Rigol DP1116A User manual

Type
User manual
RIGOL
User’s Guide
DP1116A Programmable
DC Power Supply
Mar. 2010
RIGOL Technologies, Inc.
RIGOL
User’s Guide for DP1116A
I
Guaranty and Declaration
Copyright
© 2010 RIGOL Technologies, Inc. All Rights Reserved.
Trademark Information
RIGOL is a registered trademark of RIGOL Technologies, Inc.
Notices
RIGOL products are protected by patent law in and outside of P.R.C.
RIGOL Technologies, Inc. reserves the right to modify or change parts of or all
the specifications and pricing policies at company’s sole decision.
Information in this publication replaces all previously corresponding material.
RIGOL shall not be liable for losses caused by either incidental or consequential
in connection with the furnishing, use or performance of this manual as well as
any information contained.
Any part of this document is forbidden to copy or photocopy or rearrange
without prior written approval of RIGOL.
Product Certification
RIGOL guarantees this product conforms to the national and industrial standards in
China. International standard conformance certification is in progress, e.g. ISO.
Contact Us
If you have any problem or requirement when using our products, please contact
RIGOL Technologies, Inc. or your local distributors, or visit: www.rigol.com.
RIGOL
User’s Guide for DP1116A
II
Safety Notices
General Considerations
Please review the following safety precautions carefully before putting your
instrument into operation so as to avoid any personal injuries or damages to the
instrument and any product connected to it. To prevent potential hazards, please use
the instrument in compliance with regulations of this manual.
Use Proper Power Cord
Only the power cord designed for the instrument and authorized by local country
could be used.
Ground the Instrument
The instrument is grounded through the Protective Earth lead of the power cord. To
avoid electric shock, it is essential to connect the earth terminal of the power cord to
the Protective Earth terminal before any inputs or outputs.
Connect Test Leads Correctly
The test leads must be connected in strict accordance with regulations in this guide.
Observe all Terminal Ratings
To avoid fire or shock hazard, observe all ratings and markers on the instrument and
check your manual for more information about ratings before connecting.
Use Proper Overvoltage Protection
Make sure that no overvoltage (such as those caused by a thunderstorm) can reach
the product, or else the operator might expose to danger of electrical shock.
Do Not Operate Without Covers
Do not operate the instrument with covers or panels removed.
Use Proper Fuse
Please use the specified fuses.
Avoid Circuit or Wire Exposure
RIGOL
User’s Guide for DP1116A
III
Do not touch exposed junctions and components when the unit is powered.
Do Not Operate With Suspected Failures
If you suspect damage occurs to the instrument, have it inspected by qualified service
personnel before further operations. Any maintenance, adjustment or replacement
especially to circuits or accessories must be performed by RIGOL authorized
personnel.
Keep Well Ventilated
Inadequate ventilation may cause an increase of temperature or damage to the
device. So please keep well ventilated and inspect the intake and fan regularly.
Do Not Operate in Wet Conditions
In order to avoid short circuiting to the interior of the device or electric shock, please
do not operate in a humid environment.
Do Not Operate in an Explosive Atmosphere
In order to avoid damages to the device or personal injuries, it is important to
operate the device away from an explosive atmosphere.
Keep Product Surfaces Clean and Dry
To avoid the influence of dust or moisture in air, please keep the surface of device
clean and dry.
Electrostatic Prevention
Operate in an electrostatic discharge protective area environment to avoid damages
induced by static discharges. Always ground both the internal and external
conductors of the cable to release static before connecting.
Handling Safety
Please handle with care during transportation to avoid damages to buttons, knob,
interfaces and other parts on the panels.
RIGOL
User’s Guide for DP1116A
IV
Safety Terms and Symbols
Terms in this Manual. These terms may appear in this manual:
WARNING
Warning statements indicate the conditions or practices that could result in
injury or loss of life.
CAUTION
Caution statements indicate the conditions or practices that could result in
damage to this product or other property.
Terms on the Product. These terms may appear on the product:
DANGER indicates an injury or hazard may immediately happen.
WARNING indicates an injury or hazard may be accessible potentially.
CAUTION indicates a potential damage to the instrument or other property might
occur.
Symbols on the Product. These symbols may appear on the product:
Hazardous
Voltage
Refer to
Instructions
Protective
Earth
Terminal
Test
Ground
RIGOL
User’s Guide for DP1116A
V
Environment Considerations
The following symbol indicates that this product complies with the applicable
European Union requirements according to Directives 2002/96/EC on waste electrical
and electronic equipment (WEEE) and batteries.
Product End-of-Life Handling
The equipment may contain substances that could be harmful to the environment or
human health. In order to avoid release of such substances into the environment and
harmful to human health, we encourage you to recycle this product in an appropriate
system that will ensure that most of the materials are reused or recycled
appropriately. Please contact your local authorities for disposal or recycling
information.
RIGOL
User’s Guide for DP1116A
VI
DP1116A Overview
RIGOL DP1116A is a single channel Programmable DC Power Supply with up to
160W power and two scales output. The excellent performance provided by this unit
ensures a more pure and stable output from itself. Besides, the friendly, clear user
interface and a variety of configuration interfaces as well as plenty of standard
interfaces bring you more conveniences in actual use.
Main Features:
4.3 inch, 16 M true color TFT LCD.
Single voltage/current output in two scales: 16 V/10 A or 32 V/5 A.
Low ripples noise: < 350 μVrms/3 mVpp.
Excellent line regulation rate: < 0.01% + 2 mV (voltage), < 0.01% + 250 μA
(current).
Excellent load regulation rate: < 0.01% + 2 mV (voltage), < 0.005% + 250 μA
(current).
Overvoltage/Overcurrent protection functions, which can effectively guarantee
the load connected to the instrument by specifying proper overvoltage and or
overcurrent parameters.
Two-level overtemperature protection function.
Store and recall system setups.
Timing output function, which can support up to 100 groups of timing settings
and infinite or specified number of cycles output.
Waveform display function, which can display the output voltage, current and
power waveforms in real time so that the output status of the instrument
become clear for users in co-operation with the digital parameters shown near
the waveforms.
Classic display mode: dial plates, classical pointer, clear variation tendency of the
voltage, current and power.
Standard interfaces: USB Device, USB Host, LAN and GPIB (IEEE-488).
Support USB flash device storage.
Support remote control via Web.
Support remote control via SCPI commands.
Conform to LXI-C class instrument standards (version 1.2).
Support the built-in help.
Support panel lock.
Support Chinese & English interfaces and input.
RIGOL
User’s Guide for DP1116A
VII
Structure of this Document
Chapter 1 Quick Start
This chapter introduces you the panels and display interface as well as some
considerations on first use of DP1116A.
Chapter 2 Front Panel Reference
This chapter gives the detailed information on function and operating methods of
each key on the front panel.
Chapter 3 Remote Control
This chapter guide you how to control the DP1116A through the remote interfaces.
Chapter 4 Troubleshooting
This chapter offers some methods to help you solve the possible problems during
operations.
Chapter 5 Specifications
This chapter lists the specifications of DP1116A.
Chapter 6 Appendix
Information about accessories, services and supports and the like.
Hint:
For the newest version of this manual please download from this URL:
http://www.rigol.com
The representations of panel keys and menu softkeys of the instrument in
this book are:
Panel key: key characters + text box, such as 16V/10A denotes the selection key
of 16V/10A scale.
Menu softkey: menu characters + shading, for example: Volt denotes the voltage
option under the channel setting menu.
RIGOL
User’s Guide for DP1116A
VIII
Contents
Guaranty and Declaration ............................................................................ I
Safety Notices ............................................................................................. II
General Considerations ................................................................................ II
Safety Terms and Symbols .......................................................................... IV
Environment Considerations .......................................................................... V
DP1116A Overview .................................................................................... VI
Structure of this Document ..................................................................... VII
Chapter 1 Quick Start ............................................................................ 1-1
General Inspection .................................................................................... 1-2
Front/Rear Panel and User Interface ........................................................... 1-3
Front Panel ........................................................................................ 1-3
Rear Panel ......................................................................................... 1-6
User Interface .................................................................................... 1-7
First Use of DP1116A ................................................................................. 1-8
Power Requirements ........................................................................... 1-8
Power-On Check ................................................................................. 1-9
Output Inspection ............................................................................. 1-10
Display Mode .......................................................................................... 1-12
Chapter 2 Front Panel Reference .......................................................... 2-1
Parameter Input ........................................................................................ 2-2
Constant Voltage Output ............................................................................ 2-5
Constant Current Output ............................................................................ 2-8
Overvoltage/Overcurrent Protection ............................................................ 2-9
Timing Output ......................................................................................... 2-14
Remote Voltage Sensing .......................................................................... 2-17
Store and Recall ...................................................................................... 2-19
Utility Settings ......................................................................................... 2-23
I/O Settings ..................................................................................... 2-24
System Settings ................................................................................ 2-27
Calibrate .......................................................................................... 2-32
Timer Setting ................................................................................... 2-33
Built-in Help ............................................................................................ 2-35
Key Lock ................................................................................................. 2-36
RIGOL
User’s Guide for DP1116A
IX
Chapter 3 Remote Control ..................................................................... 3-1
Web Control .............................................................................................. 3-1
Command Control ..................................................................................... 3-5
Chapter 4 Troubleshooting .................................................................... 4-1
Chapter 5 Specifications ........................................................................ 5-1
Chapter 6 Appendix ............................................................................... 6-1
Appendix A: Accessories ............................................................................ 6-1
Appendix B: Warranty ................................................................................ 6-2
Appendix C: General Care and Cleaning ...................................................... 6-3
Index ........................................................................................................... 1
Chapter 1 Quick Start RIGOL
User’s Guide for DP1116A
1-1
Chapter 1 Quick Start
This chapter introduces the front/rear panel, the user interface and announcements
during first use of the instrument as well as its display mode.
Subjects in this chapter:
General Inspection
Front/Rear Panel and User Interface
Front Panel
Rear Panel
User Interface
First Use of DP1116A
Power Requirements
Power-On
Output Inspection
Display Mode
RIGOL Chapter 1 Quick Start
User’s Guide for DP1116A
1-2
General Inspection
Please inspect your new DP1116A according to the following steps:
1 Inspect the shipping container for damage
Keep the damaged shipping container or cushioning material until the contents
of the shipment have been checked for completeness and the instrument has
passed both electrical and mechanical tests.
The consigner or carrier shall be liable for the damage to instrument resulting
from shipment. RIGOL would not be responsible for free maintenance/rework
or replacement of the unit.
2 Inspect the instrument
In case of any damage, or defect, or failure, notify your RIGOL Sales
Representative.
3 Check the accessories
The accessories supplied with the instrument are listed in Appendix A:
Accessories. If your contents are incomplete or damaged, please notify your
RIGOL Sales Representative.
Chapter 1 Quick Start RIGOL
User’s Guide for DP1116A
1-3
Front/Rear Panel and User Interface
Front Panel
Figure 1-1 Front panel overview
No.
Name
Explanations
LCD
Display the user interface
Parameter input
area
Include the numeric keys, unit keys (direction keys)
and enter key
Power button
Turn on (or off) the instrument
USB Host port
Connect with an external USB device as the host
device
Menu key
With different functions in difference menus
Display modes
key
Switch the display mode between General Display
Mode and Classic Display Mode
Scale key
Switch the channel scale, enable/disable the channel
output
Output terminal
Channel output connectors
Advanced
function area
Wave Disp: display the output signal with
waveforms
RIGOL Chapter 1 Quick Start
User’s Guide for DP1116A
1-4
Store/Recall: store and recall the instrument
settings
Timer: control the timing output
Utility: set the associated system parameters
Sense: enable the Sense working mode
Help: enable the built-in help system
1. Panel-key indicator
The indicator will be lighted and the instrument will be started after you
press this button.
16V/10A, 32V/5A The associated characters below the scale key will be
highlighted after you press a scale key.
On/Off The character below this key will be highlighted after you turn on the
channel.
Wave Disp The indicator will be lighted after you turn on the waveform display.
Timer The indicator will be lighted after you turn on the timer.
Store/Recall The indicator will be lighted after you enter the Store and
Recall menu.
Utility The indicator will be lighted after you enter the system setting menu.
Help The indicator will be lighted after you enable the built-in help system.
2. Front panel connectors
No.
Name
Explanations
USB Host
Connect as a main unitwith an external USB device
such as USB flash devices.
Chapter 1 Quick Start RIGOL
User’s Guide for DP1116A
1-5
Sense terminal
Compensate the voltage drop.
Power output
terminals
Output the power supply.
Earth terminal
This terminal is connected with the chassis and ground
wire (grounded through the power cord) and can be
used as an additional ground terminal for other devices
when the instrument is power on.
RIGOL Chapter 1 Quick Start
User’s Guide for DP1116A
1-6
Rear Panel
Figure 1-2 Rear panel overview
No.
Name
Explanations
GPIB port
Conform to the IEEE 488.2 protocol.
Fan
Air outlet.
Supply hub
AC power inlet.
Power voltage
selector
Select a proper scale according to the input
voltage manually.
LAN port
Access to LAN through a RJ45 interface.
USB device port
Connect as a slave devicewith an external USB
device.
Fuse
Provided with two types of specifications: 250 V,
T4 A and 250 V, T2.5 A.
Power switch
Power on or cut off the power supply.
Chapter 1 Quick Start RIGOL
User’s Guide for DP1116A
1-7
User Interface
Figure 1-3 User interface of DP1116A
No.
Explanations.
No.
Explanations.
Active channel
Help system identifier
Channel status
Beeper identifier
Actual output *
Voltage/current input box
LAN connection identifier
O.V.P status setting box
Keylock
O.V.P input box
Self-test failed
O.C.P status setting box
O.T.P identifier
O.C.P input box
Remote control identifier
Operation menu
USB device identifier
*Remark: This area displays the actual output values of voltage, current and power as well as
the identifier of Sense, CC (constant current) or CV(constant voltage).
NOTE
The DP1116A has three display modes and each mode has its own interface,
for more details please refer to Display Mode.
⑦ ⑧
RIGOL Chapter 1 Quick Start
User’s Guide for DP1116A
1-8
First Use of DP1116A
Prior to making any connections to the instrument, read the section of General
Inspection carefully to avoid any possible or potential dangers and carry out
necessary check and inspections following the requirements below when you first
use the DP1116A.
Power Requirements
Use the power cord that is specifically designed for the DP1116A to connect the
instrument and the AC power which delivers 100 V, 115 V, 220 V or 230 V, 50 Hz to 60
Hz. Users should select a voltage scale that meets the standards in their own country
through the Power voltage selector (see Figure 1-2) at the rear panel and use an
appropriate fuse.
Note:
250 V, T4 A fuse: 100 V and 115 V
250 V, T2.5 A fuse: 220 V and 230 V
To change the voltage scale of the instrument, please:
1. Turn off the power switch/button at the front/rear panel and remove the power
cord.
2. Check if the fuse installed before leaving factory (250 V, T2.5 A) can match with
the selected voltage scale; if not, change it.
3. Regulate the voltage selector to a desired scale using a straight screwdriver.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85

Rigol DP1116A User manual

Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI