alert
Battery Replacement Alarm
05
Emergency Alert
19
19
19
20
20
06
Cause and Solution
21
05
06
4
CDL-2AR_도큐 2018.3.6 4:58 PM 페이지5
Digital Door Lock COMMAX
Component
5
Specification
01
Outdoor Body Indoor Body Striker
Smart Key (4ea)
Battery (4ea)
Screw
Mortise
Warning Sticker
Installation GuideUser Guide
(inclu. Product Warrantee)
Product Specification
Category
Installed at Common Fire Door
Password
Smart Key
Door Open by
Power Source DC 6V
Emergency Power DC 9V
Product Category
Direct Current, Non fire-resistance type, Temperature Sensor,
Non physical-key type, Main key door lock (D-NF-T-NK-M)
Temperature
Detection
Temperature
Sensor type
72°C ± 5°C (at Lab.)
62°C ± 5°C (at Site)
Materials
Al, Zn, ABS
Zn, ABS
Spec.
Romote Controler
(Only for CDL-2ARC)
RF Spec
Item
RFID
Frequency
13.56Mhz
Channels
1ea
Modulated by
ASK
Electric field strength
93.5dBuV/m@10m
Safety Wireless device
447.275Mhz 10mW
Mortise Shaft
Indoor
Connection Shaft
CDL-2AR_도큐 2018.3.6 4:58 PM 페이지6
Door Thickness 40mm ~ 50mm
4~12 digits (total 4 passwords registrable)
Less than 30 keys registrable.
LR6 1.5V AA size Alkaline battery (4ea)
Alkaline 9V battery (1ea)
Outdoor Body
Indoor Body
1ea FSK
Outdoor unit
6
Part name
02
Function DescriptionName
Number Plate
Open the door by input the password.
Interface plate when register or change a new password.
Battery Alert
Touch Plate
Smart key interface plate. Unlock the door by touching
smart key. Interfacing plate for registration of new smart key.
Reset Switch If malfunction, product is reset by push this button.
Emergency
Power Outlet
If batteries are fully discharged, touch 9V battery onto this
outlet to supply emergency power.
Lever Indoor lever handle.
9V Emergency Battery
(Prepared by user)
CDL-2AR_도큐 2018.3.6 4:58 PM 페이지7
Alarms-on with emergency sound when extremely low voltage.
Digital Door Lock COMMAX
7
Indoor Unit
Battery Cover
Register button
Damage prevention cover for battery, register button etc.
Used for register or change pass word or smart keys.
Installed at flank side of door for close / open the door.
Locking bolt to close the door.
To prevent door shaking
Power supply battery
Mortise
Dead bolt
Latch bolt
Alkaline AA battery
Manual Lock
LED flicker
To lock the door when manual mode or dual lock setting is required.
When door is not closed during manual mode,
flicking LED lights to show the door open status.
Lever Indoor lever handle
Function DescriptionName
CDL-2AR_도큐 2018.3.6 4:58 PM 페이지8
8
How to Use
03
Register / Change Password
Door MUST BE OPEN during this work.
Open battery cover of inside door body
first. Then the push button of “Register”
until beep sounds ringing.
After checking the light-on the mode of
number plate,
Input new password (4~12 digits of numbers).
Touch [ ] button on number plate,
registration is completed with beep sound.
If new password is not input until 10secs after pushing “Register” button,
Work is canceled. If new registration process is completed, previous
password is automatically deleted.
If additional passwords are registered, (up to 4 different passwords)
Repeat
&
before light-off of number plate.
Go to the outside of door
Stand at the outside of door
Stand at the outside of the door
CDL-2AR_도큐 2018.3.6 4:58 PM 페이지9
CAUTION
NOTE
CAUTION
Digital Door Lock COMMAX
9
Register / Change Smart Key
Open battery cover of inside door body
first. Then push button of “Register”
until beep sounds ringing.
After checking the light-on mode of
number plate,
Touch smart keys on touch plate one by one.
(Once key is touched & registered,
beep sounds ringing)
After all keys registered,
push [ ] button for completion.
If smart key is not touched until 10 secs after pushing “Register” button,
work is canceled. If new registration process is completed, previous
smart key is automatically deactivated.
If additional smart keys are registered, (up to 30 keys)
Repeat
before light-off of number plate.
‘삑
‘삑
‘삑
‘삑
‘삑
‘삑
‘삑
‘삑
‘삑
‘삑
‘삑
‘삑
‘삑
‘삑
‘삑
‘삑
‘삑
‘삑
When registering or re-registering a smart key,
you must register all the smart keys you have AT ONCE.
CDL-2AR_도큐 2018.3.6 4:58 PM 페이지10
CAUTION
Go to the outside of door
Stand at the outside of door
Stand at theoutside of the door
NOTE
CAUTION
How to Delete Smart key
Open the inside of [Battery cover]
and push the [registration] button
to hear beep sound.
After check outside light on [Keypad],
When touch [ # ] button for 5sec,
registered smart key are deleted
with beep sound.
How to Use
03
5 seconds
‘삑
‘삑
‘삑
‘삑
‘삑
‘삑
‘삑
‘삑
‘삑
‘삑
‘삑
‘삑
‘삑
‘삑
‘삑
‘삑
‘삑
‘삑
10
Open door from the outside
After touching [Keypad], when
press [Password], [ ] button,
you can hear beep sound and
door will be open.
By password
Way 1
CDL-2AR_도큐 2018.3.6 4:58 PM 페이지11
Go to the outside of door
Stand at the outside of door
Digital Door Lock COMMAX
11
If you close door, door will be locked
Automatically. (Please refer to P. 14)
Door lock from the outside
Way 1
In case of setting auto lock function
Way 2
If you touch [number plate]
door will be locked. (Please refer to P. 14)
In case of locking manually
Touch registered [smart key] to
[Smart key access point]
By Smart Key
After beeping sound, open door.
Way 2
Smart phones and transportation cards (T-Money, Cashbee)
with a transportation card function other than the provided smart key
can be opened by touching the outdoor.
Open door from the outside
CDL-2AR_도큐 2018.3.6 4:58 PM 페이지12
CAUTION
12
Open door from indoor
Door will be locked again if door doesn’t
open within 7seconds.
How to Use
03
Way 1
You can open door if you
pull down door knob.
Pull down door knob.
Door will be locked automatically
after 2seconds, when door is closed.
(Please refer to P.14)
Lock from indoor
Way 1
In case of auto lock setting,
Way 2
When you push [manual lock]
while door lock open, it will be
locked.
In case of manual lock,
7 seconds
In case of manual lock function, if door doesn’t lock fully while door
close, indoor LED blink. (Refer to P.15)
CDL-2AR_도큐 2018.3.6 4:58 PM 페이지13
CAUTION
NOTE
2 seconds
Digital Door Lock COMMAX
13
Forcible Lock Function
Double lock
This function is that door is not opened from outside by any kinds of opening way
like even password and smart key.
Set up
Removal
When pulling down door knob inside and
opening door, double lock setting will be
released.
While door is locked,
if you push [manual lock] of indoor
body for 3seconds, setting completed
with ‘sound’.
Setting Auto•Manual Smart key mode
This function is that Smart key is detected automatically or manually.
Can open door by touching smart key access in the mode of
auto detect.
Can open door by touching smart key access after touching
number plate.
After touching
number plate,
1
Enter [password]
2
push[#] twice
in a row.
3
[1] : Auto-detect
setting
[3] : Manul-
detect setting
4
CDL-2AR_도큐 2018.3.6 4:58 PM 페이지14
3 seconds
NOTE
14
Convenient Function (Option)
04
AutoManual Lock setting
This function is that door is locked automatically/manually
Factory default is auto lock setting.
Please check
motise pop up.
1
Touch outside
[Keypad]
2
Input password
and push
[#] button twice.
3
[4] : Auto lock
[7] : Manual lock
4
After touching outside [number plate],
touch [ # ] button.
Enter [Password].
How to use
Sound pause function
This function is for One time mute to prevent beeping.
This is one time function. Beeping will be activated on next use.
How to use
While door keeps half open.
CDL-2AR_도큐 2018.3.6 4:58 PM 페이지15
NOTE
NOTE
Digital Door Lock COMMAX
15
After touching
outside number
plate
How to use
Volume control
This function is to control volume level. (In case door closes)
There are 7 levels to control.
On outside number plate, touch [3] button several time, volume
up. touch [6] button several time, volume down. When entering
Stop volume function, keypad Blink.
1
Enter [password]
2
Push [#] button
3
Push [3] or [6]
on outside
number plate.
4
LED Manual lock (No remote controlled model)
Enable and Disable LED ON
LED flickers for 2min in intruder or fire alarm. On Low Battery,
if door locks, LED flickers once.
LED flickers when door is not locked, LED doesn’t flicker when door is locked on
manual close mode.
(Factory default is LED manual lock)
Touch [number
plate] of outdoor
while door locks.
1
Enter [password]
2
Touch [#] button
3
Enable : [2]
Disable: [0]
4
CDL-2AR_도큐 2018.3.6 4:58 PM 페이지16
NOTE
NOTE
16
Convenient Function (Option)
04
Open battery
cover and push
[registeration]
button
1
Push [manual lock]
button
2
Touch [ ]
five times.
3
Master function
Entering Master Mode
In case master password are registered already, when touching
[registeration] beep sounds. Please call building manger.
This function is to manage digital door lock in office, accommodation and apartment.
Multi-Touch Security function
After touching
outside number
plate
1
Enter password
2
After touching
[ # ] button
3
Touch [5] in
number plate
4
When multi-touch function is activated, if you enter password,
three(3) LED number in random order are on and you can open
door when you touch [ ].
When multi-touch function is activated, follow
①②③④
this function
will be disactivated.
This is double security function by entering additional password.
It can delete finger print and divulge password.(In case door locks).
CDL-2AR_도큐 2018.3.6 4:59 PM 페이지17
Digital Door Lock COMMAX
CAUTION
NOTE
NOTE
NOTE
17
How to register master number and smart key
If password is incorrect, master mode will cancel with alert sound.
Please be careful to keep password and smart key otherwise new
registeration /deletion is not possible.
How to delete master key
1) New registeration
Register master password
- In master mode, when entering password and touching [ ] button,
master password is registered with beep sounds.
Register master smart key
- In master mode, when entering password, touching [ ] button and smart key,
master smart key will be registered. (upto 10 smart key).
2) Change to password
Register master password
- In master mode, please enter registered password and touch [ ] button.
And register new master password with [ ] button. It will be done with beep sound.
- If new password is registered, previous password is deleted.
- When canceling during registeration, previous password remains.
Register master smart key
- In master mode, when entering registered password, touching [ ] button
and smart key, master smart key will be registered. (upto 10 smart key).
- If new master smart key is registered, previous key is deleted.
- When canceling during registeration, previous master key remains.
1) Delete password
- In master mode, please enter registered password and touch [ # ] button.
Touch [1] and [ # ], it will delete with beep sound.
2) Delete smart key
- In master mode, please enter registered password and touch [ # ] button.
Touch [2] and [ # ], it will delete with beep sound.
3) Delete password & smart key
- In master mode, please enter registered password and touch [ # ] button.
Touch [3] and [ # ], password & smart key will delete together with beep sound.
CDL-2AR_도큐 2018.3.6 4:59 PM 페이지18
CAUTION
18
Remote controller setting
This is how to open door with remote controller. (For the remocon model)
To register remocon
Open battery cover,
push [registeration]
button
1
When pushing
[registeration] or [open]
button, registered
with sound.
2
When touching [ ]
button, registeration
will be competed with
beep sound.
3
If touching [#] button
for more than 5seconds,
all registered remocons
will be deleted.
3
To delete remocon
Open battery cover,
push [registeration]
button.
1
After touching [0] on
number plate,
2
After push [registeration] button, registeration fails in 10seconds,
it cancels. If new remocon registers, previous remocon is deleted
automatically.
Convenient Function (Option)
04
CDL-2AR_도큐 2018.3.6 4:59 PM 페이지19
Digital Door Lock COMMAX
CAUTION
Warning mischief and 1 minute stop function
Emergency Alarm Function
19
05
Heat Warining
When a fire is detected, a high temperature
of about suspected
(62℃±5)
,
automatically releases the locked state with
strong beeps for safety.
Remove battery or input [password]
or attach [smart key] , it will be turn
off warning and alarm.
※ it will be not turn off status in high
temperature of product.
Turn off heat warning
Turn off alarm
Intruder alarm
Abnormally in the door is locked(For example: forcely
open the gate) occurs when the door open condition is
detected Beep noise makes 80 db beeper.
If input not registered [password]
or [Smart Key] repeatedly
enteredfive times l stop operating
1 minutes with alarm.
Remove battery or input
[password] or attach [smart key] ,
it will be turn off.
Turn off alarm
Turn off alarm
?
?
?
?
?
?
?
?
?
?
?
?
?
?
?
?
?
?
?
?
?
?
?
?
?
?
?
?
?
?
?
?
?
?
?
?
?
CDL-2AR_도큐 2018.3.6 4:59 PM 페이지20
20
Emergency alarm function
05
Deadbolt(mortise) error alam
If sound alarm countinuos or not workging properly.
It required reallocation door lock position, please contact installer
or door lock professional company.
Opened or locked, when the dead bolt
(square clamp) of the indoor unit body
is normally taken out, or do not enter
"beep, beep beep, beep" warning sound
occurs three times.
Deadbolt
(Square clamp)
?
Battery Replacement Warning
Batter runs out completely, door cannot be opened.
Purchase 9V
battery in
5market.
1
Please touch
9v battery to
Emergency
Power supply
area.
2
Push
[ ] button.
3
Enter
[password]
4
And push
[ ] button
again.
5
Battery icon light on the Keypad
or make sound "bleek bleek bleek",
please change battery. all battery
change are required.
CDL-2AR_도큐 2018.3.6 4:59 PM 페이지21
Digital Door Lock COMMAX
NOTE
"beep, beep beep”
CAUTION
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22

Commax CDL-2AR/CDL-2ARC Owner's manual

Type
Owner's manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI