Prestige iQ Owner's Booklet

Type
Owner's Booklet

Prestige iQ is a blood glucose test system that provides simple and accurate blood glucose (sugar) level testing anytime, anywhere. It is designed to help you keep glucose levels in control and lower the chance of developing serious diabetes-related health problems. Prestige iQ features include:

  • Easy to code - Meter Code and Test Strip Calibration Code must match to get correct test results.
  • Standard Strip test - Uses a hard gray plastic strip (Standard Strip) for Quality Control tests when using the Meter for the first time, when using a new vial of Test Strips, if results do not ‘agree’ with how you feel, if you suspect that results are incorrect, to practice using the System and after cleaning the Meter or replacing the Test Strip Platform.

Prestige iQ is a blood glucose test system that provides simple and accurate blood glucose (sugar) level testing anytime, anywhere. It is designed to help you keep glucose levels in control and lower the chance of developing serious diabetes-related health problems. Prestige iQ features include:

  • Easy to code - Meter Code and Test Strip Calibration Code must match to get correct test results.
  • Standard Strip test - Uses a hard gray plastic strip (Standard Strip) for Quality Control tests when using the Meter for the first time, when using a new vial of Test Strips, if results do not ‘agree’ with how you feel, if you suspect that results are incorrect, to practice using the System and after cleaning the Meter or replacing the Test Strip Platform.
Owners Booklet
Prestige Smart System
®
is a registered trademark of
Home Diagnostics, Inc.
Ft. Lauderdale, FL 33309 U.S.A.
Printed in U.S.A. • © HDI 2007
IQQ603 Rev. 7
Blood Glucose
SYSTEM
Blood Glucose
SYSTEM
IQ
IQ
Owners Booklet
0197
Authorized Representative:
AR-MED Ltd. Runnymede Malthouse,
Egham TW20 9BD, United Kingdom
24 Hour Toll-Free Assistance
Available in English & Spanish
7 days per week.
Call 1-800-803-6025
www.homediagnostics.com
Our Commitment to you
Our goal is to provide you with quality healthcare products
and dedicated customer service. If you have any questions
about the use of our
PPrreessttiiggee SSmmaarrtt SSyysstteemm
®
®
products, visit
our web site at www.homediagnostics.com or please call:
1-800-803-6025
For Medical Assistance,
call your Doctor or Diabetes Healthcare Professional.
Notes: ________________________________
_____________________________________
_____________________________________
_____________________________________
_____________________________________
_____________________________________
_____________________________________
_____________________________________
_____________________________________
_____________________________________
_____________________________________
_____________________________________
_____________________________________
_____________________________________
_____________________________________
_____________________________________
_____________________________________
_____________________________________
_____________________________________
_____________________________________
Congratulations on the purchase of your Prestige
Smart System
®
Blood Glucose Test System. You
now have a very simple and accurate way to test your
blood glucose (sugar) levels, anytime, anywhere.
Glucose testing is an important part of controlling
your diabetes. Studies show that keeping glucose
levels in control may lower the chance of developing
serious diabetes-related health problems such as
kidney problems and blindness. Regular testing lets
you know if your sugar is ‘too high’, ‘too low’, or
‘just right’, depending on what you and your
Healthcare Professional decide is ‘just right’ for you.
Do not use the
Prestige Smart System
®
IQ Meter in
any way not recommended in this Booklet.
1
For
assistance
call
Use
By
date
Lot
number
For in vitro
diagnostic
testing only
Authorized
Representative
Sterile
Single
Use
Only
Low
Control
Range
SYMBOLS:
Code
number
Number
of Tests
Attention! Read
Instructions
for Use.
Storage
temperature
range
Manufactured
by
High
Control
Range
Serial
number
IMPORTANT:
1. Read ALL instructions before use.
2. Use only Prestige Smart System
®
Test
Strips and Prestige Smart System
®
blue
Glucose Control Solution when testing
with Prestige Smart System
®
IQ Meters.
3. Code your IQ Meter: Meter Code and Test
Strip Calibration Code MUST match to get
correct test results.
4. Check any results that “feel” wrong:
Repeat the test if your results seem much
higher or lower than you think they should be.
5. Work with your Diabetes Healthcare
Professional: Discuss your results with your
Diabetes Healthcare Professional.
6. Use only
W
W
h
h
o
o
l
l
e
e
B
B
l
l
o
o
o
o
d
d
when testing with
the Prestige Smart System
®
: If you choose
to display results as plasma, the Meter uses
the whole blood value to calculate and then
display the plasma value.
7. The Prestige Smart System is not
recommended for diagnosing diabetes or
testing blood glucose in newborns.
2
TABLE OF CONTENTS
Section 1 The Prestige Smart System
®
. . . . 4-10
IQ Meter . . . . . . . . . . . . . . . . . . . . . . 4-5
Test Strip Vial . . . . . . . . . . . . . . . . . . . 6
Test Strip . . . . . . . . . . . . . . . . . . . . . . . 6
Meter Options . . . . . . . . . . . . . . . . 7-10
Section 2 CODE THE METER. . . . . . . . . . . . 11
Section 3 CHECK THE SYSTEM . . . . . . 12-18
Standard Strip Test . . . . . . . . . . . . 13-14
Glucose Control Test . . . . . . . . . . 15-18
Section 4 TEST WHOLE BLOOD . . . . . . 19-21
Section 5 IMPORTANCE OF TESTING. . . . 22
Section 6 METER MEMORY . . . . . . . . . . 23-25
Recalling Blood Test Results . . . . 23-24
Recalling Morning Average Value. . . 25
Section 7
CLEANING & MAINTENANCE
. . 26-27
Section 8 CHANGE METER BATTERY 28-29
Section 9 DISPLAY MESSAGES . . . . . . . 30-34
Section 10 TROUBLESHOOTING. . . . . . . 35-36
Section 11 METER SPECIFICATIONS . . . . . 37
References . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . 39-40
3
Back of Meter
Î
Ï
4
Front of Meter
·
¸
¹
Section 1 The Prestige Smart System
®
Prestige Smart System
®
IQ Meter
Display Screen:
Shows numbers, words and
symbols needed to operate
the Meter.
·
Power Button:
Turns Meter on and off.
Meter turns off after 3
minutes of non-use.
¸
Test Strip Platform:
Holds Test Strip or Standard
Strip in place during a test.
¹
Test Window:
Area under Test Strip
Platform that contains Meter
optics.
Î
Battery Compartment:
Holds one replaceable AAA
(1.5 volt) alkaline battery.
Ï
Meter Label:
Provides Meter name, serial
number and toll-free number
for assistance.
5
Right Side of Meter
¸
¹
Î
Left Side of Meter
Up
Down
·
Up/Down Button:
Used to view Meter options,
change Code Number, view
stored results or Morning
Average.
·
Select (S) Button:
Use to select options, access
Memory or Morning
Average.
¸
Standard Strip Holder:
Stores Standard Strip.
¹
Standard Strip:
Use for Standard Strip test.
Î
Communication Port:
Use to attach Prestige
Smart System
®
serial cable
to Meter.
WARNING!
U
U
s
s
e
e
o
o
n
n
l
l
y
y
Prestige Smart System
®
s
s
e
e
r
r
i
i
a
a
l
l
c
c
a
a
b
b
l
l
e
e
i
i
n
n
p
p
o
o
r
r
t
t
.
.
P
P
u
u
t
t
t
t
i
i
n
n
g
g
a
a
n
n
y
y
t
t
h
h
i
i
n
n
g
g
e
e
l
l
s
s
e
e
i
i
n
n
t
t
o
o
p
p
o
o
r
r
t
t
m
m
a
a
y
y
d
d
a
a
m
m
a
a
g
g
e
e
M
M
e
e
t
t
e
e
r
r
.
.
P
P
l
l
e
e
a
a
s
s
e
e
c
c
a
a
l
l
l
l
f
f
o
o
r
r
m
m
o
o
r
r
e
e
i
i
n
n
f
f
o
o
r
r
m
m
a
a
t
t
i
i
o
o
n
n
a
a
b
b
o
o
u
u
t
t
u
u
s
s
e
e
o
o
f
f
t
t
h
h
e
e
C
C
o
o
m
m
m
m
u
u
n
n
i
i
c
c
a
a
t
t
i
i
o
o
n
n
P
P
o
o
r
r
t
t
.
.
·
¸
Front of Strip
Back of Strip
¹
Î
Prestige Smart System
®
Test Strip Vial Label
Calibration Code:
Meter Code must be matched
to this number for vial of
Test Strips being used.
·
Expiration Date:
Date after which Test Strips
cannot be used.
¸
Control Range:
Range of numbers in which
Glucose Control test results
must fall to be sure that
System is working correctly.
À
for Low,
Á
for High
Prestige Smart System
®
Test Strip
¹
Test Spot:
Apply blood or Glucose
Control solution here.
Î
Color Spot:
Changes color after blood or
Control solution is applied to
the Test Spot.
6
Meter Options
The Meter has the following options that can be
customized to your needs. Options are listed below
in the order that they appear in the Display.
Results as Whole Blood (blood): Whole blood is
blood that comes directly from finger. Use only
whole blood when testing.
Results as Plasma (plasma): Most laboratories use
plasma, a component of blood, for testing. Plasma
results are about 12% higher than whole blood
results.
1
When selecting this option, Meter uses the
whole blood value to calculate and display the
plasma result.
N
N
E
E
V
V
E
E
R
R
u
u
s
s
e
e
p
p
l
l
a
a
s
s
m
m
a
a
f
f
o
o
r
r
t
t
e
e
s
s
t
t
i
i
n
n
g
g
w
w
i
i
t
t
h
h
Prestige Smart System
®
.
.
mg/dL: Glucose unit of measure expressed as
milligrams per deciliter, used in U.S.
mmol/L: Glucose unit of measure expressed as
millimoles per liter, used in some countries outside
U.S. When selecting this option, choose either
Com
(comma: 6,1 mmol/L) or Per (period: 6.1 mmol/L).
7
Avg=14d: The average of all morning blood glucose
results for the last 14 days.
Avg=30d: The average of all morning blood glucose
results for the last 30 days.
12 hr: Time based on 12 hour clock (am/pm).
24 hr: Time based on 24 hour clock.
m-d-y: Date displayed as month-day-year
(03-11-2009).
d.m.y: Date displayed as day.month.year
(11.03.2009).
I
I
f
f
y
y
o
o
u
u
h
h
a
a
v
v
e
e
a
a
n
n
y
y
q
q
u
u
e
e
s
s
t
t
i
i
o
o
n
n
s
s
r
r
e
e
g
g
a
a
r
r
d
d
i
i
n
n
g
g
t
t
h
h
e
e
s
s
e
e
O
O
p
p
t
t
i
i
o
o
n
n
s
s
,
,
p
p
l
l
e
e
a
a
s
s
e
e
c
c
a
a
l
l
l
l
f
f
o
o
r
r
a
a
s
s
s
s
i
i
s
s
t
t
a
a
n
n
c
c
e
e
.
.
8
Set Meter Options
1. Go to options. Press and hold
P
P
o
o
w
w
e
e
r
r
Button
until Display flashes, then
release
P
P
o
o
w
w
e
e
r
r
Button. Meter
beeps and displays “Set-up”
and then “Type”.
2. Set the options. Press top or bottom of the
U
U
p
p
/
/
D
D
o
o
w
w
n
n
Button to switch
between the selections
available. Press
S
S
e
e
l
l
e
e
c
c
t
t
(
(
S
S
)
)
Button to set the option.
Meter Options
Results as
Blood or Plasma
mg/dL or mmol/L
unit of glucose measure
Period or Comma
delimiter(mmol/L only)
14 or 30 day
Morning Average
12 or 24 hour clock
9
®
®
or
or
or
or
or
Up/Down Select (S)
03-11-2009
03-11-2009
11-03-2009
11-03-2009
or
Day
03-11-2009
03-11-2009
11-03-2009
11-03-2009
or
Month
11-03-2009
11-03-2009
Year
3. Set Time. Press
U
U
p
p
/
/
D
D
o
o
w
w
n
n
Button to
change the flashing number.
Press
S
S
e
e
l
l
e
e
c
c
t
t
(S) to set.
4. Set Date Format. Press
U
U
p
p
/
/
D
D
o
o
w
w
n
n
Button to
switch between m-d-y and
d.m.y. Press
S
S
e
e
l
l
e
e
c
c
t
t
(S) to set.
5. Set Date. Press
U
U
p
p
/
/
D
D
o
o
w
w
n
n
Button to
change the flashing number.
Press
S
S
e
e
l
l
e
e
c
c
t
t
(S) to set. Turn
Meter off. Meter is now ready
to use for testing.
N
N
O
O
T
T
E
E
:
:
C
C
h
h
e
e
c
c
k
k
T
T
i
i
m
m
e
e
a
a
n
n
d
d
D
D
a
a
t
t
e
e
a
a
f
f
t
t
e
e
r
r
e
e
a
a
c
c
h
h
b
b
a
a
t
t
t
t
e
e
r
r
y
y
c
c
h
h
a
a
n
n
g
g
e
e
.
.
R
R
e
e
s
s
e
e
t
t
i
i
f
f
n
n
e
e
c
c
e
e
s
s
s
s
a
a
r
r
y
y
.
.
A
A
l
l
l
l
o
o
t
t
h
h
e
e
r
r
M
M
e
e
t
t
e
e
r
r
O
O
p
p
t
t
i
i
o
o
n
n
s
s
r
r
e
e
m
m
a
a
i
i
n
n
i
i
n
n
M
M
e
e
m
m
o
o
r
r
y
y
a
a
s
s
s
s
e
e
l
l
e
e
c
c
t
t
e
e
d
d
.
.
Minutes Hours
or
10
Section 2 Code The Meter
1. Gather supplies needed.
• Meter
• Test Strip Vial
2. Turn Meter on. Press and release
P
P
o
o
w
w
e
e
r
r
Button.
3. Match Codes.
Compare Code shown in
Display to Code printed on
Strip vial being used. Codes
must match. If Codes DO
NOT match, go to Step 4.
(
(
C
C
a
a
l
l
i
i
b
b
r
r
a
a
t
t
i
i
o
o
n
n
C
C
o
o
d
d
e
e
N
N
u
u
m
m
b
b
e
e
r
r
s
s
r
r
a
a
n
n
g
g
e
e
f
f
r
r
o
o
m
m
0
0
-
-
2
2
3
3
)
)
4. Code Meter. Press top of
U
U
p
p
/
/
D
D
o
o
w
w
n
n
Button to increase number;
press bottom of Button to
decrease number. Meter
stores Code automatically.
11
Section 3 Check The System
There are two types of Quality Control tests to
assure that the System is working properly and
testing technique is good.
Standard Strip test uses a hard gray plastic strip
(Standard Strip). The Standard Strip does not
have a lot number or an expiration date, and can
be used with any Meter Code.
Glucose Control test uses a
d
d
a
a
r
r
k
k
b
b
l
l
u
u
e
e
liquid
(Glucose Control) that contains a known amount
of glucose. Glucose Control is available in both
Low
À and High Á levels.
These tests should be performed:
When using the Meter for the first time
When using a new vial of Test Strips
When results do not ‘agree’ with how you feel
When you suspect that results are incorrect
To practice using the System
After cleaning the Meter or replacing the Test
Strip Platform
(
(
A
A
L
L
W
W
A
A
Y
Y
S
S
p
p
e
e
r
r
f
f
o
o
r
r
m
m
t
t
h
h
e
e
S
S
t
t
a
a
n
n
d
d
a
a
r
r
d
d
S
S
t
t
r
r
i
i
p
p
t
t
e
e
s
s
t
t
)
)
.
W
W
A
A
R
R
N
N
I
I
N
N
G
G
!
!
B
B
o
o
t
t
h
h
t
t
h
h
e
e
S
S
t
t
a
a
n
n
d
d
a
a
r
r
d
d
S
S
t
t
r
r
i
i
p
p
a
a
n
n
d
d
G
G
l
l
u
u
c
c
o
o
s
s
e
e
C
C
o
o
n
n
t
t
r
r
o
o
l
l
t
t
e
e
s
s
t
t
s
s
m
m
u
u
s
s
t
t
g
g
i
i
v
v
e
e
c
c
o
o
r
r
r
r
e
e
c
c
t
t
r
r
e
e
s
s
u
u
l
l
t
t
s
s
o
o
r
r
b
b
l
l
o
o
o
o
d
d
g
g
l
l
u
u
c
c
o
o
s
s
e
e
r
r
e
e
s
s
u
u
l
l
t
t
s
s
m
m
a
a
y
y
n
n
o
o
t
t
b
b
e
e
c
c
o
o
r
r
r
r
e
e
c
c
t
t
.
.
R
R
e
e
f
f
e
e
r
r
t
t
o
o
S
S
e
e
c
c
.
.
1
1
0
0
,
,
T
T
r
r
o
o
u
u
b
b
l
l
e
e
s
s
h
h
o
o
o
o
t
t
i
i
n
n
g
g
G
G
u
u
i
i
d
d
e
e
.
.
12
Standard Strip (Right Side)
13
78-104
The Standard Strip Test
1. Gather supplies.
• Meter
• Standard Strip
2. Remove Standard Strip from Meter.
Clean Strip with water only
and dry thoroughly before use.
Do not bend Standard Strip.
3. Turn Meter on. Press and release
P
P
o
o
w
w
e
e
r
r
Button.
4. Perform test. Slide Standard Strip all the
way into Test Strip Platform
with Range Label facing up.
N
N
O
O
T
T
E
E
:
:
D
D
o
o
n
n
o
o
t
t
m
m
o
o
v
v
e
e
S
S
t
t
a
a
n
n
d
d
a
a
r
r
d
d
S
S
t
t
r
r
i
i
p
p
o
o
r
r
M
M
e
e
t
t
e
e
r
r
d
d
u
u
r
r
i
i
n
n
g
g
t
t
e
e
s
s
t
t
i
i
n
n
g
g
o
o
r
r
a
a
n
n
e
e
r
r
r
r
o
o
r
r
m
m
e
e
s
s
s
s
a
a
g
g
e
e
m
m
a
a
y
y
a
a
p
p
p
p
e
e
a
a
r
r
.
.
Meter detects Strip and
begins test.
When test is complete, the
result is displayed.
5. Check result. Compare Meter result to
range of numbers printed on
Range Label. If test result is
within range, Meter is
working properly.
N
N
O
O
T
T
E
E
:
:
I
I
f
f
r
r
e
e
s
s
u
u
l
l
t
t
i
i
s
s
N
N
O
O
T
T
w
w
i
i
t
t
h
h
i
i
n
n
r
r
a
a
n
n
g
g
e
e
,
,
c
c
l
l
e
e
a
a
n
n
T
T
e
e
s
s
t
t
W
W
i
i
n
n
d
d
o
o
w
w
a
a
n
n
d
d
S
S
t
t
a
a
n
n
d
d
a
a
r
r
d
d
S
S
t
t
r
r
i
i
p
p
(
(
s
s
e
e
e
e
S
S
e
e
c
c
.
.
7
7
,
,
C
C
l
l
e
e
a
a
n
n
i
i
n
n
g
g
M
M
a
a
i
i
n
n
t
t
e
e
n
n
a
a
n
n
c
c
e
e
)
)
,
,
d
d
r
r
y
y
t
t
h
h
o
o
r
r
o
o
u
u
g
g
h
h
l
l
y
y
a
a
n
n
d
d
r
r
e
e
p
p
e
e
a
a
t
t
t
t
e
e
s
s
t
t
.
.
I
I
f
f
r
r
e
e
s
s
u
u
l
l
t
t
i
i
s
s
s
s
t
t
i
i
l
l
l
l
o
o
u
u
t
t
s
s
i
i
d
d
e
e
o
o
f
f
r
r
a
a
n
n
g
g
e
e
,
,
c
c
a
a
l
l
l
l
f
f
o
o
r
r
a
a
s
s
s
s
i
i
s
s
t
t
a
a
n
n
c
c
e
e
.
.
6. Replace Standard Strip.
Remove Strip from Test
Platform and place it back
into the Holder with Range
Label facing down.
14
78-104
Label Face Down
(Right Side of Meter)
The Glucose Control Test
The Control test is performed exactly like a blood test.
Control is used instead of blood. Be sure to read
Glucose Control Instructions for Use before using for
the first time. Control results are not stored in Memory.
1. Gather supplies needed:
• Meter
• Test Strips
• Glucose Control Solution
(
(
d
d
a
a
r
r
k
k
b
b
l
l
u
u
e
e
)
)
2. Check expiration dates.
Check expiration date on
Strip vial and Control bottle.
If your bottle of Control is
being used for first time,
write date opened on bottle.
3. Turn Meter on. Press and release
P
P
o
o
w
w
e
e
r
r
Button.
N
N
O
O
T
T
E
E
:
:
U
U
s
s
e
e
e
e
x
x
p
p
i
i
r
r
a
a
t
t
i
i
o
o
n
n
d
d
a
a
t
t
e
e
p
p
r
r
i
i
n
n
t
t
e
e
d
d
o
o
n
n
u
u
n
n
o
o
p
p
e
e
n
n
e
e
d
d
C
C
o
o
n
n
t
t
r
r
o
o
l
l
b
b
o
o
t
t
t
t
l
l
e
e
l
l
a
a
b
b
e
e
l
l
.
.
O
O
n
n
c
c
e
e
C
C
o
o
n
n
t
t
r
r
o
o
l
l
b
b
o
o
t
t
t
t
l
l
e
e
i
i
s
s
o
o
p
p
e
e
n
n
e
e
d
d
,
,
C
C
o
o
n
n
t
t
r
r
o
o
l
l
s
s
o
o
l
l
u
u
t
t
i
i
o
o
n
n
e
e
x
x
p
p
i
i
r
r
e
e
s
s
2
2
m
m
o
o
n
n
t
t
h
h
s
s
f
f
r
r
o
o
m
m
t
t
h
h
e
e
d
d
a
a
t
t
e
e
o
o
p
p
e
e
n
n
e
e
d
d
.
.
15
LB0010
9 JUNE 2009
LB0010
9 JUNE 2009
11 March 09
11 March 09
4. Match Codes. Meter Code must match to
Code printed on Strip vial
being used. If Codes do not
match, see
Sec. 2, Code the
Meter
.
5. Perform test. Remove one Strip from vial,
hold Strip at end away from
Test Spot. Immediately close
vial tightly.
N
N
O
O
T
T
E
E
:
:
D
D
o
o
n
n
o
o
t
t
p
p
u
u
t
t
S
S
t
t
r
r
i
i
p
p
d
d
o
o
w
w
n
n
o
o
n
n
a
a
d
d
a
a
m
m
p
p
o
o
r
r
d
d
i
i
r
r
t
t
y
y
s
s
u
u
r
r
f
f
a
a
c
c
e
e
.
.
D
D
o
o
n
n
o
o
t
t
c
c
u
u
t
t
o
o
r
r
a
a
l
l
t
t
e
e
r
r
S
S
t
t
r
r
i
i
p
p
s
s
i
i
n
n
a
a
n
n
y
y
w
w
a
a
y
y
.
.
Gently swirl bottle several
times.
D
D
O
O
N
N
O
O
T
T
S
S
H
H
A
A
K
K
E
E
.
.
Remove cap from bottle.
Hold bottle upside down and
squeeze one full drop onto a
tissue.
While holding Control bottle
upside down, place bottle over
Test Spot of Test Strip. Squeeze
one drop onto Test Spot.
16
LB0010
9 JUNE 2009
LB0010
9 JUNE 2009
LB00
10
9 JUNE 2009
11 March 09
11 March 09
11 March 09
17
N
N
O
O
T
T
E
E
:
:
D
D
o
o
n
n
o
o
t
t
a
a
p
p
p
p
l
l
y
y
m
m
o
o
r
r
e
e
t
t
h
h
a
a
n
n
o
o
n
n
e
e
d
d
r
r
o
o
p
p
o
o
f
f
C
C
o
o
n
n
t
t
r
r
o
o
l
l
t
t
o
o
T
T
e
e
s
s
t
t
S
S
p
p
o
o
t
t
.
.
D
D
o
o
n
n
o
o
t
t
a
a
l
l
l
l
o
o
w
w
C
C
o
o
n
n
t
t
r
r
o
o
l
l
t
t
o
o
b
b
e
e
d
d
r
r
a
a
w
w
n
n
b
b
a
a
c
c
k
k
i
i
n
n
t
t
o
o
b
b
o
o
t
t
t
t
l
l
e
e
.
.
D
D
o
o
n
n
o
o
t
t
u
u
s
s
e
e
i
i
f
f
C
C
o
o
n
n
t
t
r
r
o
o
l
l
d
d
r
r
o
o
p
p
c
c
o
o
n
n
t
t
a
a
i
i
n
n
s
s
a
a
i
i
r
r
b
b
u
u
b
b
b
b
l
l
e
e
s
s
.
.
Turn Strip over. Check
Color Spot for full color
development.
N
N
O
O
T
T
E
E
:
:
I
I
f
f
C
C
o
o
l
l
o
o
r
r
S
S
p
p
o
o
t
t
l
l
o
o
o
o
k
k
s
s
l
l
i
i
k
k
e
e
t
t
h
h
i
i
s
s
o
o
r
r
(large white spots/white areas)
t
t
h
h
e
e
r
r
e
e
i
i
s
s
n
n
o
o
t
t
e
e
n
n
o
o
u
u
g
g
h
h
C
C
o
o
n
n
t
t
r
r
o
o
l
l
o
o
n
n
t
t
h
h
e
e
T
T
e
e
s
s
t
t
S
S
t
t
r
r
i
i
p
p
.
.
D
D
O
O
N
N
O
O
T
T
a
a
d
d
d
d
m
m
o
o
r
r
e
e
C
C
o
o
n
n
t
t
r
r
o
o
l
l
t
t
o
o
T
T
e
e
s
s
t
t
S
S
p
p
o
o
t
t
!
!
D
D
i
i
s
s
c
c
a
a
r
r
d
d
S
S
t
t
r
r
i
i
p
p
a
a
n
n
d
d
r
r
e
e
p
p
e
e
a
a
t
t
t
t
e
e
s
s
t
t
u
u
s
s
i
i
n
n
g
g
n
n
e
e
w
w
S
S
t
t
r
r
i
i
p
p
.
.
I
I
f
f
C
C
o
o
l
l
o
o
r
r
S
S
p
p
o
o
t
t
a
a
p
p
p
p
e
e
a
a
r
r
s
s
w
w
e
e
t
t
,
,
t
t
h
h
e
e
r
r
e
e
i
i
s
s
t
t
o
o
o
o
m
m
u
u
c
c
h
h
C
C
o
o
n
n
t
t
r
r
o
o
l
l
o
o
n
n
t
t
h
h
e
e
T
T
e
e
s
s
t
t
S
S
t
t
r
r
i
i
p
p
.
.
D
D
i
i
s
s
c
c
a
a
r
r
d
d
S
S
t
t
r
r
i
i
p
p
a
a
n
n
d
d
r
r
e
e
p
p
e
e
a
a
t
t
t
t
e
e
s
s
t
t
u
u
s
s
i
i
n
n
g
g
n
n
e
e
w
w
S
S
t
t
r
r
i
i
p
p
.
.
Turn Strip over so Test Spot
faces up. Point arrow printed
on Strip towards Meter and
slide Strip into Test Strip
Platform within 60 seconds.
W
W
A
A
R
R
N
N
I
I
N
N
G
G
!
!
S
S
l
l
i
i
d
d
e
e
S
S
t
t
r
r
i
i
p
p
a
a
l
l
l
l
t
t
h
h
e
e
w
w
a
a
y
y
i
i
n
n
t
t
o
o
T
T
e
e
s
s
t
t
S
S
t
t
r
r
i
i
p
p
P
P
l
l
a
a
t
t
f
f
o
o
r
r
m
m
t
t
o
o
a
a
v
v
o
o
i
i
d
d
e
e
r
r
r
r
o
o
r
r
m
m
e
e
s
s
s
s
a
a
g
g
e
e
o
o
r
r
a
a
f
f
a
a
l
l
s
s
e
e
r
r
e
e
s
s
u
u
l
l
t
t
.
.
Meter is counting seconds.
Test is complete. Result is
displayed.
6. Check Control results.
Compare result to Control
Range printed on vial of
Strips being used. Compare
to
À Low Range for Low
Control, or
Á High Range
for High Control.
7. Discard Strip. Slide Strip out of Meter.
8. Wipe tip of Bottle with tissue.
Recap bottle. Store bottle in
a cool, dry place at 59º-86ºF
or 15º-30ºC
N
N
O
O
T
T
E
E
:
:
I
I
f
f
C
C
o
o
n
n
t
t
r
r
o
o
l
l
r
r
e
e
s
s
u
u
l
l
t
t
i
i
s
s
o
o
u
u
t
t
o
o
f
f
r
r
a
a
n
n
g
g
e
e
,
,
r
r
e
e
p
p
e
e
a
a
t
t
t
t
e
e
s
s
t
t
w
w
i
i
t
t
h
h
n
n
e
e
w
w
S
S
t
t
r
r
i
i
p
p
.
.
C
C
h
h
e
e
c
c
k
k
C
C
o
o
l
l
o
o
r
r
S
S
p
p
o
o
t
t
a
a
n
n
d
d
i
i
n
n
s
s
e
e
r
r
t
t
S
S
t
t
r
r
i
i
p
p
i
i
n
n
t
t
o
o
T
T
e
e
s
s
t
t
S
S
t
t
r
r
i
i
p
p
P
P
l
l
a
a
t
t
f
f
o
o
r
r
m
m
w
w
i
i
t
t
h
h
i
i
n
n
6
6
0
0
s
s
e
e
c
c
o
o
n
n
d
d
s
s
.
.
I
I
f
f
r
r
e
e
s
s
u
u
l
l
t
t
i
i
s
s
s
s
t
t
i
i
l
l
l
l
n
n
o
o
t
t
w
w
i
i
t
t
h
h
i
i
n
n
r
r
a
a
n
n
g
g
e
e
,
,
c
c
a
a
l
l
l
l
f
f
o
o
r
r
a
a
s
s
s
s
i
i
s
s
t
t
a
a
n
n
c
c
e
e
.
.
18
LB 0010
9 JUNE 2009
11 March 09
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44

Prestige iQ Owner's Booklet

Type
Owner's Booklet

Prestige iQ is a blood glucose test system that provides simple and accurate blood glucose (sugar) level testing anytime, anywhere. It is designed to help you keep glucose levels in control and lower the chance of developing serious diabetes-related health problems. Prestige iQ features include:

  • Easy to code - Meter Code and Test Strip Calibration Code must match to get correct test results.
  • Standard Strip test - Uses a hard gray plastic strip (Standard Strip) for Quality Control tests when using the Meter for the first time, when using a new vial of Test Strips, if results do not ‘agree’ with how you feel, if you suspect that results are incorrect, to practice using the System and after cleaning the Meter or replacing the Test Strip Platform.

Ask a question and I''ll find the answer in the document