Hitachi Compute Blade 500 Series Function Manual

Type
Function Manual
MK-91CB500033-03
Hitachi Compute Blade 500 series
LAN Advanced Function Manual (for Intel)
F
AST
F
IND
L
INKS
Getting Help
Contents
ii
Hitachi Compute Blade 500 Series LAN Advanced Function Manual (for Intel)
© 2012-2013 Hitachi, Ltd. All rights reserved.
No part of this publication may be reproduced or transmitted in any form or by any
means, electronic or mechanical, including photocopying and recording, or stored
in a database or retrieval system for any purpose without the express written
permission of Hitachi, Ltd.
Hitachi, Ltd., reserves the right to make changes to this document at any time
without notice and assumes no responsibility for its use. This document contains
the most current information available at the time of publication. When new or
revised information becomes available, this entire document will be updated and
distributed to all registered users.
Some of the features described in this document might not be currently available.
Refer to the most recent product announcement for information about feature and
product availability, or contact Hitachi Data Systems at https://portal.hds.com.
Notice: Hitachi, Ltd., products and services can be ordered only under the terms
and conditions of the applicable Hitachi Data Systems agreements. The use of
Hitachi, Ltd., products is governed by the terms of your agreements with Hitachi
Data Systems.
Hitachi is a registered trademark of Hitachi, Ltd., in the United States and other
countries. Hitachi Data Systems is a registered trademark and service mark of
Hitachi, Ltd., in the United States and other countries.
Archivas, Essential NAS Platform, HiCommand, Hi-Track, ShadowImage,
Tagmaserve, Tagmasoft, Tagmasolve, Tagmastore, TrueCopy, Universal Star
Network, and Universal Storage Platform are registered trademarks of Hitachi Data
Systems.
AIX, AS/400, DB2, Domino, DS8000, Enterprise Storage Server, ESCON, FICON,
FlashCopy, IBM, Lotus, OS/390, RS6000, S/390, System z9, System z10, Tivoli,
VM/ESA, z/OS, z9, zSeries, z/VM, z/VSE are registered trademarks and DS6000,
MVS, and z10 are trademarks of International Business Machines Corporation.
All other trademarks, service marks, and company names in this document or
website are properties of their respective owners.
Microsoft product screen shots are reprinted with permission from Microsoft
Corporation.
Contents iii
Hitachi Compute Blade 500 Series LAN Advanced Function Manual (for Intel)
Contents
Preface .................................................................................................... v
Intended Audience ............................................................................................... vi
Release Notes ...................................................................................................... vi
Document Conventions ......................................................................................... vi
Getting Help........................................................................................................ viii
Comments .......................................................................................................... viii
Updating LAN driver ............................................................................... 1-1
Procedure on Windows Server 2008 (32 bit)/(64 bit) or Windows Server 2008 R2 .. 1-2
Procedure on Windows Server 2012 .................................................................... 1-5
LAN Advanced Functions ........................................................................ 2-1
Teaming and Tag VLAN Setting (for Windows Server 2008) .................................. 2-9
Teaming and Tag VLAN Setting (for Windows Server 2008 R2) ........................... 2-41
iv Contents
Hitachi Compute Blade 500 Series LAN Advanced Function Manual (for Intel)
Preface v
Hitachi Compute Blade 500 Series LAN Advanced Function Manual (for Intel)
Preface
This document describes how to use the Compute Blade 500 series.
This preface includes the following information:
Intended Audience
Release Notes
Document Conventions
Getting Help
Comments
Notice: The use of Compute Blade 500 series and all other Hitachi Data
Systems products is governed by the terms of your agreement(s) with Hitachi
Data Systems.
vi Preface
Hitachi Compute Blade 500 Series LAN Advanced Function Manual (for Intel)
Intended Audience
This document is intended for the personnel who are involved in planning,
managing, and performing the tasks to prepare your site for Compute Blade
installation and to install the same.
This document assumes the following:
The reader has a background in hardware installation of computer systems.
The reader is familiar with the location where the Compute Blade will be
installed, including knowledge of physical characteristics, power systems and
specifications, and environmental specifications.
Release Notes
Release notes contain requirements and more recent product information that
may not be fully described in this manual. Be sure to review the release notes
before installation.
Document Conventions
This term Compute Blade refers to all the models of the Compute Blade, unless
otherwise noted.
The Hitachi Virtualization Manager (HVM) name has been changed to Hitachi
logical partitioning manager (LPAR manager, or LP). If you are using HVM based
logical partitioning feature, substitute references to Hitachi logical partitioning
manager (LPAR manager, or LP) with HVM.
This document uses the following typographic conventions:
Convention
Description
Bold
Indicates text on a window, other than the window title, including menus, menu
options, fields, and labels. Example: Click OK.
Italic
Indicates a variable, which is a placeholder for actual text provided by the user
or system. Example: copy source-file target-file
Note: Angled brackets (< >) are also used to indicate variables.
screen/code
Indicates text that is displayed on screen or entered by the user.
Example: # pairdisplay -g oradb
< > angled brackets
Indicates a variable, which is a placeholder for actual text provided by the user
or system. Example: # pairdisplay -g <group>
Note: Italic font is also used to indicate variables.
[ ] square brackets
Indicates optional values. Example: [ a | b ] indicates that you can choose a, b,
or nothing.
{ } braces
Indicates required or expected values. Example: { a | b } indicates that you
must choose either a or b.
Preface vii
Hitachi Compute Blade 500 Series LAN Advanced Function Manual (for Intel)
Convention
Description
| vertical bar
Indicates that you have a choice between two or more options or arguments.
Examples:
[ a | b ] indicates that you can choose a, b, or nothing.
{ a | b } indicates that you must choose either a or b.
underline
Indicates the default value. Example: [ a | b ]
This document uses the following icons to draw attention to information:
Meaning
Description
WARNING
This indicates the presence of a potential risk that might cause death
or severe injury.
CAUTION
This indicates the presence of a potential risk that might cause
relatively mild or moderate injury.
NOTICE
This indicates the presence of a potential risk that might cause severe
damage to the equipment and/or damage to surrounding properties.
Note
This indicates notes not directly related to injury or severe damage to
equipment.
Tip
This indicates advice on how to make the best use of the equipment.
viii Preface
Hitachi Compute Blade 500 Series LAN Advanced Function Manual (for Intel)
Getting Help
The Hitachi Data Systems customer support staff is available 24 hours a day,
seven days a week. If you need technical support log on to the Hitachi Data
Systems Portal for contact information: https://hdssupport.hds.com.
Comments
Please send us your comments on this document: doc.comments@hds.com.
Include the document title, number, and revision, and refer to specific sections
and paragraphs whenever possible. All comments become the property of
Hitachi Data Systems. Thank you!
Updating LAN driver 1-1
Hitachi Compute Blade 500 Series LAN Advanced Function Manual (for Intel)
1
Updating LAN driver
This chapter describes the procedure to update LAN driver, which is included in
the “Driver and Utility for Windows” DVD-ROM.
Procedure on Windows Server 2008 (32 bit)/(64 bit) or Windows Server
2008 R2
Procedure on Windows Server 2012
1-2 Updating LAN driver
Hitachi Compute Blade 500 Series LAN Advanced Function Manual (for Intel)
Procedure on Windows Server 2008 (32 bit)/(64 bit) or
Windows Server 2008 R2
1. Double-click [Device Manager] in [Control Panel].
2. On the [Device Manager] screen, right-click the LAN device and select [Update Driver
Software...] from the menu.
3. When the following screen is displayed, click [Browse my computer for driver
software] button.
Updating LAN driver 1-3
Hitachi Compute Blade 500 Series LAN Advanced Function Manual (for Intel)
4. When the following screen is displayed, insert the DVD "Driver and Utility for
Windows" into the DVD-ROM drive. Then, input the location of the LAN driver software
shown in the following tables in the combo box labeled "Search for driver software in
this location:" in "Update Driver Software" window and click [Next] button.
The location of the LAN driver software for each of Windows Server 2008 (32bit),
Windows Server 2008 (64bit), and Windows Server 2008 R2 is shown in the following
tables with the example when the DVD-ROM drive is drive (D:).
<Driver and Utility for Windows>
OS
Location of the LAN driver
Windows Server 2008 32-bit
D:\GC0x1\Win2008\Drivers\LAN\INTEL_01\x86 *
Windows Server 2008 64-bit
D:\GC0x1\Win2008\Drivers\LAN\INTEL_01\x64 *
Windows Server 2008 R2
D:\GC0x1\Win2008R2\Drivers\LAN\INTEL_01\x64 *
*: A part of the directory path "GC0x1" varies depending on server blade model
1-4 Updating LAN driver
Hitachi Compute Blade 500 Series LAN Advanced Function Manual (for Intel)
5. When the following screen is displayed, click the [Close] button.
6. When updating another adapters LAN driver, repeat step 2 through 5.
Updating LAN driver 1-5
Hitachi Compute Blade 500 Series LAN Advanced Function Manual (for Intel)
Procedure on Windows Server 2012
Install the LAN driver in the DVD-ROM "Driver Kit for Windows Server 2012" according to
the following procedure.
1. Log on the guest OS with an administrative account. At the time, the hardware
attached or assigned to the LPAR are detected by the guest OS.
2. Select [Tools]-[Computer Management] in Server Manager Window.
Computer Management window is displayed.
3. Select [Device Manager].
1-6 Updating LAN driver
Hitachi Compute Blade 500 Series LAN Advanced Function Manual (for Intel)
4. Double-click the "Intel(R) 82576 Gigabit Dual Port Network Connection" adapter to
update in "Network adapters".
The property window is displayed.
5. Select [Driver] tab and then click [Update Driver] button.
Update Driver Software window is displayed.
Updating LAN driver 1-7
Hitachi Compute Blade 500 Series LAN Advanced Function Manual (for Intel)
6. Select "Browse my computer for driver software".
7. Insert the DVD-ROM "Driver Kit for Windows Server 2012" and then input the location
of the LAN driver software shown in the following table in the combo box labeled
"Search for driver software in this location:" and click [Next] button.
The location of the LAN driver software for Windows Server 2012 is shown in the
following table with the example when the DVD-ROM drive is drive (D:).
OS
Location of the LAN driver
Windows Server 2012
D:\WinSrv2012\Drivers\NIC\IntelNIC_02\x64
1-8 Updating LAN driver
Hitachi Compute Blade 500 Series LAN Advanced Function Manual (for Intel)
8. The necessary driver for the "Intel(R) 82576 Gigabit Dual Port Network Connection"
adapter is installed automatically. When the following message "The best driver
software for your device is already installed" is displayed, click [Close] button.
When the best driver software is already installed, the following window is
displayed. In this case, click [Close] button.
9. Click [Close] button in the property window.
10. Right-click the updated "Intel(R) 82576 Gigabit Dual Port Network Connection"
adapter and then select [Remove] button.
"Confirm Device Uninstall" is displayed.
Next, click [OK] button.
Don't check the check box "Delete the driver software for this device" in Confirm
Device Uninstall window.
Updating LAN driver 1-9
Hitachi Compute Blade 500 Series LAN Advanced Function Manual (for Intel)
11. Repeat the above steps for the other network devices.
12. After doing the above steps for all network devices, select any of the network
devices and then select [Action]-[Scan for hardware changes].
All network devices are detected and the installed LAN driver software is applied to
the network devices.
13. Check the IP address setting for each of the network devices. When you set an IP
address for a network device, you can find out the check box "Obtain an IP address
automatically" is checked as a default. To specify an IP address, it's necessary that
you change the IP address setting. After changing the IP address setting, check if
the network cable is connected to the destination or not, and then reboot the guest
OS.
When you set up the LAN driver, the message showing that the LAN driver
cannot be used might be displayed. In this case, you can set up normally by
rebooting a guest OS. Then, check if the device works normally or not in
Computer Management window.
Restriction on changing parameters for network adapters. After you change the
parameters for network adapters, the network adapters might not communicate
normally. In this case, check the updated netwrok adapters in Computer
Management window. If "!" for a network adapter is displayed, right-click the
network adapter. Next, disable the network adapter and then enable the network
adapter again.
1-10 Updating LAN driver
Hitachi Compute Blade 500 Series LAN Advanced Function Manual (for Intel)
2
LAN Advanced Functions 2-1
Hitachi Compute Blade 500 Series LAN Advanced Function Manual (for Intel)
LAN Advanced Functions
This chapter describes the supported functions and their setting methods.
Teaming and Tag VLAN Setting (for Windows Server 2008)
Teaming and Tag VLAN Setting (for Windows Server 2008 R2)
2-2 LAN Advanced Functions
Hitachi Compute Blade 500 Series LAN Advanced Function Manual (for Intel)
The kinds of the LAN advanced functions and the ways to set the LAN advanced functions
are explained in this chapter.
It's necessary that you insall "Intel (R) PROSet" to use the LAN advanced
functions. On Windows Server 2012, use the NIC teaming function which is an
original function provided by Windows Server 2012.
The available functions (teaming, tag-VLAN) are shown below.
Adapter Fault Tolerance (AFT)
Feature
Combines two LAN devices and, if a network connection error occurs, automatically
failover to a backup LAN device. The function ensures the network redundancy and
fault tolerance.
Condition
-Connected HUB: Switching HUB
-Two LAN devices must be connected to the same switching HUB. The spanning tree
protocol (STP) must be disabled for the switching HUB.
-Supported protocol: IP
Adaptive Load Balancing (ALB)
Feature
Combines two LAN devices and distributes the traffic load on transmission data to
the devices. The function enhances the network bandwidth.
Condition
-Connected HUB: Switching HUB
-Two LAN devices must be connected to the same switching HUB. The spanning tree
protocol (STP) must be disabled for the switching HUB.
-Supported protocol: IP
Switch Fault Tolerance (SFT)
Feature
Combines two LAN devices with two switching HUBs (active and standby)
corresponding to STP (IEEE802.1d). The function ensures the redundancy of LAN
devices and switching HUBs and provides the highly reliable network.
Condition
-Connected HUB: Switching HUB compliant with IEEE802.1d STP
-Two LAN devices must be connected to different switching HUBs. The spanning tree
protocol (STP) of the switching HUB port must be enabled. But the STP must be
disabled for the Switching HUB port to be connected to the LAN device.
-Supported protocol: IP
TagVLAN IEEE802.1q VLAN
Feature
Identifies a VLAN group based on ID specified for the tag in the packet and provides
the logical segmentation.
Condition
-Connected HUB: Switching HUB compliant with IEEE802.1q VLAN
-Available groups: Up to ten groups (ID: 1-4094) per system
-Supported protocol: IP
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86
  • Page 87 87
  • Page 88 88
  • Page 89 89
  • Page 90 90
  • Page 91 91
  • Page 92 92

Hitachi Compute Blade 500 Series Function Manual

Type
Function Manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI