MAHLE Aftermarket GmbH
Pragstr. 26–46
D–70376 Stuttgart
www.mahle-aftermarket.com
000007737.03/13
2. Selection and function keys
Keys Name Function
OOK Confirm and store
Function depends on current menu
Back
Cancel
Back one menu level or cancel
or Up or down control
or Right or left control
Enter Confirm and store
CDelete Deletes character to left of cursor
iInformation Show current data
Switching between number and
letter input. Current mode is shown
at bottom right of screen.
3. Refrigerant identification unit
DBefore connecting service hoses proceed as follows:
1. Verify that the oil system type matches between the actual
vehicle A/C system and current configuration of the ACS
unit (PAG or POE). If required change oil type in “Settings
>> A/C Service Parameter” (see operating instructions
chapter 4.4).
2. Perform refrigerant identification (see operating instructions
chapter 6.3).
DUse of a refrigerant identifier reduces the risk of contamina-
tion of ArcticPro 200yf. If the service hoses are connected to
the vehicle before refrigerant identification there is the risk for
contamination the refrigerant system of ArcticPro 200yf.
MThe contamination in the ArcticPro 200yf can only be removed
by a service provider at additional cost.
DThe type of oil (PAG or POE) is always to be checked prior to
A/C service and altered to suit the type of vehicle.
3.1 Refrigerant analysis
MBefore first operation with refrigerant identifier please read
chapter 3.4 in Original instructions of ArcticPro 200yf.
1. Switch on the ArcticPro 200yf.
2. Select vehicle A/C service.
3. Switch on the refrigerant identification unit.
4. Follow the menu prompting of ArcticPro 200yf.
MGetting message “ Sample not OK ”, check for contamina-
tion of the test hose, then repeat the procedure up to 2 times.
MGetting message “ Sample not OK ” for three times, a
refrigerant verification must be performed.
3.2 Refrigerant verification
MConnect refrigerant identification unit to an external R1234yf
bottle with 100 % R1234yf.
1. Connect refrigerant identification unit to the power supply.
2. Switch on the refrigerant identification unit.
MDo not connect USB connecting cable with ArcticPro 200yf.
3. Follow the menu prompting of refrigerant identification unit.
MContact customer service after not passed analysis for 3 times.