CCTV Outdoor Power Supplies
Installation Guide
Models Include:
WPTV248UL WPTV248ULCB
- 24VAC @ 3.5 amp (85VA). - 24VAC @ 3.5 amp (85VA).
- Eight (8) Fuse Protected Outputs. - Eight (8) PTC Protected Outputs.
WPTV248175UL WPTV248175ULCB
- 24VAC @ 7 amp (175VA) - 24VAC @ 7 amp (175VA)
or 28VAC @ 6.25 amp (175VA). or 28VAC @ 6.25 amp (175VA).
- Eight (8) Fuse Protected Outputs. - Eight (8) PTC Protected Outputs.
WPTV248300UL WPTV248300ULCB
- 24VAC @ 12.5 amp (300VA) - 24VAC @ 12.5 amp (300VA)
or 28VAC @ 10 amp (280VA). or 28VAC @ 10 amp (280VA).
- Eight (8) Fuse Protected Outputs. - Eight (8) PTC Protected Outputs.
Rev
. 021104
Overview:
These outdoor Altronix CCTV Power Supplies provide power via eight (8) fused or PTC protected outputs for CCTV
Cameras, heaters and other video accessories. Units are UL Listed UL2044 “
U.S. and Canada for CCTV Equipment.”
Eight (8) Output WPTV Reference Chart:
WPTV248UL 24VAC 3.5 amp 8 - x 3.5 amp 3.5 amp/250V .9 amp
WPTV248ULCB 24VAC 3.5 amp 8 x - 2.5 amp - .9 amp
WPTV248175UL
24VAC 7 amp
8 - x 3.5 amp - 1.76 amp
28VAC 6.25 amp
WPTV248175ULCB
24VAC 7 amp
8 x - 2.5 amp - 1.76 amp
28VAC 6.25 amp
WPTV248300UL
24VAC 12.5 amp
8 - x 3.5 amp - 2.7 amp
28VAC 10 amp
WPTV248300ULCB
24VAC 12.5 amp
8 x - 2.5 amp - 2.7 amp
28VAC 10 amp
Specifications:
Installation Instructions:
1. Mount unit in desired location. Use hardware supplied and stainless steel fasteners.
2. Slide switch on PD board to OFF position for models WPTV248UL and WPTV248ULCB
(Fig. 2, pg. 5).
T
ur
n OFF main s
witch on all other models
(F
igs. 3-4, pgs. 6-7).
3.
All units are f
actor
y set for 24V
A
C operation.
For 28VAC operation (for models with 24VAC/28VAC option only), adjust unit prior to mounting and applying
power as follows: Change the wire position so that the black wire [28V] is connected to the terminal marked [P] and
the y
ellow wire [24V] is connected to the terminal marked [S].
4. Before drilling WP enclosure for wire entry, remove back plate (four (4) screws) with all internal parts
(Fig. 2A, pg. 5). For suggested wire entry locations refer to (Fig. 1, pg. 4). Use weather tight NEMA 4 rated
connectors, bushings, and cables.
5. Place back plate with all internal parts (four (4) screws) back into WP enclosure
(F
ig. 2A, pg. 5).
6. Connect AC po
wer to the black and white flying leads of the transformer(s)
(F
igs. 2-4, pgs. 5-7)
, secure g
reen lead
to earth ground. Use 18 AWG or larger for all power connections.
Keep power limited (PTC protected outputs only) wiring separate from non-power limited wiring.
Minimum .25” spacing m
ust be pr
o
vided. Use separate entries.
7. Measure output voltage before connecting devices. This helps avoid potential damage.
Terminals marked [1P - 8P] are of the same polarity.
- 2 -
Altronix
Model Number
Output Current
(max per output)
Total Output Current
(Power)
Output Voltage
115VAC
50/60Hz Input
Current
PTC Protected Outputs
(Class 2 po
wer limited)
Fuse Protected
Outputs
Number of
Outputs
Main Fuse Ratings
on Board
• UL Listed for Commercial CCTV Equipment (UL2044).
CUL Listed - CSA Standard C22.2 No.1-98, Audio,
Video and Similar Equipment.
Surge suppression.
AC power LED indicator.
Power ON/OFF switch / circuit-breaker.
Unit maintains camera synchronization.
Ease of installation saves time & eliminates costly labor.
Spare fuses included (on fuse protected models).
Enclosure Dimensions:
12"H x 8"W x 6"D
- 3 -
CAUTION: Determine the maximum operating voltage of the equipment being powered before adjusting
the output v
oltage.
8.
Connect devices to terminals marked [1P - 1N through 8P - 8N] on PD8/PD8CB board
(F
igs. 2-4, pgs. 5-7),
carefull
y observing polarity.
9. Slide switch on PD board to ON position for models WPTV248UL and WPTV248ULCB
(Fig. 2, pg. 5).
Turn main switch on all other models to the ON (RESET) position
(Figs. 3-4, pgs. 6-7).
10. Green LED will illuminate when unit is powered.
11. Upon completion of wiring, secure enclosure door with the cam lock (supplied).
Caution: Equipment to be installed / serviced by authorized / trained personnel only.
Shut branch circuit power before installing / servicing equipment.
WARNING: This installation should be made by qualified service personnel. Unit should be installed in
accordance with the National Electrical Codes and all local codes. For continued protection against risk
of fire replace all fuses only with the same type and rating
(3.5 amp/250VAC).
Terminal Identification:
PD8 - Power Distribution Module
1P - 8P AC output.
1N - 8N AC output.
- 3 -
- 4 -
Right PanelLeft Panel
Suggested Locations
for Wire Entries
Bottom Panel
Suggested Locations
for Wire Entries
Fig. 1
- 5 -
Fig. 2
WPTV248UL • WPTV248ULCB
PD8
MAIN FUSE
ON OFF
N
COMMON POWER OUTPUTS
P
FUSED POWER OUTPUTS
1
2 3 4 5 6 7 8
ALTRON IX CORP. MADE IN USA
BROOKL YN, NY 11220
D1
INPUT
R1
LED
XFMR
White
Lead
Black
Lead
B
lack
L
ead
non-power 
l
imited
non-power 
limited
115VAC 
Input
50/60 Hz.
Green
Lead
(Ground)
Used on PTC Models
(example: WPTV248ULCB)
N
C
OMMON POWER OUTPUTS
P
F
USED POWER OUTPUTS
ALTRON IX CORP. MADE IN USA
BROOKL YN, NY 11220
D
1
I
NPUT
R1
LED
MAIN
FUSE
F1 F2 F3 F4 F5 F6 F7 F8
PD8
Power Limited 
Class 2
ON OFF
Fig. 2A
24VAC fused or PTC 
protected outputs
1 through 8.
Input:
24VAC 
operation.
Terminal Blocks for Fig. 2
- 6 -
XFMR
White
Lead
non-power 
limited
115VAC Input
5
0/60 Hz.
Green
L
ead
(Ground)
Used on PTC Models
(example: WPTV248175ULCB)
N
COMMON POWER OUTPUTS
P
FUSED POWER OUTPUTS
ALTRON IX CORP. MADE IN USA
BROOKL YN, NY 11220
D1
INPUT
NPS
R1
LED
MAIN
FUSE
F1 F2 F3 F4 F5 F6 F7 F8
PD8
Power Limited 
Class 2
P
ower
S
witch
Fig. 3
WPTV248175UL • WPTV248175ULCB
24VAC or 28VAC
fused or PTC protected outputs
1 through 8.
Input:
24VAC or 28VAC
operation.
Terminal Blocks for Fig. 3
- 7 -
non-power 
limited
115VAC 
I
nput
50/60 Hz.
Green
Lead
(Ground)
Used on PTC Models
(example: WPTV248300ULCB)
N
COMMON POWER OUTPUTS
P
F
USED POWER OUTPUTS
ALTRON IX CORP. MADE IN USA
BROOKL YN, NY 11220
D1
I
NPUT
N
PS
R1
LED
MAIN
FUSE
F1 F2 F3 F4 F5 F6 F7 F8
PD8
Power Limited 
Class 2
P
ower
Switch
XFMR*
White
Lead
Black
Lead
Fig. 4
WPTV248300UL • WPTV248300ULCB
24VAC or 28VAC
fused or PTC protected outputs
1 through 8.
Input:
24VAC or 28VAC
operation.
Terminal Blocks for Fig. 4
- 8 -
Altronix Corp.
140 58th Street, Brooklyn, Ne
w
York 11220 USA, 718-567-8181, fax: 718-567-9056
web site: www.altronix.com, e-mail: [email protected], Lifetime
W
ar
ranty
, Made in U.S.A.
II1WPTV248UL Series F15D
MEMBER
Altronix is not responsible for any typographical errors.
.5"
7.4"
8.77"
2"
0
0
10"
6"
0
0
.75"
.75"
11.25"
12"
8".77"
Enclosure Dimensions
12"H x 8"W x 6"D
The lightning flash with arrow head symbol within an equilateral triangle is intended to alert the user to the
presence of an insulated “D
ANGEROUS VOLTAGE” within the products enclosure that may be of sufficient
magnitude to constitute an electric shock.
The exclamation point within an equilateral triangle is intended to alert the user to the presence of important
operating and maintenance (servicing) instructions in the literature accompanying the appliance.
CAUTION: To reduce the risk of electric shock do not open enclosure. There are
no user serviceable parts inside. Refer servicing to qualified service personnel.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8

Altronix WPTV248175UL Installation guide

Category
Power extensions
Type
Installation guide
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI