TOA TT-104B User manual

Type
User manual
OPERATING INSTRUCTIONS
PROGRAM TIMER TT-104B
Thank you for purchasing TOA Program Timer.
Please carefully follow the instructions in this manual to ensure long, trouble-free use of your equipment.
TABLE OF CONTENTS
1. SAFETY PRECAUTIONS .............................. 2
2. FEATURES .................................................... 3
3. INSTALLATION PRECAUTIONS ................. 3
4. NOMENCLATURE AND FUNCTIONS
[Front] ............................................................. 4
[Rear] ............................................................. 5
5. RACK MOUNTING ........................................ 6
6. OPERATION
6.1. Setting the Current Time ......................... 7
6.2. Time Correction ....................................... 8
6.3. Program Registration .............................. 8
6.4. Program Check,
Correction and Cancellation .................. 10
6.5. Entire Program Cancellation ................. 11
6.6. Program Operation ................................ 11
6.7. Pause Mode .......................................... 11
6.8. Using the AUTO/OFF Switches ............. 12
6.9. Using the MANUAL Keys ...................... 12
6.10. Using the CHANNEL ASSIGNMENT
Switch .................................................... 13
6.11. Points to Remember .............................. 15
6.12. Output Relay ......................................... 15
7. DIMENSIONAL DIAGRAM .......................... 16
8. SPECIFICATIONS ....................................... 16
2
When Installing the Unit
Do not expose the unit to rain or an environment
where it may be splashed by water or other liquids,
as doing so may result in fire or electric shock.
• Use the unit only with the voltage specified on the
unit. Using a voltage higher than that which is
specified may result in fire or electric shock.
• Do not cut, kink, otherwise damage nor modify the
power supply cord. In addition, avoid using the
power cord in close proximity to heaters, and never
place heavy objects -- including the unit itself -- on
the power cord, as doing so may result in fire or
electric shock.
Avoid installing or mounting the unit in unstable
locations, such as on a rickety table or a slanted
surface. Doing so may result in the unit falling
down and causing personal injury and/or property
damage.
Since the unit is designed for in-door use, do not
install it outdoors. If installed outdoors, when it gets
wet with rain, there is a danger of electric shock.
The apparatus shall be connected to a mains
socket outlet with a protective earthing connection.
The socket-outlet shall be installed near the
equipment and the plug shall be easily accessible.
When the Unit is in Use
Should the following irregularity be found during use,
immediately disconnect the power supply plug from
the AC outlet and contact your nearest TOA dealer.
Make no further attempt to operate the unit in this
condition as this may cause fire or electric shock.
· If you detect smoke or a strange smell coming
from the unit.
· If water or any metallic object gets into the unit
· If the unit falls, or the unit case breaks
· If the power supply cord is damaged (exposure of
the core, disconnection, etc.)
• To prevent a fire or electric shock, never open nor
remove the unit case as there are high voltage
components inside the unit. Refer all servicing to
qualified service personnel.
Do not place cups, bowls, or other containers of
liquid or metallic objects on top of the unit. If they
accidentally spill into the unit, this may cause a fire
or electric shock.
Do not insert nor drop metallic objects or
flammable materials in the ventilation slots of the
unit's cover, as this may result in fire or electric
shock.
Do not touch a power supply plug during thunder
and lightning, as this may result in electric shock.
When Installing the Unit
Never plug in nor remove the power supply plug
with wet hands, as doing so may cause electric
shock.
When unplugging the power supply cord, be sure
to grasp the power supply plug; never pull on the
cord itself. Operating the unit with a damaged
power supply cord may cause a fire or electric
shock.
When moving the unit, be sure to remove its power
supply cord from the wall outlet. Moving the unit
with the power cord connected to the outlet may
cause damage to the power cord, resulting in fire or
electric shock. When removing the power cord, be
sure to hold its plug to pull.
1. SAFETY PRECAUTIONS
Before installation or use, be sure to carefully read all the instructions in this section for correct and safe
operation.
• Be sure to follow all the precautionary instructions in this section, which contain important warnings and/or
cautions regarding safety.
After reading, keep this manual handy for future reference.
Safety Symbol and Message Conventions
Safety symbols and messages described below are used in this manual to prevent bodily injury and property
damage which could result from mishandling. Before operating your product, read this manual first and
understand the safety symbols and messages so you are thoroughly aware of the potential safety hazards.
WARNING
Indicates a potentially hazardous situation which, if mishandled, could
result in death or serious personal injury.
Indicates a potentially hazardous situation which, if mishandled, could
result in moderate or minor personal injury, and/or property damage.
WARNING
CAUTION
CAUTION
3
Avoid installing the unit in humid or dusty locations,
in locations exposed to the direct sunlight or flame,
near the heaters, or in locations generating sooty
smoke or steam as doing otherwise may result in
fire or electric shock.
When the Unit is in Use
Do not place heavy objects on the unit as this may
cause it to fall or break which may result in
personal injury and/or property damage. In
addition, the object itself may fall off and cause
injury and/or damage.
• If dust accumulates on the power supply plug or in
the wall AC outlet, a fire may result. Clean it
periodically. In addition, insert the plug in the wall
outlet securely.
Unplug the power supply plug from the AC outlet
for safety purposes when cleaning or leaving the
unit unused for 10 days or more. Doing otherwise
may cause a fire or electric shock.
2. FEATURES
4 independent output channels.
Weekly program capacity is 30 steps per channel, and each step can be programmed in 1-minute units.
A channel assignment switch turns B, C and D outputs into A output.
Programming, its change or cancellation can be performed easily and precisely through individual key
operation and display.
Setting the pause mode allows no program output to be delivered.
Output is a no-voltage make contact that connects for 5 seconds at the programmed time.
Built-in buzzer audibly warns the user of key operation error.
Monthly error is ±5 seconds at 25°C (77°F) of ambient temperature.
Clock and stored programs can be maintained for approximately 100 hours in the event of power outage.
3. INSTALLATION PRECAUTION
The supplied power supply cord is designed for exclusive use with this unit. Never use it with other
equipment.
Do not switch power on and off frequently because this can shorten the power-outage backup time.
Be sure to set the memory backup switch to ON after installation.
Do not install the unit close to a warm air vent or in locations where the unit is exposed to the sunlight.
Installation in high temperature areas like on the amplifier makes a clock inaccurate. Install the unit in the
area of which temperature is as close as possible to the room temperature.
Install the unit as far as possible from a radio tuner or a wireless microphone.
Be sure to ground the unit.
Be sure to unplug power cord from the wall outlet when making connections.
WARNING: (FOR U.S.A. only)
This equipment generates, uses, and can radiate radio frequency energy and if not installed and used in
accordance with the operating instructions, may cause interference to radio communications. It has been
tested and found to comply with the limits for a Class A computing device pursuant to Subpart J of Part
15 of FCC Rules, which are designed to provide reasonable protection against such interference when
operated in a commercial environment.
Operation of this equipment in a residential area is likely to cause interference in which case the user at
his own expense will be required to take whatever measures may be required to correct the interference.
4
1 2 3 4 5 6 7
8
9
10
11
12
13 14 15
Day indicators
Second indicator (colon)
Channel indicators
Pause mode indicator
Time mode indicator
Day mode indicator
Clock display
4. NOMENCLATURE AND FUNCTIONS
[Front]
1. Program switch
Set this switch to OPERATION when setting a
clock for the current time or when letting the timer
work. Set the switch to PROGRAM to perform
programming. (Factory-preset: OPERATION)
Note: The timer does not operate if the program
switch is set to PROGRAM. Be sure to set it
to OPERATION normally.
2. Day setting keys
To program a current day of the week into the
timer, press this setting key with the ADJUST key
(4) pressed continuously. This key is also used to
register the day of the week of timer program.
3. Clock setting keys
Use these keys to set a clock for the current time.
To do this, press this setting key with the ADJUST
key (4) pressed continuously. These setting keys
are also used to set the time of the timer program.
Note: Each time this setting key is pressed, the
number over the setting key pressed
increases by one.
4. ADJUST key
Pressing this key continuously, press the Clock
setting key (3), Day setting key (2), or 00 SEC key
(5) to set a clock for the current time.
5. 00 SEC key
Use this key to adjust a clock to seconds. As soon
as the key is pressed with the ADJUST key (4)
pressed continuously, the clock is reset to zero
second and a new counting of second gets
started.
In this case, when the clock counting is between
30 and 59 seconds, the minute indication
automatically increases by one.
Note: This key works only when the program
switch is set to OPERATION.
6. CHANNEL keys
Use these keys to select the program output.
Pressing the key causes the corresponding
channel indicator on the right side of each key to
come on.
7. DAY mode key
This key is used to register a weekly program.
Press the key, and the Day indicators from
Monday to Sunday flash, allowing a day of the
week to be set with the Day setting key (2) under
each indicator.
8. PAUSE mode key
When it is desirable to stop the clock operation
temporarily on a certain day because that day
falls on a holiday, this can be accomplished by
using this key. After pressing this key (the Day
indicators flash), press the desired Day setting
key (2) to set the pause day.
9. TIME mode key
Press this key to register the clock program, and
the clock display flashes. Set time with the Clock
setting keys (3) under the display.
10. STORE key
Press this key to store the day of the week or
time set under the day, time or pause mode.
Note: No programs can be stored in a built-in
memory unless this key is pressed.
11. CANCEL key
This key cancels the stored day of the week or
time.
To cancel the day of the week, press the CHECK
key (12) to call up the day of the week and
cancel it with the CANCEL key.
Similarly, the stored time can be cancelled with
both the CHECK key (12) and CANCEL key.
5
16 17 18 19 20
[Rear]
16. AC power inlet
Connect the supplied power cord to this inlet.
17. Earth terminal
Be sure to ground the unit.
18. OUTPUT CHANNEL terminal
Output capacity:
24 V DC, 0.5 A (resistance load)
Minimum load: 10 mV DC, 10 μA.
A relay contact closes for 5 seconds at the
programmed time.
These relays provide dry contacts.
• Connect this terminal to start terminals of BGM
player or spot announcing machines, etc.
19. MEMORY BACK UP switch
Be sure to set this switch to ON after installation.
This switch allows clock and stored programs to
be retained for approximately 100 hours during
power outage. (Factory-preset: OFF)
20. CHANNEL ASSIGNMENT switch
Set each switch to ON when assigning all of B, C
and D output channels to the A output channel.
When, for example, the B channel switch is set
to ON, the A channel relay contact closes at the
time programmed for both A and B channels. In
this event, the B control output does not work.
(Factory-preset: OFF)
12. CHECK key
This key checks the day of the week or time for
proper registration.
The corresponding Day indicator comes on when
checking the day of the week.
Also, each time this key is pressed, the clock
display shows the programmed times from the
earliest time to the latest in sequence.
13. AUTO/OFF switches
Each individual output channel can be connected
and disconnected with this switch.
Setting the switch to ON allows the corresponding
output channel to operate at the programmed
time.
When set to OFF, the output operation stops.
(Factory-preset: OFF)
14. MANUAL keys
Use these keys to manually deliver the output
regardless of actual program. Pressing each key
closes a relay contact for 5 seconds.
Notes
The connected equipment can be manually
activated with the keys regardless of program
as well as position of the AUTO/OFF switches
(13).
The keys cannot be operated during power
outage.
15. OUTPUT identification label
This label is supplied with the unit.
Write the names of programs of or equipment
connected to each output channel in the label.
6
5. RACK MOUNTING
To mount the unit in a standard 19" equipment rack, the rack mounting bracket MB-15B (optional) is required.
Follow the procedures below.
Step 1. Remove the rubber feet from the bottom of the unit.
Step 2. Attach the rack mounting bracket MB-15B to the unit.
Rack mounting bracket MB-15B
(optional)
Tapping screw 3 x 8
(supplied with the MB-15B)
Rack mounting screw 5 x 12
(supplied with the MB-15B)
Fiber washer for M5
(supplied with the MB-15B)
TT-104B
Rack
Step 3. Fix the unit in the rack.
Use the rack mounting screws that are appropriate for the rack.
Note
The rack-mounting screws supplied with the MB-15B can be used for the TOA equipment rack only.
Illustrated below is a unit mounting method to the TOA rack.
7
6. OPERATION
6.1. Setting the Current Time
Step 1. Plug power cord in wall outlet.
Step 2. Set the Program switch to OPERATION.
The clock display flashes to show “0000” and at the same time, a warning tone beeps, indicating that
the timer has to be set for current time.
Step 3. Set the rear-mounted MEMORY BACK UP switch to ON.
The switch allows a clock to work and the stored programs to be retained during power outage, but no
timer output is delivered.
Step 4. Press the Day setting key (from Monday to Sunday) with the ADJUST key continuously pressed to set
a day of the week.
The corresponding Day indicator comes on, while a Second indicator (colon) in indication “00:00” that
appears in the clock display begins to flash at one second intervals, indicating that a clock is working.
The beep stops.
Step 5. Pressing the ADJUST key continuously, press the Clock setting keys (HOUR and MIN) to set a clock
for current time.
The number increases by one each time the setting key is pressed. If the unreal time is set which is
not in a range from zero hour (00:00) to 23 hours and 59 minutes (23:59), both the Day indicator and
clock display flash and at the same time, a warning tone beeps. In such a case, correct the time.
Step 6. Press the 00 SEC key, while pressing the ADJUST key continuously.
This resets the second of a clock to “00.”
In this case, when the clock counting is between 30 and 59 seconds, the minute indication
automatically increases by one. The minute indication does not change when the second is between
0 and 29 seconds.
(The clock display shows no second, but the clock is working in second.)
Day indicators
Program switch Day setting keys
MEMORY BACK UP
switch
CHANNEL ASSIGNMENT
switch
Clock setting keys
MANUAL keys
AUTO/OFF switches
ADJUST key
00 SEC key
PAUSE mode key
CANCEL key
CHECK key
TIME mode key
CHANNEL keys
Channel indicators
Second indicator (colon)
Clock display
[Front]
[Rear]
Time mode indicator
STORE key
Day mode indicator
DAY mode key
Pause mode indicator
8
6.3. Program Registration
Step 1. Enter programs in the program table supplied with the unit.
Lump the programs together per equipment connected and assign the output channel to each
equipment.
If the same equipment are used but their programs are not the same, assign different output
channels.
[Example]
If it is so programmed as to sound a chime both in the morning and in the afternoon of Monday
through Friday, and in the morning of Saturday, and to play a piano accompaniment to the morning
announcement every morning from Monday through Saturday, write on the table as follows.
Output channel
Equipment
Day
Mon Tue Wed Thu Fri Sat Sun
Time Hour Minute Note
10900
1200
1245
1500
1505
1730
Start of work
Lunch break
Close of lunch break
Afternoon tea break
Close of tea break
Close of work
2
3
4
5
6
7
8
9
Chime
A
Mon Tue Wed Thu Fri Sat Sun
Hour Minute Note
0900
1200
Start of work
Close of work
Spot announcing machine
B
Mon Tue Wed Thu Fri Sat Sun
Hour Minute Note
0840
Morning announcement
C
Program
PROGRAM TABLE
Note
The output of the TT-104B is a relay contact that closes for 5 seconds at the programmed time.
The relay contact cannot be kept closed or open by programs. Take care that equipment to accept the
pulse output are connected to the timer.
Step 1. Check to confirm that the Program switch is set to OPERATION.
Step 2. Pressing the ADJUST key continuously, press the 00 SEC key the moment the radio time signal tells
zero second.
This allows the clock to be timed to the moment when the clock error is between 0 and 29 seconds.
If the clock error is more than 30 seconds, use the Clock setting keys while pressing the ADJUST key
continuously so that the clock display indicates the correct time.
Note
The second of the clock is not reset to zero second even when a day of the week and the current time
are set.
6.2. Time Correction
9
Step 2. Program registration
Register the programs according to the contents written in the program table.
2-1. Set the Program switch to PROGRAM.
The Channel indicators (A, B, C, and D) and Pause mode indicator flash.
2-2. Press the A channel key to select the A channel.
The A channel indicator comes on, while both the Day mode and Time mode indicators flash.
2-3. Press the DAY mode key to put the timer in the day mode.
The Day mode indicator comes on. At the same time, the Day indicators from Monday to Sunday
flash.
2-4. Press the Day setting key (from Monday to Friday) to designate a day of the week.
Note
When the wrong Day setting key has been pressed, press the same setting key again, and the
corresponding Day indicator goes out. Then press the correct setting key.
2-5. Press the STORE key to register the day of the week.
The clock display indicates “PASS.” At this point, all days from Monday to Friday have been
registered into the A channel.
Note
The contents of the programs are not stored without pressing the STORE key.
2-6. Press the TIME mode key to put the timer in the time mode.
The Time mode indicator comes on. At the same time, a dotted line “– – – –“ flashes in the clock
display.
2-7. Set a clock for 08:55.
Press the HOUR key (one hour’s digit) 8 times.
The clock display shows “0800.”
Press the MIN key (ten minute’s digit) 5 times.
The clock display shows “0850.”
Press the MIN key (one minute’s digit) 5 times.
The clock display shows “0855.”
2-8. Press the STORE key to register the time 08:55.
The word “PASS” appears in the clock display, indicating the time 08:55 has been registered into the
A output channel.
Note
The content of the program is not stored without pressing the STORE key.
2-9. Repeat Steps 2-7 and 2-8 to register all the times from 09:00 to 17:30.
Notes
Pressing the STORE key to register the unreal time other than one from 00:00 to 23:59 causes
characters “Err” to appear in the clock display and the attempt of its registration is refused. Correct
the time and register it again.
• When the same time is registered double, characters “Err” are indicated in the clock display.
If a registration attempt is made in excess of the program capacity (30), the word “End” appears in
the clock display, refusing the registration.
2-10. Repeat Steps 2-2 through 2-9 to register days of the week and times into both B and C channels.
One minute's digit
Ten minute's digit
One hour's digit
Ten hour's digit
MINHOUR
10
6.4. Program Check, Correction and Cancellation
After finishing program registrations, check the program contents.
Step 1. Set the Program switch to PROGRAM.
The Channel indicators (A, B, C, and D) and Pause mode indicator flash.
Step 2. Press the A channel key to select the A channel.
The A channel indicator comes on, while both the Day mode and Time mode indicators flash.
Step 3. Press the DAY mode key to put the timer in the day mode.
The Day mode indicator comes on. At the same time, the Day indicators from Monday to Sunday
flash.
Step 4. Press the CHECK key to check the registered day of the week.
The indicator of the registered day of the week comes on.
[Correcting the day of the week]
After pressing the desired Day setting key, press the STORE key.
[Cancelling the day of the week]
Press the CANCEL key.
The word “PASS” is indicated in the display and all Day indicators from Monday to Sunday go out,
achieving the cancellation.
Step 5. Press the TIME mode key to put the timer in the time mode.
The Time mode indicator comes on. At the same time, a dotted line “– – – –“ flashes in the clock
display.
Step 6. Press the CHECK key to check the registered time.
Each time the CHECK key is pressed, the registered time is shown in the clock display starting first
with the earliest time to the latest in sequence.
Pressing the CHECK key when the last time is indicated causes the word “End” to appear in the clock
display, returning the indication to the first time.
[Correcting the time]
(1) Press the CHECK key till that time appears in the display.
(2) Press the CANCEL key for cancelling the indicated time and then set the new time using the
Clock setting keys (HOUR and MIN).
(3) Register the new time with the STORE key.
Note: Be sure to cancel the previous time when correcting it.
[Cancelling the registered time]
(1) Press the CHECK key to get that time in the clock display.
(2) Press the CANCEL key. The word “PASS” appears in the display and that time has been
cancelled.
In this event, that cancelled time remains indicated in the display.
Further cancellations can be achieved in a similar manner by using both the CHECK and
CANCEL keys.
Note: Pressing the CHECK key when no time is registered results in “End” being indicated in the
display, with “Err” indicated when the CANCEL key is pressed.
11
6.5. Entire Program Cancellation
It is impossible to simultaneously cancel all the programs registered into all channels.
Cancellation is only possible for each channel (A, B, C and D).
Follow the procedures below to cancel the A channel time program.
Step 1. Set the Program switch to PROGRAM.
The Channel indicators (A, B, C, and D) and Pause mode indicator flash.
Step 2. Press the A channel key to select the A channel.
The A channel indicator comes on, while both the Day mode and Time mode indicators flash.
Step 3. Press the TIME mode key to put the timer in the time mode.
The Time mode indicator comes on. At the same time, a dotted line “– – – –“ flashes in the clock
display.
Step 4. Press the CANCEL key with the A channel key continuously pressed.
The word “PASS” appears in the display, indicating that the whole time program registered into the A
channel has been cancelled.
Similarly, the whole time program registered into each of the B, C and D channel can be cancelled.
For the day of the week, perform individual cancellations as instructed in the section 6.4. "Program Check,
Correction and Cancellation."
6.6. Program Operation
Be sure to set the Program switch to OPERATION after programming is finished.
The timer does not work if the switch is set to PROGRAM.
6.7. Pause Mode
The PAUSE mode key is used to temporarily make the timer not to function on particular days. This is
possible for up to the 7th day from the day of registration.
No output is delivered from the timer on a day set for pause.
After the pause day is over, the timer automatically returns to the normal state.
Use the pause function in such a case as the following example.
[Example]
Today is Friday and we want to stop the timer operation on Monday through Wednesday of next week since
our office is closed on these three days due to holidays.
Note: When it is on Monday that Monday is registered for pause mode, the pause day is a Monday of the
following week. Follow the procedures below to make Monday through Wednesday the pause days as
in the example.
Step 1. Set the Program switch to PROGRAM.
The Channel indicators (A, B, C and D) and Pause mode indicator flash.
Step 2. Press the PAUSE mode key.
The Pause mode indicator comes on, while the Day indicators from Monday to Sunday flash.
OPERATION
PROGRAM
12
Step 3. Press the Day setting keys (Monday, Tuesday and Wednesday) to designate a day(s) of the week.
Each corresponding Day indicator comes on.
Note
When the wrong Day setting key has been pressed, press that setting key again. The Day indicator
goes out.
Step 4. Press the STORE key to register the day of the week.
The word “PASS” appears in the clock display, indicating that the three days have been registered for
pause.
Note
The contents of the program are not registered without pressing the STORE key.
Notes
• When the current day is set after the pause registration, perform the new pause registration.
• Set the Program switch to OPERATION after finishing programming.
6.8. Using the AUTO/OFF Switches
The AUTO/OFF switches (front-mounted) are used to stop actions of output relays regardless of the timer
program.
When the switch is set to AUTO, the relay functions as programmed.
Setting the switch to OFF does not activate the relay.
The switchover is possible per channel.
6.9. Using the MANUAL Keys
Use the MANUAL keys (front-mounted) to activate the output relay regardless of the timer program.
Pressing the key causes the output relay to close for 5 seconds. This is possible for each individual output.
Use the keys when performing a test at time of equipment installation or for other purposes that necessitate
the manual relay activation regardless of the timer program.
Note
These keys do not work during power outage.
These keys work regardless of the front-mounted AUTO/OFF switch setting.
13
6.10. Using the CHANNEL ASSIGNMENT Switch
The CHANNEL ASSIGNMENT switch (rear-mounted) is used to switch over from the B, C or D channel to the
A channel.
When the B channel switch is set to ON, the B program output is delivered from the A channel, with the A
program output delivered from the A channel. In this event, no output is delivered from the B channel.
[Example 1]
Given that each of the output channels is programmed as Example 1,
the output is delivered from each channel as follows.
If all the switches are set to OFF.
A channel: Output is delivered at 8:30, 9:30 and 10:30.
B channel: Output is delivered at 9:00, 10:00 and 11:00.
C channel: Output is delivered at 12:00.
If both the B and C switches are set to ON.
A channel: Output is delivered at 8:30, 9:00, 9:30, 10:00, 10:30, 11:00, and 12:00.
No output is delivered from both the B and C channels.
6.10.1. The CHANNEL ASSIGNMENT switch vs. AUTO/OFF switches
The AUTO/OFF switches (front-mounted) are effective for the program registered into each output.
If the CHANNEL ASSIGNMENT switch of B channel is set to ON and the AUTO/OFF switch of A channel to
OFF in Example 1.
A channel delivers output at 9:00, 10:00 and 11:00.
B channel delivers no output.
C channel delivers output at 12:00.
Tips
Since the A AUTO/OFF switch is set to OFF, the output is not delivered from the A channel at 8:30, 9:30 and
10:30 as programmed.
Since the B channel is switched over to the A channel, the A channel delivers output at 9:00, 10:00 and
11:00, the times programmed into the B channel.
If the A channel MANUAL key is pressed under these conditions, the A output relay makes for 5 seconds.
Pressing the B channel MANUAL key causes the A channel relay to close for 5 seconds because the B output
is switched over to the A channel.
ABC
8:30 9:00 12:00
9:30 10:00
10:30 11:00
BOFF
ON
C
A
D
BOFF
ON
C
A
D
BOFF
ON
C
A
D
AUTO OFF
A
B
C
D
14
6.10.2. Use the CHANNEL ASSIGNMENT switch in such cases as shown below:
(1) To allow one single equipment to process four different programs through combined use of the CHANNEL
ASSIGNMENT switch (rear-mounted) and the AUTO/OFF switch (front-mounted).
When, for example, the school has the Westminster chime and they want to utilize it for the following four
different programs.
1) Ordinary school hour program (Monday to Friday)
2) Saturday program
3) Temporary shorter school hour program
4) Examination day program
1) Register the ordinary school hour program into the A channel. (Register Monday through Friday.)
2) Register the Saturday program into the B channel. (Register Saturday.)
3) Register the temporary shorter school hour program into the C channel. (Register Monday through
Saturday.)
4) Register the examination day program into the D channel. (Register Monday through Saturday.)
Set the CHANNEL ASSIGNMENT switches B, C and D to ON.
1) To operate the ordinary school hour program and Saturday program
Set the AUTO/OFF switch to AUTO for the A and B channels, and to OFF for the C
and D channels. This allows the ordinary school hour program to be operated on
Monday through Friday, and the Saturday program on Saturday.
2) To operate the shorter school hour program
Set the AUTO/OFF switch of the C channel to AUTO, and those of other channels
to OFF.
3) To operate the examination day program
Set the AUTO/OFF switch of the D channel to AUTO, and those of other channels
to OFF.
Thus, by shifting the AUTO/OFF switches different programs can be readily operated.
BOFF
ON
C
A
D
AUTO OFF
A
B
C
D
AUTO OFF
A
B
C
D
AUTO OFF
A
B
C
D
15
6.11. Points to Remember
• All the indications go out at time of power outage. However, a clock works normally and stored programs are
maintained. No relay output is produced. After power restoration, the timer works normally and indicates the
current time.
• A clock and stored programs are maintained for about 100 hours during power outage.
If the clock display flashes to indicate “0000” with beep after power restoration, this indicates that the battery
has run down. In such a case, set a clock for the current time and register the program again.
• The 100-hour power outage protection is subject to the battery being kept fully charged. It takes about 200
hours to fully charge the battery. Frequent occurrence of power outage shortens the 100-hour protection
time.
6.12. Output Relay
• Output is a no-voltage (dry) make contact.
• The relay contact closes for 5 seconds at preset time (pulse output system).
• Output relay contact capacity: Maximum: 24 V DC, 0.5 A (resistance load)
Minimum: 10 mV DC, 10μA
BOFF
ON
C
A
D
AUTO OFF
A
B
C
D
(2) If exceeding per-channel program capacity of 30.
When, for example, a frequently-used spot announcing machine needs to be activated 80 times a day.
Set the CHANNEL ASSIGNMENT switches (rear-mounted) of both B and C
channels to ON.
Set the AUTO/OFF switches (front-mounted) of A, B, and C channels to AUTO and
that of D channel to OFF.
This expands a program capacity to 80, with 30 being programmable into A channel, another 30 into B
channel and 20 into C channel.
133-05-276-5B
URL: http://www.toa.jp/
8. SPECIFICATIONS
Note: The design and specifications are subject to change without notice for improvement.
• Accessories
Power cord (2 m or 6.56 ft) ............................... 1
Program table ................................................... 1
Output identification label .................................. 1
• Optional product
Rack mounting bracket: MB-15B
AC mains, 50/60 Hz
3 W
Day of the week, hour and minute
Day of the week, hour, minute, output channel
4 channels (A, B, C, D)
No-voltage (DRY) make contact (5 second pulse make output)
24 V DC, 0.5 A
M4 screw terminal, distance between barriers: 9 mm (0.35")
30 steps per channel
±5 seconds per month (25°C or 77°F)
100 hours
Entire program cancellation, output switchover, pause mode,
warning by tone and indication
0°C to +50°C (32°F to 122°F)
Panel: Aluminum, black, 30% gloss, paint
Case: Pre-coated steel plate, black
420 (w) x 47.5 (h) x 246.5 (d) mm (16.54" x 1.87" x 9.71")
2.5 kg (5.51 lb)
Power Source
Power Consumption
Displayed Contents
Programmable Items
Number of Channels
Output System
Output Capacity
Output Terminal
Program Capacity
Clock Accuracy
Power Outage Protection Period
Special Functions
Operating Temperature
Finish
Dimensions
Weight
Traceability Information for Europe (EMC directive 2004/108/EC)
Manufacturer:
TOA Corporation
7-2-1, Minatojima Nakamachi, Chuo-ku, Kobe, Hyogo,
Japan
Authorized representative:
TOA Electronics Europe GmbH
Suederstrasse 282, 20537 Hamburg,
Germany
7. DIMENSIONAL DIAGRAM
[Front]
[Side]
420 (16.54)
)56.0( 5.61)89.8( 822
246.5 (9.71)
44.5
(1.75)
47.5
(1.87)
Unit: mm (inches)
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16

TOA TT-104B User manual

Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI