PERFORMANCE DATA
Important Notice: Read this performance data and compare
the capabilities of these systems with your actual water
treatment needs. It is recommended that, before installing a
water treatment system, you have your water supply tested to
determine your actual water treatment needs.
This system has been tested according to NSF/ANSI 42 and
53 for the reduction of the substances listed below. The
concentration of the indicated substances in water entering
the system was reduced to a concentration less than or
equal to the permissible limit for water leaving the system as
specified in NSF/ANSI 42 and 53.
Do not use with water that is microbiologically
unsafe or of unknown quality without adequate
disinfection before or after the system.
QC10CBR WITH QC10CBRR CARTRIDGE
Substance Influent Challenge
Concentration
Max. Permissible Product
Water Concentration
Reduction
Requirements
Minimum
Reduction
Average
Reduction
Standard 42—Aesthetic Effects
Chlorine 2.0 mg/L ± 10% ≥ 50% 97.5%
Particulate,
Class I
Particles*
0.5 - 1 µm
at least
10,000
particles/mL
≥ 85% 99.7%
Standard 53—Health Effects
Cyst** Minimum 50,000/L 99.95% 99.99%
Turbidity 11 mg/L ± 1 NTU 0.5 NTU 99.1%
Lead (pH
6.5) 0.15 mg/L ± 10% 0.010 mg/L 99.3%
Lead (pH
8.5) 0.15 mg/L ± 10% 0.010 mg/L 97.9%
Atrazine 0.009 mg/L ± 10% 0.003 mg/L 92.0%
Lindane 0.002 mg/L ± 10% 0.0002 mg/L 99.1%
Flow Rate = 0.5 gpm (1.9 L/min)
Capacity = 500 gallons (1,890 L) or 6 months
* Reduces particles as small as 0.5-1 micron in size by mechanical means.
**NSF/ANSI Standard 53 certified to reduce cysts such as Cryptosporidium and Giardia by
mechanical means.
QC10GAC WITH QC10GACR CARTRIDGE
Substance Influent Challenge
Concentration
Max. Permissible Product
Water Concentration
Reduction
Requirements
Minimum
Reduction
Average
Reduction
Standard 42—Aesthetic Effects
Chlorine 2.0 mg/L ± 10% ≥ 50% 84.2%
Flow Rate = 0.75 gpm (2.8 L/min)
Capacity = 2,500 gallons (9,460 L) or 9 months
QC10EP WITH QC10EPR CARTRIDGE
Substance Influent Challenge
Concentration
Max. Permissible Product
Water Concentration
Reduction
Requirements
Minimum
Reduction
Average
Reduction
Standard 42—Aesthetic Effects
Chlorine 2.0 mg/L ± 10% ≥ 50% 93.5%
Flow Rate = 0.5 gpm (1.9L/min)
Capacity = 1,500 gallons (5,670 L) or 9 months
Testing was performed under standard laboratory conditions; actual performance may vary.
QC10TSGAC WITH QC10TSGACR
CARTRIDGE
Substance Influent Challenge
Concentration
Max. Permissible Product
Water Concentration
Reduction
Requirements
Minimum
Reduction
Average
Reduction
Standard 42—Aesthetic Effects
Chlorine 2.0 mg/L ± 10% ≥ 50% 89.5% 96.5%
Flow Rate = 0.75 gpm (2.8 L/min)
Capacity = 1,700 gallons (6,435 L) or 9 months
Testing was performed under standard laboratory conditions; actual performance may vary.
Test Conditions:
Flow Rate = 0.5 gpm (QC10-CBR & QC10-EP)
= 0.75 gpm (QC-GAC, QC10-TSGAC)
Inlet Pressure = 60 psi (4.1 bar)
pH = 7.5 ± 1
Temperature = 68˚F ± 5˚F (20˚C ± 2.5˚C)
Operating Requirements:
Pressure = 30-125 psi (2.1-8.62 bar)
Temperature = 40˚-100˚F (4.4˚-37.8˚C)
Turbidity = 5 NTU Max
California Residents - Proposition 65
This product contains chemicals known to the
State of California to cause cancer or birth
defects or other reproductive harm.
EPA Est. #090375-MEX-001 PENTEK® QC10 SERIES Installation and Operation Manual • 5