DCVH480EK

GE DCVH480EK User manual

  • Hello! I am an AI chatbot trained to assist you with the GE DCVH480EK User manual. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
For answers to your Monogram,
®
GE Profile
or
GE
®
appliance questions, visit our website at
ge.com or call GE Answer Center
®
service,
800.626.2000.
Specification Revised 7/09
360423
Listed by
Underwriters
Laboratories
Dimensions and Installation Information (in inches)
Exhaust Options: 4-way via rear, right, left and bottom.
Circuit Requirements: An individual, properly grounded
branch circuit, protected by a 30-amp circuit breaker or
a time-delay fuse, is required.
Note: Dryer wall outlet must be located within 36
of service cord entry and accessible when dryer is
mounted in position.
Installation Information: For complete information, see
installation instructions packed with your dryer.
23 1/2” 20 11/16”
25 11/16”
33 3/8”
POWER
STA RT
PAUSE
H
M
L
E L
A B
10
20
30
40
50
60
70
80
M D
L D
D
E D
W
ARM
U
P
SPEED DRY
DELICATES
COTTONS
WRINKLEFREE
ACTIVE WEAR
MIXED LOAD
E T
D S
D A
TIME DRY
S
ENSOR
D
RY
AIR FLUFF
TIMED DRY
DEWRINKLE
TIME SENSORTEMP
S
POWER
STA RT
PAUSE
Electric Dryer Rating
240V
3000W, 12.5A, 60Hz
DCVH480/485EK
GE
®
4.0 Cu. Ft. Capacity Frontload Electric Dryer
For answers to your Monogram,
®
GE Profile
or
GE
®
appliance questions, visit our website at
ge.com or call GE Answer Center
®
service,
800.626.2000.
360423
Specification Revised 7/09
Special Installation Requirements:
Stacked Installation:
•Bracketsforstackingdryeroverwasherareincludedwiththewasher.
Alcove or Closet Installation:
•Ifyourdryerisapprovedforinstallationinanalcoveorcloset,itwillbe
stated on a label on the dryer back.
•ThedryerMUSTbeexhaustedtotheoutside.
•Minimumclearancesbetweendryercabinetandadjacentwallsorother
surfaces are: 0" either side, 3" front and rear
•Minimumverticalspacefromfloortooverheadcabinets,ceilings,etc.is52".
•Closetdoorsmustbelouveredorotherwiseventilatedandmustcontaina
minimumof60sq.in.ofopenareaequallydistributed.Ifthisclosetcontains
both a washer and a dryer, doors must contain a minimum of 120 sq. in. of
open area equally distributed.
•Nootherfuel-burningapplianceshallbeinstalledinthesameclosetwith
a gas dryer.
Bathroom or Bedroom Installation:
•ThedryerMUSTbeexhaustedtotheoutdoors.
•Theinstallationmustconformwiththelocalcodes,orintheabsenceof
localcodes,withtheNationalElectricCodeandNationalFuelGasCode,
ANSIZ223forgasdryers.
Minimum Clearance other than Alcove or Closet Installations:
•Minimumclearancestocombustiblesurfaces0"bothsides,3"rear.
For more information on venting kits and accessories,
please call 1-800-GE-CARES.
Stacked Dimensions (in inches)
P
S
P
S
P
S
T D
S D
P
S
67 5/8”
23 1/2”
23 3/4”
23 3/4”
4”
33 1/2”
26 1/2”
26 5/8”
DCVH480/485EK
GE
®
4.0 Cu. Ft. Capacity Frontload Electric Dryer
Listed by
Underwriters
Laboratories
Specification Revised 7/09
360423
Dryer Exhausting Information Metal Duct Only
For complete information, see installation instructions packed with your dryer.
Ducting Materials: For best performance, this dryer should be vented with 4” diameter
allrigidmetalexhaustduct.Ifrigidmetalductcannotbeused,thenUL-listedflexible
metal(semi-rigid)ductingcanbeused(KitWX08X10077).Inspecialinstallations,itmay
benecessarytoconnectthedryertothehouseventusingaflexiblemetal(foil-type)duct.
AUL-listedflexiblemetal(foil-type)ductmaybeusedONLYininstallationswhererigid
metalorflexiblemetal(semi-rigid)ductingcannotbeusedANDwherea4”diametercan
be maintained throughout the entire length of the transition duct. Please see installation
instructionpackedwithyourdryerforcompleteinstructionswhenusingflexiblemetal
(foil type) ducting.
Exhaust Length Calculation:
1. Determinethenumberof90°turnsneededforyourinstallation.Ifyouexhausttothe
side or bottom of dryer, add one turn.
2. Themaximumlengthof4’rigid(aluminumorgalvanized)ductwhichcanbetoleratedis
shown in the table.
Aturnof45°orlessmaybeignored.Two45°turnswithintheductlengthshouldbe
treated as a 90° elbow.
A turn over 45° should be treated as a 9elbow.
Dryers mustbeexhaustedtotheoutside.
Caution: Forpersonalsafetydonotterminateexhaustintoachimney,underanyenclosed
house floor (crawl space), or into an attic, since the accumulated lint could create a fire
hazardormoisturecouldcausedamage.Neverterminatetheexhaustintoacommonduct
orplenumwithakitchenexhaust,sincethecombinationoflintandgreasecouldcreatea
fire hazard.
Exhaustductsshouldbeterminatedinadamperedwallcaptopreventbackdrafts,bird
nesting,etc.Thewallcapmustalsobelocatedatleast12"abovethegroundoranyother
obstruction with the opening pointed down.
For more information on venting kits and accessories, please call 1-800-GE-CARES.
DCVH480/485EK
GE
®
4.0 Cu. Ft. Capacity Frontload Electric Dryer
Listed by
Underwriters
Laboratories
Best performance
Domestic
dryer models
Maximum length of 4"
dia. rigid metal duct
Number
of
90°
turns
Exhaust hood type
A
4"
opening
B
2-1/2"
opening
4.0 cu. ft.
capacity models
all electric dryers
0
1
2
3
90 ft.
60 ft.
45 ft.
35 ft.
60 ft.
45 ft.
35 ft.
25 ft.
A
4
B
2-1/ 2
A
Specification Revised 7/09
360423
ADJUST
TIME DRY
HOLD 3 SECS TO
LOCK & UNLOCK
CONTROL PANEL
POWER
STA RT
PAUSE
E
STIMA T ED
T
IME
R
EMAIN ING
HIGH
MEDIUM
LOW
EXTRA LOW
A
NTI-
B
ACTERIAL
10
20
30
40
50
60
70
80
M
ORE DRY
DRY
LESS DRY
DAMP
E
XTRA
D
RY
WARM UP
SPEED DRY
DELICAT ES
COTTONS
WRINKLE FREE
ACTIVE WEAR
MIXED LOAD
EXTEND TUMBLE
D
ELAY
S
TA RT
DAMP ALERT
ADJUST
TIME DRY
TIME DRY
SENSOR DRY
NO HEAT
AIR FLUFF
TIMED DRY
DEWRINKLE
TIME SENSORTEMP
HOLD 3 SECS TO
LOCK & UNLOCK
CONTROL PANEL
SIGNAL
POWER
STA R T
PAUSE
DRYING COOLDOWNDAMP
CLEAN LINT FILTER
DELAY
Features and Benefits
• 4.0Cu.Ft.LargeStainlessSteelBasket-Handlesaking-sizecomforteror24full-size
bath towels with ease
• 5HeatSelections-Offerenhanceddryingperformanceandfabriccare
• SensorDry
- Continually monitors moisture content to help prevent clothing wear
and tear
• StainlessSteelDrumInterior-Smoothstainlessinteriorhelpspreventrustand
protect clothes
• MultipleDryCycles-Deliveroptimaldryingresults
• DelayStart-Letsyoudothelaundryonyourterms
• AntibacterialOption-CertifiedbytheNSF
®
to reduce up to 99.9% of certain types
of bacteria
• ExtendedTumblePlus-Tumbleclotheswithoutheattohelppreventcreasing
and wrinkling
• SpeedDry-Deliversready-to-goresultsinminutes
• ModelDCVH480EKWW–Whiteonwhite
• ModelDCVH485EKMS–Metallicsilver
DCVH480/485EK
GE
®
4.0 Cu. Ft. Capacity Frontload Electric Dryer
/