GSi PNEG-377 User manual

Type
User manual
Fan And Heater
PNEG-377
Service
Manual
2000
EDITION
3
Fan and Heater
TABLE OF CONTENTS
Roof Warning, Operation & Safety ................................................................................. 4
Safety Alert Decals ..................................................................................................... 5
2000 Vane Axial Fans ................................................................................................... 8
2000 Centrifugal Fan Service Guide ............................................................................. 17
2000 Gas Heater Service Guide ................................................................................... 24
All Gas Heater Specifications ............................................................................... 25
Series 2000 Heater .............................................................................................. 34
Deluxe Heater .................................................................................................... 52
Standard Heater ................................................................................................... 57
1996-1994 Gas Heaters .............................................................................................. 62
1993-1991 Gas Heaters .............................................................................................. 70
1990 Gas Heaters ....................................................................................................... 73
Pre 1990 Gas Heaters ................................................................................................... 76
Miscellaneous Information ............................................................................................. 83
Motor Capacitor Chart ......................................................................................... 96
4
Fan and Heater
Roof Damage Warning and Disclaimer
WARNING! BE ALERT!
Personnel servicing fans and
heaters should read this manual.
Failure to read this manual and its
safety instructions is a misuse of
the equipment.
The symbol shown is used to call
your attention to instructions con-
cerning your personal safety.
Watch for this symbol; it points
out important safety precautions.
It means "ATTENTION",
"WARNING", "CAUTION", and
"DANGER". Read the message
and be cautious to the possibil-
ity of personal injury or death.
Safety Alert Symbol
GSI DOES NOT WARRANT ANY ROOF DAMAGE
CAUSED BY EXCESSIVE VACUUM OR INTERNAL
PRESSURE FROM FANS OR OTHER AIR MOVING
SYSTEMS. ADEQUATE VENTILATION AND/OR
"MAKEUP AIR" DEVICES SHOULD BE PROVIDED
FOR ALL POWERED AIR HANDLING SYSTEMS.
GSI DOES NOT RECOMMEND THE USE OF DOWN-
WARD FLOW SYSTEMS (SUCTION). SEVERE ROOF
DAMAGE CAN RESULT FROM ANY BLOCKAGE
OF AIR PASSAGES. RUNNING FANS DURING HIGH
HUMIDITY/COLD WEATHER CONDITIONS CAN
CAUSE AIR EXHAUST OR INTAKE PORTS TO
FREEZE.
ROOF WARNING, OPERATION & SAFETY
Proper Use of Product
This product is intended for the use of grain
drying only! Any other use is a misuse of this
product. This product has sharp edges! These
sharp edges may cause serious injury. To avoid
injury handle sharp edges with caution and use
proper protective clothing and equipment at all times.
Guards are removed for illustration only. All guards
must be in place before and during operation.
5
Fan and Heater
The GSI Group, Inc. recom-
mends contacting your local power
company, and having a representa-
tive survey your installation so the
wiring is compatible with their sys-
tem, and adequate power is sup-
plied to your unit.
Safety decals should be read
and understood by all people in
the grain handling area.
If a decal is damaged or is
missing contact:
GSI Group, Inc.
1004 E. Illinois St.
Assumption, IL 62510
217-226-4421
A free replacement will be sent to
you.
SAFETY
FAILURE TO INSTALL
THERMOSTAT INCREASES RISK OF FIRE IN BIN!
WARRANTIES ARE VOID ON HEATERS INSTALLED
WITHOUT THERMOSTATS.
CAUTION! BE VERY
CAREFUL WHEN
CHECKING OUT 220V OR
460V CONTROL CIRCUIT.
SERIOUS INJURY OR
DEATH MAY OCCUR IF
PROPER PRECAUTIONS
ARE NOT TAKEN.
BE SURE POWER IS
DISCONNECTED AND
LOCKED OUT BEFORE
INSTALLATION. FAILURE
TO DO SO MAY CAUSE
SERIOUS INJURY OR
DEATH
Fuel Warning
Important! Do not use propane tanks which have previously been used for ammonia unless
they have been purged according to procedures of the National L. P. Association.
Be sure fuel supply system complies with all local codes for L. P. gas installations.
DO NOT USE FLAME FOR LEAK TESTING.
Power Warning
Be sure power is disconnected and locked out before installation!
Failure to do so may cause serious injury or death.
Important! Heater must be interlocked with fan for safe operation.
Important! Thermostat must be installed for safe operation.
6
Fan and Heater
7
Fan and Heater
2000 VANE AXIAL FANS
8
Fan and Heater
It is very important that a machine to earth ground
rod be installed at the fan. This is true even if
there is a ground at the pole 15 feet away. This
ground needs to be as close to the fan as possible,
but no more than 8 feet away. The ground rod
should be connected to the fan control panel with
at least a #6 solid bare copper ground wire, or in
accordance with local requirements. The machine
to earth ground provides additional safety if there
is a short. It also provides the grounding neces-
sary for long life and operation of the solid state
Machine to Earth Ground
Dig a hole large
enough to hold 1
or 2 gallons of
water. Work the
ground rod into
the earth until it
is completely in
the ground.
It is recommended that previ-
ously installed units be checked
to see that a machine to earth
ground has been installed by an
electrician.
(Ground rods and wires are not supplied by GSI
). It is recommended that the rod not be driven
into dry ground. The following steps ensure proper
ground rod installation:
1. Dig a hole large enough to hold 1 to 2 gal-
lons of water.
2. Fill hole with water.
Proper Installation of the Ground Rod
5. Connect the bare copper
ground wire to the rod with
the proper ground rod clamp.
6. Connect the bare ground wire
to the fan control boxes with
a grounding lug. See Figure
3
7. Ground wire must not have
any breaks or splices. Insu-
lated wire is not recom-
mended for grounding.
Figure 1: Use a #6 or approved size bare copper ground wire.
Install a 5/8" diameter 8' long copper-clad ground rod, 2' away
from the foundation and 1' below the surface of the ground or in
accordance with local requirements.
FAN INSTALLATION
Previously Installed
Units
3. Insert rod through water and jab it into the
ground.
4. Continue jabbing the rod up
and down, the water will work
its way down the hole, making
it possible to work the rod com-
pletely into the ground. This
method of installing the rod
gives a good conductive bond
with the surrounding soil.
Cross-sectional area of phase
conductors supplying the
equipment S (mm²)
S<=16
16<=S<35
S=>35
Minimum cross-sectional area
of the external protective
conductor (mm²)
S
16
S÷2
9
Fan and Heater
TEST STATION
10
Fan and Heater
6
4
2
0
60
80
14
14
14
12
10
15
FAN HORSEPOWER
RPM
PHASE
VOLTS
FULL LOAD AMPS
MINIMUM WIRE SIZE
50' RUN
100' RUN
200' RUN
300' RUN
MINIMUM WIRE SIZE
50' RUN
100' RUN
200' RUN
300' RUN
FUSE SIZE (SLOW BLOW)
BREAKER SIZE
3/4
3450
1
230
5.5
3
230
2.6
460
1.3
575
1.0
Copper Wire
14
14
12
10
14
14
14
14
14
14
14
14
14
14
14
14
Aluminum Wire
14
14
10
8
15
20
14
14
14
12
10
15
14
14
14
14
5
10
14
14
14
14
5
10
1
3450
1
230
5.5
3
230
3.0
460
1.5
575
1.2
Copper Wire
14
14
12
10
14
14
14
14
14
14
14
14
14
14
14
14
Aluminum Wire
14
14
10
8
15
20
14
14
14
14
5
10
14
14
14
14
5
10
1.1/2
3450
1
230
7.5
3
230
4.6
460
2.3
575
1.8
Copper Wire
14
12
8
6
14
14
12
10
14
14
14
12
14
14
14
12
Aluminum Wire
12
10
6
4
15
20
12
12
10
10
10
15
14
12
12
12
5
10
14
14
12
12
5
10
3
3450
1
230
15
3
230
7.4
460
3.7
575
3
Copper Wire
12
10
8
6
12
12
10
8
14
12
12
10
14
12
12
10
Aluminum Wire
12
8
6
4
30
40
12
10
10
8
15
20
12
12
10
10
10
15
12
12
10
10
10
15
FAN HORSEPOWER
RPM
PHASE
VOLTS
FULL LOAD AMPS
MINIMUM WIRE SIZE
50' RUN
100' RUN
200' RUN
300' RUN
MINIMUM WIRE SIZE
50' RUN
100' RUN
200' RUN
300' RUN
FUSE SIZE (SLOW BLOW)
BREAKER SIZE
7
3450
1
230
30
3
230
18
460
9
575
6.9
Copper Wire
10
8
4
4
10
10
8
6
12
12
10
8
12
12
12
10
Aluminum Wire
8
6
3
2
40
60
8
8
6
4
25
30
12
10
10
8
15
15
12
12
10
10
15
15
10
3450
1
230
47
3
230
25
460
13
575
9.6
Copper Wire
8
6
4
2
8
6
4
2
12
10
10
8
12
12
10
8
Aluminum Wire
6
4
2
0
30
40
12
10
8
6
20
20
12
10
10
8
15
20
15
3450
1
230
57
3
230
32
460
16
575
14
Copper Wire
6
4
2
0
6
4
2
0
10
10
10
8
10
10
10
10
Aluminum Wire
4
2
0
00
75
100
4
2
0
00
40
60
8
8
6
4
20
30
8
8
8
6
20
20
3450 RPM Vane Axial Fan
FAN SPECIFICATIONS
11
Fan and Heater
FAN
A (BOLT CIRCLE)
B (INSIDE DIA)
C (CL TO BOTTOM OF LEG)
D (LENGTH)
12" Dia
12.3/4
11.7/8
8
14.1/8
Figure 2: Fan dimensions
18" Dia
19.1/2
18.1/4
13.5/16
22
24" Dia
25.3/4
24.1/4
15.3/8
27.1/2
26" Dia
27.11/16
26.5/16
16.7/8
24.1/4
28" Dia
29.5/8
28.1/8
18.1/8
30
Note: All Dimensions in inches.
FAN SPECIFICATIONS
14" Dia
15.1/8
14.1/8
10
14.1/8
12
Fan and Heater
SYMPTOM
Fan will not run
Fan runs for a short period
of time then shuts off
Fan makes ticking noise
Fan vibrates
POSSIBLE CAUSE
Blown fuse or breaker in disconnect switch
Main power not turned on
Defective wiring or loose connection
Incorrect wire size
Overload kicked out
Defective motor
Defective magnetic contactor
Undersize wiring
Low line voltage at the installation. Power
failure.
Magnetic contactor malfunctioning.
Defective start/stop button
Wrong heater strip
Fan blade hitting fan housing
Motor bearing bad
Fan not mounted securely to pad.
Fan not level
Fan has dirt deposit on blade
Motor shaft is bent
Blade not mounted properly on shaft
Blade out of balance
SOLUTION
Replace fuses or reset breakers
Turn power on at all disconnects
ahead of the unit
Follow wiring diagram and tighten
any loose connections
See wire size charts for proper sire
size and change if needed
Check manual reset, push in to reset
Replace motor
Check the magnetic contactor
Check to see that power supply wires
are the proper size, contact your local
power company.
Call power company after making
sure wire size is correct
Change magnetic contactor
Replace necessary part
Replace with proper heater strip
Stop fan and turn off electricity.
Remove fan screen and check to see
if fan blade is hitting the housing.
Adjust motor position to obtain proper
clearance.
Replace motor bearing
Mount fan securely
Level fan
Clean blade
Replace motor
Mount blade properly on shaft
Replace or have blade rebalanced
Fan Troubleshooting Chart
FAN TROUBLESHOOTING
13
Fan and Heater
1. Check for 220V between points C and F. If no
voltage present, check power at primary disconnect.
2. Check for 220V between points C and D. If no
voltage present, check "J" (thermostat) wires.
(on units with " J " wires)
3. Check for 220V between points C and E. If no
voltage present, replace or reset thermal motor
overload.
4. Check for 220V between points F and G. If no
voltage present, replace 1/4 amp fuse.
5. Check for 220V between points F and H. If no
voltage present, checkout stop switch and replace
if necessary.
Push Start Button, Nothing Happens:
CAUTION! BE VERY
CAREFUL WHEN
CHECKING OUT 220V OR
460V CONTROL CIRCUIT.
SERIOUS INJURY OR
DEATH MAY OCCUR IF
PROPER PRECAUTIONS
ARE NOT TAKEN.
Figure 3: Fan circuit board.
6. Check for 220V between points F and I (while
pressing start button). If no voltage present
checkout and replace start switch if necessary.
7. Check for 220V between points A and B (while
pressing start button). If voltage present and
no start, replace coil on contactor.
Push Start Button, Fan Starts but will
not Continue after Start Switch is Re-
leased
1. Auxiliary switch on contactor is probably bad,
checkout and replace if necessary.
Note: Always check for 220 volts at check points.
110 volts to ground does not necessarily mean
check point is okay. Voltage may bleed through
contactor coil and other similar parts.
IMPORTANT: ALL OF THE BELOW SYMPTOMS MAY BE CAUSED BY LOOSE WIRING OR CONNECTIONS.
ALWAYS CHECK IT FIRST!
TROUBLESHOOTING
Fan Control Circuit
14
Fan And Heater
FAN WIRING AND SCHEMATIC
Wiring
240 Volt 1 Phase (15 HP)
Schematic
15
Fan And Heater
Motors used in GSI fan units are all standard
NEMA frame motors and are specially designed for
use in crop drying applications. Most of the replace-
ment parts for these motors are handled by authorized
service stations of the various motor manufacturers.
1. Always disconnect and lock out power before
working on or around fan motor and electrical
components.
2. Malfunctioning electrical components
should be checked by a qualified electrician.
3. For extra motor life, any electric motor
a. Fans setting idle in the summer offer an
excellent place for mud dobbers to build
their nests. A mud dobber nest on the
back of the fan blade will cause the fan
to be out of balance and vibrate.
b. Also, mice have been known to
nest in the back of a blade.
When the fan is
started the centrifugal force kills the mice,
but throws the blade out of balance.
FAN SERVICE
Lubrication
This is a ball bearing motor.
The bearings have been
given initial lubrication at the
factory. Motors without
regreasing capability are fac-
tory lubricated for normal
bearing life.
Relubrication
Intervals
(Motors with Regreasing
Capability)
New motors having been in stor-
age for over a year should be
Hours of
Service Per Year
5000 Hrs.
Continuous Normal Application
Seasonal Service Motor is idle
for 6 months or more
Continuous high ambients, dirty
or moist locations, high
vibration or where shaft end is
hot (pumps-fans)
42 to 215T
5 years
2 years
1 year
(beginning of
season)
6 months
Suggested Relube Interval
NEMAFRAME SIZE
254 to 326T
3 years
1 years
1 year
(beginning of
season)
6 months
364 to 447T
1 years
9 months
1 year
(beginning of
season)
3 months
Lubricant
Baldor motors are pre-greased normally with
Shell Oil Company's "Dolium R". Several equiva-
lent greases which are compatible with the Baldor
Procedure
fitting, clean tip of fitting and apply grease gun.
Use 1 to 2 full strokes on motors in NEMA 215
frame and smaller. Use 2 to 3 strokes on NEMA
Overgreasing bearings can cause premature bear-
ing failure. If motor is equipped with Alemite
should be run for 30 minutes, once a month.
This will help eliminate any damaging mois-
furnished grease are Chevron Oil's "SRI No. 2"
and Texaco Inc.'s "Premium RB".
relubricated by the procedure noted in the chart to
ensure long operating life.
Insert 2 to 3 inch length of grease string into each
hole on motors in NMEA 215 frame and smaller.
Insert 3 to 5 inch length on larger motors. Motors
having grease drain plugs, remove plug and operate
motor for 20 minutes before replacing drain plug.
Keep grease clean. Lubricate motors at stand-
still. Remove and replace drain plugs at stand-
still. Do not mix petroleum grease and silicone
grease in motor bearings.
ture build-up in the motor and bearings.
254 thru NEMA 365 frame. Use 3 to 4 strokes on
NEMA 404 frames and larger. On motors having
drain plugs, remove grease drain plug and oper-
ate motor for 20 minutes before replacing drain
plug.
On motors equipped with slotted head grease
screw, remove screw and apply grease tube to hole.
4. If excess vibration shows up at some point
when the fan has been running smoothly,
check the blade for these conditions:
16
Fan And Heater
Hub Bolt Torque Requirement for Fan Blades
FAN SERVICE
A. 14" 1HP.............................................50 ft. lbs. (Trantorque)
B. 18"-1.5HP..........................................63 ft. lbs. (Trantorque)
C. 24"-7HP through 28" 15HP..............84 ft. lbs. (Trantorque)
D. 24"-7HP through 28" 15HP...............16 ft. lbs. (Browning)
17
Fan And Heater
2000 CENTRIFUGAL FAN SERVICE GUIDE
18
Fan and Heater
FAN SPECIFICATIONS
FAN
3HP
5HP
7.1/2HP
10HP
15HP
20HP
25HP
30HP
40HP
30-50HP
double
F
46.13/16
51.1/8
51.1/8
54.7/16
54.7/16
56.1/2
56.1/2
58.11/16
58.11/16
56.1/2
G
42.15/16
45.1/8
45.1/8
49.9/16
49.9/16
51.3/4
51.3/4
54.5/8
54.5/8
51.3/4
H
15.11/16
16.1/2
20.1/4
19.1/8
21.11/16
21.3/4
24.1/16
23.3/8
25.13/16
46.1/4
I
31.1/8
29.3/16
32.15/16
34.13/16
34.13/16
37.7/16
39.3/4
42.5/16
44.1/8
89.9/16
J
22.7/16
19.7/16
19.7/16
20.1/2
20.1/2
22.3/8
22.3/8
23.1/4
23.1/4
21.1/16
K
37.1/16
31.3/4
31.3/4
34.5/16
34.5/16
38.7/16
38.7/16
41.5/16
41.5/16
38.7/16
1750 RPM FAN
A
23.9/16
27.3/8
27.3/8
30.1/4
30.1/4
33.1/4
33.1/4
33.1/4
33.1/4
33.1/4
B
13.1/2
14.1/4
18
16.15/16
19.1/2
19.9/16
21.7/8
21.7/8
23.11/16
44
C
41.1/8
31.1/8
34.7/8
34.3/16
39.5/16
39.9/16
41.13/16
43.3/8
45.7/8
92.1/16
D
24.7/8
27.3/8
27.3/8
30
30
33.1/2
33.1/2
36.1/2
36.1/2
33.1/2
E
25.1/4
27.3/4
27.3/4
30.3/16
30.3/16
32.15/16
32.15/16
33.3/8
33.3/8
32.15/16
Note: All Dimensions in inches.
FAN
3HP
5HP
7.1/2HP
10HP
15HP
20HP
30HP
40HP
50HP
F
34.13/16
34.13/16
39
39
39
46.13/16
46.13/16
46.13/16
51.1/8
G
32.3/4
32.3/4
37.3/16
37.3/16
37.3/16
42.15/16
42.15/16
42.15/16
45.1/8
H
10.3/8
12.3/16
12.3/16
13.3/16
15.3/16
14.3/4
16.1/4
18.11/16
17.15/16
I
24.15/16
26.13/16
27.9/16
28.9/16
30.9/16
38.3/16
39.11/16
42.1/8
43.1/8
J
13.15/16
13.15/16
12.11/16
12.11/16
12.11/16
18.7/16
18.7/16
18.7/16
20.1/4
K
22.1/8
22.1/8
20.11/16
20.11/16
20.11/16
29
29
29
32.11/16
3500 RPM FAN
A
16.1/2
16.1/2
19
19
19
23.9/16
23.9/16
23.9/16
27.3/8
B
8.1/8
10
10
11
13
12.9/16
14.1/16
16.1/2
15.3/4
C
26.15/16
28.13/16
29.9/16
30.9/16
32.9/16
40.3/16
41.11/16
44.1/16
45.1/16
D
16.1/2
16.1/2
20.1/2
20.1/2
20.1/2
24.7/8
24.7/8
24.7/8
27.3/8
E
17.3/8
17.3/8
20.11/16
20.11/16
20.11/16
25.1/4
25.1/4
25.1/4
27.3/4
19
Fan and Heater
FAN SPECIFICATIONS
2
2
0
0
80
80
8
8
6
4
25
30
FAN HORSEPOWER
RPM
PHASE
VOLTS
FULL LOAD AMPS
MINIMUM WIRE SIZE
50' RUN
100' RUN
200' RUN
300' RUN
MINIMUM WIRE SIZE
50' RUN
100' RUN
200' RUN
300' RUN
FUSE SIZE (SLOW BLOW)
BREAKER SIZE
3
1750
1
230
15
3
230
12
460
6
575
3.6
Copper Wire
10
8
6
4
12
12
8
6
14
12
10
8
14
12
10
8
Aluminum Wire
8
6
4
2
25
30
10
10
6
4
20
20
12
10
8
6
10
15
12
10
8
6
10
15
5
1750
1
230
25
3
230
14
460
7
575
5.5
Copper Wire
8
6
4
2
10
10
8
6
12
12
12
10
12
12
12
10
Aluminum Wire
6
4
2
0
40
40
10
10
10
8
15
15
10
10
10
8
15
15
7.1/2
1750
1
230
35
3
230
22
460
11
575
7.9
Copper Wire
8
6
4
2
10
10
8
6
12
12
12
10
12
12
12
10
Aluminum Wire
6
4
2
0
60
60
8
8
6
4
40
40
10
10
10
8
20
20
10
10
10
8
20
20
10
1750
1
230
40
3
230
28
460
14
575
10.2
Copper Wire
6
6
4
2
6
6
4
3
10
10
8
6
10
10
8
6
Aluminum Wire
4
4
2
0
80
80
4
4
2
2
60
60
8
8
6
4
30
30
8
8
6
4
30
30
FAN HORSEPOWER
RPM
PHASE
VOLTS
FULL LOAD AMPS
MINIMUM WIRE SIZE
50' RUN
100' RUN
200' RUN
300' RUN
MINIMUM WIRE SIZE
50' RUN
100' RUN
200' RUN
300' RUN
FUSE SIZE (SLOW BLOW)
BREAKER SIZE
15
1750
1
230
61
3
230
42
460
21
575
14
Copper Wire
4
4
2
1
6
6
4
3
10
10
8
6
10
10
8
6
Aluminum Wire
2
2
0
00
80
100
4
4
2
2
60
60
8
8
4
3
30
30
8
8
4
3
30
30
20
1750
230
50
3
460
25
575
19.2
Copper Wire
4
4
2
1
10
10
6
4
10
10
6
4
Aluminum Wire
8
8
4
2
40
40
8
8
4
2
40
40
40
1750
3
230
94
460
47
575
37
Copper Wire
1
1
00
0000
6
6
4
2
6
6
4
2
Aluminum Wire
0
0
000
0000
200
200
4
4
2
0
100
100
4
4
2
0
100
100
30
1750
3
230
74
460
37
575
29
Copper Wire
2
2
0
00
6
6
4
3
6
6
4
3
Aluminum Wire
0
0
00
000
150
150
4
4
2
2
80
80
4
4
2
2
80
80
25
1750
3
230
66
460
33
575
25
Copper Wire
2
2
1
0
8
8
6
4
8
8
6
4
Aluminum Wire
0
0
00
00
100
100
6
6
4
2
60
60
6
6
4
2
60
60
1750 RPM FAN SPECIFICATIONS
50
1750
3
230
112
460
56
575
46
Copper Wire
1
1
00
0000
6
6
4
2
6
6
4
2
Aluminum Wire
0
0
000
0000
200
200
4
4
2
0
100
100
4
4
2
0
100
100
20
Fan and Heater
FAN SPECIFICATIONS
10
10
6
4
25
30
FAN HORSEPOWER
RPM
PHASE
VOLTS
FULL LOAD AMPS
MINIMUM WIRE SIZE
50' RUN
100' RUN
200' RUN
300' RUN
MINIMUM WIRE SIZE
50' RUN
100' RUN
200' RUN
300' RUN
FUSE SIZE (SLOW BLOW)
BREAKER SIZE
3
3450
1
230
14.5
3
230
7.8
460
3.9
575
3
Copper Wire
10
8
6
4
12
12
8
6
14
12
10
8
14
12
10
8
Aluminum Wire
8
6
4
2
25
30
10
10
6
4
20
20
12
10
8
6
10
15
12
10
8
6
10
15
5
3450
1
230
19.5
3
230
12
460
6
575
4.8
Copper Wire
10
8
6
4
12
12
8
6
14
12
10
8
14
12
10
8
Aluminum Wire
8
6
4
2
40
40
12
10
8
6
15
15
12
10
8
6
15
15
7.1/2
3450
1
230
33
3
230
18.8
460
9.4
575
7.2
Copper Wire
8
8
6
3
10
10
8
6
14
12
10
8
14
12
10
8
Aluminum Wire
6
6
4
2
60
60
8
8
6
4
40
40
12
10
8
6
20
20
12
10
8
6
20
20
10
3450
1
230
40
3
230
24
460
12
575
9.6
Copper Wire
6
6
4
2
6
6
4
3
10
10
8
6
10
10
8
6
Aluminum Wire
4
4
2
0
80
80
4
4
2
2
60
60
8
8
6
4
30
30
8
8
6
4
30
30
3500 RPM FAN SPECIFICATIONS
4
4
2
2
80
80
FAN HORSEPOWER
RPM
PHASE
VOLTS
FULL LOAD AMPS
MINIMUM WIRE SIZE
50' RUN
100' RUN
200' RUN
300' RUN
MINIMUM WIRE SIZE
50' RUN
100' RUN
200' RUN
300' RUN
FUSE SIZE (SLOW BLOW)
BREAKER SIZE
15
3450
3
230
42
460
21
575
14
Copper Wire
6
6
4
3
10
10
8
6
10
10
8
6
Aluminum Wire
4
4
2
2
60
60
8
8
4
3
30
30
8
8
4
3
30
30
20
3450
230
46
3
460
23
575
19
Copper Wire
6
6
4
3
10
10
6
4
10
10
6
4
Aluminum Wire
8
8
4
2
40
40
8
8
4
2
40
40
40
3450
3
230
112
460
56
575
46
Copper Wire
1
1
00
0000
6
6
4
2
6
6
4
2
Aluminum Wire
0
0
000
0000
200
200
4
4
2
0
100
100
4
4
2
0
100
100
30
3450
3
230
92
460
46
575
38
Copper Wire
2
2
0
00
6
6
4
3
6
6
4
3
Aluminum Wire
0
0
00
000
150
150
4
4
2
2
80
80
4
4
2
2
80
80
50
3450
3
230
112
460
56
575
46
Copper Wire
1
1
00
0000
6
6
4
2
6
6
4
2
Aluminum Wire
0
0
000
0000
200
200
4
4
2
0
100
100
4
4
2
0
100
100
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86
  • Page 87 87
  • Page 88 88
  • Page 89 89
  • Page 90 90
  • Page 91 91
  • Page 92 92
  • Page 93 93
  • Page 94 94
  • Page 95 95
  • Page 96 96
  • Page 97 97
  • Page 98 98