FTLX0071D4BNL Laserwire SFP+ Adapter Product Specification –July 2010
© Finisar Corporation - July 2010 Rev. B1 Page 8
Byte
Addr Hex LSB
Bit
Size Name Description Value
Hex
Value
10 0A 0 1 100 Mbytes/sec Fibre Channel speed FALSE 0
10 0A 1 1 RESERVED RESERVED
10 0A 2 1 200 Mbytes/sec Fibre Channel speed FALSE 0
10 0A 3 1 RESERVED RESERVED
10 0A 4 1 400 Mbytes/sec Fibre Channel speed FALSE 0
10 0A 5 1 RESERVED RESERVED
10 0A 6 1 800 Mbytes/sec Fibre Channel speed FALSE 0
10 0A 7 1 1200 Mbytes/sec Fibre Channel speed TRUE 1
11 0B 0 8 Encoding Code for serial encoding algorithm 64B/66B 6
12 0C 0 8 BR, Nominal Nominal bit rate, units of 100 Mbits/sec 103 67
13 0D 0 8 Rate Identifie
Rate selection functionalit
Unspecified 0
14 0E 0 8 Length (9μm) - km Link length 9μm fiber, units of km 0 0
15 0F 0 8 Length (9μm) Link length 9μm fiber, units of 100m 0 0
16 10 0 8 Length (50μm, OM2) Link length 50μm/OM2 fiber, units of 10m 8 8
17 11 0 8 Length (62.5μm, OM1)
Link length 62.5μm/OM1 fiber, units of
10m 3 3
18 12 0 8 Length (Copper) Link length copper, units of meters 0 0
19 13 0 8 Length (50μm, OM3) Link length 50μm/OM3 fiber, units of 10m 3 3
…
64 40 0 1 Options_Rx output Limiting = False, Linear = True FALSE 0
64 40 1 1 Options_Power class Class 1 = False, Class 2 = True FALSE 0
…
65 41 1 1 Options-Rx_LOS Rx_LOS implemented, per SFP MSA TRUE 1
65 41 2 1 Options-Rx_LOS Rx_LOS implemented, signal inverted FALSE 0
65 41 3 1 Options-Tx_FAULT Tx_FAULT signal implemented FALSE 0
65 41 4 1 Options-Tx_DISABLE Tx_DISABLE implemented FALSE 0
65 41 5 1 Options-RATE_SELECT
RATE_SELECT implemented, per SFP
MSA FALSE 0
65 41 6 2 RESERVED RESERVED
66 42 0 8 BR, max Upper bit rate margin, units of % 0 0
67 43 0 8 BR, min Lower bit rate margin, units of % 0 0
…
92 5C 2 1 Diagnostic Monitoring Type
Address change required see section
above, "addressing modes" FALSE 0
92 5C 3 1 Diagnostic Monitoring Type
Received power measurement type; 0 =
OMA, 1 = Average Power FALSE 0
92 5C 4 1 Diagnostic Monitoring Type Externally calibrated FALSE 0
92 5C 5 1 Diagnostic Monitoring Type Internally calibrated TRUE 1
92 5C 6 1 Diagnostic Monitoring Type
Digital diagnostic monitoring implemented
(described in this document). Must be '1'
for compliance with this document 1 1
92 5C 7 1 Diagnostic Monitoring Type
implementations. Must be '0' for
compilance with this document. 0 0
93 5D 0 1 RESERVED RESERVED
93 5D 1 1 Enhanced Options Rate Select control implemented FALSE 0
93 5D 2 1 Enhanced Options Application Select control implemented FALSE 0
93 5D 3 1 Enhanced Options
Optional Soft RATE_SELECT control and
monitoring implemented FALSE 0
93 5D 4 1 Enhanced Options
Optional Soft RX_LOS monitoring
implemented FALSE 0
93 5D 5 1 Enhanced Options
Optional Soft TX_FAULT monitoring
implemented FALSE 0
93 5D 6 1 Enhanced Options
Optional Soft TX_DISABLE control and
monitoring implemented FALSE 0
93 5D 7 1 Enhanced Options
Optional Alarm/Warning flags
implemented for all monitored quantities FALSE 0
94 5E 0 8 SFF-8472 Compliance
Indicates which revision of SFF-8472 the
transceiver complies with Not Included 0
…