Dell XC6320 Hyper-converged Appliance Owner's manual

Category
Servers
Type
Owner's manual
Dell XC6320 Web-Scaled Hyperconverged
Appliance
Owner's Manual
Notes, cautions, and warnings
NOTE: A NOTE indicates important information that helps you make better use of your computer.
CAUTION: A CAUTION indicates either potential damage to hardware or loss of data and tells you
how to avoid the problem.
WARNING: A WARNING indicates a potential for property damage, personal injury, or death.
© 2016 Dell Inc. All rights reserved. This product is protected by U.S. and international copyright and intellectual
property laws. Dell and the Dell logo are trademarks of Dell Inc. in the United States and/or other jurisdictions. All other
marks and names mentioned herein may be trademarks of their respective companies.
2016 - 05
Rev. A02
Contents
1 About the Dell XC6320.........................................................................................7
About your system.................................................................................................................................7
Accessing system features during startup............................................................................................ 7
Front panel features and indicators......................................................................................................8
Hard drive indicator patterns.............................................................................................................. 10
Back panel features and indicators.....................................................................................................10
System-board assembly configurations.............................................................................................12
LAN indicator codes............................................................................................................................ 12
Power and system board indicator codes..........................................................................................14
Power Supply Unit indicator codes.....................................................................................................15
1600 W AC/1600 W HVDC PSU....................................................................................................15
iDRAC heart beat LED......................................................................................................................... 16
Documentation references.................................................................................................................16
2 Performing initial system configuration ........................................................17
Setting up your system........................................................................................................................17
Setting up and configuring the iDRAC IP address..............................................................................17
Logging in to iDRAC............................................................................................................................18
Methods of installing the operating system....................................................................................... 18
Managing your system remotely........................................................................................................ 18
Downloading drivers and firmware.................................................................................................... 18
3 Pre-operating system management applications........................................20
Navigation keys................................................................................................................................... 20
System Setup.......................................................................................................................................20
Entering System Setup...................................................................................................................21
System Setup details......................................................................................................................21
System BIOS Settings details.........................................................................................................21
System Information details........................................................................................................... 22
Memory Settings details................................................................................................................22
Processor Settings details............................................................................................................. 23
SATA Settings details..................................................................................................................... 24
Boot Settings details......................................................................................................................27
Network Settings screen details....................................................................................................27
Integrated Devices details............................................................................................................. 27
Serial Communication details.......................................................................................................29
System Profile Settings details...................................................................................................... 29
System Security Settings details................................................................................................... 30
3
Miscellaneous Settings details...................................................................................................... 32
System setup options at boot.............................................................................................................32
About Boot Manager...........................................................................................................................33
Viewing Boot Manager..................................................................................................................33
Boot Manager main menu............................................................................................................ 33
Changing the boot order....................................................................................................................33
Choosing the system boot mode.......................................................................................................33
Assigning a system and setup password ...........................................................................................34
Deleting or changing system and setup password............................................................................35
4 Installing and removing system components...............................................36
Safety instructions...............................................................................................................................36
Recommended tools.......................................................................................................................... 36
Opening and closing the system ....................................................................................................... 37
Removing the system cover..........................................................................................................37
Installing the system cover........................................................................................................... 38
Inside the system................................................................................................................................ 38
Cooling fans........................................................................................................................................ 38
Removing a cooling fan................................................................................................................38
Installing a cooling fan..................................................................................................................40
Hard drives...........................................................................................................................................41
Removing a 2.5-inch hard drive blank..........................................................................................41
Installing a 2.5-inch hard drive blank........................................................................................... 42
Removing a hard drive.................................................................................................................. 42
Installing a hard drive.................................................................................................................... 43
Removing a hard drive from a hard drive carrier.........................................................................44
Installing a hard drive into a hard drive carrier.............................................................................45
SATADOM............................................................................................................................................45
Important information about SATADOM..................................................................................... 45
Removing the SATADOM..............................................................................................................46
Installing the SATADOM................................................................................................................47
Cable routing for SATADOM and LSI 2008..................................................................................48
Power supply units..............................................................................................................................48
Removing a power supply unit.....................................................................................................49
Installing a power supply unit.......................................................................................................50
System board assembly...................................................................................................................... 50
Removing the system board tray .................................................................................................50
Installing the system board tray ................................................................................................... 51
Removing the system board assembly ........................................................................................ 51
Installing the system board assembly ..........................................................................................52
Air baffle ..............................................................................................................................................53
Removing the cooling shroud ..................................................................................................... 53
4
Installing the cooling shroud ....................................................................................................... 54
Heat sinks............................................................................................................................................ 54
Removing the heat sink ................................................................................................................55
Installing the heat sink ..................................................................................................................56
Processors .......................................................................................................................................... 56
Removing a processor ................................................................................................................. 56
Installing a processor ....................................................................................................................57
Expansion card assembly and expansion card ................................................................................. 58
Removing the expansion card...................................................................................................... 58
Installing the expansion card........................................................................................................60
Riser card ............................................................................................................................................ 61
Removing the riser card................................................................................................................ 61
Installing the riser card..................................................................................................................62
LSI 2008 Mezzanine Card...................................................................................................................62
Removing the LSI 2008 SAS mezzanine card.............................................................................. 63
Installing the LSI 2008 SAS mezzanine card ...............................................................................64
Mezzanine card bridge board ............................................................................................................64
Removing the mezzanine card bridge board ............................................................................. 64
Installing the mezzanine card bridge board ................................................................................65
System memory.................................................................................................................................. 65
Memory slot features ................................................................................................................... 66
Supported memory module configuration .................................................................................66
Removing the memory modules .................................................................................................67
Installing the memory modules....................................................................................................68
System battery ....................................................................................................................................69
Replacing the system battery ...................................................................................................... 69
System board ...................................................................................................................................... 71
Removing a system board ............................................................................................................ 71
Installing a system board ..............................................................................................................72
Entering the system Service Tag using System Setup .................................................................73
5 Troubleshooting your system.......................................................................... 75
Safety first—for you and your system.................................................................................................75
Minimum configuration to POST .......................................................................................................75
Safety first – for you and your system ...............................................................................................75
Installation-related issues................................................................................................................... 75
Troubleshooting system startup failure .............................................................................................76
Troubleshooting external connections..............................................................................................76
Troubleshooting the video subsystem ..............................................................................................76
Troubleshooting a USB device........................................................................................................... 76
Troubleshooting a serial I/O device....................................................................................................77
Troubleshooting a NIC .......................................................................................................................77
5
Troubleshooting a wet system............................................................................................................77
Troubleshooting a damaged system .................................................................................................78
Troubleshooting the system battery.................................................................................................. 78
Troubleshooting PSUs.........................................................................................................................79
Troubleshooting system cooling issues.............................................................................................79
Troubleshooting a fan........................................................................................................................ 80
Troubleshooting system memory......................................................................................................80
Troubleshooting a hard drive .............................................................................................................81
Troubleshooting a storage controller ................................................................................................81
Troubleshooting expansion cards......................................................................................................82
Troubleshooting processors...............................................................................................................82
IRQ assignment conflicts....................................................................................................................83
6 Jumpers and connectors ................................................................................. 85
Dell XC6320 system board connectors............................................................................................. 85
LSI 2008 SAS mezzanine card connectors........................................................................................ 87
Jumper settings...................................................................................................................................87
System configuration jumper settings on the Dell XC6320 system board................................ 88
7 Getting help.........................................................................................................89
Contacting Dell................................................................................................................................... 89
Dell SupportAssist............................................................................................................................... 89
Locating your system Service Tag......................................................................................................89
Quick Resource Locator..................................................................................................................... 91
6
1
About the Dell XC6320
About your system
The Dell XC6320 system is a web-scale converged appliance based on the Dell PowerEdge C6320 and
supports 512 GB memory (with 32 GB RDIMMs), six hard drives per node, and up to four nodes per
chassis.
Accessing system features during startup
The following keystrokes provide access to system features during startup.
NOTE: The hot keys of SAS or SATA card or PXE support are available in BIOS boot mode only.
There is no hot key to boot in the the UEFI mode.
F2 Enters the System Setup program.
F11 Enters the BIOS Boot Manager.
F12 Starts Preboot eXecution Environment (PXE)/iSCSI boot.
Ctrl +C Enters the LSI 2008 SAS Mezzanine Card Configuration Utility. For more
information, see the SAS adapter documentation.
Ctrl+R Enters the PERC 9 Card Configuration Utility. For more information, see the
documentation for your SAS RAID card.
Ctrl+Y Enters the MegaPCLI SAS RAID Management Tool.
Ctrl+S Enters the utility to configure onboard LAN settings for PXE boot. For more
information, see the documentation for your integrated LAN.
Ctrl+I Enters onboard SATA Controller’s Configuration Utility.
Ctrl+D Enters the Intel iSCSI setup menu.
7
Front panel features and indicators
Figure 1. Front panel features and indicators
NOTE: For more information about the direction details of the 2.5-inch hard drive expander
configuration support, see the HDD Zoning configuration tool at Dell.com/support.
Table 1. Front-panel features and indicators
Item Indicator, button or
connector
Icon Description
1 System identification indicator
or button for system board 2
The identification button can
be used to locate a particular
system and system board
within a chassis. When the
button is pushed, the blue
status indicator of the system
on the front and rear blinks
until the button is pushed
again.
2 Power-on indicator or system
state indicator or power button
for system board 2
The power-on indicator turns
to green when the system
power is on.
3 System identification indicator
or button for system board 1
The identification button can
be used to locate a particular
system and system board
within a chassis. When the
button is pushed, the blue
status indicator of the system
on the front and rear blinks
until the button is pushed
again.
4 Power-on indicator or system
state indicator or power button
for system board 1
The power-on indicator turns
to amber when the system
critical event occurs.
5 Hard drives Up to 24, hot-swappable, 2.5--
inch hard drives.
8
Item Indicator, button or
connector
Icon Description
6 Drive cover This is not a usable drive slot.
7 Power-on indicator or system
state indicator or power button
for system board 3
NOTE: When turning on
the system, the video
monitor can take from
several seconds to over
two minutes to display an
image, depending on the
amount of DIMM installed
in the system.
NOTE: On ACPI-
compliant operating
systems (OSs), turning off
the system by using the
power button causes the
system to perform a
graceful shutdown before
the system is turned off.
NOTE: To force an
ungraceful shutdown,
press and hold the power
button for five seconds.
8 System identification indicator
or button for system board 3
The identification button can
be used to locate a particular
system and system board
within a chassis. When the
button is pushed, the blue
status indicator of the system
on the front and rear blinks
until the button is pushed
again.
9 Power-on indicator or system
state indicator or power button
for system board 4
The power button controls the
DC power supply unit (PSU)
output to the system.
10 System identification indicator
or button for system board 4
The identification button can
be used to locate a particular
system and system board
within a chassis. When the
button is pushed, the blue
status indicator of the system
on the front and rear blinks
until the button is pushed
again.
9
Hard drive indicator patterns
Figure 2. Hard drive front view
1. hard drive status indicator (green and amber) 2. hard drive activity indicator (green)
Table 2. Hard drive indicator patterns
Controller Hard drive type Function Activity LED Status LED
Green Green
Onboard
Controller
SATA2 Drive on-line Off/Blinking when
active
On
Fail Off On
Back panel features and indicators
Figure 3. Back panel features and indicators
10
Table 3. Back panel features and indicators
Item Indicator, button, or
connector
Icon Description
1 PSU 2 1600 W AC PSUs.
2 PSU 1 1600 W AC PSUs.
3 USB port Enables you to connect USB
devices to the system. The
ports are USB 3.0-compliant.
4 Ethernet connector 10G NIC 1 connector.
5 Ethernet connector 10G NIC 2 connector.
6 Management port Dedicated management port.
7 USB to serial port Connects the system to a host.
8 VGA port Connects a VGA display to the
system.
9 Power button/power and
system LED
The power-on indicator glows
green when the system power
is on.
The power-on indicator turns
amber when the system critical
event occurs.
The power button controls the
DC PSU output to the system.
NOTE: When turning on
the system, the video
monitor can take from
several seconds to over
two minutes to display an
image, on the basis of the
disk space available in the
system.
NOTE: On ACPI-
compliant operating
systems, turning off the
system by using the
power button causes the
system to perform a
graceful shutdown before
the system is turned off.
11
Item Indicator, button, or
connector
Icon Description
NOTE: To force an
ungraceful shutdown,
press and hold the power
button for five seconds.
10 System identification indicator The management software of
both the systems and the
identification buttons on the
front can cause the indicator
to flash blue to identify a
particular system and system
board. Indicators turn amber
when the system requires
attention because of an issue.
System-board assembly configurations
Figure 4. Enumeration four system boards for 1U node
LAN indicator codes
Figure 5. LAN indicators
1. activity indicator 2. link and network speed indicator
12
Table 4. LAN indicator codes
Component Indicator Condition
Link and network speed indicator Solid amber Linking at 1 Gbps speed
Solid green Linking at 10 Gbps speed
Activity indicator Blinking green Activity is present:
• Pre OS POST
• OS without driver
• OS with driver
Blinking at speed relative to
packet density.
Off No link/activity present
• D0 (uninitialized)
• D3 (cold)
• S4 (hibernation)
Figure 6. LAN indicators (management port)
1. speed indicator 2. link and activity indicator
Table 5. LAN indicators (management port)
Component Indicator Condition
Speed indicator Solid green Linking at 1 Gbps speed
Solid amber Linking at 10/100 Mbps speed
Link and activity indicator Off No access or Idle
Blinking green LAN access or Link up
13
Power and system board indicator codes
The LEDs on the system front panel and back panel display status codes during system startup. For
location of the LEDs on the front panel, see the Front panel features and indicators section. For location
of the LEDs on the back panel, see the Back panel features and indicators section.
Table 6. Status indicator codes
Component Indicator Condition
Power-on indicator (A
bicolor LED on power
button)
Green Solid Power On (S0)
Amber Off
Green Off iDRAC critical condition event in Power Off mode
(S4/S5)
Amber Blinking
Green Off iDRAC critical condition event in Power On mode
(S0)
Amber Blinking
System identification
indicator
Steady blue IPMI using Chassis Identify Command On or ID
Button Press ID On
Blinking blue Only IPMI using Chassis Identify Command Blink
On
Off IPMI using Chassis Identify Command Off or ID
Button Press ID Off
14
Power Supply Unit indicator codes
Each AC power supply unit (PSU) has an illuminated translucent handle that indicates whether power is
present or whether a power fault has occurred.
1600 W AC/1600 W HVDC PSU
Figure 7. PSU status indicator
1. PSU 2. AC power indicator
Table 7. 1600 W AC/1600 W HVDC PSU indicators
Component Indicator Condition
AC power indicator Solid amber
Standby mode with Fan Lock for
15 seconds.
Standby mode with OTP range
Active mode with +12 V DC Fault
Active mode with Fan Lock for 15
seconds.
Solid green DC_OK (power good)
Blinking green Standby mode normal
Off Unit without AC power
15
iDRAC heart beat LED
The system board provides iDRAC heart beat LED (CR17) for iDRAC debugs. The iDRAC heart beat LED is
green. When the system AC power is connected, the LED glows. When iDRAC firmware is ready, the
iDRAC heart beat LED blinks.
Figure 8. iDRAC heart beat LED on the Dell XC6320 system board
1. iDRAC heart beat LED
Documentation references
For information about the Dell documents, see the Support Matrix specific for your product.
For information about the Nutanix documents that applies to a specific release of Nutanix solution
software, see the Support Matrix specific for your product.
16
2
Performing initial system configuration
After you receive your system, you must set up your system, install the operating system if it is not pre-
installed, and set up and configure the system iDRAC IP address.
Setting up your system
1. Unpack the system.
2. Install the system into the rack. For more information about installing the system into the rack, see
your system Rack Installation Placemat.
3. Connect the peripheral devices to the system.
4. Connect the system to its electrical outlet.
5. Turn on the system by pressing the power button or by using iDRAC.
6. Turn on the attached peripheral devices.
Setting up and configuring the iDRAC IP address
You can set up the Integrated Dell Remote Access Controller (iDRAC) IP address by using one of the
following interfaces:
• Dell iDRAC Settings utility
• Dell Lifecycle Controller
• Dell OpenManage Deployment Toolkit
You can use the default iDRAC IP address 192.168.0.120 to configure the initial network settings,
including setting up DHCP or a static IP for iDRAC.
You can configure iDRAC IP address by using the following interfaces:
NOTE: Ensure that you change the default user name and password after setting up the iDRAC IP
address.
• iDRAC Web interface: For more information, see the Integrated Dell Remote Access Controller User's
Guide.
• Remote Access Controller ADMin (RACADM): For more information, see the RACADM Command Line
Interface Reference Guide and the Integrated Dell Remote Access Controller User's Guide.
• Remote Services that include Web Services Management (WS-Man): For more information, see the
Dell Lifecycle Controller Remote Services Quick Start Guide.
For more information about setting up and configuring iDRAC, see the Integrated Dell Remote Access
Controller User's Guide available at Dell.com/esmmanuals.
17
Logging in to iDRAC
You can log in to iDRAC as an iDRAC local user, a Microsoft Active Directory user, or a Lightweight
Directory Access Protocol (LDAP) user. You can also log in by using Single Sign-On or a Smart Card. The
default user name is root and password is calvin. For more information about logging in to iDRAC and
iDRAC licenses, see the Integrated Dell Remote Access Controller User's Guide available at Dell.com/
idracmanuals.
You can also access iDRAC by using RACADM. For more information, see the RACADM Command Line
Interface Reference Guide and the Integrated Dell Remote Access Controller User's Guide available at
Dell.com/idracmanuals.
Methods of installing the operating system
If the system is shipped without an operating system, install the supported OS on the system by using one
of the following methods:
• Dell Systems Management Tools and Documentation media — see the operating system
documentation available at Dell.com/operatingsystemmanuals.
• Dell Lifecycle Controller — see the Dell Lifecycle Controller documentation available at Dell.com/
idracmanuals.
• Dell OpenManage Deployment Toolkit — see the Dell OpenManage documentation available at
Dell.com/openmanagemanuals → OpenManage software.
For information about supported operating systems, see the operating systems support matrix available at
Dell.com/ossupport.
Managing your system remotely
To perform out-of-band systems management by using iDRAC, configure iDRAC for remote accessibility,
set up the management station and managed system, and configure the supported web browsers. For
more information, see the Integrated Dell Remote Access Controller User’s Guide at Dell.com/
idracmanuals.
You can also remotely monitor and manage the server by using the Dell OpenManage Server
Administrator (OMSA) software and OpenManage Essentials (OME) systems management console. For
more information, see Dell.com/openmanagemanuals → OpenManage Server Administrator or
Dell.com/openmanagemanuals → OpenManage Essentials.
Downloading drivers and firmware
Dell recommends you to download and install the latest BIOS, drivers, and systems management
firmware on your system.
Ensure that you clear the web browser cache.
1. Go to Dell.com/support/drivers.
2. In the Identify your product section, enter the Service Tag of your system in Enter a Service Tag or
Express Service Code.
18
NOTE: If you do not have the Service Tag, you can do one of the following:
• Select Auto-detect your product to allow the system to automatically detect your Service
Tag
• Select Browse for a product to select your product from the Select a product page.
3. Click Drivers and downloads.
The drivers that are applicable to your selection are displayed.
4. Repeat steps 1 through 3 to download the HDD zoning configuration utility.
5. Search on the basis of Category, and then click System Utilities.
HDD zoning configuration utility is displayed.
19
3
Pre-operating system management
applications
You can manage basic settings and features of a system without booting to the operating system by
using the system firmware.
Navigation keys
The navigation keys can help you access the pre-operating system management applications.
Page Up Moves to the previous screen.
Page Down Moves to the next screen.
Up arrow Moves to the previous field.
Down arrow Moves to the next field.
Enter Enables you to type a value in the selected field (if applicable) or follow the link in
the field.
Spacebar Expands or collapses a drop-down list, if applicable.
Tab Moves to the next focus area.
NOTE: This feature is applicable for the standard graphical browser only.
Esc Moves to the previous page until you view the main screen. Pressing Esc in the
main screen exits System BIOS/iDRAC Settings/Device Settings/Service Tag
Settings and proceeds with system boot.
F1 Displays the System Setup help information.
F2 Enables you to enter System Setup.
F10 Enables you to enter Lifecycle Controller.
F11 Enables you to enter Boot Manager.
F12 Enables you to enter PXE boot.
System Setup
By using the System Setup screen, you can configure the BIOS settings, iDRAC settings, and device
settings of your system.
These settings have already been preconfigured per solution requirements. Contact Dell before you
change these settings.
20
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86
  • Page 87 87
  • Page 88 88
  • Page 89 89
  • Page 90 90
  • Page 91 91

Dell XC6320 Hyper-converged Appliance Owner's manual

Category
Servers
Type
Owner's manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI