De'Longhi Air Conditioner User manual

Category
Mobile air conditioners
Type
User manual
4
Important safeguard
• Use this appliance only as described in this
instructionmanual.
Aswithanyelectricalappliance,theinstructions
aim to cover as many situations as possible.
Cautionandcommonsenseshouldbeusedwhen
operatingandinstallingthisairconditioner.
• Thisappliancehas been manufacturedtocool
and dehumidify domestic environments and
mustnotbeusedforotherpurposes.
• It is dangerous to alter or modify the unit's
characteristicsinanyway.
• Theappliancemustbe installed in accordance
withtherelevantnationallegislation.
• Shouldrepairsbenecessary,contactthenearest
authorizedRepairServiceCenter.Unauthorized
servicingcanbedangerous.
• Theapplianceisnotintendedforusebypersons
(including children) with reduced physical,
sensory or mental capabilities, or lack of
experience and knowledge, unless they have
beengivensupervisionorinstructionconcerning
useoftheappliancebyapersonresponsiblefor
theirsafety.
Children should be supervised to ensure that
theydonotplaywiththeappliance.
• If the power cable is damaged, it must be
replacedbythemanufactureroranauthorized
technicalservicecentreinordertoavoidallrisk.
• Alwaysensuretheapplianceispluggedintoa
grounded3-prongoutlet.Ifyouhaveanydoubts
checkwithaqualiedelectrician.
• Donotuseextensioncables.
• Before cleaning or maintenance operations,
alwaysunplugtheunitfromtheoutlet.
• Donotpullonorplacestrainonthepowercord
whenmovingtheappliance.
• Theapplianceshouldnotbeinstalledwherethe
atmospheremaycontaincombustiblegases,oil
orsulphur,ornearheatsources.
• Donotresthotorheavyobjectsontheappliance.
• Cleantheltersatleastonceaweek.
• Avoidusingheatersneartheunit.
• The unit should be transported in a vertical
position.Ifthisisnotpossiblesecuretheunitat
anangle,donotlieithorizontally.
• Before transporting the unit, drain the unit.
Aftertransportation,waitatleast6hoursbefore
switchingtheuniton.
• The packaging materials can be recycled.You
are therefore recommended to place them in
the special containers for dierentiated waste
collection.
• This appliance is tted with a special safety
device.Whenthecompressorswitcheso,this
devicepreventsitfromswitchingonagainforat
least3minutes.
• WARNING: Changes or modications not
expresslyapprovedbythepartyresponsiblefor
compliance could void the user's authority to
operatetheequipment.
Specic warnings for appliances with R410A
refrigerant gas
R410ArefrigerantgasconformstoECregulationson
theenvironment.
Avoid perforating the refrigerant circuit of the
appliance.
ENVIRONMENTAL INFORMATION:
This unit contains uorinated greenhouse gases
coveredbytheKyotoProtocol.
Maintenance and disposal must be carried out by
qualiedpersonnelonly(R410A,GWP=1975).
Save these instructions
Thisproductisforhouseholdonly
5
INTRODUCTION
ThankyouforchoosingaDe’Longhiproduct.Pleasetakeafew
momentstoreadtheinstructionstoavoidrisksordamagetothe
appliance.
DESCRIPTION
Description of the appliance (see page 3 - A)
A1 airoutletgrille
A2 controlpanel
A3 handles
A4 castorwheels
A5 BioSilverlter
A6 airintakegrille
A7 airexhausthosehousing
A8 airintakegrille
A9 powercable
A10drainagehosewith2caps
A11remotecontrolsignalreceiver
A12remotecontrolcompartment
Descrizione of the accessories (see page 3 - B)
B1 wallangewithcap
B2 airexhausthose
B3 hoseadaptor
B4 accessoryforwallmounting
B5 windowbracketwithpins
B6 additionalwindowbracket
B7 windowoutlet
B8 remotecontrol
B9 endofseasondustcover
B10endofseasonaccessoriesbag
Electrical connection
Beforepluggingtheapplianceintotheoutlet,checkthat:
• Theoutlets powersupplycorrespondsto thevalue indi-
catedontheratinglabelonthebackoftheappliance;
• Theoutletandelectricalcircuitareadequatefortheappli-
ance;
• Theoutletisa3-holegroundedoutlet .Ifthisisnot
thecase,youmustchooseanotheroutlet.Failuretofollow
theseimportantsafetyinstructionsabsolvesthemanufac-
turerofallliability.
If it becomes necessary, the power cable must be re-
placed by a qualied professional only.
Theinstructionsbelowwillenableyoutoprepareyouraircon-
ditionerforoperationasecientlyaspossible.Beforeuse,make
suretheairintakeandoutletgrillesareunobstructed.
USE
AIR CONDITIONING WITHOUT INSTALLATION
For optimal results set-up in a double-hung window:
1) Placethebracket inthe window sill,extendthe bracket
fullywithinthewindowframe,xthebracketbyusingthe
pinthenlowerthewindowontothebracket.(Shouldthe
windowbracketbetoolargeforthewindow.Theplastic
canbecutwithasawbyaqualiedprofessional.)
2) ScrewthehoseadaptorB3tothehosesendB2.
3) Fittheairexhausthoseinthehousingatthebackofthe
appliance.Insertitasshowningure1.
4) ConnectthewindowoutletB7totheotherendoftheex-
hausthose.
5) Insertthewindowoutletendoftheexhausthoseintothe
slotofthewindowbracket(g.2).
Other set-up methods:
• Thankstothelockingpins,it’spossibletousethewindow
bracketalsoforslidingwindows.Positiontheholeofthe
bracketsotoallowacorrectinstallationoftheexhausthose
(seegure3).
1
2
6
• Ifyouhaveacasementwindow(gure4)followsteps2&
3andplacethewindowoutletB7outsidethewindowto
exhaustthehotair.
Forhelpwithinstallation,operation,andforall
accessoriesandspare/replacementparts,pleasecontact
ourtollfreecustomerservicecallcenterat:
1-800-322-3848[USonly]
1-888-335-6644[Canadaonly]
01-800-711-8805(Mexicoonly]
orlogontoourwebsiteat www.delonghi.com
SEMIPERMANENT INSTALLATION
If required, your appliance can also be installedsemi-perma-
nently(Fig.5).
min. 11,8 in
min. 30cm
min. 11,8 in
min. 30cm
Proceedasfollows:
• Drillaholeø5,25inches(134mm)inanoutsidewallor
through a window pane. Respect the dimensions and
heightoftheholegiveningure6and7.
134
Ø 5,25 in.
As special tools are required for installation, we suggest
you have the appliance installed by specialized person-
nel.
• FitthewallangeB1intothehole.
• FittheairexhausthoseB2 intherelevanthousinglocated
ontherearsideoftheappliance.(g.1).
• FittheendofthehoseB2 tothewallangeB1 asshownin
g.7.
3
4
5
6
inthe
window
panel
inthewooden
kickboard
ofaFrench
window
inthewall:
youare
recommended
toinsulatethe
sectionofwall
usingsuitable
insulation.
7
MAX 39 in
MIN 14 in
Whenthehose B2isnot connected,thedrilled holecan be
closedwiththeangecapB1.
NOTE: When installingthe air conditionersemi-permanently,
youshouldleaveadoorslightlyopenlittleas1/2“(1cm)to
guaranteecorrectventilationandroompressure.
NOTE:Keeptheairhosesasshortandfreeofcurvesaspossible
toavoidconstrictions.
7
CONTROL PANEL
C1 C10
C2 C11 C12 C14C13 C15 C3 C4
C8C9 C6C20C16C7 C5C17
C18
C19
DESCRIPTION OF THE CONTROL PANEL (C)
C1 ON/STAND-BYbutton
C2 MODE selectionbutton(conditioning,dehumidifying,fan,
heating)
C3 Timerbutton
C4 Increasetemperature/programmedoperationtimebutton
C5 Decreasetemperature/programmedoperationtimebutton
C6 Fanspeedselectionbutton(LOW/MED/HIGH/AUTO)
C7 WHISPERCOOLselectionbutton
C8 REALFEELselectionbutton
C9 REALFEELlight
C10 Air-conditioningsymbol
C11 Dehumidifyingsymbol
C12 Fansymbol
C13 Heatingsymbol
C14 Timersymbol
C15 Alarmsymbol
C16REALFEELsymbol
C17WHISPERCOOLsymbol
C18 Temperaturevalueset,programmeddelayedON/OFFtime
C19 Fanspeedindicator
C20 Timerindicator
C21 Temperatureselectedscaleindicator
Note: The panel buttons are backlit but only the buttons
relevanttotheactivefunctionwillbeon.
Afterfewsecondsofthecontrolpanelinactivity,itsbrightness
willbeautomaticallyreducedandinthenextfewminutesitwill
befurtherreduced.
C21
C
8
OPERATING FROM THE CONTROL PANEL
TURNING THE APPLIANCE ON/OFF
Before plugging the appliance check the cap on back of
the unit are correctly inserted on drainage hose A10
Plugtheapplianceintothemains.Twolinesappearonthedis-
playindicatingthattheapplianceisinstand-byandthebuttons
and lighton.
Touch button(C1)toswitchtheapplianceon.
Whenturnedon,theairconditionerstartsoperatinginthesame
modeaswhenitwasturnedo.
Note
:Ifyoudon’tswitchontheappliance,afterafewminutes,the
and buttonsswitchoandthedisplayfadestoreduceen-
ergyconsuption.
Toturnotheappliance,touchthe button,thenunplug
theappliance.
Note
:
Neverswitchotheappliancebyunpluggingit:always
the button,waitafewminutesandthenunplug.Doing
so,theappliancewillrunacheckoftheoperatingconditions.
FUNCTION
REALFEELis theinnovativeDe’Longhitechnologythatworks
simultaneouslyontemperaturereductionandhumiditycontrol,
securingbestcomfortlevel.
Withtraditionalsystems,duringworkingtime,optimalcomfort
conditionsmaybereachedbutnotsecuredovertime.WithREAL
FEEL,onceoptimalcomfortisreached,PACautomaticallymodu-
latescompressoractionandfanspeed,tokeepitovertime.
Toactivatethefunction,touch button.
Perfect!Perfect!
REALFEELlight(C9)changescolorwhenapproachingthebest
comfortlevel(seefollowingdiagram).
HIGH
°C/°F
%
LOW
LOW HIGH
Perfect!
Perfect!
• The well-being feeling is a subjective condition: for this
reason, dierent people may judge dierentlythesame
environmentalconditions.
• Inparticularlysevereenvironmentalconditions(largesize
oftheenvironment,hightemperatureorhumidityoutside,
poorinsulationoftheroom,toomanyofpeopleorstrong
heatloadintheroom,strongexposuretothesun...)this
devicemaynotbeabletoreachthebestcomfortlevel.
AIR CONDITIONING MODE
Idealforhotmuggyweatherwhenyouneedtocoolanddehu-
midifytheroom.Tosetthismode:
• TouchrepeatedlytheMODE buttonuntiltheconditioning
suymbol is displayed: the display shows the desired
temperature.
• Press+(C4)or-(C5)buttonstoadjustthedesiredtem-
perature.
• Selectthefanspeedbypressingthe button(C6).
ORANGE LIGHT: Room conditions far
fromoptimallevel.
GREEN LIGHT: Most people feel good
roomconditions,nearoptimallevel.
BLUE LIGHT: Bestcomfortlevel.
HUMIDITY
TEMPERATURE
HIGH
MEDIUM
LOW
HIGH
MEDIUM
LOW
Operating curve
9
Perfect!Perfect!
REALFEELlight(C9)changescolorwhenapproachingthebest
comfortlevel(seefollowingdiagram).
HIGH
°C/°F
%
LOW
LOW HIGH
Perfect!
Perfect!
• The well-being feeling is a subjective condition: for this
reason, dierent people may judge dierentlythesame
environmentalconditions.
• Inparticularlysevereenvironmentalconditions(largesize
oftheenvironment,hightemperatureorhumidityoutside,
poorinsulationoftheroom,toomanyofpeopleorstrong
heatloadintheroom,strongexposuretothesun...)this
devicemaynotbeabletoreachthebestcomfortlevel.
AIR CONDITIONING MODE
Idealforhotmuggyweatherwhenyouneedtocoolanddehu-
midifytheroom.Tosetthismode:
• TouchrepeatedlytheMODE buttonuntiltheconditioning
suymbol is displayed: the display shows the desired
temperature.
• Press+(C4)or-(C5)buttonstoadjustthedesiredtem-
perature.
• Selectthefanspeedbypressingthe button(C6).
Youcanchoose:
Minimum speed:forsilentoperation.
Medium speed:reducesnoiselevelswhile main-
tainingacomfortabletemperature.
Maximum speed:toachievethetargettempera-
tureasrapidlyaspossible.
the appliance automatically selects the
mostsuitablefanspeedinrelationtothetemperaturesetonthe
digitaldisplayandcurrentroomtemperature.
The most suitable temperature for the room during the summer
varies from 75°F to 81°F (24 to 27°C). You are recommended,
however, not to set a temperature much below the outdoor tem-
perature.
WHISPER COOL (available in conditioning mode only)
By activating this function, the operating noise is further re-
duced.Toactivateit,touchthe (C7)button.
Thedisplayshowstherelativesymbol(C16).
DEHUMIDIFYING MODE
Ideal to reduce room humidity (spring and autumn, damp
rooms,rainyperiods,etc).In dehumidifyingmode,theappli-
ance MUSTbeset-upinthesame wayasforairconditioning,
withtheairexhausthose(B2)attachedtoenablethemoisture
tobedischargedoutside.Tosetthismode:
• TouchrepeatedlytheMODE buttonuntilthedehumidify-
ingsymbolisdisplayed.
FAN MODE
Whenusingthe appliancein thismode,theair exhausthose
(B2)doesnotneedtobeconnected.
Tosetthismode:
• TouchrepeatedlytheMODE buttonuntilthefansymbolis
displayed.
• Selectthefanspeedbypressingthe button(C6).
Youcanchoose:
Minimum speed:forsilentoperation.
Medium speed:reducesnoiselevelsbutstillmain-
tainsagoodlevelofcomfort.
Maximum speed:formaximumfanpower.
HEATING MODE
Thisisidealinspringandautumnwhenoutdoortemperatures
arenotparticularlysevere.Forthismode,theapplianceshould
bepreparedinthesamewayasforairconditioning,withthe
airexhausthose(B2)attachedtoenablethemoisturetobedis-
chargedoutside.Tosetthismode:
• TouchrepeatedlytheMODE buttonuntiltheheatingsym-
bolisdisplayed.
• Press+(C4)or-(C5)buttonstoadjustthedesiredtem-
perature.
Note:
• Inthismode,fanspeedisselectedautomaticallybytheap-
plianceandcannotbesetmanually.
• Whenoperatinginverycoldrooms,theappliancedefreez-
esautomatically,momentarilyinterruptingnormalopera-
tion.“Lt“appearsonthedisplay.Duringthisoperation,it
isnormalforthenoisemadebytheappliancetochange.
• Inthismode,youmayhavetowaitafewminutesbefore
theappliancestartsgivingouthotair.
• Inthismode,thefanmayoperateforshortperiods,even
thoughthesettemperaturehasalreadybeenreached.
• Itmayhappen thatthedisplayshows“HLalarm.Inthis
case,emptytheinternalsafetytankfollowingtheinstruc-
tionintheSection“EndofSeasonoperatons”.Attheend,
pressagainthe buttontorestoretheheatingfunction.
CHANGING TEMPERATURE SCALE
x20”
Thetemperaturecanbedisplayedin°For°C.Tochangethetem-
peraturescale,turnotheunitbypushingthe button,then
keeppushedthe MODEbuttonfor approximately20seconds.
Theapplianceemitsabeeptoconrm.
10
SETTING THE TIMER
Thetimercanbeusedtodelayappliancestartuporshutdown.
Thisavoidswasting electricity bynot operatingthe appliance
whenitisnotneeded.
How to program delayed start up
• Plug the appliance into the mains and turn the unit to
standby.
• Touchthetimerbutton(C3):thetimersymbol(C13)and
thenumberofhourscomeon.
• Usethe+(C4)or- (C5)buttonstosetthenumberofhours
delaybeforetheappliancecomeson.
• Theapplianceworksusingthemodepreviouslyset.
Theappliancecanbesettocomeonwithinthenext24hours.
Afewsecondafterset,thesettingismemorised,thetimersym-
bolislitandthedisplayshowsthattheapplianceisinstandby.
Todeletthesetting,touchtwotimesthetimerbutton(C3).The
timersymbol(C13)switcheso.
How to program delayed shutdown
• Withtheairconditioninon,ineverymode,itispossibleto
setthedelayedshutdown.
• TouchtheTimer(C3)button:thetimersymbol(C13)and
thehoursswitchon.
• Usethe+(C4)or- (C5)buttonstosetthenumberofhours
delaybeforetheapplianceturnso.
Afewsecondafterset,thesettingismemorised,thetimersym-
bolislitandthedisplayshowsthecurrentmode.
Attheendofthesettimetheapplianceautomaticallyturnsin
standbymode.
Todeletthesetting,touchtwotimesthetimerbutton(C3).The
timersymbol(C13)switcheso.
USING THE REMOTE CONTROL
• Pointtheremotecontrolat thereceiver(A11)onthe air
conditioner.Theremotecontrolmustbenomorethan16
ft(5metres)awayfromtheappliance(withoutobstacles
betweentheremotecontrolandthereceiver).
• Theremotecontrolmustbehandledwithextremecare.Do
notdropitorexposeittodirectsunlightorsourcesofheat.

NOTE: Theremotecontrolcanbesafelystoredintheappropiate
compartmentA12(seegure).
DESCRIPTION OF THE REMOTE CONTROL D
D1) ON/STAND-BYbutton
D2) Increase/decreasetemperature/programmedoperation
D3) MODE”selectionbutton
D4) Fanspeedselectionbutton( )
D5) REAL FEEL selectionbutton
D6) WHISPER COOL selectionbutton
D7) Switchbutton°C/°F
D8) TIMER button

INSERTING OR REPLACING THE BATTERIES
• Removethecoverontherearoftheremotecontrol;
• ReplacetheoldbatterieswithtwonewR03AAA1.5Vbat-
teries,insertingthemcorrectly(seetheinstructionsinside
thebatterycompartment);
• Replacethecover.
If the remote control unit is replaced or discarded, the batteries
must be removed and disposed of in accordance with current
legislation as they are harmful to the environment. Do not mix
old and new batteries.
Do not mix alkaline, standard (carbon-zinc) or rechargeable
(nickel-cadmium) batteries. Do not dispose of batteries in re.
Batteries may explode or leak. If the remote control is not be
used for a certain length of time, remove the batteries.
Note:
• Thisequipmenthasbeentestedandfoundtocomplywith
thelimitsforaClassBdigitaldevice,pursuanttopart15of
theFCCRules.Theselimitsaredesignedtoprovidereason-
ableprotectionagainstharmfulinterferenceinaresiden-
tialinstallation.
• Thisequipmentgenerates,usesandcanradiateradiofre-
quencyenergyand,ifnotinstalledandusedinaccordance
withtheinstructions, maycause harmfulinterferenceto
radio communications. However, there is no guarantee
thatinterferencewillnotoccurinaparticularinstallation.
Ifthisequipmentdoescauseharmfulinterferencetoradio
ortelevisionreception,whichcanbedeterminedbyturn-
D1
D4
D2
D8
D6D5
D3
D7
MAX 16 ft
MAX 5 metres
11
ingtheequipmentoandon,theuserisencouragedtotry
tocorrecttheinterferencebyoneormoreofthefollowing
measures:
-Reorientorrelocatethereceivingantenna.
- Increase the separation between the equipment and
receiver.
- Connecttheequipmentintoanoutletonacircuitdier-
entfromthattowhichthereceiverisconnected.
- Consultthedealeroranexperiencedradio/TVtechnician
forhelp.
Changes or modications not expressly approved bythe
partyresponsibleforcompliancecouldvoidtheuser’sau-
thoritytooperatetheequipment.
• ThisdevicecomplieswithPart15oftheFCCRules.Opera-
tionissubjecttothefollowingtwoconditions:(1)thisde-
vicemaynotcauseharmfulinterference,and(2)thisdevice
mustacceptanyinterferencereceived,includinginterfer-
encethatmaycauseundesiredoperation.
• ThisClassBdigitalapparatuscomplieswithCanadianICES-
003.
TURNING THE APPLIANCE ON
• Plugintotheoutlet.
• Pressthe button(D1)(whenturnedon,theaircon-
ditionerstartsoperatinginthesamemodeaswhenitwas
turnedo).
• Toswitchtheapplianceo,pressbutton(D1) ,then
removetheplug.
NOTE: Never switchthe applianceo byremovingthe plug.
Alwaysswitchitobypushingonthe buttonand
waitingfewminutesbeforeremovingtheplug.Onlyinthis
waytheappliancewillperformthestandardcheckings.
MODE SELECTION
Thecontrolsontheremotecontrolarethesameasthoseonthe
controlpaneloftheappliance(C).Youshouldthereforereferto
the instructions in the chapterOPERATINGFROMTHE CON-
TROLPANELtoselectthedesiredfunctions.PressbuttonD7,
toswitchthetemperaturedisplayfrom°Cto°Fandviceversa.
SELFDIAGNOSIS
Theappliancehasaselfdiagnosissystemtoidentifyanumberofmalfunctions.
Errormessagesaredisplayedontheappliancedisplay.
IF ... IS DISPLAYED,
“LowTemperature”
(frostprevention)
..WHAT SHOULD I DO?
Theapplianceisttedwithafrostprotec-
tiondevicetoavoidexcessiveformationof
ice.The appliancestarts up againauto-
matically when the defrosting process is
completed.
IF ... IS DISPLAYED,
ProbeFailure
(Probedamaged)
..WHAT SHOULD I DO?
Ifthisisdisplayed,contactyourlocalau-
thorizedservicecenter.
IF ... IS DISPLAYED,
“HighLevel”
(Internaltrayfull)
..WHAT SHOULD I DO?
Empty theinternal safety tankfollowing
the instructions in the section “End of
season operations”. If HL alarm reoccurs
frequentely inAirConditioning,Dehumi-
difying or Real Feel mode, contact your
localauthorizedservicecenter.
12
TIPS FOR CORRECT USE
Toensureoptimalresultsfromyourairconditioner,followthese
recommendations:
• closethewindowsanddoorsintheroomtobeaircondi-
tioned When installingtheair conditioner semi-perma-
nently,youshouldleaveadoorslightlyopen(aslittleas
0.39inch.(1cm))toguaranteeproperventilation.
Closedoorsandwindows
• Neverusetheapplianceinverydamprooms(laundriesfor
example).
• Protecttheroomfromdirectexposuretothesunbypar-
tiallyclosingcurtainsand/orblindstomaketheappliance
muchmoreeconomicaltorun
Closeblindsorcurtains
• Neverusetheapplianceoutdoors.
•
Makesuretherearenoheatsourcesintheroom;
• makesuretheairconditionerisstandingonalevelsurface.
donotcovertheappliance
• Neverrestobjectsofanykindontheairconditioner;
• Neverobstructtheairintakeoroutletgrilles;
CLEANING
Before cleaning or maintenance, turn the appliance o by
touchingthe button,thenunplugfromtheoutlet.
CLEANING THE CABINET
Youshouldcleantheappliancewithaslightlydampcloththen
drywithadrycloth.Forsafetyreasons,neverwashtheaircon-
ditionerwithwater.
Precautions
Never use petrol, alcohol or solvents to clean the appliance.
Neversprayinsecticideliquidsorsimilar.
CLEANING THE BIO SILVER AIR FILTER
Ifthe lterisdirty,aircirculationis compromisedandthe ef-
ciency of the dehumidifying and air purifying functions de-
creases.
Itisthereforegoodpracticetocleanthelteratregularinter-
vals.Thefrequencydependsonthedurationandconditionsof
operation.
Iftheunitisusedconstantlyorsystematically,youarerecom-
mendedtocleanthelteronceaweek.
Thelterishousedintheintakegrille.
Tocleanthelter,extractasshowning.12.
Useavacuumcleanertoremovethedustcollectedonthelter.
Ifitisverydirty,immerseinwarmwaterandrinseanumberof
times.Thewatershouldneverbehotterthan104°F.
After washing the lter, allow it to dry completely before
repositioningit.
TheBioSilverlterhelpscapturedustandpollenandhelpsre-
ducethegrowthofbacteriaandmoldonthelter.
START OF SEASON CHECKS
Makesurethepowercable andplugareundamaged andthe
earthsystemisecient.
Followtheinstallationinstructionsprecisely.
12
13
END OF SEASON OPERATIONS
Todrainallwaterfromthecircuit,removetheexternalcapby
unscrewingit inthe anticlockwisedirection then,removethe
internalcapfromthedrainageonthebackoftheapplianceand
allowthewatertodrainoutintoabasin(g.13).
Inordertoproperlystoragetheapplianceattheendofthesea-
son,wesuggestyoucoveritwiththesuppliedendof season
dustcoverB9andyouputtheaccessoriesintherelevant
endofseasonaccessoriesbagB10.
Whentheapplianceisempty,replacethecaps.
Cleanthelteranddrythoroughlybeforeputtingback.
TECHNICAL SPECIFICATIONS
Powersupplyvoltage seeratinglabel
Max.absorbedpower
duringairconditioning 
Refrigerant 
Coolingcapacity 
LIMIT CONDITIONS
Roomtemperaturefor
airconditioning 64÷95°F(18°÷35°C)
Transport, lling, cleaning, recovery and disposal of
refrigerant should be performed by a technical service
centre appointed by the manufacturer only.
The appliance should be disposed of by a specialist centre
appointed by the manufacturer only.
TO AVOID DAMAGE TO THE UNIT:
NEVERTRANSPORTORTURNTHEAPPLIANCEUPSIDEDOWNOR
ONITSSIDE.IFTHISOCCURS,WAIT6 HOURSBEFORETURNING
THEAPPLIANCEON,24HOURSISRECOMMENDED.Aftertheunit
hasbeenonitsside,oilneedstoreturntothecompressortoen-
sureproperfunction.Withoutallowingtheunitthistime(6-24
hours)theunitmayfunctionforonlyashorttime,andthenthe
compressorwillbreakdownfromlackofoil.
ELECTRICAL CONNECTION
Thisapplianceisequippedwitha3pronggroundedplug.The
plugmustbeconnectedintoanoutletthatisproperlyinstalled
andgroundedintheaccordancewithalllocalcodesandordi-
nances.Donot modify the plug providedwith the appliance.
Ifit willnottthe outlet,havea properoutlet installed bya
qualiedelectricianorrelocatetheunittoaproperoutlet.Ifthe
householdelectricalsupplydoesnotmeettheabovespecica-
tions,orifyouarenotsureyourhomehasaneectiveelectrical
ground,haveaqualiedelectricianoryourlocalelectricalutility
companycheckitandcorrectanyproblems.
SAFETY PLUG
Theapplianceisttedwithasafetyplugtoprotectthepower
cable.
Ifpoweriscuto,unplug fromtheoutletandmakesurethe
powercableisundamaged.
Ifthecableisdamaged,calltheservicecenterimmediately.
Ifpowercutsofrequentlyandthepowercableisundamaged,
contactaqualiedelectrician.
OPERATION OF THE SAFETY PLUG
Ifthesafetydeviceincorporatedintheplugtripsand cutso
thepowersupply,checkthatthepowercableandplugarenot
damaged.
Ifthepowercableisundamaged,torestoreoperationpressthe
"RESET"button.
Toverifycorrectoperationoftheplug,pressthe"TEST"button
periodicallyandmakesuretheappliancedisconnects.Ifthisis
notthecase,contacttheservicecenter.
Torestoreoperation,pressthe"RESET"button.
13
14
TROUBLESHOOTING
PROBLEM CAUSE SOLUTION
Theairconditionerdoesnotcomeon itisnotpluggedintotheoutlet plugintotheoutlet
thereisnocurrent wait
theinternalsafetydevicehastripped calltheServiceCenter
Theairconditionerworksforashort
timeonly
therearebendsorkinksintheair
exhausthose
positiontheairhosecorrectly,keepingit
asshortandfreeofcurvesaspossibleto
avoidbottlenecks
somethingispreventingtheairfrom
beingdischarged
checkandremoveanyobstacles
obstructingairdischarge
Theairconditionerworks,butdoesnot
cooltheroom
windows,doorsand/orcurtainsopen closedoors,windowsandcurtains,
bearinginmindtheTIPSFORCORRECT
USEgivenabove
thereareheatsourcesintheroom(oven,
hairdryer,etc
eliminatetheheatsources
theairexhausthoseisdetachedfrom
theappliance
ttheairexhausthoseinthehousingat
thebackoftheappliance(g.1).
dustltersclogged cleanorreplacetheltersasdescribed
above
thetechnicalspecicationofthe
applianceisnotadequatefortheroom
inwhichitislocated.
Duringoperation,thereisanunpleasant
smellintheroom
dustlterandelectrostaticlterclogged cleantheltersasdescribedabove
Theairconditionerdoesnotoperatefor
aboutthreeminutesafterrestartingit
preventstheappliancefrombeing
restarteduntilthreeminuteshave
elapsedsinceitwaslastturnedo
wait.Thisdelayispartofnormal
operation.
Thesymbol andoneofthe
followingmessages:HL/PF
theappliancehasaselfdiagnosissystem
toidentifyanumberofmalfunctions.
seetheSELF-DIAGNOSISchapter
15
De’LonghiisthedistributorofKenwoodhomeappliances.
This warranty applies to all home appliances with De’Longhi or Kenwood brand names
LIMITED WARRANTY
WewarranteachDe’LonghiAIRCONDITIONERtobefreefromdefectsinmaterialandworkmanship.Fromthepurchasedate,our
obligationunderthiswarrantyistoprovidetwo(2)yearfreepartsandlaborontheentireAIRCONDITIONER,withanadditionalfour
(4)yearsfreeonanypartofthesealedsystemconsistingofthecompressor,evaporator,condenserandfactoryconnectedrefrigerant
tubing.Laborandallotherpartsduringtheadditionalfour(4)yearwarrantyaretobepaidbytheowner.AllAIRCONDITIONERSin
needofrepairaretobeshippedtoanauthorizedDe’Longhiservicecenterattheowner’sexpense,andDe’Longhiwillthenincurthe
returnshippingcosts.Aftertherstsix(6)yearsofownership,allexpenses(allparts,laborandshipping)aretobepaidbytheowner
oftheunit.ThiswarrantyshallapplyonlyiftheAIRCONDITIONERisusedinaccordancewiththefactorydirectionsthataccompanyit,
andonanAlternatingCurrent(AC)circuit.Thiswarrantyisinlieuofallotherwarrantiesandrepresentations,expressedorimplied,
andallotherobligationsorliabilitiesonourpart.Wedonotauthorizeanyotherpersonorcompanytoassumeforusanyliabilityin
connectionwiththesaleoruseofourAIRCONDITIONER.ThiswarrantyshallnotapplytoanyAIRCONDITIONERthathasbeenrepaired
oralteredoutsideourfactorynorshallitapplytoanyAIRCONDITIONERthathasbeensubjectedtomisuse,negligenceoraccidents.
Ifrepairsbecomenecessary,seecontactinformationbelow:
U.S. Residents:
Pleasecontactourtollfreehotlineat 1-800-322-3848
orlogontoourwebsiteatwww.delonghi.com
CANADA Residents:
Pleasecontactourtollfreehotlineat1-888-335-6644
orlogontoourwebsiteatwww.delonghi.com
MEXICO Residents:
Pleasecontactourtollfreehotlineat01-800-711-8805
orlogontoourwebsiteatwww.delonghi.com
Theabovewarrantyisinlieuofallotherexpresswarrantiesandrepresentations.Allimplied
warrantiesarelimitedtotheapplicablewarrantyperiodsetforthabove.Thislimitationdoesnotapplyifyouenterintoanextended
warrantywith De’Longhi.Somestates/countriesdo not allow limitations on how long an implied warranty lasts, so the above
exclusionsmaynotapplytoyou.De’Longhidoesnotauthorizeanyotherpersonorcompanytoassumeforitanyliabilityin
connectionwiththesaleoruseofitsappliance.
How does country law apply?
Thiswarrantygivesyouspeciclegalrights,andyoumayalsohaveotherrights,whichvaryfromstatetostate/countrytocountry.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12

De'Longhi Air Conditioner User manual

Category
Mobile air conditioners
Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI