Miele 37191301USA Merging Kits

Type
Merging Kits

This manual is also suitable for

MasterCool Refrigeration
Side-by-Side Merging Combinations
For Vi Models
8mieleusa.com
Page 2 of 7
Side-by-Side Merging Kit
KSK 1002
This merging kit should be used for
side-by-side installation of the following
models:
K 18x1 Vi, K 19x1 Vi,
K 18x3 Vi, K 19x3 Vi
F 14x1 Vi, F 18x1 Vi,F19x1Vi
F 14x3 Vi, F 18x3 Vi,F19x3Vi
KF 18x1 Vi, KF 19x1 Vi,
KF 18x3 Vi, KF 19x3 Vi
KWT 16x1 Vi, KWT 16x3Vi
en
3
Side-by-side
...without partition
If the appliances are installed directly
next to each other (without a partition),
they need to be attached together. A
heating mat must also be installed. This
will help avoid condensation and
prevent damages.
...withpartition
The minimumthicknessofthe partition
is
5
/
8
"(16 mm).
If thereisapartition withathickness
from
5
/
8
"(16 mm)to6
5
/
16
" (160 mm)
betweenthe adjacentappliances, then
each appliance should be individually
installed within itsown niche using the
mountingaccessories included.
In this case,you will only need the
heating matfrom the "Merging Kit" to
avoid condensationand prevent
damages.
en
4
Product and Cut-out Dimensions
48” Side-by-Side Combination
F14X3 & K18X3
Page 3 of 7
FOR FLUSH INSTALLATION
48"
25" min.*
84"
Notes
5 foot - 120 Volt - 15 Amp 3-wire molded plug power
supply connects lower left rear
One (1)Standard NEMA 5-15 Duplex Outlet - locate
less than 9" above finished floor
E -
O -
KSK1002 Merging kit must be used when
combining units
All Installations must be done in accordance
with local codes
For Proud Installation — please adjust accordingly
*Depth assumes a 3/4" panel, please adjust according
to custom panel thickness
Sides of adjoining cabinets should be filled
(flush to frame) to insure proper fit and finish
Location Codes
O
29 3/4"
"8/3 8 - "2
17 3/4"
83 1/2" - 85 3/8"
10 1/4"
24 5/8"
4 1/8"
1 1/8"
E
"2/1 8 - "8/5 6
UNITS ACCEPT CUSTOM
FRONT PANELS
See individual spec files for details
Product and Cut-out Dimensions
54” Side-by-Side Combination
F14X3 & K19X3
Page 4 of 7
FOR FLUSH INSTALLATION
54"
25" min.*
84"
O
35 3/4"
"8/3 8 - "2
17 3/4"
83 1/2" - 85 3/8"
10 1/4"
24 5/8"
4 1/8"
1 1/8"
E
"2/1 8 - "8/5 6
UNITS ACCEPT CUSTOM
FRONT PANELS
See individual spec files for details
Notes
5 foot - 120 Volt - 15 Amp 3-wire molded plug power
supply connects lower left rear
One (1)Standard NEMA 5-15 Duplex Outlet - locate
less than 9" above finished floor
E -
O -
KSK1002 Merging kit must be used when
combining units
All Installations must be done in accordance
with local codes
For Proud Installation — please adjust accordingly
*Depth assumes a 3/4" panel, please adjust according
to custom panel thickness
Sides of adjoining cabinets should be filled
(flush to frame) to insure proper fit and finish
Location Codes
Product and Cut-out Dimensions
60” Side-by-Side Combination
F18X3 & K18X3
Page 5 of 7
FOR FLUSH INSTALLATION
60"
25" min.*
84"
29 3/4"
"8/3 5 - "2/1 3
29 3/4"
83 1/2" - 85 3/8"
10 1/4"
24 5/8"
1 1/8"
Notes
5 foot - 120 Volt - 15 Amp 3-wire molded plug power
supply connects lower left rear
One (1)Standard NEMA 5-15 Duplex Outlet - locate
less than 9" above finished floor
E -
O -
KSK1002 Merging kit must be used when
combining units
All Installations must be done in accordance
with local codes
For Proud Installation — please adjust accordingly
*Depth assumes a 3/4" panel, please adjust according
to custom panel thickness
Sides of adjoining cabinets should be filled
(flush to frame) to insure proper fit and finish
Location Codes
E
O
UNITS ACCEPT CUSTOM
FRONT PANELS
See individual spec files for details
(Panel/handle shown is not included.)
Product and Cut-out Dimensions
66” Side-by-Side Combination
F18X3 & K19X3
Page 6 of 7
FOR FLUSH INSTALLATION
66"
25" min.*
84"
35 3/4"
"8/3 5 - "2/1 3
29 3/4"
83 1/2" - 85 3/8"
10 1/4"
24 5/8"
1 1/8"
Notes
5 foot - 120 Volt - 15 Amp 3-wire molded plug power
supply connects lower left rear
One (1)Standard NEMA 5-15 Duplex Outlet - locate
less than 9" above finished floor
E -
O -
KSK1002 Merging kit must be used when
combining units
All Installations must be done in accordance
with local codes
For Proud Installation — please adjust accordingly
*Depth assumes a 3/4" panel, please adjust according
to custom panel thickness
Sides of adjoining cabinets should be filled
(flush to frame) to insure proper fit and finish
Location Codes
E
O
UNITS ACCEPT CUSTOM
FRONT PANELS
See individual spec files for details
(Panel/handle shown is not included.)
Product and Cut-out Dimensions
72” Side-by-Side Combination
F19X3 & K19X3
Page 7 of 7
FOR FLUSH INSTALLATION
72"
25" min.*
84"
35 3/4"
"8/3 5 - "2/1 3
35 3/4"
83 1/2" - 85 3/8"
10 1/4"
24 5/8"
1 1/8"
Notes
5 foot - 120 Volt - 15 Amp 3-wire molded plug power
supply connects lower left rear
One (1)Standard NEMA 5-15 Duplex Outlet - locate
less than 9" above finished floor
E -
O -
KSK1002 Merging kit must be used when
combining units
All Installations must be done in accordance
with local codes
For Proud Installation — please adjust accordingly
*Depth assumes a 3/4" panel, please adjust according
to custom panel thickness
Sides of adjoining cabinets should be filled
(flush to frame) to insure proper fit and finish
Location Codes
E
O
UNITS ACCEPT CUSTOM
FRONT PANELS
See individual spec files for details
(Panel/handle shown is not included.)
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7

Miele 37191301USA Merging Kits

Type
Merging Kits
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI

in other languages