Broan P66W Installation guide

Type
Installation guide

This manual is also suitable for

INSTALLATION
1. WARNING
Toavoidreorelectricalshock,turnoffpoweratcircuit
breakerorfuse.Testthatthepowerisoffbeforewir-
ing.
2. MOUNT THE SWITCH BOX
For 2-Rocker Switch: Install a 3½" deep single-gang
switchboxora2"deepdouble-gangswitchbox.
For 3-Rocker Switch:Installa2½"deepdouble-gang
switchboxwithasingledeviceadapterplate.
3. ATTACH POWER CABLE
Clampwiringtoswitchboxandunitusingappropriate
clamp.Provide6"leadsinsideboxandfanforeasier
wiring.
4. CONNECT WIRING
Generalinstructionsforallcongurations:
Makesureboththeswitchboxandtheapplianceare
properlygrounded.
Makesuregroundwireissecurelyfastenedtocontrol's
groundscrew.Tightengroundscrew14to16-in.lbs.
torque.
Removeinsulationperstripgaugeoncontrol(approx.
5/8").Useproperwirenutsizesfornumberandsizeof
wires.
Forpush-interminals:Use#14-AWGsolidcopperwire
only.
Forscrewterminals:Use#12or#14-AWGsolidcop-
perwireonly.Tightenscrewterminals14to16-in.lbs.
torque.
Choose 4A., 4B. or 4C
4A.Whenusing2-Rockeror3-RockerSwitchtoturn
anapplianceON&OFF:
Make electrical connections following appropriate
diagram.
(over)
WARNING
Topreventseriousinjuryfromelectricalshockordamage
toelectricalcomponents-DO NOT WIRE HOT!
Eachindividualrockerswitchonthiscontrolisratedat15
AMPS,@120VAC.Thetotalloadonthiscontrolmust
notexceed20AMPS,@120VAC.
Warrantyisvoidifmiswired.
WARNING
ALL ELECTRICAL WORK MUST BE DONE IN
ACCORDANCEWITHLOCALCODES,ORDINANCES,
ORNATIONALELECTRICALCODEASAPPLICABLE.
FOR SAFETY, THIS PRODUCT MUST BE INSTALLED IN
A GROUNDED SWITCH BOX.IFYOUAREUNFAMILIAR
WITH METHODS OF INSTALLING ELECTRICAL
WIRING, SECURE THE SERVICES OF A QUALIFIED
ELECTRICIAN.
Turnoffpowerandlockoutservicepanelbeforeinstalling
orwiringthisproduct.
Usethiscontrolonlywithcopperorcopper-cladwire.Do
notusealuminumwirewiththisdevice.
2-ROCKER & 3-ROCKER SWITCHES
3-ROCKERSWITCH
2-ROCKERSWITCH
STEP 4A
NOTE: Iftheswitchhasnotbeenwiredproperlyandwiresneed
tobemoved,proceedasfollows:
WARNING: Toavoidreorelectricalshock,turnoffpowerat
circuitbreakerorfuse.Testthatthepowerisoff
beforewiring.
1.Each wireopening hasa
releaseslot.
2. Push a small nail or
screwdriver into release
slotwhilegentlyremoving
wire.
3. DO NOT pull any wire
out of the switch without
using the release slot.
Theswitchmaybecome
damaged.
RELEASESLOT
WIREOPENING
C O M
B L A C K
W H I T E
G R O U N D
G R D
B L A C K
W H I T E
G R O U N D
1 2 0 V A C
L I N E I N
L O A D
1
L O A D
2
S I N G L E - G A N G
S W I T C H B O X
A P P L I A N C E
R E D
CO M
GR D
BL A CK
WH I TE
DO U BLE - GANG SWI T CH B O X
(w i th s ingl e de v ice a dap t er p l ate )
AP P LIA N CE
GR O UND
12 0 VA C
LI N E I N
BL A CK
WH I TE
BL A CK
WH I TE
GR O UND
LO A D
1
LO A D
2
LO A D
3
RE D
FROM
HOOD
2-ROCKER
SWITCH
WHITE
BLACK
RED
GROUND
** INTERMEDIATE
HOODS
4B.Whenusinga2-RockerSwitchtoturnarangehood
ON & OFF from another location with 120 VAC
POWERCABLEENTERINGSWITCHBOX:
Removetherangehood’swiringcover.Ifthehood
hasaBLACKJUMPERWIRE,itmustbecutand
theendstrippedasshown.(FIG.I)
UseULapprovedclampstosecureallcablesto
hoodandbox.Makewiringconnectionsfollowing
appropriate diagram. Use proper wire nut sizes
fornumberandsizeofwires.Replacerangehood
wiringcover.
4C. Whenusinga2-RockerSwitchtoturnarangehood
ON & OFF from another location with 120 VAC
POWERCABLEENTERINGHOOD:
Removetherangehood’swiringcover.Ifthehood
hasaBLACKJUMPERWIRE,itmustbecutand
theendstrippedasshown.(FIG.I)
UseULapprovedclampstosecureallcablesto
hoodandbox.Makewiringconnectionsfollowing
appropriate diagram. Use proper wire nut sizes
fornumberandsizeofwires.Replacerangehood
wiringcover.
5. MOUNT CONTROL IN SWITCH BOX
Tuckwiresintoswitchboxandfastenthecontrolto
boxusingattachedscrews.
6. ATTACH SWITCH PLATE
Fastentheswitchplatetothecontrolusingtheshort
screwsfromthepartsbag.
* 2-SPEED RANGE HOODS:
Broan40000,F40000,41000,42000,43000,52000,
53000,PM25,&QS1Series,NautilusNV,NW,&NX
Series
** INTERMEDIATE RANGE HOODS:
Broan46000,QT20000,&PM44Series
FIG. I
* 2- SPEED
HOODS
** INTERMEDIATE
HOODS
CUTBLACK
JUMPERWIRE
HERE!
CUTBLACK
JUMPER
WIREHERE!
STEP 4B
POWER INTO SWITCH
STEP 4C
POWER INTO HOOD
CODEREQUIRESBOTH
ENDSOFTHISWIRE'S
INSULATIONTOBECOL-
ORED.USEAPERMA-
NENTMARKER.
* 2- SPEED
HOODS
RED
BLACK
BLUE
RED
WHITE
BLUE
RED
99043739B
PK92824-10-00-0E
FROMSWITCH
BOX
REF. FIG 1
WHITE
BLUE
BLACK
BLACK
GRN
** INTERMEDIATE
HOODS
REF. FIG 1
BLUE
BLACK
REF. FIG 1
* 2- SPEED
HOODS
BLACK
GROUND
120VAC
LINEIN
TOSWITCH
BOX
BLACK
WHITE
GROUND
120VAC
LINEIN
TOSWITCH
BOX
WHITE
BLACK
BLACK
BLACK
REF. FIG 1
GRN
RED
BLACK
WHITE
FROMSWITCH
BOX
BROAN-NUTONE LLC ONE YEAR LIMITED WARRANTY
Broan-NuToneLLCwarrantstotheoriginalconsumerpurchaserofitsproductsthat
suchproductswillbefreefromdefectsinmaterialsorworkmanshipforaperiodof
oneyearfromthedateoforiginalpurchase.THEREARENOOTHERWARRANTIES,
EXPRESSORIMPLIED,INCLUDING,BUTNOTLIMITEDTO,IMPLIEDWARRANTIES
OFMERCHANTABILITYORFITNESSFORAPARTICULARPURPOSE.
Duringthisone-yearperiod,Broan-NuToneLLCwill,atitsoption,repairorreplace,
withoutcharge,anyproductorpartwhichisfoundtobedefectiveundernormaluse
andservice.
THISWARRANTY DOES NOT EXTEND TO FLUORESCENT LAMPSTARTERS
ANDTUBES.Thiswarrantydoesnotcover(a)normalmaintenanceandserviceor
(b)anyproductsorpartswhichhavebeensubjecttomisuse,negligence,accident,
impropermaintenanceorrepair(otherthanbyBroan-NuToneLLC),faultyinstallation
orinstallationcontrarytorecommendedinstallationinstructions.
Thedurationofanyimpliedwarrantyislimitedto theone-yearperiodasspecied
fortheexpresswarranty.Somestatesdonotallowlimitationonhowlonganimplied
warrantylasts,sotheabovelimitationmaynotapplytoyou.
BROAN-NUTONE LLC’S OBLIGATION TO REPAIR OR REPLACE, AT BROAN-
NUTONELLC’SOPTION,SHALLBETHEPURCHASER’SSOLEANDEXCLUSIVE
REMEDYUNDERTHISWARRANTY.BROAN-NUTONELLCSHALLNOTBELIABLE
FORINCIDENTAL,CONSEQUENTIALORSPECIALDAMAGESARISINGOUTOF
ORINCONNECTIONWITHPRODUCTUSEORPERFORMANCE.Somestatesdo
notallowtheexclusionorlimitationofincidentalorconsequentialdamages,sothe
abovelimitationorexclusionmaynotapplytoyou.
Thiswarrantygivesyouspeciclegalrights,andyoumayalsohaveotherrights,which
varyfromstatetostate.Thiswarrantysupersedesallpriorwarranties.
Toqualify for warranty service, youmust (a) notify Broan-NuTone LLCat the ad-
dressstatedbelow ortelephone:1-800-637-1453, (b)givethe modelnumberand
partidenticationand(c)describethenatureofanydefectintheproductorpart.At
thetimeofrequesting warrantyservice,youmust presentevidenceofthe original
purchasedate.
BROAN-NUTONE LLC,926WestStateStreet,Hartford,WI53027
WHITE
2-ROCKER
SWITCH
RED
BLACK
BLACK
GROUND
WHITE
WHITE
120 VAC
LINE IN
TO
HOOD
  • Page 1 1
  • Page 2 2