Giacomini KFC-F User manual

Type
User manual
KFC-F Installation and user manual
10/2023
Fan coil for in-oor installation
Installation and
user manual
Giacomini S.p.A.
Via per Alzo 39, 28017 San Maurizio d’Opaglio (NO) Italy
+39 0322 923372 - giacomini.com
Giacomini S.p.A.
Via per Alzo 39, 28017 San Maurizio d’Opaglio (NO) Italy
+39 0322 923372 - giacomini.com
32
TABLE OF CONTENTS
1 General information � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � p.6
1.1 About the manual . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . p.6
1.1.1 Editorial pictograms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . p.6
1.1.2 Pictograms on the product . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . p.6
1.1.3 Recipients . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . p.6
1.1.4 Manual organisation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . p.6
1.2 General warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . p.7
1.3 Basic rules of security . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . p.7
1.4 Disposal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . p.8
2 Product presentation � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � p.9
2.1 Destination of use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . p.9
2.2 Description of the appliance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . p.9
2.3 Compatible accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . p.10
3 Installation � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � p.12
3.1 Preliminary warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . p.12
3.2 Reception . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . p.12
3.2.1 Preliminary warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . p.12
3.2.2 Package description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . p.12
3.3 Dimensions and weights with packaging . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . p.12
3.4 Installation site . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . p.13
3.5 Installation mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . p.13
3.6 Installation minimum distances . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . p.13
3.7 Device preparation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . p.14
3.8 Installation arrangement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . p.14
3.9 Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . p.16
3.10 Hydraulic connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . p.17
3.10.1 Position and dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . p.17
3.10.2 Connection to the system . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .p.18
3.10.3 Hydraulic accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . p.18
3.10.4 Connection with manual 2-way valve . . . . . . . . . . . . . . . . . . . . . . . . . . . . . p.18
3.10.5 Connection with 2-way valve and thermoelectric actuator . . . . . . . . . . . . . . . . . . . .p.18
3.11 Condensate drain . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . p.19
3.11.1 Connection to the condensate drain . . . . . . . . . . . . . . . . . . . . . . . . . . . . . p.19
3.11.2 Check . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . p.19
3.12 Filling the system . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . p.20
3.13 Electric connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . p.20
3.13.1 Access to the terminal block . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . p.21
3.14 Diagrams and configurations electrical controls . . . . . . . . . . . . . . . . . . . . . . . . . . . p.22
3.14.1 Remotecontrolwithxedspeed . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .p.22
3.14.2 Remote control with modulating speed . . . . . . . . . . . . . . . . . . . . . . . . . . . .p.24
Markings
First of all, we would like to thank you for having chosen our product.
We are sure you will be happy with it because it represents the state of the art in the technology
of home air conditioning.
By following the suggestions contained in this manual, the product that you have purchased
will operate without problems giving you optimum room temperatures with minimum energy
costs.
Giacomini S.p.A.
Conformity
This unit complies with the European directives:
Low voltage 2014/35 / EU;
Electromagnetic compatibility 2014/30 / EU;
RoHS Directive 2011/65/EU;
54
4 Maintenance � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � p.26
4.1 Routine maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . p.26
4.2 Six-monthly operations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . p.26
4.2.1 Externalcleaning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . p.26
4.2.2 Airintakeltercleaning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . p.26
4.2.3 Filterextraction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . p.26
4.2.4 Cleaning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . p.27
4.2.5 Insertingthelter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . p.27
4.3 Suggestions for energy saving . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . p.27
5 Troubleshooting � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � p.28
5.1 Preliminary warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . p.28
5.2 Troubleshooting table . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . p.28
6 Technical information� � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � p.29
6.1 Technical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . p.29
6.2 Overall dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . p.30
76
GENERAL INFORMATION GENERAL INFORMATION
GENERAL INFORMATION
1�1 About the manual
Thismanualwaswrittentoprovidealltheexplanationsfor
thecorrectmanagementoftheappliance.
This instruction manual forms an integral part of the
deviceandthereforemustbecarefullypreservedand
mustALWAYStravelwithit,evenifyoutransferthede-
vice to another owner or relocate it to other premises.
Ifthemanualgetsdamagedorlost,downloadacopy
fromthewebsite.
Readthismanualcarefullybeforeproceedingwithany
operationandfollowtheinstructionsin theindividual
chapters.
The manufacturer is not responsible for damages to
personsorpropertycausedbyfailuretofollowthein-
structions in this manual.
Thisdocumentisrestrictedinusetothetermsofthe
lawandmaynotbecopiedortransferredtothirdpar-
tieswithouttheexpressauthorizationofthemanufac-
turer.
1�1�1 Editorial pictograms
Thepictogramsinthenextchapterprovidethenecessary
informationforcorrect,safeuseofthemachineinarapid,
unmistakable way.
Related to security
High risk warning (bold text)
Theoperationdescribedabovepresentsariskofse-
riousphysicalinjury,fatality,majordamagetotheap-
plianceand/ortotheenvironmentifnotcarriedout
incompliancewithsafetyregulations.
Lowriskwarning(plaintext)
Theoperationdescribedabovepresentsariskofmi-
nor physical injury or minor damage to the appliance
and/ortotheenvironmentifnotcarriedoutincom-
pliancewithsafetyregulations.
Prohibition(plaintext)
Referstoprohibitedactions.
Important information (bold text)
This indicates important information that must be
taken into account during the operations.
In the texts
– procedures
actions required
Expected responses following an action.
lists
Inthegures
1 The numbers indicate the individual components.
A The capital letters indicate component assemblies.
1 The white numbers in black marks indicate a se-
riesofactionstobecarriedoutinsequence.
A
 Theblackletterinwhiteidentiesanimagewhen
thereareseveralimagesinthesamegure.
1�1�2 Pictograms on the product
Symbolsareusedinsomepartsoftheappliance:
Related to security
Caution: electrical danger
The concerned personnel is informed to the pres-
enceofelectricityandtheriskofsueringanelectric
shock.
1�1�3 Recipients
User
Non-expert person capable of operating the product in
safe conditions for people, for the product itself and the
environment, interpreting an elementary diagnostic of
faults and abnormal operating conditions, carrying out
simple adjustment, checking and maintenance operations.
Installer
Expert person qualied to position and connect (hydrau-
lically,electrically,etc.)theunittotheplant;thispersonis
responsibleforhandlingandcorrectinstallationaccording
to the instructions provided in this manual and the national
standardscurrentlyinforce.
Toworkontherefrigerationcircuit,theinstallermustcom-
ply with the provisions of Regulation 303/2008/EC which
denes,inaccordancewithDirective842/2006/EC,there-
quirements for companies and personnel with regard to
xedrefrigeration,airconditioningandheatpumpequip-
ment containing certain uorinated greenhouse gases
(F-gaslicence).
Technical Service Centre
Expert and qualied person authorised directly by the
manufacturer to carry out all routine and supplementa-
ry maintenance operations, as well as every adjustment,
check, repair and replacement of parts necessary during
thelifeoftheunititself.
ServicepersonnelmustcomplywiththeprovisionsofReg-
ulation303/2008/ECwhichdenes,inaccordancewithDi-
rective842/2006/EC,therequirementsforcompaniesand
personnelwithregardtoxedrefrigeration,aircondition-
ingandheatpumpequipmentcontainingcertainuorinat-
edgreenhousegases(F-gaslicence).
1�1�4 Manual organisation
The manual is divided into sections each dedicated to one
or more target groups.
General information
It addresses all recipients.
It contains general information and important warnings
thatshouldbeknownbeforeinstallingandusingtheap-
pliance.
Product presentation
It addresses all recipients.
Itcontainstheinformationtoidentifytheproduct,itscom-
ponents,compatibleaccessoriesanddestinationofuse.
Installation
Itisaddressedexclusivelytotheinstaller.
Itcontains specic warningsand all theinformation nec-
essary for positioning, mounting and connecting the ap-
pliance.
Commissioning, maintenance and troubleshooting
TheyareaddressedexclusivelytotheTechnicalAssistance
Centre.
It contains specic warnings useful information for the
most common commissioning and routine maintenance.
Technical information
It addresses all recipients.
Itcontainsdetailedtechnicalinformationabouttheappli-
ance.
1�2 General warnings
Specicwarningsaregivenineachchapterofthedocu-
mentandmustbereadbeforestartingoperations.
Allpersonnelinvolvedmustbeawareoftheoperations
and dangers that may arise when beginning all unit in-
stallation operations.
Installation performed outside the warnings provided
inthismanualanduseoftheapplianceoutsidethepre-
scribed temperature limits will invalidate the warranty.
The installation and maintenance of climate control
equipment could be dangerous because there is live
electrical components inside the appliances. The in-
stallation, initial start-up and subsequent maintenance
phases must be carried out exclusively by authorised
andqualiedpersonnel(seerststart-uprequestform
enclosedwiththeappliance).
Anycontractualorextra-contractualliabilityfordamage
caused to persons, animals or property, due to installa-
tion, adjustment and maintenance errors or improper
useisexcluded.Allusesnotexpresslyindicatedinthis
manual are not permitted.
Only qualied installer companies are authorised to
install the device. After having completed installation,
theinstallerwillissueadeclarationofconformitytothe
plant manager, as required by the applicable standards
and the guidelines provided by contractor's instruction
manual supplied with the device.
First start-up and repair or maintenance operations
must be carried out by the Technical Assistance Centre
orbyqualiedpersonnelfollowingtheprovisionsofthis
manual.
Donotmodifyortamperwiththeapplianceasthiscan
lead to dangerous situations.
Use suitable accident-prevention clothing and equip-
ment during installation and/or maintenance opera-
tions. The manufacturer is not liable for the non-ob-
servanceofthecurrentsafetyandaccidentprevention
regulations.
Intheeventofliquidoroilleaks,setthemasterswitch
oftheplantto"o"andclosethewatertaps.Callthe
authorised Technical Assistance Centre or profession-
allyqualiedpersonnelassoonaspossibleanddonot
workontheapplianceyourself.
Incaseofreplacementofparts,useonlyoriginalparts.
Themanufacturerreservestherighttomakechanges
to its models at any time to improve its product, with-
out prejudice to the essential characteristics described
inthismanual.Themanufacturerisnotobligedtoadd
such modications to machines previously manufac-
tured, already delivered or under construction.
1�3 Basic rules of security
Pleasekeepinmindthattheuseofproductspoweredby
electricityandwatercallforoperatorstocomplywithcer-
tainessentialsafetyrules:
Theuseoftheappliancetochildrenandunassisteddis-
abled persons is prohibited.
It is forbidden to touch the device with wet or damp
body parts.
Itisforbiddentocarryoutanyoperationbeforediscon-
nectingtheappliancefromthepowersupplybysetting
theplantmasterswitchto"o".
Itisforbiddentomodifythesafetyoradjustmentde-
vicesoradjustwithoutauthorizationandindicationsof
themanufacturer.
Itisforbiddentopull,unplugortwistthedevice'selec-
triccables,evenifitisdisconnectedfromthemains.
It is forbidden to introduce objects and substances
through the air inlet and outlet grilles.
Itisforbiddentoopentheaccessdoorsofthedevice's
internalpartswithoutrsthavingsetmainswitchofthe
systemto"o".
It is forbidden to dispose of, or leave in the reach of
children, the packaging materials which could become
asourceofdanger.
98
GENERAL INFORMATION PRODUCT PRESENTATION
PRODUCT PRESENTATION
2�1 Destination of use
These appliances have been designed for conditioning
and/orheatingroomsandtheymustbedestinedsolelyfor
thispurpose,inaccordancewith their performancechar-
acteristics.
2�2 Description of the appliance
KFC-Ffancoilsrangearedesignedforoorinstallation.
The device are are made in three dierent performance
levelsandsize,allfortwo-pipeconguration.
KFC-Ffancoilsrangeareavailableintotwocongurations
based on control mode:
forconnectionwithremotecontrolatxedspeed
for0-10Vconnectionatmodulatingspeed
1�4 Disposal
The symbol on the product or its packaging indicates that
the product must not be treated as normal household
waste, but must be taken to the appropriate collection
point for the recycling of electrical and electronic equip-
ment.
Proper disposal of this product avoids harm to humans
andtheenvironmentandpromotesthereuseofvaluable
raw materials.
Formoredetailedinformationabouttherecyclingof this
product, contact your local city oce, your household
waste disposal service or the shop where you purchased
the product.
Illegaldisposaloftheproductbytheuserinvolvestheap-
plicationoftheadministrativesanctionsprovidedforbythe
regulationsinforce.
This provision is only valid in the EU Member States.
Avoiddisassemblingtheunityourself.
This unit contains uorinated greenhouse gases cov-
ered by the Kyoto Protocol. Maintenance and disposal
operationsmustbecarriedoutbyqualiedpersonnel
only.
Contact an authorised Technical Assistance Cen-
tre to disassemble the appliance.
1110
PRODUCT PRESENTATION PRODUCT PRESENTATION
2�3 Compatible accessories
Accessory description Combinable products Code
Hydraulic kit
HYDRAULIC KIT
Couple of EUROKONUS adapters for 1/2” female connection
(male ttings) All T.B.D.
Couple of EUROKONUS adapters for 3/4” female connection
(male ttings All T.B.D.
90° bended EUROKONUS connector All T.B.D.
Distancer kit ( 1 piece) All T.B.D.
Adaptors for at ring All T.B.D.
2 way valve group with manual closure KFC-WD XL T.B.D.
KFC-WD T.B.D.
2 way valve group (water inlet valve, shut o valve and electro
thermal motor) KFC-WD XL T.B.D.
2 way valve group (water inlet valve, shut o valve and electro
thermal motor) KFC-WD T.B.D.
Electronic devices
Thermostat
Wi-Fi thermostat, with temperature and humidity probe, xed
speed Tutti K492TY002
Wi-Fi thermostat, with temperature and humidity probe, three
speeds Tutti K492TY012
Wi-Fi thermostat with temperature and humidity probe
+ BUS regulation unit Tutti K493TWY002
+ KPM30
1312
INSTALLATION INSTALLATION
INSTALLATION
3�1 Preliminary warnings
For detailed information on the products, refer to
chapter "Technical information" p.29.
The installation must be carried out by the installer.
Thereisariskofwaterleakage,electricshockorreif
theinstallationisnotperformedcorrectly.
During the installation, it is necessary to observe the
precautions mentioned in this manual, and on the la-
bels placed inside the equipment, as well as to adopt
any precaution suggested by common sense and by the
SafetyRegulationsinforceintheplaceofinstallation.
Be sure to use the supplied or specied installation
parts.Useofotherpartsmaycausetheunittocometo
lose,waterleakage,electricalshock,orre.
Failuretoapplytheindicatedrulesmaycausemalfunc-
tionsofthe appliancesandrelievesthemanufacturer
fromanywarrantyandfromanydamagecausedtoper-
sons, animals or property.
3�2 Reception
3�2�1 Preliminary warnings
Uponreceiptofthepackagecheckthatitisnotdam-
aged, otherwise accept the goods with reserve, produc-
ingphotographicevidenceofanydamage.
Intheeventofdamage,notifytheshipperwithin3days
ofreceiptofanydamagebyregisteredmailwithreturn
receipt, submitting photographic evidence. Similar in-
formation should be sent by fax to the manufacturer
(jurisdictionwillbeattheCourtTrentoforanydispute).
Nonoticeofdamagewillbeacceptedafter3daysfrom
delivery.
Unpack and check the contents against the packing list.
3�2�2 Package description
Thepackagingismadeofsuitablematerialandcarriedout
byexperiencedpersonnel.
All units are checked and tested and are delivered com-
pleteandinperfectconditions.
The appliance is shipped in standard packaging consisting
ofacardboardsleeveandasetofexpandedpolystyrene
protectors.
3�3 Dimensions and weights with packaging
L
P
H
Models m.u. 400 600 800
Dimensions and weight for shopping
Total widh mm 1020 1220 1320
Total height mm 490 490 490
Total depth mm 213 213 213
Weight kg 15,0 17,0 20,0
3�4 Installation site
Positionofdevicemustbeestablishedbythesystemde-
signeror otherqualied professionaland musttake into
account both technical requirements and any local laws in
force.
KFC-F fancoil has to be installed only in horizontal po-
sition on the oor.
Avoid installing the unit near:
areasexposedtodirectsunlight
nearheatsources,exceptforsolarradiationsltered
by glass
wet rooms and areas in which the unit can come into
contact with water
rooms with oil vapors
roomssubjecttohighfrequencies
Make sure that:
the oorisable tosupport the weightof theappli-
ance.
the oor is not crossed by pipelines, load-bearing
construction elements or power lines
thesurfaceisperfectlylevelled
there are no obstructions nearby that could compro-
misetheinletandoutletairow
the installation position is suitable to allow conden-
sate drain outside the
the installation position is optimal to avoid that the
airowisdirectedtowardspeople
3�5 Installation mode
The assembly steps described below and their drawings
refertoaversionofthemachinewithconnectionsonthe
right side.
Foridealinstallationandperformance levels,carefully
followtheinstructionsinthemanual.
Failure to do so may cause system malfunctions and
automatically voids the warranty, and relieves the con-
structor of any harm caused to person, animals or
property.
3�6 Installation minimum distances
Thegureshowstheminimuminstallationdistancesofthe
unit.
Itisimportanttoensurethattheairowisnotocclud-
ed by walls or obstacles.
1514
INSTALLATION INSTALLATION
20 mm 20 mm
100 mm
You can install several devices in succession. In this
case it is not necessary to keep the minimum distances
between one unit and the other.
20 mm 20 mm
100 mm
3�7 Device preparation
The device is supplied with the installation accessories:
metal casing cover grid
3�8 Installation arrangement
Toinstalltheunit,preparetheooringforthehousingof
the metal casing.
Makesurethattheoorisabletosupporttheweight
oftheappliance.
Make sure that the oor is not crossed by pipelines,
load-bearing construction elements or power lines.
A oor
B housingofmetalcasing
A
B
The side of the connections must be understood as
shown below, with connections on the right part (stand-
ard).
A electric connections
B airoutowside(outlet)
C airintakeside(inlet)
D sideofcondensatedrainandhydraulicconnections
E Wall
A
B
D
C
E
Preparethemetalcasefortheconnections
identifythecondensatedrainsideandhydrauliccon-
nection side
apply the supplied metal bar on the side opposite to
the side hydraulic connections and condensate drain
– secure the metal bar
A Predispositionforconnectionsontheleft,sideview
B Predispositionforconnectionsontheleft,longitudinalview
C Predispositionforconnectionsontheright,sideview
D Predispositionforconnectionsontheright,sideview
E Condensate drain hydraulic connections SX
F Condensate drain hydraulic connections DX
G Metalbarfortilttowardhydraulicparts
Indietro1
Davanti1
E
AB
E F
C
D
F
E
G
Depending on the side of the hydraulic connections,
bring the supply hoses so that they come out of the
correct pre-punching.
Make sure to place the bar correctly on the opposite
sideofthecondensatedrain.Thiswillallowthedeviceto
beslightlytilted,facilitatingthecondensatedischarge.
Make a siphon to prevent bad smells returning up the
pipetowardstheroom.Thecurveofthesiphonmust
be lower than the condensation collection pan.
Payattentiontotheheightandslopeofthedrainpipe,
which must be constant.
1716
INSTALLATION INSTALLATION
3�9 Installation
Install the metal casing
A oor
B metal casing
A
B
– insert the metal casing in the space provided
positionit7mmbelowthenishedoorlevel
xthemetalcasing
Besuretoplacethemetalcasing7mmbelowtheoor
level.Thusupperthegridwillremainatoor-level.
A 7mmbelowtheedgeofthenishedexternaloor
B metal casing
B
A
Insert the fancoil
insertthefancoilinsidethemetalcasing
– making the connections
Make sure that the air supply is facing in the correct
direction.
Make sure that the side connections and the conden-
sate drain are correctly positioned.
A oor
B unit body
A
B
Insert the grid
– insert the grid
Itisnecessary,forrightfunctioningofthedevice,that
during the whole installation phase the working space
remains clean.
Regularlyclearawaywasteocuts,debrisordirtinthe
metal casing.
A Grid
A
3�10 Hydraulic connections
The engineer is responsible for choosing the right water
lines and their size, in accordance with good installation
practices and the applicable law.
Keep in mind that undersized pipelines lead to poor
systemoperationand/oralossofthermalandcooling
performance.
Toaccessthespaceofthehydraulicconnections:
unscrewthexingscrew
– remove the protective cover plate
A xingscrews
B cover plate
C hydraulic connections
B
A
C
3�10�1 Position and dimensions
KFC-F
Models m.u. 400 600 800
Pipelines minimum diameter mm 14 16 16
1918
INSTALLATION INSTALLATION
3�10�2 Connection to the system
To make the connections:
– hydraulic lines positioning
usethe"wrenchbackupwrench"method
– tighten the connections
checkforleaks
– coat the connections with insulating material
Thehydrauliclinesandttingsmustbethermallyinsu-
lated.
Avoidpartialinsulationofthepipes.
Avoid over-tightening the pipes to avoid damage to the
insulation.
Carefullycheckthattheinsulation istight,in orderto
preventthemakinganddrippingofcondensate.
3�10�3 Hydraulic accessories
Normally,unitcomeswithoutanyshut-ovalve. In othercase, dependingof therequest,the unitcan be
supplied with valves already assembled or supplied sepa-
rately to be mounted during installation.
3�10�4 Connection with manual 2-way valve (T�B�D�)
Incaseofchoiceforthe2-waymanualvalve:
no electrical connection are necessary
simplyconnectthepipelineasshowninthegure
images for illustration purposes only
3�10�5 Connection with 2-way valve and thermoelectric actuator (T�B�D�)
In case of choice for the 2-way valve and thermoelectric
actuator:
connectthepipelineasshowninthegure
A electriccableentryholeforthermoelectricactuator
B thermoelectric actuator
A
B
images for illustration purposes only
3�11 Condensate drain
Thisapplianceiscompletewithatrayforcollectingthecon-
densation produced during cooling operation and which
mustbechannelledtoasuitableplacefordrainage.
A drain connection
B outletofdrainagetube
A
B
3�11�1 Connection to the condensate drain
– connect a rubber drainage tube
directittoasuitableplacefordropping
– provide a slope never less than 1%
insulatettingpoints
Payattentiontothetiltofthecondensatedrainpipe.
Makethecondensateliquidowdirectly intoa"white
water".
Make a siphon to prevent bad smells returning up the
pipetowardstheroom.Thecurveofthesiphonmust
be lower than the condensation collection pan.
Installapumpifthedrainpipeishigherthanlowerlevel
ofpan.
A the drainage tube
A
A the drainage tube
A
3�11�2 Check
Aftertheinstallationiscompleted:
pour the water very slowly into the condensate drain
pan
checktherightoutow
2120
INSTALLATION INSTALLATION
3�12 Filling the system
Tollthesystem:
– open the vent valves
openallthesystem'sshut-odevices
– slowly open the water tap
Whenwaterbeginstoleakoutofthebreathervalves:
– close the breather valves
completesystemlling
verifythatyouhavereachedthenominalpressurefor
the system
– close the water tap
checkthetightnessofthegaskets
It is recommended to repeat this operation after the
devicehasbeenrunningforafewhours.
Regularly check the system's pressure.
Keep the system bleed during operation, penalty, loss
ofperformanceandenergyconsumption.
A ventingofthebattery
A
3�13 Electric connections
Thedeviceleavesthefactoryfullywiredupandneedsonly
the connection to the power supply, to any controls and
accessories.
Forthesizeofthepowersupplycableandsafetydevices,
usethefollowingtable.
KFC-F
Models m.u. 400 600 800
Power conductor (phase+neu-
tral) mm² 1,5 1,5 1,5
protective conductor section on
ground mm² 1,5 1,5 1,5
Circuit breaker A 2 2 2
1. Note: The values indicated refer to a maximum length of the lines equal to
30 m.
Make sure that:
thecharacteristicsoftheelectricnetworkareadapt-
ed to the absorption of the apparatus, considering
also any other devices in parallel operation
the power supply voltage and system frequency
match to the values indicated on the device's plate
data
thecablesmustbeappropriateforthetypeofinstal-
lation in accordance with the applicable IEC standards
the power supply is provide with protection against
overload and/or short-circuit
It is required:
connectthedeviceanecientgroundconnection
installadedicatedmainswitchttedwithtime-delay
fuseor with anautomatic circuitbreaker switch,in-
stalled near the device
The device is equipped with suppression lter as laid
down by the applicable laws and standards. Use selec-
tive circuit breakers to compensate for the micro-dis-
persiononthegroundofthisdevice.
If you need to replace the power cable, contact only
qualiedstaandincompliancewiththeapplicablena-
tional laws.
Openthemainswitchbeforemakingelectricalconnec-
tions or maintenance operations.
It is forbidden the use of gas and water pipes for
grounding the appliance.
3�13�1 Access to the terminal block
Beforedoinganywork,makesurethatthesupplypow-
er is disconnect.
To access the terminal block:
unscrewthexingscrewsofthecoverplate
– remove the cover plate
A Fixingscrews
B Cover plate
C Electricalbox
B
A
C
unscrewthexingscrewsoftheelectricbox
– open the cover
A Fixingscrews
B Coveroftheelectricalbox
C Terminal block
B
A
C
To connect the power supply:
– bring the power cord to the terminal block
– making the connections
refertotheinformationinthewiringdiagramofthe
unit you are installing
A terminalblockforwiring
2322
INSTALLATION INSTALLATION
3.14Diagramsandcongurationselectricalcontrols
3.14.1RemotecontrolwithxedspeedincombinationwithK492TY002(singlespeed)or
K493TWY002+KPM30(3speeds)
Printed circuit board
The PCB is included in the supply.
N-L 230V/50Hzelectricalpowersupply
EV Solenoid valve permission input
V1 Maximumfanspeed1.400rpm
V2 Mediumfanspeed1.100rpm
V3 Minimumfanspeed680rpm
V4 Super-silent speed 400 rpm
E Heating, cooling selection input
Y1 Watersolenoidvalve(230V/50Hz1Apoweroutput)
M1 Fan motor DC Inverter
TA 3speedroomthermostat(tobuy,installandconnectbytheinstaller)
CV Thermostat consent
SV Speed selector
H2* Watertemperatureprobe10kΩ
* Located in the battery on the unit.
N276660C
DATA I/O
LED
H4 H2
Connection with 3 speed thermostats
TheCVinputistheON/OFFoftheboard:
incaseofopenedinputthePCBisplacedinstand-by
incaseofclosedinputthePCBisinoperation
ToactivetheelectrovalveY1theCVinputmustbebridged
toclampLofthe230Velecticpowersupply.
To activate the fan, connect the V1, V2, V3, V4 inputs to
clampLofthe230Velectricpowersupply.Theinputscon-
trol the ventilation speed:
V1-maximumfanspeed(equalto1400rpm)
V2-mediumfanspeed(equalto1100rpm)
V3-minimumfanspeed(equalto680rpm)
V4-supersilentspeed(equalto400rpm)
Connectthe3speedsofthethermostattothreeofthefour
availableinputsbasedonthecharacteristicsanduseofthe
location.Examples:
residentialapplicationwheremaximumsilenceisre-
quired,connectV2,V3eV4
commercial application where the heating capacity is
themainaspect,connectV1,V2andV3
Intheeventofsimultaneousclosureofseveralinputs,the
motorwillrunatanumberofrevolutionsequaltothatset
by the connection with the highest speed.
You can connect several boards in parallel to a single ther-
mostat,evenusingdierentspeed.
Waterprobe
Incaseofconnectionwithelectromechanicalthermostats
or commercial commands provided with water probe:
the on-board H2 probe will not be connected
the device will be controlled from the remote com-
mand
Ifthisisnotthecase,connectthe10kΩprobelocatedin-
side the battery to the H2 connector on the PCB.
The printed circuit board works in:
minimum water temperature for heating function
(<30°C)
maximum water temperature for cooling function
(>20°C)
Incaseoftemperaturenotsuitableforactiveoperation:
the ventilation stops
erroris indicated by the ashing ofthe LED onthe
PCB
The Heating/Cooling discriminant is implemented through
theEST/INinputoftheboard:
with input open the boards goes into Heating mode
with input closed the board goes in Cooling mode
It is possible to use the device without the water probe ac-
tivated. In this case the error is signaled on led.
Toconrmoperationwithouttheprobe:
– disconnect and connect the board power
This condition is stored by the board for all subsequent
startups. Connect the probe to restore the normal func-
tions.
Error signals
LED signals
LEDo
The CV contact is open, stand-by condition
LED on
The CV contact is closed, normal operation
LED1ash/pause
Water temperature probe H2 alarm not suitable,
temporary stop of the ventilation until the tempera-
ture reaches an appropriate value
LED2ashes/pause
Motor alarm (for example jamming due to foreign
bodies or fault in the rotation sensor)
LED3ashes/pause
Water probe alarm disconnected or faulty
2524
INSTALLATION INSTALLATION
3.13.2RemotecontrolwithmodulatingspeedincombinationwithK492TY012
Printed circuit board
The PCB is included in the supply.
L-N 230V/50Hzelectricalpowersupply
10V Devicepilotinput0÷10V.Inputimpedance25kΩ
Y1 Watersolenoidvalve(230V/50Hz1Apoweroutput)
M1 Fan motor DC Inverter
N276659C
Connection with 0-10 V thermostats
The10VinputactivatessolenoidvalveY1andadjuststhe
numberofrotationsofthefan.Thespeedrangeprovides
alinearadjustmentfromtheminimumvalue(400rmp)to
themaximumvalue(1400rmp)forvoltagevalues1,1V
÷10VDC.
The solenoid valve Y1:
isenabledbyvoltagevalues>1VDC
turnsowithvalues<0,9VDC
Error signals
LED signals
LEDo
The input signal is below 0,9 V
LED on
Normal operation, the input signal is greater than
1 V
LED2ashes/pause
Motor alarm (for example jamming due to foreign
bodies or fault in the rotation sensor)
OFF
0
10 V
INPU
T
(V DC
)
M1
110
Y1
1,1
M
AX rpm
ON
0,9
MIN rpm
2726
MAINTENANCE MAINTENANCE
MAINTENANCE
4�1 Routine maintenance
Routine maintenance is essential to keep the device always
ecient,safeandreliableovertime.
Itcanbecarriedoutwithasix-monthlyperiodicity.
Before each cleaning and maintenance intervention:
disconnectthedevicefromthepowermainsbyturn-
ingthesystemmasterswitchto"OFF"
Waitforthecomponentstocooldowninordertoavoid
any burns.
After completing the maintenance work, must be re-
stored the original condition.
Itisforbiddentoopentheaccessdoorsandcarryout
any technical or cleaning intervention, before having
disconnectthedevicefromthemainssupplybyplacing
themainswitchofthesystemon"OFF".
4�2 Six-monthly operations
4�2�1 External cleaning
Clean the external surface of the grid using a soft cloth
dampened with water.
Avoid dripping water in the device.
Do not use abrasive sponges or abrasive or corrosive
detergentsasyoumightdamagethepaintedsurface.
4.2.2 Airintakeltercleaning
Cleaningtheltermustbecarriedout:
afterprolongedoperation,consideredtheconcentra-
tionofimpuritiesintheair,
whenyouplantorestartthesystemafterprolungate
disuse.
4�2�3 Filter extraction
Toextractthelter:
A Grid
B fancoilunit
A
B
removethegridbyliftingit
A Filter
B fancoilunit
B
A
removethelter
liftitslightly
rotateuntilthecompleteexitfromthehousing
removethelter
4�2�4 Cleaning
A Vacuumcleaner
B Filter
A
B
Tocleanthelters:
– to use a vacuum cleaner
– to aspirate dust
A Running water
B Filter
A
B
washthelterwithrunningwater
– allow it dry
Donotusedetergentsorsolventstocleanthelter.
4.2.5 Insertingthelter
Remountthelterpayingparticularattentiontointroduce
thelowerapinitshousing.
Afternishingthecleaningofthelter,checkthatthe
grid is mounted correctly.
Thedevicefeaturesasafetyswitchhatpreventsthefan
fromstartingifthemobilepanelisincorrectlymounted
orthelteraremissing.
Donotusethedevicewithoutitsmeshlter.
Itisforbiddentousethedevicewithoutitsmeshlter.
4�3 Suggestions for energy saving
Fora correctoperationof the deviceandagreatenergy
saving:
keeptheltersclean
keep the doors and windows of the locations tted
with air conditioning systems closed as much as pos-
sible
Duringsummerlimittheentryofdirectsunraysinto
theroomstobeair-conditionedbymeansofexternal
screens(projections,curtains,shutters,etc.)
2928
TROUBLESHOOTING TECHNICAL INFORMATION
TROUBLESHOOTING
5�1 Preliminary warnings
Shouldyouencounteranyoftheanomaliesbelow:
theventilationdoesnotstartevenifthewatercircuit
islledwithhotorcoldwater
the device is losing water in heating mode
the device is loosing water in cooling mode
thedevicegeneratesexcessivenoise
there is dew
Follow the instructions below:
disconnectthedevicefrompowersupplyimmediate-
ly
– close the water taps
contactimmediatelyanauthorizedtechnicalsupport
centerorqualiedsta
Theinterventionsmustbecarriedoutbyaqualiedin-
stallerorbyaspecializedsupportcenter.
Do not intervene personally.
5�2 Troubleshooting table
Eect Cause Solution
The ventilation is delayed with respect to the new
temperature or function settings.
The circuit valve requires a certain time to open and
therefore to make the hot or cold water circulate inside
the device.
Wait 2 or 3 minutes to allow the circuit valve to open.
The device does not activate the ventilation. Cold or hot water is missing from the system. Make sure the boiler or the water cooler are on.
The ventilation does not start even if the water circuit is
lled with hot or cold water.
The hydraulic valve stays closed.
Demount the body of the valve and check if the water
circulation is restored.
Check the valve operation feeding it separately to 230
V. If you were to turn on, the problem may be in the
electronic control.
The ventilation motor is jammed or burnt. Check the motor windings and check if the fan rotates
freely.
The wirings are not correct. Check the electrical connections.
The device is losing water in heating mode. Leaks at the hydraulic connections of the system. Check the leak and tighten the connection.
Losses in the valve group. Check the condition of the gaskets.
There are water drops on the grid. High humidity conditions (>60%) might generate con-
densation, especially at minimum ventilation speeds.
As soon as the level of relative humidity drops, the phe-
nomena disappears. However, a few water drops falling
inside the device will not cause any malfunction.
The device is loosing water in cooling mode.
The condensate tray is clogged. Slowly pour a bottle of water in the lower section of the
battery to check the drainage; if necessary clean the tray
and/or improve the slope of the drain pipe.
The condensate discharge pipe does not have the slope
required for correct drainage.
The connection pipes and the valves unit are not well
insulated. Check the pipe insulation.
The device generates excessive noise.
The fan touches the structure. Verify
The fan is unbalanced. The unbalancing generates excessive machine vibra-
tions: replace the fan.
Check the lters for dirt and clean them if necessary Clean lters
TECHNICAL INFORMATION
6�1 Technical data
KFC-F
Models m.u. 400 600 800
Cooling performances (W 7/12 °C; A 27 °C)
Total cooling capacity (1) kW 1,21 1,62 2,12
Sensible cooling capacity (1) kW 1,01 1,44 1,99
Water ow (1) L/h 208 279 365
Pressure drop (1) kPa 11,2 5,1 5,3
Heating performances (W 45/40 °C; A 20 °C)
Heating capacity (2) kW 1,51 2,03 2,62
Water ow (2) L/h 260 349 451
Pressure drop (2) kPa 16,1 7,3 8,1
Hydraulic data
Coil water content L 0,50 0,61 0,77
Maximum operating pressure bar 10 10 10
Hydraulic connections “ EK 3/4 3/4 3/4
Aeraulic data
Air ow at the maximum fan
speed m³/h 228 331 440
Air ow at the medium fan speed m³/h 155 229 283
Air ow at the minimum fan
speed m³/h 84 124 138
Static pressure available Pa 1 10 10
Electrical data
Power supply V/ph/Hz 230/1/50 230/1/50 230/1/50
Power consumption at the
maximum speed W 19 20 29
Maximum absorbed current A0,16 0,18 0,26
Power consumption at the
minimum speed W 4 4 4
Sound data
Maximum sound power level dB(A) 53 54 55
Sound pressure level at maxi-
mum air ow (3) dB(A) 40 41 42
Sound pressure level at medium
air ow (3) dB(A) 33 34 34
Sound pressure level at mini-
mum air ow (3) dB(A) 25 25 26
1. Water temperature in 7 °C, Water temperature out 12 °C, Room temperature 27 °C b.s. e 19 °C b.u. Performances according to EN 1397
2. Water temperature in 45 °C, Water temperature out 40 °C, Room temperature 20 °C b.s. e 15 °C b.u. Performances according to EN 1397
3. Sound pressure measured at a distance of 1 meter according to ISO 7779
3130
TECHNICAL INFORMATION NOTE
6�2 Overall dimensions
Dimensions
KFC-F
Models m.u. 400 600 800
Product dimensions and weight
Total length mm 895 1095 1295
Total widh mm 431 431 431
Total depth mm 189 189 189
Net weigth kg 14,0 16,0 19,0
A Top view
B Lateral view
189L
431
A B
Giacomini S.p.A.
Via per Alzo 39, 28017 San Maurizio d’Opaglio (NO) Italy
+39 0322 923372 - giacomini.com
Safety Warning. Installation, commissioning and periodical maintenance of the product
must be carried out by qualied operators in compliance with national regulations and/or local
standards. A qualied installer must take all required measures, including use of Individual
Protection Devices, for his and others’ safety. An improper installation may damage people,
animals or objects towards which Giacomini S.p.A. may not be held liable.
Additional information. For more information, go to giacomini.com or contact our technical
assistance service. This document provides only general indications. Giacomini S.p.A. may
change at any time, without notice and for technical or commercial reasons, the items included
herewith. The information included in this technical sheet do not exempt the user from strictly
complying with the rules and good practice standards in force.
IMPORTANT INFORMATION FOR CORRECT DISPOSAL OF THE PRODUCT
This product falls into the scope of the Directive 2012/19/EU concerning the management of Waste Electrical and Electronic Equipment (WEEE).
This product shall not be dispose in to the domestic waste as it is made of different materials that have to be recycled at the appropriate facilities.
Inquire through the municipal authority regarding the location of the ecological platforms to receive the product for disposal and its subsequent correct recycling.
Furthermore, upon purchase of an equivalent appliance, the distributor is obliged to collect the product for disposal free of charge.
The product is not potentially dangerous for human health and the environment, but if abandoned in the environment can have negative impact on the environment.
Read carefully the instructions before using the product for the rst time.
It is recommended that you do not use the product for any purpose rather than those for which it was intended, there being a danger of electric shock if used improperly.
The crossed-out wheeled dustbin symbol, on the label on the product, indicates the compliance of this product with the regulations regarding Waste Electrical and Electronic Equipment.
Abandonment in the environment or illegal disposal of the product is punishable by law.
Produced by Innova s.r.l.
Via I maggio 8, 38089 Storo (TN) ITALY
Distributed by Giacomini S.p.A. under the trademark
Via per Alzo 39, 28017 San Maurizio d’Opaglio (NO) Italia
consulenza.prodotti@giacomini.com +39 0322 923372 giacomini.com
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17

Giacomini KFC-F User manual

Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI